• 제목/요약/키워드: GC column

검색결과 440건 처리시간 0.025초

가스 크로마토그래피 캐필러리 컬럼 설치 가이드 (GC Capillary Column Installation)

  • Matt James;Kirsty Ford
    • FOCUS: LIFE SCIENCE
    • /
    • 제1호
    • /
    • pp.2.1-2.6
    • /
    • 2024
  • This article provides detailed instructions for the correct installation, maintenance, and troubleshooting of capillary gas chromatography (GC) columns. It emphasizes the importance of proper installation to ensure optimal performance and longevity of the column. The document covers various aspects such as column trimming, installation, conditioning, testing, storage, and ferrule selection. The installation process involves ensuring that the heated zones of the GC are cool before placing the column cage in the column oven. It is essential to avoid sharp bends or stress on the capillary column during installation and to connect the front end of the column into the GC inlet at the recommended insertion distance. The document also provides guidance on trimming the column, including the use of a ceramic wafer or capillary column cutter to achieve a clean, burr-free cut. For previously used columns, it recommends removing any capillary caps, positioning the nut and ferrule, and trimming 1-2 cm from the column. After installation, the column should be purged with carrier gas to remove any oxygen and avoid oxidizing the column. Conditioning the column involves ramping to the upper isothermal temperature limit and maintaining this temperature for a specified duration. It is crucial to maintain carrier gas flow during conditioning and not exceed the upper temperature limit of the column to avoid phase damage. The document also discusses testing column performance using a suitable method and performing a test injection to assess performance. It provides recommendations for column storage, including flame-sealing the capillary ends or using retention gaps for long-term storage. Additionally, it emphasizes the importance of routine maintenance and replacement of GC consumables to extend the column's lifetime. Ferrule selection is another important aspect covered in the article, with a variety of ferrule materials available for different applications. The characteristics of common ferrule options are presented in a table, including temperature limits, reusability, and suitability for specific detector types.

  • PDF

유기인제 농약 분석 방법 (Multi-Pesticide Residue Method) 개발에 관한 연구 (Study on the Development of Analytical Method (Multi-Pesticide Residue Method) for Organophosphate Pesticides)

  • 이봉헌;김우성
    • 한국환경과학회지
    • /
    • 제6권2호
    • /
    • pp.183-187
    • /
    • 1997
  • 유기인제 농약을 70% acetone으로 추출한 다음 dlchloromethane 층으로 옮겨 추출물을 florisil로 충진된 open-column에서 chromatography를 행하였다. 마지막 추출물을 nitrogen-phosphorus detector(GC/NPD)을 가진 GC로 분석하였다. Narrow-bore capillary GC(Ultra-2)에 대해 18 가지의 유기인제 농약의 회수율이 88.7%에서 100.0%에 달하였다. 본 분석 방법의 최소 검출 준위는 0.019 - 0.035 mg/kg 이었으며 sample throughput(추출, open-column chro-matography 및 GC 분석)도 상당히 개선되었다.(sample당 8시간)

  • PDF

Gardenia Absolute Oil을 구성하고 있는 휘발성 성분의 분석 (Analysis of Volatile Compounds in the Gardenia Absoulute Oil)

  • 하창규;양해주;윤석신
    • 대한화장품학회지
    • /
    • 제19권1호
    • /
    • pp.31-56
    • /
    • 1993
  • GC와 GC-MSD와 관능시험을 이용하여 Gardinia Jasmoniodes Ellis로 부터 제조한 Gardinia Absolute Oil의 특징적인 방향성분을 확인하였다. GC 분석 방법은 극성 비극성의 column인 Carbowax 20M과 SPB-1을 동시에 장착한 Double Column System을 이용하였으며 GC Workstation에 의한 자동적인 Retention Indexs Match System을 적용하여 분석된 data를 확인하였다. 시험적 판단 성분 9개를 포함하여 전부 51개의 성분을 확인하였다. 주요성분으로 Linalool, 여러 형태의 Farnesene, Jasmin lactone, Gamma undecalactone 그리고 Cis-3-hexene 유도체들이 있다.

  • PDF

식초의 에탄올 및 초산 함량의 동시분석 (Simultaneous Gas Chromatographic Analysis of Ethanol and Acetic Acid in Vinegar)

  • 윤희남
    • 한국식품과학회지
    • /
    • 제30권6호
    • /
    • pp.1247-1251
    • /
    • 1998
  • 식초의 에탄올과 초산을 동시에 분석하고자 packed column으로 gas chromatographic analysis을 모색하였다. Tenax-GC를 충진물로 사용하여 $2\;m{\times}2\;mm$의 stainless steel column을 제조하고 식초를 여과하여 column에 직접 주입한 결과 내부 표준 물질로 사용한 isopropyl alcohol과 에탄올, 초산이 20분 이내에서 완전히 분리되었으며 정확도가 매우 높은 것으로(P<0.05)나타났다. 19종의 식초를 이용하여 적정방법으로 산도를, packed column GSC로 에탄올과 초산을, HPLC로 초산을, capillary column GLC로 에탄올과 초산을 각각 분석하여 분석치들을 상호 비교하였다.

  • PDF

가스 크로마토그래픽 컬럼의 유동특성에 대한 수치적 연구 (A NUMERICAL STUDY ON THE FLOW CHARACTERISTICS OF GAS CHROMATOGRAPHIC COLUMN)

  • 김태안;김윤제
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2005년도 추계 학술대회논문집
    • /
    • pp.21-26
    • /
    • 2005
  • Gas Chromatography (GC) is a wisely technique used for the separation and analysis of liquid and gas sample. Separation of the sample vapors is achieved via their differential migration through a capillary column with an insert carrier gas. The identity and quantity of each vapor in the mixer can be determined from its retention time in the column and a particular property of the gas, such as thermal conductivity, which can be related to the concentration of sample vapor in the carrier gas. Therefore, the flow characteristics in the spiral gas chromatographic column are numerically investigated in this study. Especially, different pressure drop between the front and the rear of GC column with various flow rates is estimated the governing equations are derived from making using of three-dimensional Naver-Stokes equation with incompressible and laminar model due to the nature of low Reynolds number flow. Using a commercial code, FLUENT, the pressure and flow fields in GC column are calculated with various flow rates. The characteristics of thermal cycling which is one of the most important factors affecting the column efficiency and analysis time is also estimated. Furthermore, numerical analyses are also carried out by using commercial code, ANSYS, with various values of power, which is applied to the heating element located at lower GC column.

  • PDF

열탈착-저온농축-GC/FID/FPD에 의한 도시 생활폐기물 매립장에서 방출되는 휘발성 유기화합물의 측정에 관한 연구 (Determination of Volatile Organic Compounds emitted from Municipal Solid Waste Landfill Site by Thermal Desorption-Cryofocusing-GC/FID/FPD)

  • 김만구;정영림;서영민;남성현;권영진
    • 분석과학
    • /
    • 제14권3호
    • /
    • pp.274-285
    • /
    • 2001
  • 본 연구는 ppb와 ppt 정도의 농도 수준으로 존재하고 있는 대기 중 휘발성 유기화합물을 분석하기 위해 열탈착-저온농축-GC/FID/FPD를 개발하였다. 그리고 고체흡착제가 충진된 흡착관과 자체 제작한 휴대용 가스채취기를 사용하여 강원도 춘천지역에 위치한 근화동과 혈동리 생활폐기물 매립장에서 배출되는 VOCs를 채취하였다. 저온농축방법으로는 분석컬럼을 직접 저온 농축하는 on-column 저온 농축장치와 0.8mm loop를 이용한 저온농축장치를 서로 비교 검토해 보았다. On-column 저온농축법은 loop에 비해 분리능은 좋으나 흡착관에 채취한 시료를 저온농축할 때 요구되는 50 psi의 높은 탈착압력으로 인해 흡착관의 SwageLok fitting이 마모되어 가스가 새는 문제점이 발생하였다. 이에 반해 탈착압력을 낮추고 탈착유량을 늘리기 위해 설계한 loop 경우에는 탈착압력이 0.4 psi로 on-column에 비해 매우 낮아 가스가 새는 것을 방지할 수 있었다. 열탈착-저온농축-GC/FID/FPD로 분석한 근화동과 혈동리 생활폐기물 매립장에서 검출된 물질로는 toluene, xylene, ethylbenzene등 탄화수소류와 악취물인 styrene, limonene, dimethyl disulfide 등이 검출되었다. 그리고 매립지에서 방출되는 VOCs는 매립되는 폐기물의 조성과 매립기간에 따라 다르게 나타났다. 검출된 화합물은 저온농축-GC/MS를 이용하여 확인하였다.

  • PDF

The Analysis of VOCs by GC/MS with Whole Column Coldtrapping on a Fused Silica Capillary Column in Indoor Environment

  • Dai, Shugui;Zhang, Lin;Bai, Zhipeng
    • 분석과학
    • /
    • 제8권4호
    • /
    • pp.829-834
    • /
    • 1995
  • Whole column coldtrapping(WCC) on a fused silica capillary (FSCC)combined with GC/MS analysis was evaluated for use in the investigation of volatile organic compounds(VOCs) in indoor air. Research had indicated that a temperature of $-80^{\circ}C$ is optimal for WCC. Samples were analyzed on a $50m{\times}0.2mm$ cross-linked 5% phenylmethylsilicone fused silica column. Liquid nitrogen was used as the coolant for the peak resolution significantly. The analysis can be performed quickly and conveniently. More than 112 of VOCs were determined in the samples from three typical indoor environment including: (1) a room which had just been decorated involving building materials and paints; (2)a kitchen used for Chinese cooking, and (3) a room had tobacco smoke. The method is could be readily applied to rapid sample screening for VOCs contamination surveys or initial investigations with its valid and simple sampling and analytical technique.

  • PDF

GC/MS에 의한 오미자 Lignan성분의 동정 (Identification of Lignan Compounds in Fruits of Schisandra chinensis BAILLON by Gas Chromatography/Mass Spectrometry)

  • 손현주;복진영
    • Applied Biological Chemistry
    • /
    • 제32권4호
    • /
    • pp.344-349
    • /
    • 1989
  • GC/MS를 이용하여 오미자의 chloroform-methanol 추출물로부터 11종의 lignan 성분을 동정하였다. GC column은 SPB-1 fused silica capillary $(0.25mm\;ID{\times}30m,\;Supelco)$를 사용하였고 column oven의 온도는 $200^{\circ}C$부터 $300^{\circ}C$까지 분당 $4^{\circ}C$씩 승온하였으며 MS의 ionization voltage는 70eV (El mode)이었다. 동정된 lignan 성분은 gomisin J, deoxyschizandrin, gomisin N, schizandrin, wuweizisu C, gomisin A, angeloylgomisin H, tigloylgomisin H, angeloylgomisin Q, gomisin B 및 benzoylgomisin H이었으며, GC chromatogram 상에서 이들 화합물의 분리상태는 양호하였다.

  • PDF

유기농약 분석을 위한 Multi-Pesticide Residue Method (Multi-Pesticide Residue Method for Organopesticide Analysis)

  • 김우성;이봉헌
    • 한국환경과학회지
    • /
    • 제6권4호
    • /
    • pp.385-389
    • /
    • 1997
  • 농약 잔류물을 70% acetone으로 추출한 다음 dichloromethane 층으로 옮겨 추출물을 florisil과 alumina-N으로 충진시켜 column chromatography를 행하였다. 마지막 추출물을 electron-capture detector(GC/ECD)와 nitrogen-phosphorus detector(GC/NPD)를 가진 GC로 분석하였다. 분석 결과 17 가지의 유기염소계 농약과 15 가지의 유기인계 농약의 회수율이 각각 60.8 에서 84.9%와 70.5에서 100.0%의 범위이었으며(phosmet와 azlnphos-methyl은 제외) 본 분석 방법의 최소 검출 준위도 낮았다(0.021-0.058mg/kg).

  • PDF