• Title/Summary/Keyword: GRID

Search Result 9,461, Processing Time 0.034 seconds

Evaluation of Optimal Grid Resolution for Hydrodynamic Proper Simulation (수리동역학적 모의를 위한 적정 격자해상도 산정방법)

  • Ahn, Jung-Min;Park, In-Hyeok;Lyu, Si-Wan;Hur, Young-Teck
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.20 no.1
    • /
    • pp.109-116
    • /
    • 2012
  • The effect of the grid resolution on the hydrodynamic simulation has been investigated by using CCHE2D and EFDC. Since a high resolution of the grid results in the increase of computation time, an appropriate grid resolution should be selected by considering the efficiency of simulation according to the objectives of projects. In order to understand the effect of grid resolution and determine the optimal grid resolution, several cases with different lateral grid resolutions have been simulated for the reach of Nakdong river at the confluence of Kumho river for the floods in 2006. Orthogonal curvilinear grids for the domain have been constructed from the survey products at the sections with the longitudinal interval of 20 m. Area-elevation curve and the comparison of simulated results with measured stage at the specific station have been used to check the effect of grid resolution. From the results, the existence of optimal grid resolution has been observed, which ensure both efficiency of computation and certainty of results.

Study on dose and image quality by Added filter and Grid change when exam abdominal fluoroscopy (복부투시조영 검사 시 Added filter와 Grid 변화에 따른 선량 및 화질에 관한 연구)

  • Hong, Seon Sook;Kang, Kyeong Mi;Seong, Min Suk;Lee, Jong Woong
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.14 no.2
    • /
    • pp.47-56
    • /
    • 2012
  • Amount of radiation exposure by seeing through fluoroscopy examination while is many patient exposure administration and unprepared misgovernment be. In this study, abdominal fluoroscopy during the scan, the dose and image quality change according to the use of grid and added filter optimized by measuring the test condition is proposed. Uses seeing through fluoroscopy examination equipment of Image Intensifier of Easy Diagnost Eleva (Philips), under tube type and uses Human phantom and measures average area dose according to grid insertion existence and nonexistence and added filter kind change. Measure sum of 29 organ dose and effective dose through PCXMC imagination simulation program and image J program through noise, SNR, image distortion was measured. Resolution, sharpness, and analyzed using the MTF curves. Fluorography the grid to insert the filter thickness and thickening and increased the average area dose and organ doses and effective dose. In the case of spot examination, when inserted grid, average area dose and organ dose and effective dose increased. Filter thickens the average area dose decreased, but the organ doses and effective dose were increased when use 0.2mmCu+1mmAl filter, decreased slightly. Noise and SNR measurements without inserting the gird, if you do not use the added filter was the lowest and when measure the distortion, 0.1mmCu+1mmAl filter was no difference of image quality in case insert grid was judged that when did not use occasion added filter that do not use grid, difference of image quality does not exist. Did not show a big difference, according to the grid and uses of the added filter sharpness, and resolution. Patient dose increases with factors that reduce the quality of the image so reckless grid and the use of the added filter when abdominal fluoroscopy examination should be cautious in using.

  • PDF

A Direction of Convergence and Security of Smart Grid and Information Communication Network (스마트그리드(Smart Grid) 전력망과 정보통신망 융합 보안 방향)

  • Seo, Woo-Seok;Jun, Moon-Seog
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.5 no.5
    • /
    • pp.477-486
    • /
    • 2010
  • This Study suggests security directions to reconstruct separate network of Smart Grid and information communication network as one communications system and implement Smart Grid integrated information communication network. In addition, it suggests prevention directions to prevent future cyber attacks by reorganizing network as the key three-stage network and separating TCP/IP four layers that consist of existing information communication network from Smart Grid. Moreover, it suggests the foundation for the study and the test by providing current problems of Smart Grid, weak points, and three security models. This study is meaningful to suggest development directions and situations as a technology of future-oriented electric industries, integrate attacks and preventions of TCP/IP Layers with Smart Grid, and seek for a new technology of Smart Grid and future tasks for Smart Grid information security.

Research on a Multi-Objective Control Strategy for Current-source PWM Rectifiers under Unbalanced and Harmonic Grid Voltage Conditions

  • Geng, Yi-Wen;Liu, Hai-Wei;Deng, Ren-Xiong;Tian, Fang-Fang;Bai, Hao-Feng;Wang, Kai
    • Journal of Power Electronics
    • /
    • v.18 no.1
    • /
    • pp.171-184
    • /
    • 2018
  • Unbalanced and distorted grid voltages cause the grid side current of a current source PWM rectifier to be heavily distorted. They can also cause the DC-link current to fluctuate with a huge amplitude. In order to enhance the performance of a current-source PWM rectifier under unbalanced and harmonic grid voltage conditions, a mathematical model of a current-source PWM rectifier is established and a flexible multi-objective control strategy is proposed to control the DC-link current and grid-current. The fundamental positive/negative sequence, $5^{th}$ and $7^{th}$ order harmonic components of the grid voltage are first separated with the proposed control strategy. The grid current reference are optimized based on three objectives: 1) sinusoidal and symmetrical grid current, 2) sinusoidal grid current and elimination of the DC-current $2^{nd}$ order fluctuations, and 3) elimination of the DC-current $2^{nd}$ and $6^{th}$ order fluctuations. To avoid separation of the grid current components, a multi-frequency proportional-resonant controller is applied to control the fundamental positive/negative sequence, $5^{th}$ and $7^{th}$ order harmonic current. Finally, experimental results verify the effectiveness of proposed control strategy.

Evaluation Criteria for Korean Smart Grid based on K-ISMS (K-ISMS 기반의 한국형 스마트 그리드 정보보호 관리체계 평가 기준 제안)

  • Kim, Kichul;Kim, Seungjoo
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.22 no.6
    • /
    • pp.1375-1391
    • /
    • 2012
  • Smart grid is a next-generation intelligent power grid that applying ICT to power grid to maximize the energy efficiency ratio. Recently, technologies and standards for smart grid are being developed around the world. Information security which is an essential part of smart grid development has to be managed continuously. Information security management system certification for organizational risk management has been implemented in Korea. Although preparation for information security management system certification which is applicable to smart grid is considered, there are no specific methods. This paper is to propose core and added evaluation criteria for Korean smart grid based on K-ISMS through comparative analysis between ISMS operated in Korea and smart grid information security management system developed in the United States. Added evaluation criteria enable smart grid related business that certified existing ISMS to minimize redundant and unnecessary certification assessment work.

Hexagonal Grid Shadow Generation using Bézier Curves (베지어 곡선을 활용한 육각 그리드의 그림자 생성 방법)

  • Minseok Kim;Taekgwan Nam;Youngjin Park
    • Smart Media Journal
    • /
    • v.12 no.4
    • /
    • pp.47-57
    • /
    • 2023
  • The hexagonal grid structure has been studied for processing and representing spatial information data in Geographic Information Systems. Visualization using a hexagonal grid has high visibility compared to other grid representation methods. However, it is difficult to effectively convey quantitative data and differences between grids depending on the geospatial data represented. In this paper, we propose a method to visually emphasize the hexagonal grid by generating shadow on the outside of the hexagonal grid. To do so, we offset the outer line segments of the hexagonal grid to be emphasized and generate a Bézier curve based on that information to determine the final shadow shape. We also apply variable transparency toward the edges of the shadow because the shadow gradually fades away from the hexagonal grid. We have shown that the proposed method can effectively generate shadow areas given not only a single hexagonal grid but also multiple hexagonal grids and can generate various shadow shapes based on user interface inputs. We apply the proposed method to Yongsan-gu, one of the districts of Seoul, and show the results of visually emphasizing it after generating shadow using the proposed method.

Improved DPC Strategy of Grid-connected Inverters under Unbalanced and Harmonic Grid Conditions

  • Shen, Yongbo;Nian, Heng
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.2
    • /
    • pp.169-175
    • /
    • 2014
  • This paper presents an improved direct power control (DPC) strategy for grid-connected voltage source inverter (VSI) under unbalanced and harmonic grid voltage conditions. Based on the mathematic model of VSI with the negative sequence, 5th and 7th harmonic voltage components consideration, a PI controller is used in the proposed DPC strategy to achieve the average output power regulation. Furthermore, vector PI controller with the resonant frequency tuned at the two times and six times grid fundamental frequency is adopted to regulate both negative and harmonic components, and then two alternative targets of the balanced/sinusoidal current and smooth active/reactive output power can be achieved. Finally, simulation results based on MATLAB validate the availability of the proposed DPC strategy.

Power Flow Study of Low-Voltage DC Micro-Grid and Control of Energy Storage System in the Grid

  • Kim, Dong-Eok
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.2
    • /
    • pp.549-558
    • /
    • 2017
  • DC distribution has several differences compared to AC distribution. DC distribution has a higher efficiency than AC distribution when distributing electricity at the same voltage level. Accordingly, power can be transferred further with low-voltage DC. In addition, power flow in a DC grid system is produced by only a voltage difference in magnitude. Owing to these differences, operation of a DC grid system significantly differs from that of an AC system. In this paper, the power flow problem in a bipolar-type DC grid with unbalanced load conditions is organized and solved. Control strategy of energy storage system on a slow time scale with power references obtained by solving an optimization problem regarding the DC grid is then proposed. The proposed strategy is verified with computer simulations.

DC Injection Control for Grid-Connected Single-Phase Inverters Based on Virtual Capacitor

  • Wang, Wei;Wang, Ping;Bei, Taizhou;Cai, Mengmeng
    • Journal of Power Electronics
    • /
    • v.15 no.5
    • /
    • pp.1338-1347
    • /
    • 2015
  • DC injection is a critical issue in transformerless grid-connected inverters. DC injection control based on virtual capacitor has the advantages of low cost, low loss, high accuracy and easy implementation. In this paper, the principle of DC injection control based on virtual capacitor was analyzed. In addition, the applicable conditions, working process, steady state error and advantages were also discussed in detail. The design of the control parameters based on virtual capacitor was proposed in a grid-connected inverter with LCL filter. The robustness of the control parameters was also discussed. Simulation and experimental results verify the validity of the analysis and demonstrate that this research has a certain value in engineering applications.

Grid Connected Inverter of ESS for Seamless mode Transition (분산 발전 시스템에서 계통연계 인버터의 매끄러운 모드 전환)

  • Hong, Chang-Pyo;Kim, Hag-Wone;Cho, Kwan-Yuhl
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.4
    • /
    • pp.364-372
    • /
    • 2016
  • In this paper, a voltage controller for the seamless transition of a grid-connected inverter for ESS is proposed. The single-phase inverter is operated as a current controller when the grid is connected and as a voltage controller in the stand-alone mode when the grid is disconnected. Generally, in the case of grid recovery, the overcurrent may flow into the system because of the mismatch phase between the inverter output and grid voltages. The proposed controller resolves the overcurrent problem through phase delay problems with initial value feed-forward control of the integrator when the grid voltage is restored. The effects of the control method are simulated through PSIM, and the usefulness of the control method is verified through experiments.