• 제목/요약/키워드: Gage factor

검색결과 49건 처리시간 0.026초

스트레인게이지법을 이용한 동적응력확대계수 평가 (Evaluation on dynamic stress intensity factor using strain gage method)

  • 이현철;김덕희;김재훈;문순일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2000년도 추계학술대회논문집A
    • /
    • pp.304-309
    • /
    • 2000
  • Strain gage method is used to evaluate the mode I dynamic stress intensity factor of marging steel(18Ni) and titanium alloy(Ti-6A1-4V). To decide the best strain gage position on specimen, static fracture toughness test was performed. Then instrumented charpy impact test and dynamic tensile test was performed by using strain gage method for evlauating dynamic stress intensity factor. Strain gage signals on the crack tip region are used to calculate the stress intensity factors. It is found that strain gage method is more useful than method by using load which is obtained from impact tup to assess dynamic characteristics such as dynamic stress intensity factor.

  • PDF

스트레인 측정에 의한 응력확대계수의 결정 (Determination ofStress Intenstiy Factor by Strain Measurement)

  • 이억섭;홍성경;윤경수
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.369-374
    • /
    • 1993
  • Measurements of strain near a crack tip with electrical resistance strain gages do not usually provide a reliable value of stress intensity factor (K sub I) because of local yielding and limited regions for strain-gage placement. This paper attempted to define a valid region and to indicate procedures for locating and orienting the strain-gage to determine stress intensity factor accurately from one stain-gage readings.

  • PDF

군간-군내-부품내 변동을 고려한 Gage R&R 분석에 관한 연구 (A Study of Gage R&R Analysis Considering the Variations of Between-Within Group and Within Part)

  • 이승훈;이창우
    • 산업공학
    • /
    • 제18권4호
    • /
    • pp.444-453
    • /
    • 2005
  • The purpose of the Gage R&R study is to determine whether a measurement system is adequate for monitoring a process. If the measurement system variation is small relative to the process variation, then the measurement system is deemed "adequate". The sources of variation associated with the measurement system are compared using an analysis of variance (ANOVA) model, in general. A typical ANOVA model used in a standard Gage R&R study is the two-factor random effect model. Then, the ANOVA partitions the total variation into three categories: repeatability, reproducibility, part variation. However, if the process variation possesses the between group variation, within group variation, and within part variation, these variations can cause the measurement system evaluation to provide misleading results. That is, in the standard Gage R&R study these variations affect the estimate of repeatability, reproducibility, or both. This paper presents a four-factor nested factorial ANOVA model which explicitly considers these variations for the Gage R&R study. The variance component estimators are derived by setting the EMS equations equal to the corresponding mean square from the ANOVA table and solving. And the proposed model is compared with the standard Gage R&R model.

스트레인측정에 의한 응력확대계수 결정 (Determination of Stress Intensity Factors by Strain Measurement)

  • 이억섭;나경찬
    • 한국정밀공학회지
    • /
    • 제12권8호
    • /
    • pp.147-155
    • /
    • 1995
  • Recent experimental studies have been shown that strain gages can be employed to determine either static or dynamic stress intensity factors $K_{I}$ wiht relatively simple experiments. However, it does not usually provide a reliable value of stress intensity factor because of local yielding and limited regions for strain gage placement at the vicinity of the crack tip. This paper attempted to define a valid region and to indicate procedures for locating and orienting the strain gage to determine static toughness $K_{Is}$ accurately form one strain gage readings with respect to varying loadings. The strain gage methods was used for compact tension specimens made of Polycarbonate and PMMA(polymethyl methacrylate). Series expansions of the static and dynamic strain fields are applied. Strain gage orientation and location are then studied to optimize the strain response. Especially, in the dynamic experiment, the specimen employed is an oversized Charpy V-notch specimen which has been modified to provide significant constraint with a large elevation of the flow stress. The impact behavior of the specimen is monitored by placing strain gage near the crack tip. The dynamic toughness $K_{Id}$ is determined from the strain time traces of this gage.e.

  • PDF

군간-군내-부품내 변동을 고려한 Gage R&R 분석에 관한 연구 (A Study of Gage R&R Analysis Considering the Variations of Between-Within Group and Within Part)

  • 이승훈;이창우
    • 한국경영과학회:학술대회논문집
    • /
    • 한국경영과학회/대한산업공학회 2005년도 춘계공동학술대회 발표논문
    • /
    • pp.975-982
    • /
    • 2005
  • The purpose of the Gage R&R study is to determine whether a measurement system is adequate for monitoring a process. If the measurement system variation is small relative to the process variation, then the measurement system is deemed 'adequate'. The sources of variation associated with the measurement system are compared using an analysis of variance (ANOVA) model, in general. A typical ANOVA model used in a standard Gage R&R study is the two-factor random effect model. Then, the ANOVA partitions the total variation into three categories: repeatability, reproducibility, part variation. However, if the process variation possesses the between group variation, within group variation, and within-part variation, these variations can cause the measurement system evaluation to provide misleading results. That is, in the standard Gage R&R study these variations affect the estimate of repeatability, reproducibility, or both. This paper presents a four-factor nested factorial ANOVA model which explicitly considers these variations for the Gage R&R study. The variance component estimates are derived by setting the EMS equations equal to the corresponding mean square from the ANOVA table and solving. And the proposed model is compared with the standard Gage R&R model.

  • PDF

극저온 환경에서 스트레인 게이지의 게이지상수 및 변형률 측정에 관한 연구 (The Characteristic Test for Gage Factors of Strain Gages in Cryogenic Environment)

  • 김갑순;주진원
    • 대한기계학회논문집
    • /
    • 제17권9호
    • /
    • pp.2205-2213
    • /
    • 1993
  • The characteristic test for gage factors of temperature self-compensated strain gages at cryogenic temperature is presented. By joining the international round robin test on electrical strain gages at cryogenic temperatures, the gage factors of three kinds of widely-used strain gages are obtained at the room temperature, the temperatures of liquid nitrogen and liquid helium. The calibration system which produce precise bending strain is by mechanical loading at cryogenic temperature. This paper also presents the creep characteristic of strain gages at maximum strain level.

스트레인게이지법을 이용한 응력확대계수 측정 (Measurement of Stress Intensity Factor Using Strain Gage Methods)

  • 김재훈;문순일;이현철;김덕희
    • 한국추진공학회지
    • /
    • 제4권1호
    • /
    • pp.53-64
    • /
    • 2000
  • 모드 I 응력확대계수를 결정하기 위한 스트레인게이지법이 연구되었다. CT 시험편과 3점 굽힘 시험편이 사용되었다. 시험편의 예리한 노치부는 와이어 방전 가공에 의하여 제작되었다. 균열 선단 영역으로부터 얻은 스트레인게이지 신호는 응력확대계수를 계산하는데 사용되었다. 시험 결과는 ASTM E399에 의하여 얻어진 결과 및 유한요소해석 결과와 비교하였다. 시험 결과들과 유한요소해석 결과는 잘 일치하였다. 이 방법을 적용할 때 스트레인게이지 부착 위치는 신중히 고려되어야 한다.

  • PDF

2024-T3 A1 합금의 이방성이 피로균열진전속도와 정류거동에 미치는 영향 (Effect of Anisotropy on Fatigue Crack Propagation Rate and Arrest Behavior with 2024-T3 Alumunum Alloy)

  • 오세욱;김태형;오정종
    • 한국해양공학회지
    • /
    • 제7권1호
    • /
    • pp.124-132
    • /
    • 1993
  • In order to examine the effect of anisotropy and stress ratio on fatigue crack propagation rate and opening-closing behavior and also arrest behavior by single tension peak overload, the fatigue tests of constant amplitude atress and single tension peak overload adding to cycle of constant amplitude were carried out in stress ratio of -0.4, -0.2, and 0.4 with materials of T-L and L-T directions in 2024-T3 aluminum alloy plate. Crack opening-closing begavior were measured by the compliance method using COD gage and strain gage. In case of the crack opening-closing behavior was measured by strain gage, the effect of stress ratio is unchangeable. But in the case of COD gage, that is remarkably decreased. Fictitious effective stress intensity factor(U sub(f)) and effective stress intensity factor ratio(U) in L-T direction was higher than those in T-L direction and also threshold arrest overload ratio incrased as stress ratio decreased and that of T-L direction was higher than that in L-T direction.

  • PDF

반도체 게이지를 이용한 360 방향의 트랜스듀서 개발 (Development of a Transducer for Cursor Control by use of Semiconductor Strain Gage)

  • 김민석;송후근;이정태;김성배;이명훈
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2003년도 춘계학술대회 논문집
    • /
    • pp.1430-1433
    • /
    • 2003
  • Transducers, which are incorporated in control devices for fixed wing aircraft, land vehicles. and weapon systems were designed and manufactured by use of semiconductor strain gages. These transducers consist of three parts; flange mounts, sensing rods, and semiconductor strain gages. In this investigation, we designed cylindrical sensing rods with high sensitivity and developed installation procedures of semiconductor strain gages. The semiconductor strain gage has hish gage factor such that it can produce high resistance change in spite of low strain, but it is so small and fragile that one should handle carefully and sophisticated installation method is needed for good performances. The prototype transducers are manufactured, and then tested about three important factors: sensitivity, linearity, and hysteresis. We got results or 0.084 V/N sensitivity, 0.2% nonlinearity, and 0.5% hysteresis.

  • PDF

세라믹 다이어프램을 이용한 정전용량형 후막 스트레인 게이지 (Development of piezocapacitive thick film strain gage based on ceramic diaphragm)

  • 이성재;박하용;김정기;민남기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 C
    • /
    • pp.1529-1531
    • /
    • 2003
  • Thick film mechanical sensors can be categorized into four main areas piezoresistive, piezoelectric, piezocapastive and mechanic tube. In this areas, the thick film strain gage is the earliest example of a primary sensing element based on the substrates. The latest thick film sensor is used various pastes that have been specifically developed for pressure sensor application. The screen printing technique has been used to fabricate the pressure sensors on alumina substrate($Al_2O_3$). Thick film capacitive of strain sensing characteristics are reported and dielectric paste based on (Ti+Ba) materials. The electric property of dielectric paste has been studied and exhibit good properly with good gage factor comparable to piezoresistive strain gage. New piezocapacitive strain sensor was designed and tested. The output of capacitive value was good characteristics.

  • PDF