• Title/Summary/Keyword: GC-FID

Search Result 257, Processing Time 0.047 seconds

Examination about evaluation method of odor active compounds in evaporator by using condensed water (응축수를 이용한 냉각기의 냄새원인물질 평가방법 검토)

  • Kim, Sun-Hwa;Kim, Kyung-Hwan;Jung, Young-Rim;Kim, Man-Goo;Kim, Jae-Ho;Park, Ha-Young;Ji, Yong-Jun
    • Analytical Science and Technology
    • /
    • v.20 no.5
    • /
    • pp.361-369
    • /
    • 2007
  • Uncomfortable odor emitted from air conditioning system is the main cause of indoor air quality deterioration. To solve evaporator odor problems, odor active compounds, have to be identified then the quality of the product can be improved its quality. Because evaporator odor in exhaust gas has low odor intensity and discontinuity, it is very difficult to collect and analyze sample. In this study through the identification of odor compounds in condensed water, the evaluation of the eraporator was tested. Odor compounds were extracted from water by headspace-solid-phase microextraction (HS-SPME) method. The single odor was separated by GC/FID/Olfactometry (GC/FID/O) and odor active compounds were identified by GC/AED and GC/MS. Compared to air sample, result of sensory evaluation and the single odor compound appeared similarly. It was identified that odor active compounds have functional group containing oxygen such as alcohols and acids. Evaluation method of odor active compounds using condensed water in evaporator appeared effective on the side of simplicity of collection, low expanse and rapid analysis.

Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD (열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구)

  • Kim, Man-Goo;Jung, Young-Rim;Seo, Young-Min;Nam, Sung-Hyun;Kwon, Young-Jin
    • Analytical Science and Technology
    • /
    • v.14 no.3
    • /
    • pp.274-285
    • /
    • 2001
  • In this study, the thermal desorption-cryofocusing-gas chromatographic(TD-C-GC) method was developed for determination of volatile organic compounds(VOCs) in ambient air and was applied at the municipal solid waste landfill sites. On-column cryofocusing was possible only with a 100 ml dewars bottle in TD-C-GC method with a stainless steel column. However, high operating pressure was needed for purging VOCs from the absorbent trap, which was able to solve by pressure programming with a electric pressure controller. By using both pressure and temperature programming brought increasing of resolution power in on-column cryofocusing method, but the high pressure caused a leakage of sample tube with repeated use. A loop cryofocusing devise was also developed and compared with the direct on-column method. In loop cryofocusing method, VOCs were concentrated on a 0.8mm i.d. loop which is located between the injector and separation column by using liquid nitrogen. In order to purge VOCs from the absorbent trap, only 0.4 psi of pressure was need in the loop cryofocusing method. Dual detection system was applied for the analysis of VOCs; a FID was used for hydrocarbons and a FPD was used for sulfur-containing compounds. Qualitative analysis was done by on-column cryofocusing GC-MS system. Among the large number of VOCs, toluene was the most abundant. Hydrogen sulfide, dimethyl sulfide, carbon disulfide, dimethyl disulfide and methyl propyl disulfide were detected at landfill site by FPD.

  • PDF

Determination of Lignan Compounds in Fruits of Schisandra chinensis BAILLON by Capillary-GC(FID) (Capillary-GC(FID)에 의한 오미자 Lignan 성분의 정량)

  • Sohn, Hyun-Joo;Bock, Jin-Young;Baik, Soon-Ok;Kim, Yong-Ha
    • Applied Biological Chemistry
    • /
    • v.32 no.4
    • /
    • pp.350-356
    • /
    • 1989
  • The determinabilities of several lignan compounds by capillary-GC (F1D) were studied. The lignan compounds used were deoxyschizandrin, gomisin N, schizandrin, wuweizisu C, gomisin A, angeloylgomisin H and tigloylgomisin H which were isolated from fruits of Schisandra chinensis BAILLON and identified with GC/MS(EI, 70eV), 1H-NMR(300MHz) and IR. The GC column used was SPB-1 fused silica capillary$(0.25mm\;ID{\times}30m,\;Supelco)$, and the column oven temperature was programmed from $200^{\circ}C$ to $300^{\circ}C$ at the rate of $4^{\circ}C$ per minute. The linearities between concentration and FID response were maintained in $2{\sim}500ppm$ of deoxyschizandrin and wuweizisu C and in $5{\sim}500ppm$ of gomisin N, schizandrin, gomisin A, angeloylgomisin H and tigloylgomisin H. The contents of lignan compounds in fruits of S. chinensis BAILLON produced at Moo-ju area were analyzed by the GC method: the values obtained of schizandrin and gomisin N were 6.5 and 5.9mg/g respectively, and those of gomisin A, wuweizisu C, angeloylgomisin H, deoxyschizandrin and tigloylgomisin H were $0.5{\sim}1.6mg/g$.

  • PDF

Simultaneous Analysis of Gasonline and Chlorinated Solvents by GC/FID-SPME

  • 안상우;이시진;장순웅
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.350-353
    • /
    • 2004
  • This study was conducted for a rapid and simple method using GC/FID and SPME to dectermin gasonline and chlorinated solvents simultaneity. A sodium chloride concentration of 25%(vol/w) combined with such as magnetic stirried, an absorption time of 20min, an extraction temperature of 4$0^{\circ}C$, the volume of minimized 50mL of gaseous phase and a desorption time of 5min pleprovided the greatest sensitivity while maintaining analytical efficiency. Analytical parameter such as linearity was also evaluated. The linear range extend from 30 to 500ppb. The results of chlorinated solvents and gasoline mixed samples showed that solvents have been completely removed from the sample preparation step and more accurated than those obtained by the other methods.

  • PDF

고체상 미량분석법(SPME)을 이용한 GC/FID에서의 BTEX 및 TCE 동시 분석

  • 이재선;장순웅;이시진
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2003.04a
    • /
    • pp.405-408
    • /
    • 2003
  • The soild phase microextraction(SPME)fiber which contains 100${\mu}{\textrm}{m}$ polydimethyl siloxane of a stationary phase was used for the analysis of volatile organic compounds contained in aqueous solution. volatile organic compounds, which were spiked in blank water and extracted by the headspace SPME techique, were analyzed by gas chromatography/flame ionization detector(GC/FID). The optimu condition of SPME fiber is determined that the analytes were extracted for 40min from extracts by using PDAfS100${\mu}{\textrm}{m}$ fiber. This new method could have wide application for the analysis of VOCs in aqueous solution.

  • PDF

Determination of Benzene in the Casting Process by GC-MS and GC (주조작업장 공기 중 벤젠의 정량)

  • Oh, Doe Suk;Lee, Byoung Jae;Lee, Seong Min;Kim, Young Ju
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.3
    • /
    • pp.206-211
    • /
    • 2001
  • This article describes identification and quantification of benzene in the casting process. Air samples around the casting process were taken by using personal air sampler attached charcoal tube and desorbed by carbon disulfide. The identification and quantitative analysis of benzene have been performed by GC-MS and GC-FID. Calibration range of standard solutions for benzene was prepared in range from 0.1 to 2 times of TLVs concentrations($1.4{\sim}28{\mu}g/1m{\ell}$ CS2) and the limit of detection was $0.11{\pm}0.002{\mu}g/1m{\ell}$ CS2. Benzene detected in airborne was ranged in 4.0ppb~104.7ppb.

  • PDF

Determination of Liquid Paraffins in Foods by Using GC-FID (GC-FID를 이용한 식품 중 유동파라핀 함량 분석)

  • Park, Se-Jong;Choi, Jae-Chun;Lim, Ho-Soo;Jang, Su-Jin;Kim, So-Hee;Kim, Meehye
    • Korean Journal of Food Science and Technology
    • /
    • v.45 no.5
    • /
    • pp.545-549
    • /
    • 2013
  • Liquid paraffin is a mixture of heavier alkanes derived from petroleum. It can be used as a lubricant in processing machinery, as a coating agent, or as a releasing agent. The purpose of this study was to analyze liquid paraffins in foods by using a gas chromatography-flame ionized detector (GC-FID). Liquid paraffin was extracted from the food samples using n-hexane. Non-polar aromatic or olefinic co-extractives were removed by alkaline permanganate oxidation followed by clean up on an aluminium oxide SPE cartridge before the GC-FID analysis. The results of recovery tests were 91.5-103.2%. Based on this optimized method, we investigated the amount of liquid paraffin in various food samples purchased from domestic markets. The levels of liquid paraffin in bread were $95.5{\pm}156.0$ mg/kg (0.008%), those in capsules were $40.2{\pm}54.5$ mg/kg (0.001%), and those in dried fruits and vegetables were $3.0{\pm}18.1$ mg/kg (0.0001%). No liquid paraffin was detected in fresh fruits and vegetables. We propose that our method can be used to monitor and detect liquid paraffin in foods for food safety management.

Determination of the Concentration of Panaxynol, Panaxydol and Panaxytrio1 by Capillary-GC(FID) (Capillary-GC(FID)에 의한 panaxynol, panaxydol 및 panaxytriol의 정량)

  • 노길봉;손현주
    • Journal of Ginseng Research
    • /
    • v.13 no.2
    • /
    • pp.183-188
    • /
    • 1989
  • A gas chromatographic method was developed for determination of the concentration of three major polyacetylene compounds in ginseng roots---panaxynol, panaxydol and panaxytriol. The column and the detector used were an SPB-1 fused silica capillary (0.2mm i.d.$\times$30m, Supelco) and a flame ionization detector (FID). The column oven temperature was kept at $250^{\circ}C$ isothermally The retention times of panaxynol, panaxydol and panaxytriol peaks were 4.2,5.1 and 6.9 min before TMS-derivatitration and 4.5,5.4 and 7.4 min after TMS-derivatization, respectively. The minimum determinable concentrations of panaxynol, panaxydol and panaxytriol before TMS-derivatiEation were at the 20, 50 and 100 ppm levels, while the concentrations of panaxydol and panaxytriol as well as panaxynol after TMS- derivatisation could be towered to the 5 ppm level. The panaxynol, panaxydol and panaxytriol contents in red ginseng were determined by use of this method after TMS-derivatization : the amounts obtained were 724, 721 and 71$\mu\textrm{g}$/g, respectively.

  • PDF

Determination of Carboxyl Drugs by Gas Chromatography-Flame Photometric Detector (가스크로마토그라피-염광광도 검출기에 의한 혈장중 카르복실기 함유 약물의 정량)

  • 박만기;조영현;유무영;강탁림
    • YAKHAK HOEJI
    • /
    • v.30 no.4
    • /
    • pp.180-184
    • /
    • 1986
  • Such carboxyl drugs as mefenamic acid, alclofenac, ketoprofen, cicloxilic acid and tolfenainic acid in rat plasma were determined by the gas chromatography flame photometric detector (GC-FPD). After methylthiomethyl (MTM) esterification with MTM-chloride in 1, 8-diazabicyclo [5.4.0] undec-7-ene (DBU) catalyst, determination of these drugs by this method was tried and compared with that by the GC-flame ionization detector (FID) method in respect to sensitivity and effect of inteferences. The results showed it was possible to analyze with accuracy by this method because of specificity of the FPD, although these drugs were not separated from interferences in plasma on GC column. The GC-FPD method was more sensitive than GC-FID method and the minimum detectable amount of monocarboxylic drugs on 3%, QF-1 column was about 15fmol/injection.

  • PDF