• Title/Summary/Keyword: GPS-X 시뮬레이션

Search Result 17, Processing Time 0.02 seconds

The Process Control Using Modeling Technique in A2O Sewage Treatment Process (모델링기법을 이용한 A2O 하수처리공정에서 주요 공정관리에 관한 연구)

  • Park, Jung Soo;Kim, Sung Duk;Seung, Dho Hyon
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.2
    • /
    • pp.65-75
    • /
    • 2020
  • The efficiency of sewage treatment was ananlyzed selecting a sewage treatment plant in Gyeonggi-do where A2O process was applied. Statistical techniques based on the operation data of the sewage treatment were used. The main factors directly affecting the efficiency of the treatment process were analyzed using a GPS-X model. The correlation analysis and one-way ANOVA were performed. The T-N and NH4+-N values of the effluent did not generate statistically significant level (p-value:>0.05) when compared with C/N ration values. Removel of nitrogen components form sewage treatment plants were affected by temperature, HRT, SRT and DO. In the case of BOD, all operating factors were affected, while COD was affecte by factors of HRT, STR and DO. In simulations using GPS-X, the parameters that greatly influence was included the maximum sedimentation rate, the dependent nutrient microbial yield (anoxic), the phosphorus saturation coefficient, the dependent nutrient microbial killing rate, the dependent nutrient microbial maximum growth rate, and the independent trophic microorganisms. The maximum growth rate and the maximum setting rate were identified.

A study on the improvement for advanced wastewater treatment of rural community sewage treatment plant using GPS-X (PS-X을 이용한 소규모 마을하수도처리시설의 고도처리개선 연구)

  • Gu, Bon-Woo;Oh, Dea-Min;Lee, Young-Shin;Choi, Gun-Youl;Yang, Jong-Woon;Lee, Jung-Chul
    • Proceedings of the KAIS Fall Conference
    • /
    • 2009.05a
    • /
    • pp.855-858
    • /
    • 2009
  • 우리나라 농어촌 지역은 경제 발전과 함께 식생활의 개선 및 주택 개량, 수세식 화장실 보급 확대등으로 생활 오수 발생량이 크게 늘고 있는 실정이다. 이에 1994년부터 정부는 하수도법에 의한 수질개선 대책 사업등으로 마을 하수도 사업이 진행되어 왔으나, 현재 몇몇 농어촌 지역의 마을하수도 시설의 노후화 및 처리용량 부적합 등으로 현재 질소, 인의 처리효율이 방류수 수질기준에 적합하지 못하여 주변 수역의 수질개선을 위한 고도처리개선이 필요한 실정이다. 따라서, 본 연구는 소규모 마을하수도처리시설에 적용하고자 하는 고도처리개선공정을 GPS-X(General Purpose Simulator) 시뮬레이션으로 계획수질을 추정하여 대상시설에 적합한 고도처리개선공정을 설계하였다. 측정결과, 각 반응조별 시뮬레이션에서 혐기조, 무산소조, SBR1, SBR2 모두 일정한 처리형태를 보였으며, 시뮬레이션을 통한 유출수 예측결과, SS의 경우 97.3%, BOD 97.5%, TCOD 87.3%, TP 81.1%, TN 74.5%의 제거효율을 보여, 안정적인 고도처리효과를 나타내는 것으로 판단된다.

  • PDF

Roll Angle Estimation of a Rolling Airframe Using a GPS and a Roll Rate Gyro (단일 GPS와 롤각속도계를 이용한 롤 회전 비행체의 롤자세각 추정)

  • Hong, Ju-Hyeon;Kim, Dusik;Ryoo, Chang-Kyung;Lee, Chang-Hun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.43 no.2
    • /
    • pp.133-140
    • /
    • 2015
  • In this paper, a roll angle estimation method of a rolling airframe using a low grade GPS and a roll rate gyro is proposed. The strength of the received signal of the GPS antenna attached on the rolling airframe is maximized when the GPS satellite is placed on the plane determined by the x-axis of the rolling airframe and the GPS antenna axis. Under the assumption that the x-axis of the rolling airframe is coincident with its velocity vector, the roll angle of the rolling airframe is calculated from the relative position vector of the satellite to the GPS when the GPS signal strength becomes maximum. The Kalman filter combined with a roll rate gyro is introduced to increase the determination accuracy of the roll angle. The performance of the proposed method is verified via 6-DOF simulations.

Evaluation of External Carbon Source on the 2 Stage Denitrification Process by Simulation of GPS-X (GPS-X 시뮬레이션을 이용한 2단탈질 공정에서 외부탄소원 적용성 평가)

  • Chung, Chang-Wha;Shim, Yu-Seop;Kim, Tae-Hyung;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.1
    • /
    • pp.37-48
    • /
    • 2004
  • The purpose of this study was to evaluate adaptability of external carbon source using GPS-X program in pilot plant composed with 2-stage denitrification process. The result from analysis of pilot plant operation and GPS-X simulation showed that effluent concentration could be simulated similarly by modifying operation conditions, such as DO concentration, C/N ratio and other calibrated parameter. In order to satisfy the standard of the effluent water quality on T-N of 20mg/L, it required approximately 3.1 of C/N ratio and 50% of nitrogen removal efficiency when influent T-N is 36.9mg/L. To maintain the stable water quality of the receiving water, the effluent T-N concentration should be less than 10-15mg/L and the appropriate C/N ratio to remove nitrogen was 4.27-6.82. The analysis of sensitivity to kinetic coefficient and reaction constant showed that $Y_H$ and ${\mu}_{mAUT}$ were most sensitive to nitrate and ammonia nitrogen, relatively and sensitivity coefficient of their were 1.32, 1.98. It was concluded that as $Y_H$ decreased and ${\mu}_{mAUT}$ increased, the reaction rates of denitrification and nitrification increased and the removal efficiencies of $NO_3{^-}-N$ and $NH_4{^+}-N$ improved.

A Study on Optimum HRT Combination for Efficient Nitrogen Removal at WWTP in Winter Days (동절기 하수처리장에서 효율적인 질소제거를 위한 최적 HRT조합 도출에 관한 연구)

  • Gil, Kyung-Ik;Lee, Un-Gil;Rho, Hae-Yeon
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.8 no.3
    • /
    • pp.165-169
    • /
    • 2008
  • It has been reported that most wastewater treatment plants have difficulties in nitrogen removal during winter season due to declined activity of nitrifiers in the condition of low temperature. This study was conducted in order to find out optimum operating condition for efficient nitrogen removal in low temperature. A series of operating conditions with various HRTs of each tank were simulated using the GPS-X program. The optimum HRT combination for effective nitrogen removal was 0.3 hr/0.5 hr/1.36 hr/4.84 hr(PreAx/An/Ax/Ox) with 51.4% of T-N removal efficiency and 57.3% of $NH_4^+$-N removal efficiency.

Polling Scheme Adapted to Unbalanced Traffic Load in IEEE 802.11x Wireless LAN (IEEE 802.11x Wireless LAN에서 불균형한 트래픽 부하에 적응적인 폴링 기법)

  • Shin Soo-Young;Park Soo-Hyun
    • The KIPS Transactions:PartC
    • /
    • v.12C no.3 s.99
    • /
    • pp.387-394
    • /
    • 2005
  • Every MAC (Medium Access Control) sub-layers of IEEE 802.11x, including IEEE 802.11e, defines Connection-based and CF (Contention Free)-based service functions in common. In this paper, a New-CF method is proposed. In the proposed method, conventional Round Robin method, which is used as a polling method by IEEE 802.11x PCF (Point Coordination Function) or IEE 802.11e HCCA, is modified to give weights to channels with heavier traffic load and to provide those weighted channels with more services. Based on NS-2 simulations, it is verified the proposed method shows better throughput in general, particularly under unbalanced traffic load conditions.

Optimization of Operational Conditions of Existing BNR Process with Various C/N Ratio using Simulation Method (시뮬레이션 기법을 이용한 기존 BNR공정의 C/N비 변화에 따른 운전조건 최적화)

  • Rho, Hae-Yeon;Gil, Kyung-Ik
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.3
    • /
    • pp.367-370
    • /
    • 2007
  • Numerous sets of simulation were conducted in order to find out the optimum operational conditions of the existing BNR process using GPS-X program. The model of ASM3 and modified Bio-P module were applied for simulations. From the result of this study, effluent quality was closely related with the step feeding rate and influent C/N ratio. The effluent TN concentration seemed to be significantly affected by step feeding rate at the low C/N condition. But at the high C/N condition, the effluent concentration of TP rather than that of TN was affected by the control of step feeding rate.

Optimization of Operation Conditions for Improving the Nitrogen Removal Efficiency in Wastewater Treatment Plant (질소제거효율 향상을 위한 하수처리장 최적 운전조건 도출 연구)

  • Choi, Eun-Hee;Bram, Klapwijk;Mathijs, Oosterhuis
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.1
    • /
    • pp.25-31
    • /
    • 2010
  • 네덜란드 브리젠빈 하폐수처리장 최종방류수의 $NH_4$-N 및 TN(Total Nitrogen)농도를 방류수 수질기준인 각각 4 mg/L와 10 mg/L에 맞추기 위한 최적의 운전조건을 도출하기 위해 다양한 제어시스템이 시뮬레이션 되었다. 본 연구에 사용된 모델은 IWA(International Water Association) 활성슬러지 모델 No.1 (ASM No.1)이었고, GPS-X가 시뮬레이터로 사용되었다. 모델링을 위한 매개변수 민감도 분석결과 ASM No.1의 총 19개 매개변수 중 8개 변수 ($Y_H$, ksh, koh, $b_H$, ${\mu}_a$, $k_{NA}$, kh, ka)가 방류수 수질에 영향을 미치는 것으로 조사되었고 이들 매개변수에 대해 보정을 수행하여 사용하였다. SRT, 호기/무산소기간, 외부탄소원 주입시간 변화에 따른 방류수질 변화를 시뮬레이션하였는데, 호기/무산소 11h/1h인 조건에서 SRT가 20일에서 25일로 증가되면 $NH_4$-N가 5.0 mg/L에서 2.9 mg/L로 감소되었고 호기/무산소 2h/1h의 조건에서는 SRT증가에 따라 $NH_4$-N은 큰 감소를 보이지만, 바이패스되는 유입수량의 감소로 탈질율이 낮아 방류수 TN이 11.1~11.5 mg/L로 예측되는 결과가 도출되었다. 탈질율을 높이기 위한 아세트산 주입은 동일한 양의 아세트산을 무산소 전기간 (1h)동안 균일 주입하는 것 보다는 무산소 초기 15분내에 주입하는 것이 효율적인 것으로 나타났다.

Analysis of Proper Linked Treatment Load Using GPS-X Simulation (GPS-X 시뮬레이션을 이용한 적정 연계처리부하량 분석)

  • Kim, Sungji;Lee, Jiwon;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.21 no.3
    • /
    • pp.244-250
    • /
    • 2019
  • Due to the industrial development and population growth, it has recently been shown that there are many problems caused by the rinked treatment water in local goverments and sewage treatment plants. The rinked treatment water has a characteristic of low flow rate and high concentration unlike general sewage. These characteristics increase sewage treatment difficulty and sewage treatment fee of sewage treatment facilities. Among the many influencing factors that increase sewage treatment unit cost, 'linked treatment load/design inflow load (%)' was derived as the most correlated factor. Through the selection and modeling of sewage treatment plants, the excess scope of design discharge water quality was investigated under the conditions of temperature and the conditions of 'linked treatment load/design inflow load (%)' taking into account the effects of the four seasons. The study found that for TN, 'linked treatment load/design inflow load (%)' was 19.7%, 22.6%, 25.1%and 27.7%, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$. In case of TP, 'rinked treatment load/design inflow load (%)' was 10.7%, 12.2%, 15.6% and 17.5% at $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$, and $25^{\circ}C$, respectively, under conditions of $5^{\circ}C$, $10^{\circ}C$, $20^{\circ}C$ and $25^{\circ}C$.

The Study of the Need to Remove Soluble nitrogen ($NH_3-N$) Generated from Anaerobic digestor Retrofitted in Municipal Wastewater Treatment Plants (하수처리장 에너지자립화사업에서 혐기성소화공정으로부터 용출되는 용존성질소($NH_3-N$)의 처리 필요성 연구)

  • Ahn, Seyoung
    • Journal of the Korea Organic Resources Recycling Association
    • /
    • v.22 no.3
    • /
    • pp.68-75
    • /
    • 2014
  • Soluble nitrogen produced from anaerobic digestor is able to have a strong influence on the effluent water quality of municipal wastewater treatment plants during a winter season in particular. The modeling results using the GPS-X simulation software shows that the soluble nitrogen concentration generated from the anaerobic digestor is 214.1 mg/L in the return flow and 6.2 mg/L in the inflow of the primary settler higher than those in nonexistence of the anaerobic digestor, respectively. In the case of using a separation process (flotation thickener) in order to treat the return flow from the sludge treatment system, the soluble nitrogen concentration in the effluent from the separation process and in the inflow of the primary setter could be 6.0 mg/L higher and 0.7 mg/L lower than those of nonexistence of the process, respectively. The modeling results propose the need of the equipments to be able to remove the soluble nitrogen ($NH_3-N$) produced from the digestor in the improvement projects of anaerobic digestor in municipal wastewater treatment plants.