• 제목/요약/키워드: GER-3700

검색결과 4건 처리시간 0.025초

VICARIOUS GROUND CALIBRATION OF AIRBORNE MULTISPECTRAL SCANNER (AMS) DATA BASED ON FIELD CAMPAIGN

  • Lee, Kwang-Jae;Kim, Yong-Seung;Han, Jong-Gyu
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.184-187
    • /
    • 2006
  • The radiometric correction is prerequisite to derive both land and ocean surface properties from optical remote sensing data. Radiometric calibration of remotely sensed data has traditionally been accomplished by means of vicarious ground calibration techniques. The purpose of this study is to calibrate the radiometric characteristic of Airborne Multispectral Scanner (AMS) by field campaign. In order to calibrate the AMS data, four different spectral tarps which are 3.5%, 23%, 35%, and 53% were validated by GER-3700 that is the surface reflectance measurement equipment and were utilized. After validation of the spectral tarps, each reflectance from the spectral tarps was compared with Digital Number (DN) value of AMS. There was very high correlation between tarp reflectance and DN value of AMS so that radiometric calibration of AMS data has been accomplished by those results. The calibrated AMS data were validated with in-situ measured reflectance data from artificial and natural target. Also QuickBird image data were used for verifying the results of AMS radiometric calibration. This presentation discusses the results of the above tests.

  • PDF

다목적실용위성2호 Panchromatic sensor의 절대복사보정 초기실험

  • 이선구;권은한;김용승
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 춘계학술대회 논문집
    • /
    • pp.311-314
    • /
    • 2007
  • 다목적실용위성2호 영상자료의 절대복사 보정계수 산출을 위하여 위성 통과시각에 맞추어 2007년 2월 3일 현장실험을 수행하였다. 측정기기로는 Spectroradiometer GER-3700을 사용하였으며, 관측 Target은 아스팔트, 흙, 콘크리트, 잔디, Tarp 53%로 각 Target의 복사량을 측정한 후 지표면 반사도로 변환하였다. 현장에서 관측된 지표면 반사도를 복사전달모델 MODTRAN의 압력 자료로 사용하여 대기권 밖에서 관측될 복사량을 모의할 수 있었다. 마지막으로, 모의된 각 Target의 복사량과 실제 위성 센서가 관측한 DN(Digital Number) 값의 관계식을 이용하여 절대복사 보정계수를 산출하였다. 본 연구 결과는 센서의 반옹도가 반영되지 않은 임시 결과이며, 추후 보다 많은 현장실험 결과를 추가하여 정확한 절대복사 보정계수를 산출할 계획이다.

  • PDF

Use of Terrestrial Hyperspectral Sensors for Analyzing Spectral Reflectance Characteristics of Concrete

  • Lee, Jin Duk;Lee, Sung Soon;Sim, Jung Bo
    • 한국측량학회지
    • /
    • 제32권3호
    • /
    • pp.185-190
    • /
    • 2014
  • The purpose of this research is to extract spectral reflectance characteristics of concretes through basic experiment on concrete specimens and site experiment on actual concrete structures using a field portable spectrometer and a VNIR hyperspectral sensor. A spectrometer (GER-3700) and a VNIR hyperspectral camera (AisaEagle VNIR Hyperspectral Camera) were utilized for extracting spectral characteristics of concrete specimens. Concretes normally show similar patterns that have correlation above 80%, while the high-strengthened concretes display very different results from the normal-strength concretes. We also made a certain conclusion in the laboratory experiment on concrete specimens that both the spectrometer and the VNIR camera vary in spectral reflectance depending on concrete strengths.

소나무재선충병 감염목의 분광반사 특성 구명 (Investigation Into Reflectance Characteristics of Trees Infected by Pine Wilt Disease)

  • 김소라;이우균;남기준;송용호;유항남;김문일;이종열;이승호
    • 한국산림과학회지
    • /
    • 제102권4호
    • /
    • pp.499-505
    • /
    • 2013
  • 소나무재선충병(Bursaphelenchus xylophilus)은 한국, 일본, 그리고 중국과 같은 동아시아의 소나무류 산림에 심각한 피해를 유발시킨다. 재선충병에 의한 병해는 그 치료방법이 훈증, 소각외에는 거의 없기 때문에 감염목을 조기 탐지하여 그 피해가 주변 임목 및 임분에 확산되지 않도록 하는 것이 최선책이라 할 수 있다. 본 연구에서는 소나무재선충병 감염목과 비감염목의 분광반사율을 주기적으로 측정하여 감염목의 분광반사 특성을 구명하였다. 이를 위하여, 6월에서 10월까지 GER3700 spectroradiometer를 이용하여 감염목과 비감염목의 400 nm~2,500 nm 파장대의 분광반사값을 측정하였다. 측정된 값의 noise를 보정하기 위하여 cubic spline 보간법을 사용하였다. 그 결과, 대부분의 감염목들은 재선충 주입 후 2개월 이내에 적색(600 nm~700 nm) 그리고 중적외선(1,400 nm~1,500 nm) 파장대에서 분광반사값의 변화를 보였으나, 비감염목들의 분광반사값은 어느 파장대에서도 특별한 변화가 나타나지 않았다. 시기별로 감염목과 비감염목의 분광반사값 변화를 통계적으로 비교해 본 결과, 소나무재선충 주입 2달 후 적색 파장대역과 중적외선 파장대역에서 가장 빠르게 통계적으로 유의한 차이를 보였으나(p<0.05), 근적외선 파장대역에서는 통계적으로 유의한 차이가 나타나지 않았다(p>0.05). 따라서 적색과 중적외선 파장대역에서의 분광반사율 변화를 통해 소나무재선충병 감염목의 조기 탐지가 가능한 것으로 판단되었다.