• Title/Summary/Keyword: GLCM Algorithm

Search Result 25, Processing Time 0.025 seconds

GLCM Algorithm Image Analysis of Nonalcoholic Fatty Liver and Focal Fat Sparing Zone in the Ultrasonography (초음파검사에서 비알콜성 지방간과 국소지방회피영역에 대한 GLCM Algorithm 영상분석)

  • Cho, Jin-Young;Ye, Soo-Young
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.205-211
    • /
    • 2017
  • There is a need for aggressive diagnosis and treatment in middle-aged and high-risk individuals who are more likely to progress from nonalcoholic fatty liver to hepatitis. In this study, nonalcoholic fatty liver was divided into severe, moderate, and severe, and classified by quantitative method using computer analysis of GLCM algorithm. The purpose of this study was to evaluate the characteristics of ultrasound images in the local fat avoidance region. Normal, mild, moderate, severe fatty liver, and focal fat sparing area, 80 cases, respectively. Among the parameters of the GLCM algorithm, the values of the Autocorrelation, Square of the deviation, Sum of averages and Sum of variances with high recognition rate of the liver ultrasound image were calculated. The average recognition rate of the GLCM algorithm was 97.5%. The result of local fat avoidance image analysis showed the most similar value to the normal parenchyma. Ultrasonography can be easily accessed by primary screening, but there may be differences in the accuracy of the test method or the correspondence of results depending on proficiency. GLCM algorithm was applied to quantitatively classify the degree of fatty liver. Local fat avoidance region was similar to normal parenchyma, so it could be predicted to be homogeneous liver parenchyma without fat deposition. We believe that GLCM computer image analysis will provide important information for differentiating not only fatty liver but also other lesions.

Retrospective Analysis of Cytopathology using Gray Level Co-occurrence Matrix Algorithm for Thyroid Malignant Nodules in the Ultrasound Imaging (갑상샘 악성결절의 초음파영상에서 GLCM 알고리즘을 이용한 세포병리 진단의 후향적 분석)

  • Kim, Yeong-Ju;Lee, Jin-Soo;Kang, Se-Sik;Kim, Changsoo
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.237-243
    • /
    • 2017
  • This study evaluated the applicability of computer-aided diagnosis by retrospective analysis of GLCM algorithm based on cytopathological diagnosis of normal and malignant nodules in thyroid ultrasound images. In the experiment, the recognition rate and ROC curve of thyroid malignant nodule were analyzed using 6 parameters of GLCM algorithm. Experimental results showed 97% energy, 93% contrast, 92% correlation, 92% homogeneity, 100% entropy and 100% variance. Statistical analysis showed that the area under the curve of each parameter was more than 0.947 (p = 0.001) in the ROC curve, which was significant in the recognition of thyroid malignant nodules. In the GLCM, the cut-off value of each parameter can be used to predict the disease through analysis of quantitative computer-aided diagnosis.

Non-alcoholic Fatty Liver Disease Classification using Gray Level Co-Ocurrence Matrix and Artificial Neural Network on Non-alcoholic Fatty Liver Ultrasound Images (비알콜성 지방간 초음파 영상에 GLCM과 인공신경망을 적용한 비알콜성 지방간 질환 분류)

  • Ji-Yul Kim;Soo-Young Ye
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.5
    • /
    • pp.735-742
    • /
    • 2023
  • Non-alcoholic fatty liver disease is an independent risk factor for the development of cardiovascular disease, diabetes, hypertension, and kidney disease, and the clinical importance of non-alcoholic fatty liver disease has recently been increasing. In this study, we aim to extract feature values by applying GLCM, a texture analysis method, to ultrasound images of patients with non-alcoholic fatty liver disease. By applying an artificial neural network model using extracted feature values, we would like to classify the degree of fat deposition in non-alcoholic fatty liver into normal liver, mild fatty liver, moderate fatty liver, and severe fatty liver. As a result of applying the GLCM algorithm, the parameters Autocorrelation, Sum of squares, Sum average, and sum variance showed a tendency for the average value of the feature values to increase as it progressed from mild fatty liver to moderate fatty liver to severe fatty liver. The four parameters of Autocorrelation, Sum of squares, Sum average, and sum variance extracted by applying the GLCM algorithm to ultrasound images of non-alcoholic fatty liver disease were applied as inputs to the artificial neural network model. The classification accuracy was evaluated by applying the GLCM algorithm to the ultrasound images of non-alcoholic fatty liver disease and applying the extracted images to an artificial neural network, showing a high accuracy of 92.5%. Through these results, we would like to present the results of this study as basic data when conducting a texture analysis GLCM study on ultrasound images of patients with non-alcoholic fatty liver disease.

A Performance Improvement of GLCM Based on Nonuniform Quantization Method (비균일 양자화 기법에 기반을 둔 GLCM의 성능개선)

  • Cho, Yong-Hyun
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.25 no.2
    • /
    • pp.133-138
    • /
    • 2015
  • This paper presents a performance improvement of gray level co-occurrence matrix(GLCM) based on the nonuniform quantization, which is generally used to analyze the texture of images. The nonuniform quantization is given by Lloyd algorithm of recursive technique by minimizing the mean square error. The nonlinear intensity levels by performing nonuniformly the quantization of image have been used to decrease the dimension of GLCM, that is applied to reduce the computation loads as a results of generating the GLCM and calculating the texture parameters by using GLCM. The proposed method has been applied to 30 images of $120{\times}120$ pixels with 256-gray level for analyzing the texture by calculating the 6 parameters, such as angular second moment, contrast, variance, entropy, correlation, inverse difference moment. The experimental results show that the proposed method has a superior computation time and memory to the conventional 256-level GLCM method without performing the quantization. Especially, 16-gray level by using the nonuniform quantization has the superior performance for analyzing textures to another levels of 48, 32, 12, and 8 levels.

Ultrasonic Image Analysis Using GLCM in Diffuse Thyroid Disease (미만성 갑상샘 질환에서 GLCM을 이용한 초음파 영상 분석)

  • Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.4
    • /
    • pp.473-479
    • /
    • 2021
  • The diagnostic criteria for diffuse thyroid disease are ambiguous and there are many errors due to the subjective diagnosis of experts. Also, studies on ultrasound imaging of thyroid nodules have been actively conducted, but studies on diffuse thyroid disease are insufficient. In this study, features were extracted by applying the GLCM algorithm to ultrasound images of normal and diffuse thyroid disease, and quantitative analysis was performed using the extracted feature values. Using the GLCM algorithm for thyroid ultrasound images of patients diagnosed at W hospital, 199 normal cases, 132 mild cases, and 99 moderate cases, a region of interest (50×50 pixel) was set for a total of 430 images, and Autocorrelation, Sum of squares, sum average, sum variance, cluster prominence, and energy were analyzed using six parameters. As a result, in autocorrelation, sum of squares, sum average, and sum variance four parameters, Normal, Mild, and Moderate were distinguished with a high recognition rate of over 90%. This study is valuable as a criterion for classifying the severity of diffuse thyroid disease in ultrasound images using the GLCM algorithm. By applying these parameters, it is expected that errors due to visual reading can be reduced in the diagnosis of thyroid disease and can be utilized as a secondary means of diagnosing diffuse thyroid disease.

Implementation of GLCM/GLDV-based Texture Algorithm and Its Application to High Resolution Imagery Analysis (GLCM/GLDV 기반 Texture 알고리즘 구현과 고 해상도 영상분석 적용)

  • Lee Kiwon;Jeon So-Hee;Kwon Byung-Doo
    • Korean Journal of Remote Sensing
    • /
    • v.21 no.2
    • /
    • pp.121-133
    • /
    • 2005
  • Texture imaging, which means texture image creation by co-occurrence relation, has been known as one of the useful image analysis methodologies. For this purpose, most commercial remote sensing software provides texture analysis function named GLCM (Grey Level Co-occurrence Matrix). In this study, texture-imaging program based on GLCM algorithm is newly implemented. As well, texture imaging modules for GLDV (Grey Level Difference Vector) are contained in this program. As for GLCM/GLDV Texture imaging parameters, it composed of six types of second order texture functions such as Homogeneity, Dissimilarity, Energy, Entropy, Angular Second Moment, and Contrast. As for co-occurrence directionality in GLCM/GLDV, two direction modes such as Omni-mode and Circular mode newly implemented in this program are provided with basic eight-direction mode. Omni-mode is to compute all direction to avoid directionality complexity in the practical level, and circular direction is to compute texture parameters by circular direction surrounding a target pixel in a kernel. At the second phase of this study, some case studies with artificial image and actual satellite imagery are carried out to analyze texture images in different parameters and modes by correlation matrix analysis. It is concluded that selection of texture parameters and modes is the critical issues in an application based on texture image fusion.

EVALUATION OF SPEED AND ACCURACY FOR COMPARISON OF TEXTURE CLASSIFICATION IMPLEMENTATION ON EMBEDDED PLATFORM

  • Tou, Jing Yi;Khoo, Kenny Kuan Yew;Tay, Yong Haur;Lau, Phooi Yee
    • Proceedings of the Korean Society of Broadcast Engineers Conference
    • /
    • 2009.01a
    • /
    • pp.89-93
    • /
    • 2009
  • Embedded systems are becoming more popular as many embedded platforms have become more affordable. It offers a compact solution for many different problems including computer vision applications. Texture classification can be used to solve various problems, and implementing it in embedded platforms will help in deploying these applications into the market. This paper proposes to deploy the texture classification algorithms onto the embedded computer vision (ECV) platform. Two algorithms are compared; grey level co-occurrence matrices (GLCM) and Gabor filters. Experimental results show that raw GLCM on MATLAB could achieves 50ms, being the fastest algorithm on the PC platform. Classification speed achieved on PC and ECV platform, in C, is 43ms and 3708ms respectively. Raw GLCM could achieve only 90.86% accuracy compared to the combination feature (GLCM and Gabor filters) at 91.06% accuracy. Overall, evaluating all results in terms of classification speed and accuracy, raw GLCM is more suitable to be implemented onto the ECV platform.

  • PDF

Implementation for Texture Imaging Algorithm based on GLCM/GLDV and Use Case Experiments with High Resolution Imagery

  • Jeon So Hee;Lee Kiwon;Kwon Byung-Doo
    • Proceedings of the KSRS Conference
    • /
    • 2004.10a
    • /
    • pp.626-629
    • /
    • 2004
  • Texture imaging, which means texture image creation by co-occurrence relation, has been known as one of useful image analysis methodologies. For this purpose, most commercial remote sensing software provides texture analysis function named GLCM (Grey Level Co-occurrence Matrix). In this study, texture-imaging program for GLCM algorithm is newly implemented in the MS Visual IDE environment. While, additional texture imaging modules based on GLDV (Grey Level Difference Vector) are contained in this program. As for GLCM/GLDV texture variables, it composed of six types of second order texture function in the several quantization levels of 2(binary image), 8, and 16: Homogeneity, Dissimilarity, Energy, Entropy, Angular Second Moment, and Contrast. As for co-occurrence directionality, four directions are provided as $E-W(0^{\circ}),\;N-E(45^{\circ}),\;S-W(135^{\circ}),\;and\;N-S(90^{\circ}),$ and W-E direction is also considered in the negative direction of E- W direction. While, two direction modes are provided in this program: Omni-mode and Circular mode. Omni-mode is to compute all direction to avoid directionality problem, and circular direction is to compute texture variables by circular direction surrounding target pixel. At the second phase of this study, some examples with artificial image and actual satellite imagery are carried out to demonstrate effectiveness of texture imaging or to help texture image interpretation. As the reference, most previous studies related to texture image analysis have been used for the classification purpose, but this study aims at the creation and general uses of texture image for urban remote sensing.

  • PDF

Ultrasonic image assessment of the degree of pancreatic fat deposition (췌장 지방 침착 정도에 따른 초음파 영상 평가)

  • Park, Hye-in;Park, Seung-hun;Beak, Yun-seung;Lee, Seon-bin;Lee, Eun-sol;Heo, Yeong-dae;Cho, Jin-young;Ko, Seong-Jin
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.490-492
    • /
    • 2016
  • Pancreatic ultrasound imaging is used to diagnose pancreatic hyperplasia, pancreatic steatosis, pancreatic cancer and the like. If the diagnosis of pancreatic steatosis is pancreatic parenchyma echo shades splashes spleen than in the pancreas ultrasound it determines that the fat is deposited. And research on ultrasound imaging of pancreatic cancer but is actively conducted research studies on pancreatic steatosis is insufficient In addition, pancreatic steatosis is often an error in accordance with the diagnostic criteria are vague and subjective diagnosis of the artisan. This study was a quantitative analysis using the feature value extracting a feature of an image extracted by applying a parameter to the algorithm GLCM image of the normal and pancreatic fat. Setting a region of interest ($5{\times}5pixel$) in the mild 89 case, moderate 89 case, severe 89 case, total image 267 case using GLCM algorithm, and using the Autocorrelation, Sum average, Sum of squares, Sum varience 4 kinds parameter in each image It was analyzed.

  • PDF

Target Detection Algorithm of Sidescan Sonar imagery based on GLCM(Gray Level Co-occurrence Matrix) (GLCM을 기반으로 한 사이드 스캔 소나 영상의 목표물 탐색 알고리즘)

  • 조영건;박요섭;김학일
    • Proceedings of the Korean Society of Coastal and Ocean Engineers Conference
    • /
    • 2002.08a
    • /
    • pp.308-315
    • /
    • 2002
  • 해양구조물 설치(Offshore Engineering)에 대한 수요가 급증함에 따라 보다 정확한 설계와 시공을 위한 해저지형 및 지질환경에 대한 탐사(Geophysical Survey)수요가 급격히 증가하고 있다. 전자기파의 감쇄가 심한 해수로 덮여 있는 해저에 대한원격탐사 매체로는 SONAR(SOund Navigation And Ranging)시스템이 일반적으로 이용되고 있다. (중략)

  • PDF