• Title/Summary/Keyword: GC method

Search Result 1,479, Processing Time 0.024 seconds

A Rapid, Simple Determination of Sulfur-containing Compounds and Methylmalonic Acid on Plasma using GC-MS-SIM for the Diagnosis of Homocysteinemia (혈장 중 황함유 화합물과 메틸말론산의 신속 간편한 분석법 개발; GC-MS-SIM을 이용한 호모시스테인혈증의 진단)

  • Yoon, Hye-Ran;Thapa, Maheshwor
    • Journal of The Korean Society of Inherited Metabolic disease
    • /
    • v.15 no.3
    • /
    • pp.138-146
    • /
    • 2015
  • Purpose: If early diagnosis is not made, patients with metabolic disorders as homocystinemia rapidly progress to physical defect or mental retardation resulted in storage of the toxic material into the brain. Therefore, it is necessary to develop an analytical method for a rapid screening and/or correct confirmation diagnosis. Methods: The standard solution of sulfur amino acids spiked plasma was subjected to protein precipitation with methanol, and then consecutively derivatized with trimethylsilyl (TMS) and trifluoroacyl (TFA) and determined by GC-MS. The formation of TMS derivative of the hydroxyl and TFA derivative of amino functional group was performed by BSTFA and MBTFA, respectively. Selective ion monitoring (SIM) mode was used for quantification with selected specific ions. Results: A calibration curve on standard spiked pooled plasma showed a linear relationship with correlation coefficient of 0.9936-0.9992 for all compounds over the range of 0.1-300 ng. The precision and accuracy were within S.D. of 1-15% and RSD of 1-15% for intra-day assay at 2 ng/mL, 15 ng/mL and 30 ng/mL. LOD and LOQ was 0.4 ng/mL and 4 ng/mL respectively. Conclusion: A rapid analytical method was developed to quantify sulfur amino acids and methyl malonic acid, after two-step derivatization procedure with good sensitivity and specificity on human plasma. Advantages of a new method are simplicity and rapidity. The method could be useful for routine analysis, diagnosis of homocysteinemia.

Chemical Derivatization of Catecholamines for Gas Chromatography-Mass Spectrometry

  • Park, Sun-Young;Kang, Bo-Xin;Li, Quing;Kim, Hoon-Sik;Lee, Jun-Gae;Hong, Jong-Ki
    • Bulletin of the Korean Chemical Society
    • /
    • v.30 no.7
    • /
    • pp.1497-1504
    • /
    • 2009
  • GC/MS analysis of catecholamines (CAs) in biological sample may produce poor reproducible quantitaion when chemical derivatization is used as the technique to form a volatile derivative. Significant quantities of the side products can be formed from CAs with primary amine during the derivatization reaction under un-optimized conditions. We have tested various chemical derivatization techniques in an attempt to find an optimum derivatization method that will reduce side product formation, enable to separate several catecholamine derivatives in GC chromatogram, and obtain significant improvement of detection sensitivity in GC/MS analysis. Whereas several derivatization techniques such as trimethylsilylation (TMS), trifluoroacylation (TFA), and two step derivatization methods were active, selective derivatization to form O-TMS, N-heptafluorobutylacyl (HFBA) derivative using N-methyl-N-(trimethylsilyl)-trifluoroacetamide (MSTFA) and N-methyl-bis(heptafluorobutyramide) (MBHFBA) reagents was found to be the most effective method. Moreover, this derivative formed by selective derivatization could provide sufficient sensitivity and peak separation as well as produce higher mass ion as base peak to use selected ion in SIM mode. Calibration curves based on the use of an isotopically labeled internal standard show good linearity over the range assayed, 1 ~ 5000 ng/mL, with correlation coefficients of > 0.996. The detection limits of the method ranged from 0.2 to 5.0 ppb for the different CAs studied. The developed method will be applied to the analysis of various CAs in biological sample, combined with appropriate sample pretreatment.

Purity Assessment of Organic Reference Materials with a Mass Balance Method: A Case Study of Endosulfan-II

  • Kim, Seung-Hyun;Lee, Joonhee;Ahn, Seonghee;Song, Young-Sin;Kim, Dong-Kyum;Kim, Byungjoo
    • Bulletin of the Korean Chemical Society
    • /
    • v.34 no.2
    • /
    • pp.531-538
    • /
    • 2013
  • A mass balance method established in this laboratory was applied to determine the purity of an endosulfan-II pure substance. Gas chromatography-flame ionization detector (GC-FID) was used to measure organic impurities. Total of 10 structurally related organic impurities were detected by GC-FID in the material. Water content was determined to be 0.187% by Karl-Fischer (K-F) coulometry with an oven-drying method. Non-volatile residual impurities was not detected by Thermal gravimetric analysis (TGA) within the detection limit of 0.04% (0.7 ${\mu}g$ in absolute amount). Residual solvents within the substance were determined to be 0.007% in the Endosulfan-II pure substance by running GC-FID after dissolving it with two solvents. The purity of the endosulfan-II was finally assigned to be ($99.17{\pm}0.14$)%. Details of the mass balance method including interpretation and evaluating uncertainties of results from each individual methods and the finally assayed purity were also described.

Examination of GC-TD sensitivity for reduced sulfur compounds in relation to temporal stability and reproducibility (환원 황화합물의 열탈착 분석기법에 대한 감도의 경시변화 및 재현성에 대한 연구)

  • Hong, One-Feel;Kim, Ki-Hyun
    • Analytical Science and Technology
    • /
    • v.23 no.1
    • /
    • pp.24-35
    • /
    • 2010
  • To learn more about the calibration properties of reduced sulfur compounds (RSCs) by the combination of gas chromatography(GC)-pulsed flame photometric detector (PFPD) and thermal desorption method, a series of calibration experiments were conducted on the basis of both internal and external calibration approaches. For these experiments, gaseous standards of 4 RSCs ($H_2S$, $CH_3SH$, DMS, and DMDS) were prepared at two different concentration levels of both low (10, 20, 50,and 100 ppb) and high ranges (100, 200, 500, and 1000 ppb) along with $CS_2$ as an internal standard. First, the external calibration results were compared between fixed standard volume (FSV) and fixed standard concentration (FSC) method. Secondly, FSV-based calibration results were compared between external and internal calibration results. As FSV method suffers from sensitivity variations less significantly than FSC, the former is recommended to maintain the consistency in GC-TD sensitivity for RSC analysis. In addition, when the calibration data were examined in terms of RSE between external and internal calibration data, the results were not consistent enough to show improvements in internal method. Hence, diverse efforts are desirable to optimize the reproducibility in terms of GC-TD sensitivity for RSC analysis.

Improvement of Analysis Methods for Fatty Acids in Infant Formula by Gas Chromatography Flame-Ionization Detector (GC-FID를 이용한 조제유류 중 지방산 분석법 개선 연구)

  • Hwang, Keum Hee;Choi, Won Hee;Hu, Soo Jung;Lee, Hye young;Hwang, Kyung Mi
    • Journal of Food Hygiene and Safety
    • /
    • v.36 no.1
    • /
    • pp.34-41
    • /
    • 2021
  • The purpose of this research is to improve analysis methods of determining the contents of fatty acids in infant formulas and follow-up formulas. A gas chromatography (GC) method was performed on a GC system coupled to flame ionization detector, with a fused silica capillary column (SP2560, 100 m×0.25 mm, 0.20 ㎛). The method was validated using standard reference material (SRM, NIST 1849a). Performance parameters for method validation such as specificity, linearity, limits of detection (LOD) and quantification (LOQ), accuracy and precision were examined. The linearity of standard solution with correlation coefficient was higher than 0.999 in the range of 0.1-5 mg/mL. The LOD and LOQ were 0.01-0.06 mg/mL and 0.03-0.2 mg/mL, respectively. The recovery using standard reference material was confirmed and the precision was found to be between 0.8% and 2.9% relative standard deviation (RSD). Optimized methods were applied in sample analysis to verify the reliability. All the tested products had acceptable contents of fatty acids compared with component specification for nutrition labeling. The result of this research will provide efficient experimental information and strengthen the management of nutrients in infant formula and follow-up formula.

Volatile Flavor Components in Chinese Quince Fruits, Chaenomeles sinensis koehne (모과의 휘발성 Flavor 성분에 관한 연구)

  • Chung, Tae-Young;Cho, Dae-Sun;Song, Jae-Chul
    • Korean Journal of Food Science and Technology
    • /
    • v.20 no.2
    • /
    • pp.176-187
    • /
    • 1988
  • Volatile flavor components in the Chinese quince fruits were trapped by simultaneous steam distillation-extraction method, and these were fractionated into the neutral, the basic, the phenolic and the acidic fraction. In the identification of carboxylic acids, the acidic fraction was methylated with diazomethane. Volatile flavor components in these fractions were analyzed by the high-resolution GC and GC-MS equipped with a fused silica capillary column. The total of one hundred and forty-five compounds from the steam volatile concentrate of the Chinese quince fruits were identified: they were 3 aliphatic hydrocarbons, 1 cyclic hydrocarbon, 4 aromatic hydrocarbons, 9 terpene hydrocarbons, 17 alcohols, 3 terpene alcohols, 6 phenols, 21 aldehydes, 7 ketones, 28 esters, 27 acids, 3 furans, 2 thiazoles, 2 acetals, 3 lactones and 9 miscellaneous ones. The greater part of the components except for carboxylic acids were identified from the neutral fraction. The neutral fraction gave a much higher yield than others and was assumed to be indispensable for the reproduction of the aroma of the Chinese quince fruits in a sensory evaluation. According to the results of the GC-sniff evaluation, 1-hexanal, cis-3-hexenal, trans-2-hexenal, 2-methyl-2-hepten-6-one, 1-hexanol, cis-3-hexenol, trans, trans-2, 4-hexadienal and trans-2-hexenol were considered to be the key compounds of grassy odor. On the other hand, esters seemed to be the main constituents of a fruity aroma in the Chinese quince fruits.

  • PDF

Development of analysis method for high purity nitrogen using GC-FID/Methanizer (GC-FID/Methanizer를 이용한 고순도 질소의 순도분석법 개발)

  • Jei, You;Jin Bok, Lee;Jin Seog, Kim;Woonjung, Kim;Kiryong, Hong
    • Analytical Science and Technology
    • /
    • v.35 no.6
    • /
    • pp.249-255
    • /
    • 2022
  • In this study, a new method for the analysis of high-purity nitrogen was developed. A gas chromatography-flame ionization detector (GC-FID) was used for purity analysis. Certified reference materials (CRMs) at a level of 3 µmol/mol of carbon monoxide (CO), carbon dioxide (CO2), and methane (CH4), which may exist in high-purity nitrogen, were prepared using the gravimetric method, and these CRMs were used for purity analysis. In this new method, ultra-high-purity and high-purity nitrogen were used as carrier gases. The impurities in high-purity nitrogen were quantitatively analyzed by comparing the differences in the area values of the GC chromatograms of the prepared CRMs. We purchased liquid nitrogen and three bottles of nitrogen gas, which were produced by three different manufacturers, using high-purity nitrogen. Furthermore, to validate the developed purity analysis method, the fraction of impurities in high-purity nitrogen was compared with the results of the typical purity analysis method. The comparison results were consistent within the expanded uncertainties (k = 2).

Association of the PSCA rs2294008 C>T Polymorphism with Gastric Cancer Risk: Evidence from a Meta-Analysis

  • Zhang, Qing-Hui;Yao, Yong-Liang;Gu, Tao;Gu, Jin-Hua;Chen, Ling;Liu, Yun
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2867-2871
    • /
    • 2012
  • Background: Multiple studies have reported associations between the PSCA rs2294008 C > T polymorphism and GC, but susceptibility has proven inconsistent. Therefore, we estimates the relationship between the rs2294008 C > T polymorphism and GC by meta-analysis. Methods: PubMed, Embase and Web of Science databases were searched and nine independent case-control studies were included in this meta-analysis. Crude ORs with 95% CIs were extracted according to the Mantal-Haenszel method and pooled to assess the strength of the association. Results: We observed that the PSCA rs2294008 C > T polymorphism was significantly correlated with GC risk when all studies were pooled into the meta-analysis. Further subgroup analysis showed the polymorphism to be linked with diffuse and noncardia GC in the allele contrast model, homozygote codominant model, dominant model, and recessive model. However, no connection was apparent for intestinal and cardia GC. In the stratified analysis by ethnicity, significant associations were observed in Asians for the recessive model. Interestingly, the relationship was particularly significant in the Chinese population. Conclusions: Our findings suggest that the PSCA rs2294008 C > T polymorphism is a risk factor for GC, especially in diffuse and noncardia GC and in Chinese.

Analysis of Multiple Pesticide Residues in Raw Materials Used in Dietary Supplements by GC/ECD and NPD (GC/ECD와 NPD를 이용한 건강기능식품 주요 원료 중 다성분 잔류농약 분석)

  • Park, Sun-Young;Oh, Sang-Suk
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.6
    • /
    • pp.863-871
    • /
    • 2004
  • Analyses of residual pesticides in raw materials used for dietary supplements were performed using multi-ingredients simultaneous analysis method. Pesticides such as BHC, chlorpyrifos, and quintozene were detected in 12 domestic and 7 imported samples, suggesting need for monitoring pesticides in domestic and imported raw materials and establishing residual limit of each pesticide.

Gas Chromatographic Analysis of TDI, MDI and HDI Using 2-Chlorobenzyl Alcohol and 2,4-Dichlorobenzyl Alcohol Derivatives (2-클로로벤질 알코올 및 2,4-디클로로벤질 알코올 유도체를 이용한 TDI, MDI 및 HDI의 가스크로마토그래피 분석)

  • Yun, Ju-Song;Park, Jun-Ho;Lee, Kang-Myoung;Choi, Hong-Soon;Cho, Young-Bong;Koh, Sang-Baek;Cha, Bong-Suk
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.16 no.3
    • /
    • pp.222-232
    • /
    • 2006
  • Objectives: The objective of this study was to propose the total isocyanate analytical method which involves derivation of 2,4-toluene diisocyanate(2,4-TDI), 2,6-toluene diisocyanate(2,6-TDI), 4,4'-methylenediphenyl diisocyanate(4,4'-MDI) and 1,6-hexamethylene diisocyanate(1,6-HDI) using 2-chlorobenzyl alcohol(2-CBA) or 2,4-dichlorobenzyl alcohol(2,4-DCBA), and analyzing of hydrolysate of the synthesized urethane with the gas chromatography(GC)/flame ionization detector(FID), GC/pulsed discharge ionization detector-electron capture detector(PD-ECD) and GC/mass selective detector(MSD). Methods: Urethanes were synthesized by reacting 2,4-TDI, 2,6-TDI, 4,4'-MDI and 1,6-HDI to 2-CBA or 2,4-DCBA. Urethanes was verified by TLC, HPLC/UVD and GC/MSD. For field application, the most suitable condition that 2-CBA coated in glass fiber filter removed completely and urethanes were not removed was searched. 2-CBA generated from hydrolysis of urethanes according to hydrolysis conditions. Diisocyanates were collected on field air and analyzed. Results: Urethanes which were white and solid phase synthesized by reacting 2,4-TDI, 2,6-TDI, 4,4'-MDI, 1,6-HDI and 2-CBA or 2,4-DCBA. And urethanes were verified by TLC, HPLC/UVD and GC/MSD. The most suitable conditions to remove 2-CBA coated in glass fiber filter were $87^{\circ}C$ and 20 mmHg and urethanes were not removed under same condition. Hydrolysis yields of urethanes were 99 % to 111 %. 2-CBA, the hydrolysate of urethanes was analyzed by GC/FID, GC/PD-ECD and GC/MSD. Conclusions: Simultaneous analysis of 2,4-TDI, 2,6-TDI, 4,4'-MDI and 1,6-HDI deriving with 2-CBA and 2,4-DCBA, along with a total isocyanate analysis, was feasible with GC/FID, GC/PD-ECD and GC/MSD. This result will be a guide of further study on total isocyanate analysis.