• Title/Summary/Keyword: Gage R&R study

Search Result 50, Processing Time 0.023 seconds

A Statistical Program for Measurement Process Capability Analysis based on KS Q ISO 22514-7 Using R (R을 이용한 KS Q ISO 22514-7 측정 프로세스 능력 분석용 프로그램)

  • Lee, Seung-Hoon;Lim, Keun
    • Journal of Korean Society for Quality Management
    • /
    • v.47 no.4
    • /
    • pp.713-723
    • /
    • 2019
  • Purpose: The purpose of this study is to develop a statistical program for capability analysis of measuring system and measurement process based upon KS Q ISO 22514-7. Methods: R is a powerful open source functional programming language that provides high level graphics and interfaces to other languages. Therefore, in this study, we will develop the statistical program using R language. Results: The R program developed in this study consists of the following five modules. ① Measuring system capability analysis with Type 1 study data: MSCA_Type1.R ② Measuring system capability analysis with Linearity study(Type 4 study) data: MSCA_Type4.R ③ Measurement process capability analysis with Type 1 study & Gage R&R study data: MPCA_T1GRR.R ④ Measurement process capability analysis with Type 4 study & Gage R&R study data: MPCA_T4GRR.R ⑤ Attribute measurement processes capability analysis : AttributeMP.R Conclusion: KS Q ISO 22514-7 evaluates measuring systems and measurement processes on the basis of the measurement uncertainty that was determined according to the GUM(KS Q ISO/IEC Guide 98-3). KS Q ISO 22514-7 offers precise procedures, however, computations are more intensive. The R program of this study will help to evaluate the measurement process.

Application of Taguchi's Robust Design Method in Optimization of Measuring Electrical Properties on Acupoints: A Pilot Study (Taguchi 실험계획법을 이용한 경혈점의 피부전기특성 최적화조건 선정 : A Pilot Study)

  • Nam, Tong-Hyun;Shin, Sang-Hoon
    • Korean Journal of Acupuncture
    • /
    • v.25 no.3
    • /
    • pp.15-27
    • /
    • 2008
  • Objectives : The objective of the current study is to optimize an acupoint electrical property measurement system by using the procedures and strengths of the Taguchi method. Methods : Taguchi method was applied in the optimization of the acupoint electrical property measurement system, as in the following steps: (1) determine evaluation index; (2) execute the 1st gage R&R; (3) identify controllable and uncontrollable factors; (4) design Taguchi crossed array layout; (5) execute experiments according to trial conditions; (6) analyze testing results; (7) determine optimum run; (8) execute the 2nd gage R&R; (9) confirm optimum run. Results : The results showed that electrodes with larger diameter and efferent electric current, with music played, can produce the larger different electrical conductivity between the acupoints and the non-acupoints under various conditions. Taguchi process optimization improved repeatability and reproducibility of the acupoint electrical property measurement system. Conclusions : In the optimized condition, repeatability and reproducibility of the acupoint electrical property measurement system was acceptable.

  • PDF

A Quantitative Method for Human Face Volume Using 3D Optical Measurement (3D 측정 기기를 이용한 얼굴의 부피 정량법 연구)

  • Park, Shin-Young;Nam,, Gae-Won;Kim, Seung-Hun;Lee, Hea-Kang;Ahn, Sung-Yeon;Moon, Seong-Joon;Kim, Han-Kon
    • Journal of the Society of Cosmetic Scientists of Korea
    • /
    • v.34 no.4
    • /
    • pp.333-338
    • /
    • 2008
  • The evaluation for the visage volume was performed with human and dummy face using PRIMOS $body^{(R)}$. Three researchers measured the dummy face attached different volume of clay (6.6 mL, 13.2 mL, and 19.8 mL). It is identified that the high correlation between measured values and real volume ($R^2=0.99$). The percent (%) of relative standard deviation (RSD) of the data was shown below 10%. In Gage R&R analysis, the percent of contribution, the percent of study variation and distinct categories values were 0.78%, 8.85%, and 15% respectively. Therefore this method was regarded as the good standard condition in aspect of reproducibility and repetitiveness of data. The face volume variation was measured by PRIMOS $body^{(R)}$ on the face in participated 10 healthy Korean women volunteers. Subjects used the product once a day for two weeks as night sleeping pack. After application of the test products, the 3D image data of face were taken 1 and 2 weeks later. We found the face volume was significantly decreased after using products. In conclusion, this novel non-invasive technique was useful in measuring and visualizing alterations in face volume as a consequence of certain treatments. This system will provide a rapid and precise analysis of 3D topographical information for face.

The Measurement of Membrane Deformation Behavior in Kogas Pilot LNG Storage Tank by the use of Mechanical/Electrical Sensor (I) (기계적/전기적 측정 센서를 이용한 Kogas Pilot LNG 저장탱크 멤브레인 변형 거동 측정(I))

  • Kim Y.K.;Hong S.H,;Oh B.T.;Yoon I.S.;Kim J.H.;Kim S.S.
    • Journal of the Korean Institute of Gas
    • /
    • v.7 no.3 s.20
    • /
    • pp.13-17
    • /
    • 2003
  • A membrane unit for Liquefied Natural Gas (LNG) storage tank is a structural member which is designed specifically for preventing undesirable LNG leakage. Membrane units have to endure gas and liquid pressures by LNG and thermal stresses by the contact with cryogenic liquid of $-162^{\circ}C$. It is of importance to assure the strengths of membrane by experimental stress analysis under the temperature of LNG. In this paper, we proposed measurement system using commercial electrical strain gage and mechanical extension meter designed for this study.

  • PDF

Reliability Measurement of the Ultrasound for Safety of the Abdominal Organs on Acupuncturing Sangwan (CV13) (상완혈 자침시 복부 장기의 안전성 확보를 위한 초음파시스템의 신뢰도 측정)

  • Kim, Ji-Hye;Baek, Tae-Hyeun
    • The Journal of the Society of Korean Medicine Diagnostics
    • /
    • v.15 no.2
    • /
    • pp.203-214
    • /
    • 2011
  • Objectives: The objective of the current study is to determine whether an ultrasound device system is adequate for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver. Methods: We recruited 3 healthy young male subjects and 2 sonographers. The each sonographer measured vertical shortest distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with a ultrasound device with three methods of 3.5 MHz convex probe and gel, 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad, three times in random order. Because the total variation could be divided into repeatability, reproducibility and subject-to-subject variation in Gage R&R method, we compared the sources of variation associated with the measurement system with an analysis of variance model. Results & Conclusions: Number of distinct categories is calculated on the basis of standard deviation of subject-to-subject divided by standard deviation of total Gage R&R. If the number of categories is five or more, the measurement system may be acceptable for the analysis of the process. The number of distinct categories of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver were 9.20 (9 MHz linear probe and gel), 14.70 (9 MHz linear probe and solid gel pad). So we concluded that repeatabilities and reproducibilities of the ultrasound device system for measuring distance from the abdominal surface of Sangwan (CV13) to peritoneum in front of anterior surface of liver with the methods of 9 MHz linear probe and gel, and 9 MHz linear probe and solid gel pad were acceptable.

A study on consistency and accuracy of pulse diagnosis in Eight-Constitution Medicine

  • Shin, Yong-Sup;Nah, Seong-Su;Oh, Hwan-Sup;Park, Young-Jae;Park, Young-Bae
    • Advances in Traditional Medicine
    • /
    • v.9 no.1
    • /
    • pp.14-19
    • /
    • 2009
  • The aim of this study is to evaluate appraiser's consistency and accuracy about pulse diagnosis (PD) in discrimination of eight-constitutions using Gage R&R study. Cumulative numbers of PD for discrimination of eight constitutions of three appraisers' experience were 75,000 cases, 50,000 cases, 1,100 cases, respectively. Three Appraisers diagnosed subject's eight-constitutions by PD with blinded method. Gage R&R study was used to verify the results. In the measurements of consistency, appraiser B (agreement = 80%, Value of k = 0.8276) was very good, appraiser A (agreement = 70%, Value of k = 0.7465) was good, and appraiser C (agreement = 50%, Value of k = 0.5365) was moderate. In the measurements of accuracy, appraiser B (agreement = 70%, Value of k = 0.6812) was good, appraiser A (agreement = 60%, Value of k = 0.6414) was good, and appraiser C (agreement = 0%, Value of k = -0.1000) was poor. The results suggest that accuracy of discrimination of constitutions relatively depend on experience and number of cases of PD. Further large controlled study is needed to evaluate the accuracy of PD.

A Statistical Software for Measurement Systems Analysis (측정시스템 분석용 통계소프트웨어의 개발)

  • 이승훈;이종환
    • Journal of Korean Society for Quality Management
    • /
    • v.28 no.1
    • /
    • pp.175-195
    • /
    • 2000
  • In this study, we developed a statistical software for measurement systems analysis. This software is patterned after the Measurement Systems Analysis Reference Manual developed by the Automotive Industry Action Group (AIAG). This software includes stability analysis, bias and linearity analysis, and gage R&R studies. This software was developed by using Delphi(version 4.0) and can be implemented on MS Windows 95 or higher level.

  • PDF

A study on crack opening behavior of small fatigue crack in Al 2024-T3 material using computerized interferometric strain/displacement gage (계장화 미소변위 측정기를 이용한 Al 2024-T3 소재의 미소피로 균열의 열림특성연구)

  • 이주진;남승훈;허용학;임대순;윤성기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.14 no.6
    • /
    • pp.1576-1582
    • /
    • 1990
  • To examine small fatigue crack behavior, the crack opening displacement (COD) was measured for surface cracks in the range of few tens to hundreds .mu.m using the computerized Interferometric Strain/Displacement Gage (ISDG) which could measure the relative displacement with a resolution of 0.02 .mu.m. The load-COD record is stored and analyzed after the test to determined the opening load. Single-edge notched specimens, 2.3mm thick, of Al 2024-T3 were precracked at load ratios of 0.0, -1.0 and -2.0 to make small fatigue cracks. The opening loads were measured these small cracks and compared with those of long cracks. The opening load ratios for the short cracks are about 10% smaller than those for long cracks at positive R-ratios, but are about 100% smaller at negative R-ratios.

Development of Contact-Type Thickness Measurement Machine using LVDT Sensors (LVDT센서를 이용한 접촉식 두께자동측정기 개발)

  • Shin, Ki-Yeol;Hwang, Seon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.14 no.4
    • /
    • pp.151-159
    • /
    • 2015
  • In this study, we developed an automated contact-type thickness measurement machine that continuously and precisely measures the thickness of a PCB module product using multi-LVDT sensors. The system contains a measurement part to automatically measure the thickness in real time according to the set conditions with an alignment supply unit and unloading unit to separate OK and NG products. The sensors were calibrated before assembly in the measuring machine, and precision and accuracy performance tests were also performed to reduce uncertainty errors in the measurement machine. In the calibration test, the precision errors of the LVDT sensor were determined to be $1-3{\mu}m$ as 0.1% at the measuring range. A measurement error of 0.8 mm and 1.0 mm thickness test standards were found to be $1{\mu}m$ and $4{\mu}m$, and the standard deviations of two 1.0 mm products were measured as $14{\mu}m$ and $8{\mu}m$, respectively. In the measurement system analysis, the accuracies of test PCB standards were found to be $2{\mu}m$ and $3{\mu}m$, respectively. From the results of gage repeatability and reproducibility (R & R) crossed, we found that the machine is suitable for the measurement and process control in the mass production line as 7.92% of total gage R & R and in seven distinct categories. The maximum operating speed was limited at 13 pcs/min, showing a value good enough to measure.