• 제목/요약/키워드: GFRP-concrete bond

검색결과 69건 처리시간 0.026초

콘크리트 고온 가열 이후 CFRP와 GFRP의 부착강도 특성 (Post-Thermal Exposure Bond Strength Properties of CFRP and GFRP in Concrete)

  • 김주성;정수미;김영진;박선규
    • 한국건축시공학회지
    • /
    • 제23권5호
    • /
    • pp.509-517
    • /
    • 2023
  • 철근 부식을 해결하기 위해 FRP에 관한 연구가 증가하고 있다. CFRP는 경량화로 시공성이 용이하며, 내식성 및 내화학성이 뛰어나 이형철근 대체제로 지목되고 있다. 하지만 CFRP는 섬유와 레진을 압착하여 만들어져 열에 취약한 단점이 존재한다. 이러한 CFRP에 관한 연구는 미비한 실정이며, 본 연구에서는 고온 가열 이후 CFRP와 GFRP의 부착강도에 관한 연구를 실시하였다. 그 결과 규사코팅 CFRP와 리브형 CFRP, GFRP 모두 비슷한 부착강도 발현을 보였다.

Flexural behavior and a modified prediction of deflection of concrete beam reinforced with a ribbed GFRP bars

  • Ju, Minkwan;Park, Cheolwoo;Kim, Yongjae
    • Computers and Concrete
    • /
    • 제19권6호
    • /
    • pp.631-639
    • /
    • 2017
  • This study experimentally investigated the flexural capacity of a concrete beam reinforced with a newly developed GFRP bar that overcomes the lower modulus of elasticity and bond strength compared to a steel bar. The GFRP bar was fabricated by thermosetting a braided pultrusion process to form the outer fiber ribs. The mechanical properties of the modulus of elasticity and bond strength were enhanced compared with those of commercial GFRP bars. In the four-point bending test results, all specimens failed according to the intended failure mode due to flexural design in compliance with ACI 440.1R-15. The effects of the reinforcement ratio and concrete compressive strength were investigated. Equations from the code were used to predict the deflection, and they overestimated the deflection compared with the experimental results. A modified model using two coefficients was developed to provide much better predictive ability, even when the effective moment of inertia was less than the theoretical $I_{cr}$. The deformability of the test beams satisfied the specified value of 4.0 in compliance with CSA S6-10. A modified effective moment of inertia with two correction factors was proposed and it could provide much better predictability in prediction even at the effective moment of inertia less than that of theoretical cracked moment of inertia.

화학적 환경에 노출된 콘크리트 보강용 FRP 보강근의 부착 성능 (Bond Performance of FRP Reinforcing Bar for Concrete Structures after Chemical Environmental Exposure)

  • 박찬기;원종필
    • 한국농공학회논문집
    • /
    • 제46권3호
    • /
    • pp.73-81
    • /
    • 2004
  • FRP reinforcing bars(rebars) are produced through a variety of manufacturing process includes pultrusion, and filament winding and braiding etc. Each manufacturing method produces a different surface condition of FRP rebar. The surface properties of FRP rebar is an important property for mechanical bond with concrete. Current methods of providing surface deformation to FRP rebars include helical wrapping, surfaces and coating and rib molding. The problem with the helical wrapping method is that it can not provide enough surface deformation for good bond and it can be easily sheard off from the FRP rebars. Sand coating and rib molding provide surface deformation only to the outer FRP skins. Therefore, FRP rebar has about 60% of bond strength of steel rebar. The main objective was to evaluate the bond properties of FRP rebar after environmental exposure. Five types of FRP rebar includes CFRP ISO, GFRP Aslan, AFRP Technora CFRP(Korea), and GFRP(Korea) rebars performed direct bond tests. Also, FRP rebar bond specimens were subjected to exposure conditions including alkaline solution, acid solution, salt solution and deionized water etc. According to bond test results, CFRP(Korea) and CFRP(Korea) rebars were found to have better bond strength with concrete than previous FRP rebars. Also, FRP(Korea) rebar had more than about 70% in bond strength of steel rebar.

Analysis of rectangular hybrid steel-GFRP reinforced concrete beam columns

  • El-Heloua, Rafic G.;Aboutaha, Riyad S.
    • Computers and Concrete
    • /
    • 제16권2호
    • /
    • pp.245-260
    • /
    • 2015
  • In this study, nominal moment-axial load interaction diagrams, moment-curvature relationships, and ductility of rectangular hybrid beam-column concrete sections are analyzed using the modified Hognestad concrete model. The hybrid columns are primarily reinforced with steel bars with additional Glass Fiber Reinforced Polymer (GFRP) control bars. Parameters investigated include amount, pattern, location, and material properties of concrete, steel, and GFRP. The study was implemented using a user defined comprehensive $MATLAB^{(R)}$ simulation model to find an efficient hybrid section design maximizing strength and ductility. Generating lower bond stresses than steel bars at the concrete interface, auxiliary GFRP bars minimize damage in the concrete core of beam-column sections. Their usage prevents excessive yielding of the core longitudinal bars during frequent moderate cyclic deformations, which leads to significant damage in the foundations of bridges or beam-column spliced sections where repair is difficult and expensive. Analytical results from this study shows that hybrid steel-GFRP composite concrete sections where GFRP is used as auxiliary bars show adequate ductility with a significant increase in strength. Results also compare different design parameters reaching a number of design recommendations for the proposed hybrid section.

Bond behavior between steel and Glass Fiber Reinforced Polymer (GFRP) bars and ultra high performance concrete reinforced by Multi-Walled Carbon Nanotube (MWCNT)

  • Ahangarnazhad, Bita Hosseinian;Pourbaba, Masoud;Afkar, Amir
    • Steel and Composite Structures
    • /
    • 제35권4호
    • /
    • pp.463-474
    • /
    • 2020
  • In this paper, the influence of adding multi-walled carbon nanotube (MWCNT) on the pull behavior of steel and GFRP bars in ultra-high-performance concrete (UHPC) was examined experimentally and numerically. For numerical analysis, 3D nonlinear finite element modeling (FEM) with the help of ABAQUS software was used. Mechanical properties of the specimens, including Young's modulus, tensile strength and compressive strength, were extracted from the experimental results of the tests performed on standard cube specimens and for different values of weight percent of MWCNTs. In order to consider more realistic assumptions, the bond between concrete and bar was simulated using adhesive surfaces and Cohesive Zone Model (CZM), whose parameters were obtained by calibrating the results of the finite element model with the experimental results of pullout tests. The accuracy of the results of the finite element model was proved with conducting the pullout experimental test which showed high accuracy of the proposed model. Then, the effect of different parameters such as the material of bar, the diameter of the bar, as well as the weight percent of MWCNT on the bond behavior of bar and UHPC were studied. The results suggest that modifying UHPC with MWCNT improves bond strength between concrete and bar. In MWCNT per 0.01 and 0.3 wt% of MWCNT, the maximum pullout strength of steel bar with a diameter of 16 mm increased by 52.5% and 58.7% compared to the control specimen (UHPC without nanoparticle). Also, this increase in GFRP bars with a diameter of 16 mm was 34.3% and 45%.

GFRP 보강근의 외피형상을 고려한 부착 해석모델 제안 (An Analytical Model Proposal Considering Different Surface Type of Bond Behavior between GFRP Rebar and Concrete)

  • 박지선;송태협;이정윤
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제23권3호
    • /
    • pp.150-159
    • /
    • 2019
  • GFRP 보강근과 콘크리트의 부착성능은 접착력, 부착력 및 지압력으로 발휘되며 보강근의 표면처리 방식이나 외피형상에 따라 발휘되는 부착저항력의 종류와 크기는 다르다. GFRP 부착 해석모델에 대한 선행연구를 살펴보면 철근의 부착 해석모델을 일부 수정하여 발전시키거나 수치해석을 통한 매개변수의 수가 많은 복잡한 해석식을 제안하였다. 전자의 경우에는 규격화된 마디형상을 갖는 철근과 달리 구성재료, 배합방법, 제조방법에 따라 다양한 외피형상을 가지는 GFRP 보강근의 특성을 포괄적으로 제안하는 데는 제약이 있으며 후자의 경우에는 수치해석으로 인한 수학적 관계식으로 GFRP 보강근의 부착거동과의 역학적인 관계를 고려하기에는 어려움이 있다. 따라서 이 연구에서는 GFRP 보강근의 콘크리트와의 외피형상에 따라 달라지는 부착메커니즘을 반영한 부착 해석모델을 제안하고자 하였다. 제안한 부착 해석모델에 대한 적합성 검증을 위하여 타 연구자가 수행한 실험값과 비교하였으며 기존의 부착 해석모델인 BPE 부착 해석모델과 CMR 부착 해석모델과의 비교연구도 수행하였다. 비교결과 이 연구에서 제안한 부착 해석모델이 실제 거동에 가장 근사하게 평가하였다.

유리섬유쉬트로 전단보강된 저강도 RC보의 전단강도 (Shear Strength of Low-Strength RC Beams Strengthened with Glass Fiber Sheets)

  • 유영찬;최기선;김도겸;류금성;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2005년도 봄학술 발표회 논문집(I)
    • /
    • pp.283-286
    • /
    • 2005
  • The effectiveness of shear strengthening with glass fiber sheets on normal or low strength RC beams have been investigated experimentally. A design compressive strength of concrete of 13.5MPa has been planned considering the degradation state of the existing structure to be strengthened in this study. Also, concrete surface reinforcing agent was applied to increase bond capacity between concrete and GFRP sheets in case of low strength RC beams. Comparing the test results of low and normal strength beams strengthened with GFRP sheets indicated that total shear capacity of beams was decreased with concrete strength decreased, but the shear strengthening capacity of GFRP sheets are hardly affected by concrete strength. In addition, shear strengthening effects of RC beams strengthened with GFRP sheets can be estimated by $\rho_w{\cdot}f_w$ based on the maximum effective strain of FRP sheet proposed by ACI 440.2R recommendation.

  • PDF

GFRP 보강근의 단면 위치에 따른 부착특성 (Bond Characteristics of Glass Fiber Reinforced Polymer Rebar according to the Bar Location)

  • 박지선;박영환;유영준;황금식;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.197-200
    • /
    • 2006
  • The bond characteristics of three different types of glass fiber reinforced polymer(GFRP) reinforcing bars with different surface deformations were studied experimentally. Each specimen consisted of a concrete prism, 150 by 150 mm on each edge, with the longer axis in the vertical direction. Two rebars were embedded in each specimen, perpendicular to the longer axis and parallel to and equidistant from the sides of the prism. In vertical direction, one rebar was located at 75 mm from the bottom of the prism, and the other 225 mm from the bottom. All testing procedures including specimens preparation, set-up of test equipments and measuring devices were made according to the recommendations of CSA Standard S806-02.It was found that the bottom reinforcements showed higher bond stress than that of the top rebars.

  • PDF

쪼갬파괴가 발생된 GFRP 보강근을 사용한 이음길이 산정식 (Equation of the Development Length for the Pullout tests with GFRP Reinforcement having Splitting Failure)

  • 하상수;최동욱
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.859-862
    • /
    • 2008
  • 본 연구는 GFRP 보강근의 정착길이 산정식을 제안하는 것이다. 정착길이 산정식을 제안하기 위해 인발실험을 실시하였다. 실험변수는 묻힘길이, 피복두께, 보강근 직경, 보강근 종류이다. 묻힘길이는 15d$_b$, 30d$_b$, 45d$_b$로 하고, 순 피복두께는 0.5d$_b$, 1.0d$_b$, 1.5d$_b$, 및 2.0d$_b$로 계획하였다. 사용된 보강근은 모두 3종류(국내 2종, 국외 1종)이고 보강근 크기는 D10, D13, D16이다. 실험은 겹침이음된 GFRP 보강근 양 단부를 동시에 인발하여 최종파괴에 도달될 때까지 GFRP 보강근에 하중을 가력하였다. 인발실험을 통해 얻은 결과를 토대로 각 변수에 따른 GFRP 보강근의 부착특성 및 평균부착응력을 산정하였으며, 실험체중 쪼갬파괴된 실험체만을 선택하여 회귀분석을 통해 정착길이 산정식은 제안하였고 ACI 440.1R-06에 제안하고 있는 식과 비교하였다. 본 연구를 통해 제안된 회귀분석에 의한 제안식을 근거로 겹침이음된 GFRP 보강근을 이용한 휨 설계가 가능할 것으로 판단된다.

  • PDF

GFRP 보강근으로 보강된 바닥판의 보강비에 따른 거동 실험 (Behavior of GFRP reinforced decks with various reinforcement ratio)

  • 유영준;박지선;박영환;김형열;김긍환
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 춘계 학술발표회 제20권1호
    • /
    • pp.49-52
    • /
    • 2008
  • 유리섬유를 사용한 섬유강화복합체(Glass Fiber Reinforced Polymer, GFRP) 보강근의 인장강도 및 부착성능 등은 철근과 다르기 때문에 GFRP 보강근을 콘크리트 구조물에 적용하기 위해서는 GFRP 보강근으로 보강된 콘크리트 부재의 거동에 관한 연구가 선행되어야 한다. GFRP는 높은 비강도, 경량성, 비부식성 등의 장점을 가지고 있으나 탄성계수가 철근보다 작아 상대적으로 큰 처짐이 발생하는 단점이 있다. 교량 바닥판은 아칭효과 등에 의해 휨성능이 증가하므로 FRP 보강근을 우선 적용할 수 있는 대상 중 하나이다. 본 논문은 국내에서 개발된 철근 대체재용 GFRP 보강근의 콘크리트 구조물로의 적용 가능성을 관찰하기 위한 실험연구에 관한 것으로 폭과 길이가 3,000 mm, 4,000 mm이고 두께가 240 mm인 실제 크기의 콘크리트 바닥판을 제작하여 GFRP 보강근의 보강비에 따른 거동을 관찰하였다. 정적실험을 수행하였으며 DB-24 하중등급의 축하중을 모사한 재하면적을 가진 직사각형 강재로 바닥판이 파괴될 때까지 집중하중을 가하였다. 철근 보강 바닥판과 GFRP 보강 바닥판의 거동차이를 최대성능 및 처짐 거동 등에 대해 비교 검토하였다.

  • PDF