• Title/Summary/Keyword: GRID

Search Result 9,461, Processing Time 0.034 seconds

Interpretation Works and Online Terminology Information System for the Standardization of Smart Grid Terminologies (스마트그리드 용어 표준화를 위한 뜻풀이 작업 및 온라인 용어 정보시스템 개발)

  • Hwang, Humor;Kim, Jung-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.3
    • /
    • pp.293-299
    • /
    • 2013
  • Power system technologies in the area of smart grid are being converged with communication system technologies or information technologies(IT). This interdisciplinary action affects on two parts vigorously so that IT has become a essential part of power industry. But terminologies of two parts are confused and it is necessary that these are standardized to develop the industry. The interpretation works with scientific and technological standard of the smart grid terminologies which are IEC TC 57 glossary and non-glossary terminologies are introduced. Based on the interpretation works of the smart grid terminologies, an online terminology information system for the standardization of smart grid terminologies is proposed. The system provides the capability of collection and delivery of academic society opinions for the selected and interpreted terminologies.

Performance Analysis and Test on the KAERI Designed Spacer Grids for the PWR (한국원자력연구소에서 개발한 가압경수로용 핵연료 지지격자의 성능 해석 및 시험)

  • Song, K.N.;Yoon, K.H.;Kang, H.S.;Choi, M.H.;Chun, T.H.
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.432-437
    • /
    • 2004
  • KAERI has contrived 16 kinds of spacer grid shapes of its own since 1997 and applied for domestic and foreign patents. To date, KAERI has obtained US and ROK patents for 11 kinds of spacer grid shapes among them and the others are under review in USA, EC, China, and ROK. In this study, detailed performance analysis and test on two spacer grid shapes that are assumed to be the most effective candidates for the spacer grid of the next generation nuclear fuel in Korea was carried out. The result has shown that the performances of the candidates are better or not worse than those of the current spacer grid.

  • PDF

Effects of Natural Independent Visual Background for Reducing Simulator Sickness (자연형 IVB(Independent Visual Background)의 Simulator Sickness 감소효과)

  • 김도회;임정위
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.25 no.3
    • /
    • pp.28-33
    • /
    • 2002
  • Several studies indicated that an independent visual background (IVB) reduced simulator sickness (SS) and balance disturbance associated with exposure to virtual environments (VEs) and motion simulators. A recent study showed that an IVB comprised of an earth-fixed grid was less effective in a complex driving simulator than in a simple VE. Subjects' post-experiment reports indicated that the VE motion "induced" motion of the earth-fixed grid m. This led to the suggestion that an IVB comprised of clouds would be less subject to induced motion and therefore would alleviate nausea more effectively than a grid IVB. Clouds are "natural" and are usually perceived as relatively stable, whereas a grid has no inherent stability. 12 subjects were exposed to complex motion through a simulated environment in a driving simulator under 3 IVB conditions: grid, less clouds, many clouds. They reported less nausea when the many-cloud IVB was used relative to the grid IVB condition. grid IVB condition.

Performance Improvement of Grid-Connected Inverter Systems under Unbalanced and Distorted Grid Voltage by Using a PR Controller

  • Lee, Jong-Hyun;Jeong, Hae-Gwang;Lee, Kyo-Beum
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.6
    • /
    • pp.918-925
    • /
    • 2012
  • This paper proposes a control method for grid-connected inverter systems under unbalanced and distorted grid voltage. The proposed method can reduce the power ripple caused by the unbalanced condition and compensate for the low-order harmonics of the output currents caused by the distortion of grid voltage. To reduce the power ripple, our method replaces the two conventional PI controllers with one PR controllers in the stationary frame. PR controllers can implement selective harmonic compensation without excessive computational requirements; the use of these controllers simplifies the method. Both the simulated and experimental results agree well with the theoretical analysis.

Study of Touch and Step Voltages with Grounding Grid Using Electrolytic Tank and Analysis Program

  • Gil, Hyoung-Jun;Kim, Hyang-Kon;Kill, Gyung-Suk
    • International Journal of Safety
    • /
    • v.9 no.2
    • /
    • pp.1-5
    • /
    • 2010
  • In order to analyze the potential rise of ground surface of grounding grid installed in buildings, the grounding simulator has been designed and fabricated as substantial and economical measures. This paper describes the study of touch and step voltages with grounding grid where earth leakage current is injected. To assess risk voltage of grounding grid, the grounding simulator and CDEGS program were used to obtain measured data and theoretical results of this study. The grounding simulator was composed of an electrolytic tank, AC power supply, a movable potentiometer, and test grounding electrodes. The potential rise was measured by grounding simulator, and the touch and step voltages were computed by CDEGS program. As a consequence, the touch voltage and step voltage above the grounding grid were very low, but were significantly increased near the edge of grounding grid.

Analysis of Phase Error Effects Due to Grid Frequency Variation of SRF-PLL Based on APF

  • Seong, Ui-Seok;Hwang, Seon-Hwan
    • Journal of Power Electronics
    • /
    • v.16 no.1
    • /
    • pp.18-26
    • /
    • 2016
  • This paper proposes a compensation algorithm for reducing a specific ripple component on synchronous reference frame phase locked loop (SRF-PLL) in grid-tied single-phase inverters. In general, SRF-PLL, which is based on all-pass filter to generate virtual voltage, is widely used to estimate the grid phase angle in a single-phase system. In reality, the estimated grid phase angle might be distorted because the phase difference between actual and virtual voltages is not 90 degrees. That is, the phase error is caused by the difference between cut-off frequency of all-pass filter and grid frequency under grid frequency variation. Therefore, the effects on phase angle and output current attributed to the phase error are mathematically analyzed in this paper. In addition, the proportional resonant (PR) controller is adapted to reduce the effects of phase error. The validity of the proposed algorithm is verified through several simulations and experiments.

Voltage Distortion Approach for Output Filter Design for Off-Grid and Grid-Connected PWM Inverters

  • Husev, Oleksandr;Chub, Andrii;Romero-Cadaval, Enrique;Roncero-Clemente, Carlos;Vinnikov, Dmitri
    • Journal of Power Electronics
    • /
    • v.15 no.1
    • /
    • pp.278-287
    • /
    • 2015
  • This paper proposes a novel voltage distortion approach for output filter design based on the voltage transfer function for both off-grid and grid-connected Pulse Width Modulation (PWM) Inverters. The method explained in detail is compared to conventional methods. A comparative analysis is performed on an example of L and LCL-filter design. Simulation and experimental results for the off-grid and the grid-connected single phase inverter prove our theoretical predictions. It was found that conventional methods define redundant values of the output filter elements. Assumptions and limitations of the proposed approach are also discussed.

Observer-based Voltage Sensorless Control Scheme for an LCL-filtered Grid-connected Inverter

  • Lai, Ngoc Bao;Kim, Kyeong-Hwa
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.266-267
    • /
    • 2017
  • To synchronize the distributed generation (DG) unit with the grid, the voltage sensors are generally employed to obtain the grid phase angle. This paper presents an observer-based voltage sensorless control scheme for a three-phase inverter connected to the grid through an LCL filter. The proposed control scheme consists of an augmented state observer and a feedback controller. The augmented state observer is used to estimate the grid voltages and states of the inverter system, which are then employed to determine the grid voltage angle and to construct the feedback controller. As a result of using the observer, only the grid current sensors are required to accomplish the control scheme. The simulation results are given to prove the validity of the proposed control scheme.

  • PDF

Smart Grid and Its Implications for Electricity Market Design

  • Kim, Seon-Gu;Hur, Seong-Il;Chae, Yeoung-Jin
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.1-7
    • /
    • 2010
  • Recently, smart grid has been considered a very important new energy delivery technology, and one that can help ensure a cleaner environment by making use of information and communication technology (ICT) in countries around the world. The many technological benefits smart grid offers is expected to bring about a huge change in the electric energy supply chain. In particular, smart grid with advanced ICT is likely to allow market agents to participate in the decision-making process in the restructured electricity industry, easily facilitating Homeostatic Utility Control. In this paper, we examine smart grid as a market externality, and then illustrate issues from the commercial market perspective as it relates to electricity market design. Finally, our paper identifies some of the impacts of smart grid on electricity market design, which may possibly be incorporated into the evolution of the electricity market, thus ensuring market efficiency.

An Active Feedforward Compensation for a Current Harmonics Reduction in Three-phase Grid-connected Inverters (3상 계통 연계형 인버터에서의 전류 고조파 감쇄를 위한 능동형 피드포워드 보상 기법)

  • Park, Byong-Jun;Kim, Rae-Young;Choi, Ki-Young
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • This paper proposes a current harmonic compensation method for the grid-connected inverter, especially caused by the grid impedance. Grid impedance causes low order harmonics in the grid current and deteriorates power quality. This paper analyzes the negative impact of the grid impedance, and proposes an active feedforward compensation method. Proposing method verified through simulation and experiment with 3-phase 1.5kW voltage source inverter prototype.