• Title/Summary/Keyword: GC and GC-MS method

Search Result 828, Processing Time 0.028 seconds

Determination of Additives Content in Aviation Turbine Fuel Using Multi-dimensional GC-MS (Multi-dimensional GC-MS를 이용한 항공터빈유의 첨가제 분석)

  • Youn, Ju Min;Jang, Yoon Mi;Yim, Eui Soon;Kim, Seong Lyong;Kang, Yong
    • Journal of the Korean Applied Science and Technology
    • /
    • v.35 no.4
    • /
    • pp.1260-1268
    • /
    • 2018
  • To improve fuel performance and specific characteristics of long storage and moving through fuel systems additives should be added in kerosene type aviation turbine fuel (AVTUR) such as antioxidant, fuel system icing inhibitor (FSII), electric conductivity improvers and so on. The dosage of additives has to be analyzed qualitatively and quantitatively due to inspect the quality of abnormal fuel and distinguish other petroleum products. Multi-dimensional GC-MS (MDGC-MS) with Deans switching technique are applied the determination of antioxidant and FSII, which are added with AVTUR containing complex mixture of hydrocarbons. Antioxidant and FSII in the range of 2.5-20 mg/L was quantitatively and qualitatively analyzed using MDGC-MS and the detection limit was about twice as low as that of the 1-dimensional GC-MS results. The method in this study has been higher peak resolution compared with GC-MS and could be simultaneously analyzed different two additives without sample pre-treatment.

The Study on the Composition of Rehmanniae Radix Extracts by Supercritical Carbon Dioxide Extraction and by Hydrodistillation Extraction (생지황(生地黃) 증류 추출 약침액과 초임계 유체 추출물의 성분 연구(硏究))

  • Heo, Jong-Won;Yook, Tae-Han
    • Journal of Acupuncture Research
    • /
    • v.28 no.2
    • /
    • pp.89-95
    • /
    • 2011
  • Objectives : The purpose of this study was to investigate the composition of Rehmannia glutinosa's essential oils with Rehmanniae Radix herbal acupuncture Methods : I obtained the essential oils of Rehmannia Radix by hydrodistillation extraction method and supercritical fluid extraction(SFE) method, and then I analyzed those by GC/MS(gas chromatography/mass spectrum). Results : 1. With GC(gas chromatography) and GC/MS(gas chromatography/mass spectrum) analysis. I identified 9 compounds in the Rehmanniae Radix's essential oil obtained through the SFE method. The main compounds were as follows : Hexachloroethane(2.24%), N-Butyl-benzenesulfonamide(2.05%), hexadecanoic acid(1.93%), hexadecanoic acid, ethyl ester(3.49%), 9,12-Octadecadienoic acid(z,z)(2.70%), (9E)-9-Octadecenoic acid(6.14%), ethyl linoleate(4.43%), ethyl oleate(5.80%). 2. I failed to get Rehmanniae Radix's essential oil obtained through the hydrodistillation method. 3. With GC(gas chromatography) and GC/MS(gas chromatography/mass spectrum) analysis. I identified 4 compounds in the Rehmanniae Radix's essential oil obtained through the hydrodistillation method. The main compounds were as follows : Ethylbis(trimethylsilyl)amine(1.04%), 2-(Trimethylsiloxy)benzoic methyl ester(2.65%), Hexadecanoic acid trimethylsilyl ester(12.61%), octadecanoic acid, trimethylsilyl ester(6.28%). Conclusions : The substances by hydrodistillation method may not perfectly match with the substances by supercritical fluid extraction(SFE) method in essential oils extracted form Rehmanniae Radix. But, the main substances was assumed Hexadecanoic acid and octadecanoic acid.

The Study on Analysis Method and Performance Evaluation of Portable GC/MS (휴대용 GC/MS 성능검사 및 분석방법 연구)

  • Park, Yuonshin;Noh, Hyeran;Yang, Heeseon;Seok, Gwanseol
    • Journal of the Society of Disaster Information
    • /
    • v.9 no.3
    • /
    • pp.249-258
    • /
    • 2013
  • Recieved Mar. 06, 2013 Revised Mar. 29, 2013 Accepted Sep. 11, 2013In this study, we evaluated the method performance and the optimum sample injection method of the portable GC/MS(HAPSITE) which were designed to operate on scene of chemical accidents. Chemicals used for performance test were vinyl chloride(VC), methyl chloride(MC), benzene(Bz), toluene(Tol). CRM(Certified Reference Material) Manufactured by KRISS(Korea Research Institute of Standards and Science) was used as the standard gas. The results showed that 1) Among three sample injection methods(Cylinder, Silico canister, and Bag), bag was identified as the most appropriate sample injection method. Bag material and capacity did not significantly affect the results. The most ideal reproducibility occurred at the 2-minute point of the purge time in the loop and tenax methods. 2) Performance evaluation of HAPSITE was conducted. Evaluation items were reproducibility, linearity, method detection limit, etc. Tenax concentration method was appropriate for larger molecules and Carbopack concentration method was suitable for smaller molecules.

Development of Analytical Method for Fenoxanil in Agricultural Products Using GC-NPD and GC/MS (농산물 중 Fenoxanil 잔류성 시험법 개발)

  • Kim, Gyeong-Ha;Ahn, Kyung-Geun;Kim, Gi-Ppeum;Hwang, Young-Sun;Lee, Young Deuk;Choung, Myoung-Gun
    • The Korean Journal of Pesticide Science
    • /
    • v.19 no.4
    • /
    • pp.345-353
    • /
    • 2015
  • The aim of this study is to develop residue analysis method for fenoxanil, a MBI (melanin biosynthesis inhibitor) propionamide fungicide, had mainly been used to control rice blast, and disease of other crops, fruits, and vegetables by using GLC/NPD and GC/MS. Extraction with acetone and partition with n-hexane/dichloromethane (80/20, v/v) were performed from hulled rice, soybean, Kimchi cabbage, green pepper, and apple, then column clean-up with florisil was applied. Mean recoveries were 82.2%-109.1% with less than 7.2% of coefficients of variation and limit of quantitation was set at the concentration of 0.04 mg/kg from the five agricultural products through the determination by GLC/NPD equipped with DB-5 capillary column and single laboratory validation. As a confirmatory method, GC/MS selected ion monitoring (SIM) was set from m/z 125.0, 188.9, and 293.0. Developed method is expected to apply the single residue analysis of fenoxanil in agricultural products.

GC/MS Analysis of Saccharin in Foods (GC/MS를 이용한 식품중 Saccharin의 분석에 관한 연구)

  • 노동석;김승기;이정애;정현숙;유보경;박종세
    • Journal of Food Hygiene and Safety
    • /
    • v.10 no.4
    • /
    • pp.239-247
    • /
    • 1995
  • Analytical method for saccharin in foods was developed using gas chromatography/mass spectrometry(GC/MS). Methylation with diazomethane, acetylation with MBTFA, and silylation with MSTFA and MTBSTFA were compared. Methylation of saccharin produced N-methylated saccharin as the major product and O-methylated saccharin as the minor one. Silylation of saccharin with MSTFA and MTBSTFA reasulted in the formation of the correponding O-silylated products, respectively. The derivatization of saccharin was optimized with MSTFA. The ions at m/z 240, 255, and 166 were monitored to characterize saccharin.

  • PDF

Determination of fungicides in wines by solid-phase extraction and gas chromatography with mass selective detection (고체상 추출법과 GC/MS를 이용한 포도주 중의 fungicides 정량)

  • Park, Gyo-Beom;Lee, Sueg-Geun
    • Analytical Science and Technology
    • /
    • v.16 no.6
    • /
    • pp.438-442
    • /
    • 2003
  • The fungicides, used for grape growth and remained in the wine products from domestic and foreign countries such as vinclozolin, dichlofluanid, penconazole, procymidone were quantitatively analyzed after solid-phase extraction using a GC/MS-SIM method. The results obtained were as follows: for all the samples, the content of procymidone was in the range from 2.2 to $76.1{\mu}g/L$, recoveries 81.3-93.1 %, and standard deviation 1.4-3.4 %.

Validation of an analytical method for cyanide determination in blood, urine, lung, and skin tissues of rats using gas chromatography mass spectrometry (GC-MS)

  • Shin, Min-Chul;Kwon, Young Sang;Kim, Jong-Hwan;Hwang, Kyunghwa;Seo, Jong-Su
    • Analytical Science and Technology
    • /
    • v.32 no.3
    • /
    • pp.88-95
    • /
    • 2019
  • This study was conducted to establish the analytical method for the determination of cyanide in blood, urine, lung and skin tissues in rats. In order to detect or quantify the sodium cyanide in above biological matrixes, it was derivatized to Pentafluorobenzyl cyanide (PFB-CN) using pentafluorobenzyl bromide (PFB-Br) and then reaction substance was analyzed using gas chromatography mass spectrometer (GC/MS)-SIM (selected ion monitoring) mode. The analytical method for cyanide determination was validated with respect to parameters such as selectivity, system suitability, linearity, accuracy and precision. No interference peak was observed for the determination of cyanide in blank samples, zero samples and lower limit of quantification (LLOQ) samples. The lowest limit detection (LOD) for cyanide was $10{\mu}M$. The linear dynamic range was from 10 to $200{\mu}M$ for cyanide with correlation coefficients higher than 0.99. For quality control samples at four different concentrations including LLOQ that were analyzed in quintuplicate, on six separate occasions, the accuracy and precision range from -14.1 % to 14.5% and 2.7 % to 18.3 %, respectively. The GC/MS-based method of analysis established in this study could be applied to the toxicokinetic study of cyanide on biological matrix substrates such as blood, urine, lung and skin tissues.

Determination of agrochemical residues in tobacco using matrix solid-phase dispersion and GC/MS

  • Lee, Jeong-Min;Min, Hye-Jeong;Park, Jin-Won;Lee, Moon-Young;Jang, Gi-Chul
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.36 no.1
    • /
    • pp.12-19
    • /
    • 2014
  • A matrix solid-phase dispersion (MSPD) method was developed for extracting and cleaning-up the selected agrochemicals in tobacco using gas chromatography-mass spectrometry with selected ion monitoring (GC/MS-SIM). Different parameters of the method were investigated and optimized, such as the type of solid-phase (alumina, $C_{18}$ and Florisil) and eluent (acetone, acetonitrile, ethylacetate and n-hexane). The best results were obtained using 0.5 g of tobacco sample, 1.0 g of $C_{18}$ as dispersant sorbent, 1.0 g of Florisil as clean-up sorbent and acetonitile saturated with n-hexane as eluting solvent. The method was validated using tobacco samples fortified with agrochemicals at their different concentration levels. This method gave good linearity for the selected agrochemicals of ranging from $0.01{\mu}g/mL$ to $0.1{\mu}g/mL$. Recoveries of the selected agrochemicals in tobacco were more than 80 % and reproducibilities were found to be better than 10 % RSD. Those results suggested that the analytical procedure including MSPD method in combining with GC/MS could be applicable to the rapid determination often the selected agrochemicals in tobacco.

Comparison of TLC and GC-MS Method in the Analysis of Dye Extracted from Madder Plant (꼭두서니 추출염료에 대한 TLC와 GC-MS 분석법의 비교 연구)

  • ;S. Kay Obendorf
    • The Research Journal of the Costume Culture
    • /
    • v.12 no.4
    • /
    • pp.579-590
    • /
    • 2004
  • This research was aimed to investigate and compare the effectiveness of TLC and GC-MS methods in the analysis of chromophoric substances extracted from madder plant. Alizarin and purpurin 0.3% solution were used as comparative standards; madder extraction was prepared by heating the solution of powdered madder at 80℃, pH 1.5, for 90 min. Best elution solvent for TLC in silica gel plate was toluene:ethyl acetate=9:1, which resulted in red and yellow spots from madder extraction each of which showed R/sub f/ values 0.32-0.43 and 0.07-0.11. Although the red spot in particular exhibited similar characteristics as standard purpurin in color, shape, and R/sub f/ values, the result was inconsistent throughout different TLC trials. GC-MS analysis showed only small amount of alizarin and no purpurin in the madder extraction. Other chromophoric substance such as 2-furancarboxaldehyde, 5-(hydroxymethyl)-, anthralin, and danthron were also detected in small amounts. The result indicated that TLC was less sensitive to detecting and identifying the natural dyestuff which is generally constituted with a number of similar but chemically different chromophoric substances.

  • PDF

Determination of the PDE-5 Inhibitors and Their Analogues by GC-MS and TMS Derivatization

  • Pyo, Jae-Sung;Lee, Hee-Sang;Park, Yu-Jin;Jo, Ji-Yeong;Park, Yong-Hoon;Choe, Sang-Gil;Lee, Mi-Young;Lee, Jae-Sin
    • Mass Spectrometry Letters
    • /
    • v.3 no.1
    • /
    • pp.15-17
    • /
    • 2012
  • Eighteen of the PDE-5 inhibitors and their analogues were analyzed using GC-EI-MS. Fourteen of them could be identified by simple GC-MS method without derivatization, but hydroxyhongdenafil, hydroxyvardenafil, xanthoanthrafil and mirodenafil could not be identified without derivatization for the high polarity due to the presence of hydroxyl groups. N,O-bis(trimethylsilyl) trifluoroacetamide (BSTFA) and N-methyl-N-(tert-butyldimethylsilyl)trifluoroacetamide (MTBSTFA), widely used trimethylsilyl (TMS) derivatizing reagents, were used to improve the sensitivity of the hydroxylated analogues. And the analytes could be identified by GC-MS after the derivatization.