• Title/Summary/Keyword: GEANT4 simulation

Search Result 132, Processing Time 0.023 seconds

Analysis of Dose Distribution According to the Initial Electron Beam of the Linear Accelerator: A Monte Carlo Study

  • Park, Hyojun;Choi, Hyun Joon;Kim, Jung-In;Min, Chul Hee
    • Journal of Radiation Protection and Research
    • /
    • v.43 no.1
    • /
    • pp.10-19
    • /
    • 2018
  • Background: Monte Carlo (MC) simulation is the most accurate for calculating radiation dose distribution and determining patient dose. In MC simulations of the therapeutic accelerator, the characteristics of the initial electron must be precisely determined in order to achieve accurate simulations. However, It has been computation-, labor-, and time-intensive to predict the beam characteristics through predominantly empirical approach. The aim of this study was to analyze the relationships between electron beam parameters and dose distribution, with the goal of simplifying the MC commissioning process. Materials and Methods: The Varian Clinac 2300 IX machine was modeled with the Geant4 MC-toolkit. The percent depth dose (PDD) and lateral beam profiles were assessed according to initial electron beam parameters of mean energy, radial intensity distribution, and energy distribution. Results and Discussion: The PDD values increased on average by 4.36% when the mean energy increased from 5.6 MeV to 6.4 MeV. The PDD was also increased by 2.77% when the energy spread increased from 0 MeV to 1.019 MeV. In the lateral dose profile, increasing the beam radial width from 0 mm to 4 mm at the full width at half maximum resulted in a dose decrease of 8.42% on the average. The profile also decreased by 4.81% when the mean energy was increased from 5.6 MeV to 6.4 MeV. Of all tested parameters, electron mean energy had the greatest influence on dose distribution. The PDD and profile were calculated using parameters optimized and compared with the golden beam data. The maximum dose difference was assessed as less than 2%. Conclusion: The relationship between the initial electron and treatment beam quality investigated in this study can be used in Monte Carlo commissioning of medical linear accelerator model.

A comparative study of different radial basis function interpolation algorithms in the reconstruction and path planning of γ radiation fields

  • Yulong Zhang;Jinjia Cao;Biao Zhang;Xiaochang Zheng;Wei Chen
    • Nuclear Engineering and Technology
    • /
    • v.56 no.7
    • /
    • pp.2806-2820
    • /
    • 2024
  • Accurate reconstruction of radiation field and path planning are very important for the safety of operators in the process of dismantling nuclear facilities. Based on radial basis function (RBF) interpolation algorithm, this paper discussed the application of inverse multiquadric radial basis Function (IMRBF) interpolation method to the reconstruction of gamma radiation field, and proved the feasibility of reconstructing a radiation field with multiple γ sources. The average relative errors of IMRBF interpolation results were 4.28% and 8.76%, respectively, for the experimental scenarios with single and double gamma sources. After comparing the consistency between the simulated scene and the experimental scene, IMRBF method and Cubic Spline method were respectively used to reconstruct the gamma radiation field by Geant4 simulation data. The results showed that the interpolation accuracy of IMRBF method was superior to that of Cubic Spline method. Further, more RBF interpolation algorithms were used to reconstruct the multi-γ source radiation field, and then the Probabilistic Roadmap (PRM) algorithm was used to optimize the human walking path in the radiation field reconstructed by different interpolation methods. The optimal paths in radiation fields generated by multiple interpolation methods were compared. The results herein contribute to a comprehensive understanding of RBF interpolation methods in reconstructing γ radiation fields and their application in optimizing paths in radiation environments. The insights may provide valuable information for decision-making in radiation protection during the decommissioning of nuclear facilities.

Development of SiPM-based Small-animal PET

  • Lee, Jin Hyung;Lee, Seung-Jae;Chung, Yong Hyun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.4 no.5
    • /
    • pp.324-329
    • /
    • 2015
  • A decreased number of readout method is investigated to provide precise pixel information for small-animal positron emission tomography (PET). Small-animal PET consists of eight modules, and each module is composed of a $6{\times}6$ array of $2{\times}2{\times}20mm^3$ lutetium yttrium orthosilicate (LYSO) crystals optically coupled to a $4{\times}4$ array of $3{\times}3mm^2$ silicon photomultipliers (SiPMs). The number of readout channels is reduced by one-quarter that of the conventional method by applying a simplified row and column matrix algorithm. The performance of the PET system and detector module was evaluated with Geant4 Application for Emission Tomography (GATE) 6.1 and DETECT2000 simulations. In the results, all pixels of the $6{\times}6$ LYSO array were decoded well, and the spatial resolution and sensitivity, respectively, of the PET system were 1.75 mm and 4.6% (@ center of field of view, energy window: 350-650 keV).

Study on the PET image quality according to various scintillation detectors based on the Monte Carlo simulation

  • Eunsoo Kim;Chanrok Park
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.2
    • /
    • pp.129-132
    • /
    • 2023
  • Purpose: Positron emisson tomography (PET) is a crucial medical imaging scanner for the detection of cancer lesions. In order to maintain the improved image quality, it is crucial to apply detectors of superior performance. Therefore, the purpose of this study was to compare PET image quality using Monte Carlo simulation based on the detector materials of BGO, LSO, and LuAP. Materials and Methods: The Geant4 Application for Tomographic Emission (GATE) was used to design the PET detector. Scintillations with BGO, LSO and LuAP were modelled, with a size of 3.95 × 5.3 mm2 (width × height) and 25.0 mm (thickness). The PET detector consisted of 34 blocks per ring and a total of 4 rings. A line source of 1 MBq was modelled and acquired with a radius of 1 mm and length of 20 mm for 20 seconds. The acquired image was reconstructed maximum likelihood expectation maximization with 2 iteration and 10 subsets. The count comparison was carried out. Results and Discussion: The highest true, random, and scatter counts were obtained from the BGO scintillation detector compared to LSO and LuAP. Conclusion: The BGO scintillation detector material indicated excellent performance in terms of detection of gamma rays from emitted PET phantom.

Investigation on backscatter According to Changed in Components of Linear Accelerator Using Monte Carlo Simulation (몬테카를로 시뮬레이션을 이용한 선형가속기 구성요소 변화에 따른 후방산란에 관한 연구)

  • Kim, Hwein;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.9 no.4
    • /
    • pp.239-247
    • /
    • 2015
  • It should be accurate dose calculation to increase the efficiency of radiation therapy, and it is priority to figure out the beam characteristics for this purpose. The target and primary collimator in head components of the linear accelerator have the greatest influence on determining the beam characteristics which is caused by backscatter and it is the factor to consider the shielding structures and equipment management. In this study, we made modeling of the linear accelerator through the Geant4 Monte Carlo simulation and investigated backscatter according to the change of the size and shape in head components. For the scattered electrons, it showed the greatest number of distributions inside of the inner radius at primary collimator. But, for the scattered photons which have the high energy, it was mostly located outside of the inner radius at primary collimator. Scattered positrons showed a small occurrence in about 0.03%. According to the change of the inner radius at primary collimator, it was great changes in the inside of inner radius for all three scattered particles. According to the change of the outer radius at primary collimator, it was shown some considerable effects from more than 60 mm outer radius. It was no significant effect according to the change of target thickness. In this study, we found that backscatter should be considered, and figured out that geometric size and shape of the peripheral components are the factors that influences the backscatter effect.

Characterization of Physical Processes and Secondary Particle Generation in Radiation Dose Enhancement for Megavoltage X-rays (MV X선의 방사선 선량 증강 현상에서 물리적 특성과 이차입자의 발생)

  • Hwang, Chulhwan;Kim, JungHoon
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.5
    • /
    • pp.791-799
    • /
    • 2019
  • We evaluated the physical properties that occur to dose enhancement and changes from secondary particle production resulting from the interaction between enhancement material. Geant4 was used to perform a Monte Carlo simulation, and the medical internal radiation dose (MIRD) head phantom were employed. X-rays of 4, 6, 10, 15, 18, and 25 MV were used. Aurum (Au) and gadolinium (Gd) were applied within the tumor volume at 10, 20, and 30 mg/g, and an experiment using soft tissue exclusively was concomitantly performed for comparison. Also, particle fluence and initial kinetic energy of secondary particle of interaction were measured to calculate equivalent doses using the radiation weight factor. The properties of physical interaction by the radiation enhancement material showed the great increased in photoelectric effect as compared to the compton scattering and pair production, occurred with the highest, in aurum and gadolinium it is shown in common. The photonuclear effect frequency increased as the energy increased, thereby increasing secondary particle production, including alpha particles, protons, and neutrons. During dose enhancement using aurum, a maximum 424.25-fold increase in the equivalent dose due to neutrons was observed. This study was Monte Carlo simulation corresponds to the physical process of energy transmission in dose enhancement. Its results may be used as a basis for future in vivo and in vitro experiments aiming to improve effects of dose enhancement.

Image Optimization of Fast Non Local Means Noise Reduction Algorithm using Various Filtering Factors with Human Anthropomorphic Phantom : A Simulation Study (인체모사 팬텀 기반 Fast non local means 노이즈 제거 알고리즘의 필터링 인자 변화에 따른 영상 최적화: 시뮬레이션 연구)

  • Choi, Donghyeok;Kim, Jinhong;Choi, Jongho;Kang, Seong-Hyeon;Lee, Youngjin
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.453-458
    • /
    • 2019
  • In this study we analyzed the tendency of the image characteristic by changing filtering factor for the proposed fast non local means (FNLM) noise reduction algorithm with designed Male Adult mesh (MASH) phantom through Geant4 application for tomographic emission (GATE) simulation program. To accomplish this purpose, MASH phantom for human copy was designed through the GATE simulation program. In addition, we acquired degraded image by adding Gaussian noise with a value of 0.005 using the MATALB program in MASH phantom. Moreover, in degraded image, the FNLM noise reduction algorithm was applied by changing the filtering factors, which set to 0.005, 0.01, 0.05, 0.1, 0.5, and 1.0 value, respectively. To quantitatively evaluate, the coefficient of variation (COV), signal to noise ratio (SNR), and contrast to noise ratio (CNR) were calculated in reconstructed images. Results of the COV, SNR and CNR were most improved in image with a filtering factor of 0.05 value. Especially, the COV was decreased with increasing filtering factor, and showed nearly constant values after 0.05 value of the filtering factor. In addition, SNR and CNR were showed that improvement with increasing filtering factor, and deterioration after 0.05 value of the filtering factor. In conclusion, we demonstrated the significance of setting the filtering factor when applying the FNLM noise reduction algorithm in degraded image.

A detector system for searching lost γ-ray source

  • Khan, Waseem;He, Chaohui;Cao, Yu;Khan, Rashid;Yang, Weitao
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1524-1531
    • /
    • 2020
  • The aim of this work is to develop a Geiger-Muller (GM) detector system for robot to look for a radioactive source in case of a nuclear emergency or in a high radiation environment. In order to find a radiation source easily, a detector system, including 3 detectors, was designed to search γ-ray radiation sources autonomously. First, based on GEANT4 simulation, radiation dose rates in 3 Geiger-Muller (GM) counters were simulated at different source-detector distances, distances between detectors and angles. Various sensitivity analyses were performed experimentally to verify the simulated designed detector system. A mono-energetic 137Cs γ-ray source with energy 662 keV and activity of 1.11 GBq was used for the observation. The simulated results were compared with the experimental dose rate values and good agreements were obtained for various cases. Only based on the dose rates in three detectors, the radiation source with a specific source activity and angle was localized in the different location. A method was adopted with the measured dose rates and differences of distances to find the actual location of the lost γ-ray source. The corresponding angles of deviation and detection limits were calculated to determine the sensitivity and abilities of our designed detector system. The proposed system can be used to locate radiation sources in low and high radiation environments.

SIMULATION OF THE TISSUE EQUIVALENT PROPORTIONAL COUNTER IN THE INTERNATIONAL SPACE STATION WITH GEANT4 (Geant4를 활용한 국제우주정거장 내의 조직등가비례계수기 모의 실험)

  • Pyo, Jeong-Hyun;Lee, Jae-Jin;Nam, Uk-Won;Kim, Sung-Hwan;Kim, Hyun-Ok;Lim, Chang-Hwy;Park, Kwi-Jong;Lee, Dae-Hee;Park, Young-Sik;Moon, Myung-Kook
    • Publications of The Korean Astronomical Society
    • /
    • v.27 no.3
    • /
    • pp.81-86
    • /
    • 2012
  • The International Space Station (ISS) orbits the Earth within the inner radiation belt, where high-energy protons are produced by collisions of cosmic rays to the upper atmosphere. About 6 astronauts stay in the ISS for a long period, and it should be important to monitor and assess the radiation environment in the ISS. The tissue equivalent proportional counter (TEPC) is an instrument to measure the impact of radiation on the human tissue. KASI is developing a TEPC as a candidate payload of the ISS. Before the detailed design of the TEPC, we performed simulations to test whether our conceptual design of the TEPC will work propertly in the ISS and to predict its performance. The simulations estimated that the TEPC will measure the dose equivalent of about 1:1 mSv during a day in the ISS, which is consistent with previous measurements.

Efficient Determination of Iteration Number for Algebraic Reconstruction Technique in CT (CT의 대수적재구성기법에서 효율적인 반복 횟수 결정)

  • Joon-Min, Gil;Kwon Su, Chon
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.1
    • /
    • pp.141-148
    • /
    • 2023
  • The algebraic reconstruction technique is one of the reconstruction methods in CT and shows good image quality against noise-dominant conditions. The number of iteration is one of the key factors determining the execution time for the algebraic reconstruction technique. However, there are some rules for determining the number of iterations that result in more than a few hundred iterations. Thus, the rules are difficult to apply in practice. In this study, we proposed a method to determine the number of iterations for practical applications. The reconstructed image quality shows slow convergence as the number of iterations increases. Image quality 𝜖 < 0.001 was used to determine the optimal number of iteration. The Shepp-Logan head phantom was used to obtain noise-free projection and projections with noise for 360, 720, and 1440 views were obtained using Geant4 Monte Carlo simulation that has the same geometry dimension as a clinic CT system. Images reconstructed by around 10 iterations within the stop condition showed good quality. The method for determining the iteration number is an efficient way of replacing the best image-quality-based method, which brings over a few hundred iterations.