• Title/Summary/Keyword: GAS Boiler

Search Result 362, Processing Time 0.026 seconds

A Study on the Identification of Hazardous Factors and Prevention of Accident in Old Boilers (노후보일러 유해인자 발굴 및 사고예방에 관한 연구)

  • Sa, Min-Hyung;Woo, In-Sung
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.4
    • /
    • pp.1-9
    • /
    • 2019
  • Large-scale industrial boilers operating at high temperature and high pressure, have a large amount of water, and a large amount of energy is released at the time of explosion. Currently, most industrial boilers use gas fuel such as LNG and LPG, etc. and fuel exists in the same space as equipment, so there is a high possibility of secondary damage such as fire or explosion in the event of a boiler accident. Both special care and management are required to operate the very dangerous equipment that causes casualty 2.51 per accident. For boilers of a certain size or more, the Korea Energy Agency conducts inspections in accordance with the Energy Usage Rationalization Act, KS, and public notice of the Ministry of Industry, Trade and Resources. In this research, based on the results of the inspection, the hazard factorss are configured, and a questionnaire is conducted to the inspector, the equipment manager, the maintenance person, and the person in charge of the manufacturer. We analyzed the results by using AHP (Analytic Hierarchy Process). As a result of analysis, generally recognized hazard factorss are not good management, measurement failure, specification failure, water leak, leak analysis, but connection, welding, scale, and corrosion, etc. are relatively less important. It is judged that the adverse factors that are recognized to be highly important among all groups and careers are already well managed, but less important and adverse factors should be well managed to ensure that the safe usage of the boiler.

A Study on the Cross Subsidization of Energy Industries in Korea (에너지 산업(産業)의 교차보조(交叉補助)에 관한 연구(硏究))

  • Chung, Hee-Yung;Kang, Hee-Jung
    • Journal of the Korean Institute of Gas
    • /
    • v.10 no.4 s.33
    • /
    • pp.17-22
    • /
    • 2006
  • Both of district heating(DH) system and natural gas(NG) supply system have benefits in clean energy supply and having energy efficiency and savings. The issue of duplicate investment and supply requirement of only for cook occur several conflicts such as destruction of the Beneficiary Pays Principle and Cross Subsidization, etc. Under the circumstance, the purposes of this research are to consider several issues of cross subsidization in NG and DH industries and to present the following alternatives for resolving related problems. First of all, a charging mechanism in the energy cost must be improved so as to maintain the positive relation between cost and benefit. That is, the beneficiary-pay principle must be strictly applied. Secondly, the extended supply of DH through HOB(Heat Only Boiler) must be strictly limited. Finally, we need to improve efficiency for the benefit of market participants.

  • PDF

The Operational Characteristics of CO2 5 ton/day Absorptive Separation Pilot Plant (이산화탄소 5 ton/day 흡수분리 Pilot Plant 운전 특성)

  • O, Min-Gyu;Park, So-Jin;Han, Keun-Hee;Lee, Jong-Seop;Min, Byoung-Moo
    • Korean Chemical Engineering Research
    • /
    • v.50 no.1
    • /
    • pp.128-134
    • /
    • 2012
  • The pilot scale experiments can handle the flue gas up to 1,000 $Nm^3/hr$ for separation of carbon dioxide included in real flue gas at coal-fired power plant. The operational characteristics was analyzed with the main experimental variables such as flue gas flow rate, absorbent circulation rate using chemical absorbents mono-ethanolamine( MEA) and 2-amino-2-methyl-1-propanol(AMP). The more flue gas flow rate decreased in 100 $m^3/hr$ in the MEA 20 wt% experiments, the more carbon dioxide removal efficiency was increased 6.7% on average. Carbon dioxide removal efficiency was increased approximately 2.8% according to raise of the 1,000 kg/hr absorbent circulation rate. It also was more than 90% at $110^{\circ}C$ of re-boiler temperature. Carbon dioxide removal efficiency of the MEA was higher than that of the AMP. In the MEA(20 wt%) experiment, carbon dioxide removal efficiency(85.5%) was 10% higher than result(75.5%) of ASPEN plus simulation.

Computational Fluid Dynamic Analysis for Improving the Efficiency of Desulfurization System for the Wet Flue Gas (습식 배연탈황 시스템의 효율 향상을 위한 전산해석)

  • Hwang, Woo-Hyeon;Lee, Kyung-Ok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.2
    • /
    • pp.161-171
    • /
    • 2014
  • In this paper the flow dynamics of the flue gas equipment in the desulfurization system was numerically analyzed by simulating the problems for the turbulent and combustion flow from Induced Draft Fan(I.D.Fan) outlet to Booster Up Fan(B.U.Fan) inlet using the commercial CFD software of CFD-ACE+ in CFDRC company for Computational Fluid Dynamic Analysis. The guide vane of this section was examined for the minimum pressure loss and the uniform flow dynamic to B.U.Fan with the proper velocity from I.D,Fan exit to B,U,Fan inlet section at the boiler both the maximum continuous rating and the design base. The guide vanes at I,D.Fan outlet and B.U.Fan inlet were removed and modified by numerical simulation of the CFD analysis. The flue gas at the system had the less pressure loss and the uniform flow dynamics of the flow velocity and flow line by comparing with the old design equipment.

Qualitative analysis of some kinds of petroleum (thinner, gasoline, kerosene, and diesel oil) by gas chromatography (기체 크로마토그래피를 이용한 몇 가지 석유류(시너, 휘발유, 등유 및 경유)의 정성분석)

  • Hyun, Joon-Ho;Park, Jong-Heon;Kim, Sang-Soo;Choi, Jong-Moon
    • Analytical Science and Technology
    • /
    • v.19 no.6
    • /
    • pp.512-518
    • /
    • 2006
  • The evidence containing some kind of petroleum at the fire spot was analyzed by gas chromatography to identify a fire's sources. To extract some petroleum from fire evidence, 10.0 mL of n-hexane was added in this solution, and it was shaken for 30 minutes. To identify a kind of petroleum in fire evidence, the prepared n-hexane solution was injected and analyzed in the gas chromatograph. The chromatogram of sample was different from those of thinner and gasoline that have low boiling point, and shown different peak pattern to heating and boiler oils. But it was similar to the chromatogram of diesel oil. After small amount of diesel oil was added to the sample, the area of characteristic peaks was increased more than those of raw sample. From the results, the kind of petroleum in the fire evidence was diesel oil.

A Study on Monitoring of Gas Temperature in Boiler Furnace (보일러 화로내 연소가스 온도분포 구현에 관한 연구)

  • Jang, Seok-Won
    • Journal of Energy Engineering
    • /
    • v.15 no.3 s.47
    • /
    • pp.188-193
    • /
    • 2006
  • This paper intends to present theoretical study and its application result of the way of the temperature distribution embodiment through the production of subdivided nod's temperature from the average, maximum and minimum temperature following acoustic speed measurement with a set of acoustic speed meters at the arbitrary section in the furnace. By measuring the acoustic speed between the speed meters, flue gas temperature field can be determined. Then Subdivided arbitrary grid's temperatures can be infered out of surrounding nod's temperature distribution, and finally the entire grid's temperature distribution will be found. In this article, theoretical background, related system setup. and real application result are examined and discussed.

Development of Automatic Synthesis System for Operating Procedures Using Temporal Logic and Description Logic (시간논리와 표현논리를 이용한 운전절차 자동합성 시스템 개발)

  • Hou Bo Kyeng;Hwang Kyu Suk
    • Journal of the Korean Institute of Gas
    • /
    • v.5 no.1
    • /
    • pp.37-44
    • /
    • 2001
  • OPS(Operating Procedure Synthesis) systems can reduce the time and effort involved in OPS, make the analysis more thorough and detailed, and minimize or eliminate human errors. And OPS systems capture the expertise needed to create operating procedures and allow this experience to be used in the new situations. But there are the limitations of the OPS techniques that have been used. So in order to resolve this Problem, in this work we have proposed a new approach to utilize temporal constraints and specific process knowledge in temporal logic and description logic. We have demonstrated its remarkable effectiveness in a boiler plant.

  • PDF

Recent Developments in High-Flux Heat Transfer Tubes (最近의 高性能傳熱管의 開發)

  • 서정윤
    • Journal of the KSME
    • /
    • v.18 no.3
    • /
    • pp.18-24
    • /
    • 1978
  • 열고환기에는 boiler와 같이 다량의 열 energy를 취급하는 것을 비롯하여 가정용 냉장고, 냉방기 기와 같이 비교적 적은 양의 열 energy를 취급하는것, 가종 고온 gas-gas 열교환기, 초전도송전 등의 초저온기기에 부속되는 저온열교환기 혹은 배열회수, 태양열이용을 위한 장치에 포함되는 열교환기등이 있으며, 그 종류와 내용에 있어서 다양하다. 따라서 새 형식의 열교환기 혹은 우수 한 전열특성을 갖는 표면, 형상을 갖는 전열관의 연구, 개발은 한층더 절실하게 요망된다. 최근주 목을 받고 있는 열교환기용전열관중에는 관축방향을 따라 표면을 파상으로 가공한 것(corrugate 식)과 축과 평형이 되게 만든 좁은 흠을 갖는 관(fluted tube)등이 있는데 이들에 있어서는 다같 이 표면의 요철에 의한 면부근의 난동을 촉진시켜서 우수한 대류열전달의 특성을 갖도록 하고 있다. 한편 응축과 비등등의 상변화를 동반하는 열전달에 대해서는 세구, 기공질금속층, 세공등을 갖는 면에 관해서 새로운 관심이 집중되고 있다. 이 후자의 전열면은 유축열전달에서는 평활면보 다 약10배의 높은 열전달율을 가지며 불등열전달에서는 벽면과 액의 온도차는 평활면의 경우보다 약1/5의 값을 갖는다. 동시에 한계열유속은 5활이상으로 증가시킬 수 있음이 알려져 있다. 따라서 본론에서는 후자의 전열면중에서 최근에 알려진 비약적으로 높은 전열성능을 갖는 전열면에 관해 서 소개하기로 한다.

  • PDF

Characteristics of Various Ranks of Coal Gasification with $CO_2$ by Gas Analysis (가스분석을 이용한 석탄 종류별 $CO_2$ 가스화 반응특성 연구)

  • Kim, Yong-Tack;Seo, Dong-Kyun;Hwang, Jung-Ho
    • Journal of the Korean Society of Combustion
    • /
    • v.15 no.2
    • /
    • pp.41-49
    • /
    • 2010
  • Various coals from many countries around the world have been used for pulverized coal boiler in power plants in Korea. In this study, the gasification reactivities of various coal chars with $CO_2$ were investigated. Carbon conversion was measured using a real time gas analyzer with NDIR CO/$CO_2$ sensor. In a lab scale furnace, each coal sample was devolatilized at $950^{\circ}C$ in nitrogen atmosphere and became coal char and then further heated up to reach to a desired temperature. Each char was then gasified with $CO_2$ under isothermal conditions. The reactivities of coal chars were investigated at different temperatures. The shrinking core model (SCM) and volume reaction model(VRM) were used to interpret the experiment data. It was found that the SCM and VRM could describe well the experimental results within the carbon conversion of 0-0.98. The gasification rates for various coals were very different. The gasification rate for any coal increased as the volatile matter content increased.

An Investigation on Flow and Structural Characteristics of Heat Exchanger in Rankine Steam Cycle for Co-generation System (기관 폐열 회수를 위한 열교환기의 Baffle 길이 변경에 따른 성능 예측에 관한 수치 해석적 연구)

  • Ryu, Kyuhyenn;Kim, Kusung;Lee, Younghum;Kang, Seokho;Park, Gibeom
    • New & Renewable Energy
    • /
    • v.9 no.4
    • /
    • pp.32-39
    • /
    • 2013
  • A 2-loop waste heat recovery system with Rankine steam cycles for the improvement of fuel efficiency of gasoline vehicles has been investigated. A high temperature loop is used to recover waste heat from exhaust gas and a low temperature loop is used to recover waste heat from cold engine coolant. This paper has dealt with a layout of low temperature loop system, the review of the velocity contours through numerical analysis. According to the result of analysis, the designed heat exchanger. And comparing with flow analysis results, LT Boiler is safe to operation.