• 제목/요약/키워드: GE matrix

검색결과 61건 처리시간 0.029초

Tissue Inhibitor of Metalloproteinases-2 Inhibits the 4-Aminophenylmercuric Acetate-Induced Activation and Autodegradation of the Free Promatrix Metalloproteinase-2

  • Jo, Yi-Hyung;Yoon, Dae-Woong;Kim, Min-Young;Lee, Yoon-Ju;Kim, Hwa-Jung;Lee, Seung-Taek
    • BMB Reports
    • /
    • 제32권1호
    • /
    • pp.60-66
    • /
    • 1999
  • Matrix metalloproteinase-2 (MMP-2; 72-kDa gelatinase; 72-kDa type IV collagenase; gelatinase A) plays an important role in normal physiological processes and in many pathologic processes such as arthritis and metastasis of cancer. Tissue inhibitor of metalloproteinases-2 (TIMP-2) binds to proMMP-2 or mature MMP-2 at a 1:1 ratio and inhibits the catalytic activity of MMP-2. We demonstrated that the baculovirus/insect cell system does not have TIMP-2 activity. The human proMMP-2 free of TIMP-2 was expressed in the expression system and purified by one-step affinity chromatography using gelatin-Sepharose. The free proMMP-2 was autoactivated to the mature MMP-2 and autodegraded into smaller molecular weight forms in the absence of external activator. The activation and autodegradation of the proMMP-2 was much more rapid in the presence of 4-aminophenylmercuric acetate (APMA). Addition of TIMP-2 inhibits both APMA-induced activation and autodegradation of the free proMMP-2. However, an increasing concentration of TIMP-2 more readily inhibited activation of the free proMMP-2 than autodegradation. These results demonstrate that TIMP-2 plays roles in inhibition of both activation and autodegradation of the free proMMP-2 in addition to inhibition of the catalytic activity of MMP-2.

  • PDF

Microcrystalline cellulose에 자유 라디칼을 이용한 methyl methacrylate의 그래프팅 반응과 이를 이용한 천연복합필름의 제조 (Grafting of MMA onto MCC through free radical method and its application to all natural cellulose composite film preparation)

  • 이수;박상희;진석환;이선영
    • 한국응용과학기술학회지
    • /
    • 제25권4호
    • /
    • pp.459-468
    • /
    • 2008
  • Methyl methacrylate(MMA) was grafted onto microcrystalline cellulose(MCC) with ceric ammonium nitrate(CAN) as a redox initiator at the various conditions. The cellulose triacetate(CTA) composite films added MCC and MMA-grafted MCC powders were prepared on a glass plate. The graft yield(GY) and graft efficiency(GE) of the grafted MCC were calculated with the simple equations by the weight balance method. The double bond of C=O on the grafted MCC surfaces was confirmed by the fourier transform infrared spectroscopy with attenuated total reflection(FT-IT ATR) spectrophotometer. After grafting, the degree of crystallinity of cellulose powders was decresed by judging from x-ray diffraction(XRD) data. Scanning electron microscope(SEM) photos showed the only solvent and CAN solution could change the roughness of MCC powders and the effect of powder dispersions in composite matrix. The tensile strength of MCC/CTA composite films was decreased with increase of MCC powder contents. When 5% grafted MCC was added, the tensile strength of grafted MCC/CTA composite films was increased from 82.3 MPa to 97.2 MPa. The thermal property of powders was also analyzed by the thermogravimetric analysis(TGA).

조영제 사용 전 후 확산강조영상 검사의 비교 분석에 대한 연구 (A Study on Comparative Analysis of Diffusion Weighted Image Examination before and after Contrast Injection)

  • 구은회
    • 대한디지털의료영상학회논문지
    • /
    • 제11권2호
    • /
    • pp.51-57
    • /
    • 2009
  • The purpose of this study would evaluate if having clinical effects on diffusion image with quantitative analysis through ADC values of brain's normal tissue and lesions before and after contrast injections using a 3.0T. From November in 2007 until December in 2008, a total of 32 patient was performed on 3.0T(Signa Excite, GE Medical System, USA) with the normal or lesions in the patient who requests diffusion weighted image with 8channel head coil. The pulse sequence was used with spin echo EPI(TR: 10000msec, TE: 72.2 msec, Matrix: 128*128, FOV: 240 mm, NEX: 1, diffusion direction: 3, b-value: 1000). Measurement results of ADC values on lesions, CSF, white matter, gray matter, lesions after contrast injection were measured less 75% than before contrast injection, infarction: 100%, CSF: 78%(high), white matter: 71.4%(low), gray matter: 50%(high, low). The results of paired t-test on the deference of ADC values which statically is significant in three(lesions, CSF, white matter)regions except for white matter(p<0.05). Quantitative analysis of lesions, CSF, white matter, gray matter have difference on all regions. ADC values were low in lesions and white matter, normal CSF after contrast injection commonly is high than before contrast injection, ADC values which white matter were high and low (50:50) after contrast injection. 3.0T diffusion weighted image clinically supposed that performing DWI examination after contrast injection was not desirable because of having effects on brain tissue.

  • PDF

$KD_2PO_4$의 결정구조: 중성자와 X-선 회절에 의한 연구 (Crystal Structure of $KD_2PO_4$: Neutron and X-ray Diffraction Studies)

  • 김신애;심해섭;이창희
    • 한국결정학회지
    • /
    • 제11권3호
    • /
    • pp.162-166
    • /
    • 2000
  • KD₂PO₄ single crystals were grown from D₂O with reagent KH₂PO₄ and the crystal structure was determined by X-ray and neutron diffraction methods. The crystals are tetragonal at room temperature, I42d, with lattice parameters of a=7.4633(7), c=6.9785(5) Å and Z=4. Intensity data were collected on an Enraf-nonius CAD4 diffractometer with a graphite monochromated MoK/sub α/ radiation (λ=0.7107Å) and on the neutron four circle single crystal diffractometer with Ge(331) monochromated neutron beam (λ=0.997Å). The structure was refined by full-matrix least-square to final R and wR values of 0.030 and 0.072, respectively, for 204 observed reflections with I>2σ(I) by X-ray diffraction and to final R=0.041 and wR=0.096 for 144 observed relfecdtions by neutron diffraction. The O…O distance of 2.516(4)Å obtained by X-ray diffraction is the same as that of 2.515(4)Å by neutron diffraction. On the other hand, the O-D/H distance of 0.84(4)Å by X-ray diffraction is considerably shorter than 1.029(7) Åby neutron diffraction. Hydrogen and deuterium can be readily distinguished by neutrons. In this crystal 66% of H-positions were substituted by D and the rest 34% occupied by H. The phase transition temperature of DKDP obtained with deuteration levels is f193K. This value agrees fairly well with the result of DSC measurement. The nuclear density distribution by neutron diffraction provides an observation of the disordered state of D/H in KD₂PO₄ at room temperature.

  • PDF

Performance validation and application of a mixed force-displacement loading strategy for bi-directional hybrid simulation

  • Wang, Zhen;Tan, Qiyang;Shi, Pengfei;Yang, Ge;Zhu, Siyu;Xu, Guoshan;Wu, Bin;Sun, Jianyun
    • Smart Structures and Systems
    • /
    • 제26권3호
    • /
    • pp.373-390
    • /
    • 2020
  • Hybrid simulation (HS) is a versatile tool for structural performance evaluation under dynamic loads. Although real structural responses are often multiple-directional owing to an eccentric mass/stiffness of the structure and/or excitations not along structural major axes, few HS in this field takes into account structural responses in multiple directions. Multi-directional loading is more challenging than uni-directional loading as there is a nonlinear transformation between actuator and specimen coordinate systems, increasing the difficulty of suppressing loading error. Moreover, redundant actuators may exist in multi-directional hybrid simulations of large-scale structures, which requires the loading strategy to contain ineffective loading of multiple actuators. To address these issues, lately a new strategy was conceived for accurate reproduction of desired displacements in bi-directional hybrid simulations (BHS), which is characterized in two features, i.e., iterative displacement command updating based on the Jacobian matrix considering nonlinear geometric relationships, and force-based control for compensating ineffective forces of redundant actuators. This paper performs performance validation and application of this new mixed loading strategy. In particular, virtual BHS considering linear and nonlinear specimen models, and the diversity of actuator properties were carried out. A validation test was implemented with a steel frame specimen. A real application of this strategy to BHS on a full-scale 2-story frame specimen was performed. Studies showed that this strategy exhibited excellent tracking performance for the measured displacements of the control point and remarkable compensation for ineffective forces of the redundant actuator. This strategy was demonstrated to be capable of accurately and effectively reproducing the desired displacements in large-scale BHS.

Cerebrocortical Regions Associated with Implicit and Explicit Memory Retrieval Under the Conceptual Processing: BOLD Functional MR Imaging

  • 김형중;강형근;서정진;정광우;은성종;박진균;윤웅;박태진
    • 대한자기공명의과학회:학술대회논문집
    • /
    • 대한자기공명의과학회 2002년도 제7차 학술대회 초록집
    • /
    • pp.111-111
    • /
    • 2002
  • Purpose: This study is to compare the distinct brain activation between implicit and explicit memory retrieval tasks using a non-invasive blood-oxygenation-level-dependent (BOLD) functional magnetic resonance imaging(fMRI). Materials & Methods: We studied seven right-handed, healthy volunteers aged 21-25 years(mean;22 years) were scanned under a 1.5T Signa Horizon Echospeed MR imager(GE Medical Systems, Milwaukee, U.S.A.). During the implicit and explicit memory retrieval tasks of previously teamed words under the conceptual processing, we acquired fMRI data using gradient-echo EPI with 50ms TE, 3000ms TR, 26cm${\times}$26cm field-of-view, 128${\times}$128 matrix, and ten slices(6mm slice thickness, 1 mm gap) parallel to the AC-PC(anterior commissure and posterior commissure) line. By using the program of statistical parametric mapping(SPM99), functional activation maps were reconstructed and quantified.

  • PDF

EPDM 고무/유기 벤토나이트 복합체의 제조: 개질된 벤토나이트와 최종 생성물의 특성에 대한 염산의 영향 (Fabrication of EPDM Rubber/Organo-bentonite Composites: Influence of Hydrochloric Acid on the Characteristics of Modified Bentonite and Final Products)

  • ;;조을룡
    • 폴리머
    • /
    • 제38권1호
    • /
    • pp.62-68
    • /
    • 2014
  • 고무 매트릭스와 벤토나이트의 상용성을 향상시키기 위하여 유기개질 벤토나이트는 벤토나이트 현탁액에서 실란커플링제인 [3-(2-aminoethylamino)propyl]trimethoxysilane(AEAPTMS)]를 사용하여 합성되었다. 유기개질 벤토나이트의 구조와 특성을 FTIR-spectroscopy, thermogravimetric analysis(TGA) and X-ray diffraction(XRD) 등을 사용하여 분석하였다. Ethylene-propylene-diene monomer(EPDM) 고무와 유기 벤토나이트를 two-roll mill에서 배합하였으며 가황을 하고 물성을 측정하였다. 벤토나이트 개질에 대하여 염산과 물의 농도가 복합체의 물성에 중요한 영향을 미치는 것으로 확인되었다. 벤토나이트의 함량이 20 phr 포함된 복합체의 경우 가장 좋은 물성을 나타내었고 인장강도는 1.95에서 4.8 MPa로 증가되었으며 신장률은 300에서 500%로 증가하는 경향을 보였다.

갑상샘 스캔 정량분석을 통한 갑상샘 섭취율 동시계측법 연구 (Study of Simultaneous Counting of Thyroid Uptake with Quantitative Analysis of Thyroid Scans)

  • 김정수;김근우
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제46권5호
    • /
    • pp.401-408
    • /
    • 2023
  • Thyroid uptake measurements can be subject to measurement errors due to the scoping and positioning of the thyroid gland. To compensate for these limitations, the clinical utility of the thyroid simultaneous counting method as an alternative to thyroid uptake measurement was analyzed and evaluated experimentally through quantitative analysis of images acquired after thyroid scanning. Experimental data were obtained using a Gamma camera (GE infinia), a thyroid uptake system (KOROID 1), and a thyroid neck phantom. Based on the thyroid uptake rate of 1-5% according to the protocol of thyroid scan test (99mTcO4 - , 370 MBq) in normal results, 99mTcO4 - was set in the range of 3.7-18.5 MBq (Matrix: 256×256, Scan time: 1 min, collimator: pin hole, phantom-collimator distances: 7 cm). The acquired images were corrected for the attenuation of isotopes due to the set-up time and half-life by applying the Auto Region of interest (ROI) drawing system, and the significance of the experimental results was evaluated by Multiple linear regression analysis (SPSS, ver. 22, IBM). The thyroid uptake rate showed a significant correlation between the dose and the measured counts when using the thyroid uptake system equipment. Meanwhile, the quantitative analysis counts of phantom images using Gamma camera also showed a significant correlation. Thus confirmed that the correlation between these two experiments was statistically significant (P<0.05). The simultaneous counting protocol, which indirectly measures thyroid uptake from thyroid scans, is likely to be clinically relevant if complemented by additional studies with different variables in patients with thyroid disease.

자기공명영상에서 ACR 팬텀을 이용한 잡음전력스펙트럼 평가 (Evaluation of the Noise Power Spectrum by Using American College of Radiology Phantom for Magnetic Resonance Imaging)

  • 민정환;정회원
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제47권1호
    • /
    • pp.21-28
    • /
    • 2024
  • This study was purpose to quantitative evaluation of comparison of the image intensity uniformity and noise power spectrum (NPS) by using American college of radiology (ACR) phantom for magnetic resonance imaging (MRI). The MRI was used achiva 3.0T MRI and discovery MR 750, 3.0T, the head and neck matrix shim SENSE head coil were 32 channels receive MR coil. The MRI was used parameters of image sequence for ACR standard and general hospital. NPS value of the ACR standard T2 vertical image in GE equipment was 7.65E-06 when the frequency was 1.0 mm-1. And the NPS value of the ACR hospital T1 region of interest (ROI) 9 over all vertical image in Philips equipment was 9E-08 when the frequency was 1.0 mm-1 and the NPS value of the hospital T2 ROI 9 over all vertical image in Philips equipment was 1.06E-07 when the frequency was 1.0 mm-1. NPS was used efficiently by using a general hospital vertical sequence more than the standard vertical sequence method by using the ACR phantom. Furthermore NPS was the quantitative quality assurance (QA) assessment method for noise and image intensity uniformity characteristics was applied mutatis mutandis, and the results values of the physical imaging NPS of the 3.0T MRI and ACR phantom were presented.

뇌종야의 관류 자기공명영상: 예비보고 (Perfusion MR Imaging of the Brain Tumor: Preliminary Report)

  • 김홍대;장기현;성수옥;한문희;한만청
    • Investigative Magnetic Resonance Imaging
    • /
    • 제1권1호
    • /
    • pp.119-124
    • /
    • 1997
  • 목적: 뇌종양에서 자기공명 뇌혈류량지도(MR cerebral blood volume map)의 유용성을 평가하고자 하였다. 대상 및 방법: 15예의 두개강내 종괴(다형성 교모세포종 2예, 저등급 교종 3예, 뇌농양 2예, 뇌수막종 3예, 신경세포종 1예, 배아종 1예, 방사선괴사 1예, 전이암 1예) 에서 관류 MR영상을 수술전에 시행하였다. 환자의 평균연령은 42세였고(22-68), 남자 10명, 여자 5명이었다. MR영상기기는 1.5T unit(Signa, GE Medical Systems, Milwaukee, Wisconsin)를 사용하였다. 조영제 주입후 조영제의 일차 통과시 나타나는 자화율을 얻었다. (조영제는 최오의 MR 촬영시작후 10초부터 시작하여, 총량 15cc 의 Gadopentate dimeglumine(Magnevist)를 약 2ml/sec의 속도로 손으로 주입하였다). 각 환자마다 160초 동안 6 slice에서 slice당 80 image씩 총 480 image를 얻었으며 interleaved single shot gradient EPI기법을 사용하였다. 영상변수는 TR 2000ms, TE 50ms, FOV $240{\times}240mm,{\;}matrix{\;}size{\;}128{\times}128$, slice thickness/gap 5/ 2.5mm, flip angle $90^{\circ}$로 하였다. 얻은 영상데이터는 GE workstation으로 전송한 후, 자체적으로 개발한 software에 의해 각 kvoxel마다 시간경과에 따른 신호크기의 로그변화곡선(${\Delta}R2^{*}=-In(S/S_0$)의 적분값을 구하여 국소뇌혈류량(rCBV)영상을 구성하였다. 이의 시각적 해석을 용이하게 하기 위해 정상 뇌백질의 관류정도를 기준으로 하여 상대적인 RGB 색수치로 변환하여, color rCBV map을 얻었다. 관류의 정도와 조영증강정도를 중심으로 관류 MR 영상소견과 조직학적 소견을 관련지어 분석하였다. 결과: 조영증강 T1강조MR영상에서 환상조영증강을 보이는 다형성 교보세포종 2예에서는 변연부 외륜이 고관류를, 중심부의 괴사부위는 저관류로 나타났다. 저등급 교종은 경계가 불분명한 저관류부위로 보였다. 뇌농양 2예는 변연부 외륜이 경도의 고관류를, 중심부는 저관류로 나타났다. 뇌수막종은 미만성의 균일한 중등도 혹은 고도의 고관류로 보였으며, 임파종과 배아종은 경계가 명확한 저관류부위로 나타났다. 신경세포종은 종괴\ulcorner 일부에 중등도 혹은 고도의 고관류부위가 관찰되었고, 전이암은 다수병변중 일부에서 중등도의 고관류를 보였다. 방사선괴사는 저관류부위내에 국소적 고관류부위를 보였다. 결론: 관류 MR영상은 뇌종양의 관류상태를 비교적 잘 반영하며, 조직학적 특성을 예측하는데에 도움을 주 수 있을 것으로 기대된다. 뇌종야에서의 관류MR영상의 분명한 역할을 규명하기 위해서는 앞으로 더 많은 임상적 연구가 필요할 것으로 생각된다.

  • PDF