• 제목/요약/키워드: Gage block

검색결과 13건 처리시간 0.026초

디지탈 화상처리를 이용한 게이지 블록의 측정 자동화 (Automatic measurement of gage block using digital image processing)

  • Ko, Y.U.;Suh, H.S.;Eom, T.B.
    • 한국정밀공학회지
    • /
    • 제11권5호
    • /
    • pp.56-65
    • /
    • 1994
  • We have carried out a research on automatic measurement of gage blocks below 250mm and then improved the accuracy of the system, and reduced the measurement time using image processing technique and computer interface. The accuracy of the system is (230+10330 $L^{2}$)$^{2}$ nm (L:m) with confidence level of 95%. We participated APMP gage block intercomparision-1993/1994. The 1st round intercomparision showed that the measured values of all 5 gage blocks were within 21 nm from average.

  • PDF

광간섭법을 이용한 절대높이 측정 정밀도 향상에 관한 연구

  • 안근식;장경영;문희관
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1993년도 추계학술대회 논문집
    • /
    • pp.493-498
    • /
    • 1993
  • This paper proposes a high precision measurement technique to obtain the height of gage block. The proposed technique is consisted of two steps : In the first step, laser position transducer and electric micrometer are adopted to obtain a coarse value of the height of gage block, and then, second, heterodyne laser interferometry is adopted to acquire the precision value. The experiment results show that accuract in the order of a few nanometer is achieved for the gage blacks of as high as a few millimeter.

  • PDF

도플러방식과 헤테로다인 방식의 광간섭법을 병용한 절대높이 측정 정밀도 향상 (Improvement of Measurement Accuracy for Absolute Height by Using Two Types of Doppler and Heterodyne Optical Interferometry)

  • 안근식;장경영;문희관
    • 한국정밀공학회지
    • /
    • 제13권6호
    • /
    • pp.128-135
    • /
    • 1996
  • This paper proposes a high precision measurement technique to obtain the height of gage block with a few millimeter height. The proposed technique is consisted of two steps : In the first step, laser position transducer and electric micrometer are adopted to obtain a coarse value of the height of gage block, and then, in the second step, heterodyne laser interferometry is adopted to acquire the precision value. A new kind of phase detector is constructed in the low cost for the heterodyne interferometer and its linearity with ${\pm}1%$ is confirmed by experiment. Also measurement error factors due to enviroments are discussed and methodology to reduce such errors is proposed. Preliminary experiments are carried out for the gage blocks of as high as a few millimeter.

  • PDF

선형측정장치 개발 (Development of linear measuring system)

  • 엄태봉;김구영;정명세
    • 한국정밀공학회지
    • /
    • 제10권4호
    • /
    • pp.104-108
    • /
    • 1993
  • The linear length measurements are most frequently performed and should be most accurate among other parts in dimensional metrology. We developed the linear measuring system using a laser interferometer to improve the accuracy and to shorten the calibration time. The uncertainty of the system is 0.01 .mu. for 500mm steel gage block. The range of the measurement and resolution of the system are 1000mm and 0.01 .mu. m, respectively.

  • PDF

파랑에 의한 항내진동의 제어에 관한 실험적 연구 (Eaperimental Study on the Control of Harbor Oscillation due to Water Wave)

  • 최한규;이선용
    • 산업기술연구
    • /
    • 제14권
    • /
    • pp.101-107
    • /
    • 1994
  • This study is to investigate harbor oscillation phenomenon according to combination of the wall structures by model experiment in a three dimensional wave basin. Six different types of wall combination were chosen through combination of erect wall, erect dissipation block, and sand beach, wave height at selected points in the harbor were measured by electronic wave gage. Test results show that the wall structure composed solely of erect walls showed generally highest harbor oscillation. Since natural beach shows lower reflection than erect dissipation block do, we thought it would be more efficient to use natural beach for improved harbor oscillation. The result showed, however, that the erect dissipation block are more efficient than natural beach to attain less harbor oscillation. The reason seens that the erect dissipation blocks have better capability to control breaking wave on the surface of the structure.

  • PDF

카메라를 이용한 휴대폰 곡면유리의 높이측정 (Height Measurement of Cellphone Curved Glass using Camera)

  • 김한솔;이경준;정동연;이연형;김갑순
    • 제어로봇시스템학회논문지
    • /
    • 제22권12호
    • /
    • pp.1002-1010
    • /
    • 2016
  • This paper describes the design of a cellphone curved glass measuring device using by camera. The measuring device was composed of two camera, two backlight system, a body and so on, and the program was made for a camera calibration and noise removal, and also the program was made for height measurement of a cellphone curved glass using by subpixel algorism. And then a new technique for measuring the height of the cell phone curved glass was proposed. The characteristics test of height measurement of gage blocks and cell phone curved glasses was carried out, the error of the height measurement of gage block is less than ${\pm}0.005$ and the error of the height measurement of the cell phone curved glasses is less than ${\pm}0.005$. Thus it thought that the designed cellphone curved glass measuring device and the new technique for measuring the height was used to measure the height of the cellphone curved glass.

고농도 Out Gas 정량 분석법 개발

  • 김민주;김종윤;정기호;박창식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2009년도 추계학술대회 논문집
    • /
    • pp.13-13
    • /
    • 2009
  • 본 연구는 MLCC 구성성분의 증발/비등에 의한 저분자물질의 제거가 bar 수축에 미치는 영향도를 평가하기 위해, 압착 bar에서 발생하는 고농도의 out gas를 정량하기 위한 최적 system을 구축하고자 하였다. gas 포집에 범용적으로 사용하는 Purge & Trap sampler 대신 Heating block를 사용하여 gas를 발생시키고 동시에 solvent에 용해시킴으로써 고농도의 시료가 희석될 수 있는 전처리 장치를 디자인하였다. 그 결과 고농도 gas 주입에 의한 장비오염과 peak saturation 문제가 해결되었고, gas phase의 시료를 liquid phase로 상전이 시켜 autosampler를 이용한 정확한 량의 시료 주입이 가능하였다. System의 Gage Linearity와 Bias는 각각 1.7%와 1.3%로 개선이 필요없는 수준의 정확도를 가졌다.

  • PDF

아연도금 강재의 용접성에 미치는 돌기 성형 및 피복조건의 영향 (Effects of Projection Height and Post Treatment on the Resistance Projection Weldability of Zn Coated Sheet Steels)

  • 김기철;이목영
    • Journal of Welding and Joining
    • /
    • 제17권5호
    • /
    • pp.83-88
    • /
    • 1999
  • In this paper resistance projection weldability of Zn coated steels with post treatment has been discussed. Projection welding was performed by a condenser discharge type power source which was equipped with welding parameter monitoring system. Mechanical test results indicated that the effect of post coatings on the projection front changed showing very small very small spattering at the weld strength was negligible. However, contamination rate of the block electrode varied depending on the post treatment coatings. Test results also showed that projection height before welding should be kept to be 80-100% of the specimen thickness as far as the surface quality was taken into consideration. Based on the high speed photography, discharge condition at the beginning stage of the welding process. It was considered that the spattering reduced the weld strength slightly at the optimum heat input range.

  • PDF

두개의 전극도자를 사용하게 된 Permanent Transvenous Pacemaker Implantation: 1례 보고 (Permanent Transvenous Endocardial Pacemaker Inevitably Implanted Two Electrode Leads)

  • 곽문섭;이홍균
    • Journal of Chest Surgery
    • /
    • 제14권2호
    • /
    • pp.168-174
    • /
    • 1981
  • Since cardiac pacemaker was first totally implanted by Chardack, Gage and Greatbatch [1966], the electrical circuity of the cardiac pacemaker has been improved, modified, and refined. The problem of transvenous electrodes, however, is still remained; this may be due to electrode displacement, exit and/or entrance block, lead fracture and insulation defects. In permanent cardiac pacing, Irreversible loss of function of the transvenous electrode catheter eventually requires insertion of new lead. Authors now report one case that disclosed easy displacement of electrode tip in early phase of implantation and then two years and five months later, malfunctioning electrode could not be withdrawn from the cardiovascular system because it has become firmly enclosed by fibrous tissue along its course from the vein tract to the right ventricle. Under such circumstances, the electrode catheter tip was left in tricuspid annulus after being sutured at its entrance and burying the loop of lead in generator pocket. New other one electrode was then reimplantation through left external jugular vein.

  • PDF

평판두께와 연단거리를 변수로 갖는 박판탄소강 볼트접합부의 종국거동에 관한 실험적 연구 (An Experimental Study on Ultimate Behavior of Thin-walled Carbon Steel Bolted Connections with Varying Plate Thickness and End Distance)

  • 이용택;김태수;정하영;김승훈
    • 한국강구조학회 논문집
    • /
    • 제21권5호
    • /
    • pp.527-536
    • /
    • 2009
  • 본 연구의 목적은 박판 탄소강 일면전단 2행 2열 볼트접합부의 블록전단파단거동과 면외변형의 영향을 조사하는 것이다. 하중직각 방향 연단거리, 볼트직경, 피치, 게이지 치수를 고정하고 블록전단파단이 발생하도록 실험체를 계획한다. 접합평판의 두께, 하중방향연단거리를 주요변수로 설정한다. 단순인장 실험을 실시하고 블록전단파단 양상, 최대내력을 현행의 설계기준식에 의한 예측치와 비교한다. 또한, 판 두께와 연단거리에 따른 하중방향과 직각방향으로 발생하는 면외변형의 발생조건을 조사하고 면외변형의 발생으로 인한 내력저하정도를 고찰한다.