• 제목/요약/키워드: GC-FID

검색결과 257건 처리시간 0.033초

GC/FID와 GC/MS 분석법에 의한 목질제품에서의 VOC 방출특성 비교 (The Comparison of VOC Characteristics Emitted from Wood-based Panels Using GC/FID and GC/MS)

  • 황윤서;박현주;손윤석;김조천
    • 한국대기환경학회지
    • /
    • 제27권4호
    • /
    • pp.436-442
    • /
    • 2011
  • In this study, the Total Volatile Organic Compounds (TVOC) emitted from wood-based panels were compared by two analytical methods using the GC/FID and the GC/MS. Japanese Larch, Yellow Poplar, Particle Board (PB) and Medium Density Fiberboard (MDF) were selected as target materials. Major compounds emitted from the panels were Toluene, ${\alpha}$-pinene, ${\beta}$-pinene and limonene. In case of TVOC using GC/FID method, MDF E2 (1,497 ${\mu}g/m^3$) revealed the highest concentration among all wood-based panels, while Japanese Larch (1,772 ${\mu}g/m^3$) showed the highest value with respect to GC/MS method. Furthermore, it was found that the amount of VOC emitted from panels was different depending upon analytical methods. This significant difference was attributed to analytical sensitivities of GC/FID and GC/MS for various VOC. Besides, it was found that the composition ratios of main VOC compounds were not significantly different.

직독식 측정기 PID와 능동식 시료채취기에 의한 GC-FID 정량분석법의 VOCs 농도 비교 연구 (Comparative Analysis between Direct-reading Meter of PID and GC-FID using the Active Type Air Sampler for VOCs Measurement)

  • 여진희;최광민
    • 한국산업보건학회지
    • /
    • 제26권3호
    • /
    • pp.301-306
    • /
    • 2016
  • Objectives: Direct-reading instrument(Photoionization detectors, PID) and quantitative analysis using active type air sampling (Gas chromatography-flame ionization detector, GC-FID) were tested to evaluate their ability to detect volatile organic compounds(VOCs) in a semiconductor manufacturing plant. Methods: The organic compounds used were acetone and ethanol which are normally used as cleaning solutions in the semiconductor manufacturing. The evaluation was based on the preparation of test solutions of known acetone and ethanol concentration in a chamber($600{\times}600{\times}1150mm$). Samples were prepared that would be equivalent to 5~100 ppm for acetone and 10~ 200 ppm ethanol. GC-FID and PID were evaluated simultaneously. Quantitative analysis was performed after sampling and the direct-reading instrument was checked using real-time data logging. Results: Positive correlations between PID and GC-FID were found for acetone and ethanol at 0.04~2.4% for acetone(TLV: 500 ppm) and 0.1~8.3% for ethanol(TLV: 1000 ppm). When the sampling time was 15 min, concentration of test solution was the most similar between measurement methods. However, the longer the sampling time, the less similar the results. PID and GC-FID had similar exposure patterns. Conclusions: The results indicate that PID and GC-FID have similar exposure pattern and positive correlation for detection of acetone and ethanol. Therefore, PID can be used for exposure monitoring for VOCs in the semiconductor manufacturing industry. This study has significance in that it validates measuring occupational exposure using a portable device.

Development of Analytical Technology Using the HS-SPME-GC/FID for Monitoring Aromatic Solvents in Urine

  • Lee, Mi-Young;Chung, Yun Kyung;Shin, Kyong-Sok
    • Mass Spectrometry Letters
    • /
    • 제4권1호
    • /
    • pp.18-20
    • /
    • 2013
  • Headspace solid phase micro-extraction gas chromatography/flame ionization detection (HS-SPME-GC/FID) method was compared with headspace gas chromatography/mass selective detection (HS-GC/MS). Organic solvent-spiked urine as well as urine samples from workspace was analyzed under optimal condition of each method. Detection limit of each compound by HS-SPME-GC/FID was $3.4-9.5{\mu}g/L$, which enabled trace analysis of organic solvents in urine. Linear range of each organic solvent was $10-400{\mu}g/L$, with fair correlation coefficient between 0.992 and 0.999. The detection sensitivity was 4 times better than HS-GC/MS in selected ion monitoring (SIM) mode. Accuracy and precision was confirmed using commercial reference material, with accuracy around 90% and precision less than 4.6% of coefficient of variance. Among 48 urine samples from workplace, toluene was detected from 45 samples in the range of $20-324{\mu}g/L$, but no other solvents were found. As a method for trace analysis, SPME HS GC/FID showed high sensitivity for biological monitoring of organic solvent in urine.

2,4-DNPH와 가스크로마토그래프를 이용한 포름알데히드 분석방법 (Analytical method for analyzing formaldehyde using 2, 4-DNPH and gas chromatography/FID, NPD)

  • 정지연;박승현;이광용;오세민
    • 한국산업보건학회지
    • /
    • 제10권1호
    • /
    • pp.126-146
    • /
    • 2000
  • To develop and evaluate formaldehyde measurement method using 2,4-dinitro-phenylhydrazine (2,4-DNPH) coated sampler and gas chromatography, laboratory test and field test were conducted. Results of this study are as follows. Limit of detection(LOD) of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is $0.008{\mu}g/m{\ell}$ $0.060{\mu}g/m{\ell}$, $0.472{\mu}g/m{\ell}$ respectively. Coefficiency of measurement methods, HPLC-UVD, GC-NPD and GC-FID, is 0.008, 0.009, 0.020 respectively. Desorption efficiency of sep-pak xposure aldehyde sampler and sorbent sample tube is 1.05(range : 0.99 - 1.12), 1.02(range : 0.99 - 1.06) respectively. Samples of sorbent sample tube and sep-pak xposure aldehyde sampler turned out to be stored at refrigerator, according to storage test results. Measurement methods of HPLC-UVD, GC-NPD, GC-FID, according to results of precision for the combined sampling and analytical procedure, became acceptable to OSHA evaluation standard. Field test using exposure chamber met the NIOSH overall uncertainty recommendation(less than 25%). Overall uncertainty of Sepak-HPLC(UVD), Tube-GC(NPD), Tube-GC(FID) is 11.0% - 17.0%. Consequently gas chromatography(GC-NPD, GC-FID) and high performance liquid chromatography(EPA TO-11) using 2,4-DNPH coated sampler for formaldehyde measurement turned out to be suitable to measure personal formaldehyde exposure at workplaces.

  • PDF

냄새성분 측정을 위한 기체 크로마토그래피/불꽃이온화 검출/후각 검출법의 개발 (Method Development for the Odor-Active Compound Determination by Gas Chromatography/Flame Ionization Detection/Olfactometry)

  • 김만구;정영림;서영민;양희화
    • 분석과학
    • /
    • 제14권2호
    • /
    • pp.180-190
    • /
    • 2001
  • 화합물에 포함된 냄새를 유발하는 물질은 다양한 성분으로 되어 있다. 냄새를 유발하는 휘발성 화합물의 분석에는 GC 또는 GC/MSD 등이 많이 사용된다. 그러나, 이들 분석기기는 전체 휘발성 성분의 profile이나 특정성분의 함량을 정량적으로 분석할 수는 있으나, 냄새를 유발하는 지배적인 성분이 무엇인지 파악하기가 어렵다. 이러한 문제점을 해결하기 위해 사용되는 방법에는 GC-Sniffing 또는 GC-Olfactometry법 등이 있다. 본 연구에서는 복합적인 냄새성분을 검출하기 위해 사람의 후각을 이용하는 olfactometry를 기존 GC에 결합시켜 분리컬럼에서 분리된 시료가 동시에 검출되는 GC/FID/Olfactometry를 개발하였다. FID와 ODP 신호간의 시간차이는 물질의 종류와 농도, 그리고 패널에 따라 다르게 나타났다. 일반적으로 휘발성과 냄새강도는 큰 물질일수록, 패널의 호흡주기가 짧을수록 두 신호간의 시간차이가 적었다. 그러므로, 정확한 냄새 원인물질의 규명에는 이들 신호의 관계에 대한 고찰이 필요하다.

  • PDF

Quantitative and Classification Analyses of Lupenone and ${\beta}$-Sitosterol by GC-FID in Adenophora triphylla var. japonica Hara and Codonopsis lanceolata

  • Kim, Won Il;Zhao, Bing Tian;Lee, Je Hyun;Lee, Dong-Ung;Kim, Young Shik;Min, Byung Sun;Son, Jong Keun;Woo, Mi Hee
    • Natural Product Sciences
    • /
    • 제20권4호
    • /
    • pp.243-250
    • /
    • 2014
  • A simple GC method with a FID detector was developed in order to determine two main compounds (${\beta}$-sitosterol and lupenone) for Adenophorae Radix. ${\beta}$-Sitosterol and lupenone were analyzed by the gradient thermal ramping method. Nitrogen was used as the carrier gas at 108 kPa. The flow rate of gas was 2.0 mL/min; $2{\mu}L$ of filtered sample was injected at a split ratio of 1 : 80. This method was fully validated with respect to linearity, precision, accuracy and robustness. Further, this GC-FID method was applied successfully in order to quantify two compounds in an Adenophorae Radix extract. The GC analytical method for classification analysis was performed by repeated analysis of 59 reference samples in order to differentiate between Adenophora triphylla var. japonica Hara and 14 Codonopsis lanceolata. The results indicate that the GC-FID method is suitable and reliable for the quality evaluation of Adenophorae Radix.

열탈착/GC/FID를 이용한 B, T, X 분석의 정확도 및 정밀도 평가 (A Study on Evaluation of Accuracy and Precision on B, T, X Analysis Using Thermal Desorption/Gas Chromatograph/Flams Ionization Detector)

  • 박정근;유기호
    • 한국대기환경학회지
    • /
    • 제16권3호
    • /
    • pp.265-275
    • /
    • 2000
  • By using thermal desorption/gas chromatograph/flame ionization detector(TD/GC/FID), this study was carried out to evalute an accuracy and a precision on Benzene(B), Toluene(T), o-Xylene(X) analysis in an industrial hygiene laboratory. Limits of detection of TD/GC/FID on B, T, X were showed 13.75ng/sample or less. For the accuracy of the method by concentration levels, overall bias was showed 7.7% as an absolute value, and the pooled coefficient of variation showed 3.51%. For the precision on repeatability of peak area and retention time between within-run and between-run of analytical system, it is showed the results of within-run gave better than those of between-run. Also the accuracy by sorbents(Tenax TA and Chromosorb 106)was evaluated, and the precision on reproducibility between MDHS72 and this study was compared. It is showed it is possible for TD/GC/FID to evaluate accurately B, T, X concentration levels of less than 1ppm at indoor or outdoor of workplaces in Korea.

  • PDF

고체상미량분석법(SPME)을 이용한 GC/FID에서 PCE 및 TCE 최적 분석법 (The Optimal Analytical Method for the Determination of PCE and TCE by GC/FID with SPME technieque)

  • 안상우;이시진;장순웅
    • 한국환경과학회지
    • /
    • 제13권10호
    • /
    • pp.903-909
    • /
    • 2004
  • A new method based on solid phase microextraction(SPME), coupled with GC/FID, has been developed for the determination of PCE and TCE in water samples. The experimental parameters affecting the SPME process (i.e, kinds of fibers, extraction time, desorption time, extraction temperature, volume ratio of sample to headspace, salt addition, and magnetic stirring) were optimized. The coefficients of determination ($R^2$) for PCE and TCE were 0.9951 and 0.9831, respectively when analytes concentration ranges from 10 to 300$\mu$g/L. The relative standard deviations were 3.4 and $2.1\%$ for concentration of 10$\mu$g/L(n=5), respectively. The detection limits of PCE and TCE were 0.5 and l.3$\mu$g/L, respectively.

GC/FID에서 천연가스 성분의 직선성 불확도 추정 (An evaluation of uncertainty for natural gas component in GC/FID linearity)

  • 김영구;한재식;황현철;김용완;김진준
    • 한국가스학회:학술대회논문집
    • /
    • 한국가스학회 2007년도 춘계학술발표회 논문집
    • /
    • pp.42-49
    • /
    • 2007
  • 가스크로마토그래피 불꽃이온화검출기(FID)에서, 천연가스 표준물질만을 사용하여 분석할 때 발생할 수 있는 분석 불확도에 대하여 연구하였다. 일반적으로 $10^5$ 범위 농도까지 직선성이 확보된 것으로 알려진 FID 검출기에 대하여 실제 분석에서 동일한 직선성이 확보되는지를 확인하였다. 본 연구에서 7성분으로 조성된 천연가스용 표준가스를 샘프링 loop의 크기를 1.0mL, 0.50mL, 0.25mL로 변환시키면서 GC/FID를 사용하여 분석한 상대표준불확도 결과는 다음과 같다. 메탄은, 0.458 %, 에탄은 0.20247%, 프로판은 0.1497%, i-부탄은 0.1854 %, n-부탄은 0.2977%, i-펜탄은 0.263%, n-펜탄은 0.383%이었다. 각 경우에서 직선성 상대표준불확도값이 $0.15%{\sim}0.45 %$까지 이른다. 일반적으로 농도가 높은 메탄의 경우에 직선성 불확도값이 큰 값을 보여 주었고 농도범위가 1-5%인 $C2{\sim}C5$의 경우는 작은 직선성 표준불확도를 나타내었다.

  • PDF