• Title/Summary/Keyword: Gain of output ratio(G.O.R)

Search Result 2, Processing Time 0.018 seconds

A Study on the MED-TVC Operating Performance Characteristics of using the Thermo-Compressor (열압축기를 채용한 다중효용 담수설비의 운전특성에 관한 연구(1보))

  • Choi, Du-Youl;Jin, Chang-Fu;Song, Young-Ho;Choi, Soon-Ho;Chung, Han-Shik;Kim, Pil-Hwan
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1185-1191
    • /
    • 2008
  • The core design technology for the multi-effect desalination plant using the thermo compressor (MED-TVC) was investigated by the performance test of multi effect desalination plant in this paper. The final G.O.R (gain of output ratio) of MED-TVC type desalination plant is strongly affected by the performance of thermo-vapor compressor. The present experiments for the desalinating capacity and G.O.R were obtained for the range of the motive steam pressure, 266.0, 250.0, 230.0 and 200.0 kPa. And as a practical problem, to investigate the influence of the sea water temperature to the G.O.R, the inlet steam temperature of the suction water vapor was changed in the range of $311.2{\sim}324.2$ K in the present experiment. Through the experiments, the maximum value of G.O.R was 8.5 at the condition of the motive steam pressure, 136.0 kPa and the minimum value of G.O.R was 8.1 at the condition of the motive steam pressure, 266.0 kPa. And it was confirmed that the range of desalination capacity was $355.2{\sim}264.0$ ton/day in the normal operation condition.

Numerical study on the flow characteristics of horizontal tube bundle (Tube-bundle형 열교환기의 액막 유동에 관한 시뮬레이션)

  • Kim, Pil-Hwan;Choi, Du-Youl;Woo, Ju-Sik;Jeong, Hyo-Min;Chung, Han-Shik;Kim, Kyeong-Seok
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1256-1261
    • /
    • 2009
  • Seawater amounts to 70% of the earth and represents a quite unlimited resource for the production of fresh water by desalination processes and for the extraction of dissolved salts present in it. Recently, the falling film evaporation has increased in interest as an efficient method for seawater desalination system. In the desalination system, the flow characteristics of the falling film is very important issue to make highly efficient system. So, this study is taken to investigate numerically the falling film thickness on the inlet Renold Number ranges are 400 to 700. Numerical simulations are performed using FLUENT6.3.26, a commercial CFD code.

  • PDF