• Title/Summary/Keyword: GAP-43

Search Result 437, Processing Time 0.036 seconds

Dielectric functions of $Cd_{1-x}Mg_xTe(0\leqx\leq0.43)$ alloy films studied by ellipsometry (타원편광분석기를 이용한 $Cd_{1-x}Mg_xTe(0\leqx\leq0.43)$ 박막 화합물의 유전율 함수 연구)

  • 구민상;이민수;김태중;김영동;박인규
    • Journal of the Korean Vacuum Society
    • /
    • v.9 no.3
    • /
    • pp.254-257
    • /
    • 2000
  • We report spectroscopic ellipsometric (SE) measurements on $Cd_{1-x}Mg_x/Te$ (0$\leq$x$\leq$0.43) films grown on GaAs substrate. When compared with previous bulk data, at first, current spectrum shows clear interference oscillations below $E_0$ band gap energy, which means the transparent characteristic of direct transition material below $E_0$ edge. It proves that the film samples used for this work have the most interrupted surface of high quality reported so far by SE. Secondly the best resolution of $E_2$-peak is observed, so we can report clear splitting of E$_2$and $E_0'$ band gap energies. We also performed the multilayer calculation necessary to remove this interference oscillations to observe $E_0'$ band gap energy of $Cd_{1-x}Mg_x/Te$ (x=0.23) film.

  • PDF

Electro-optical Characteristics of VA mode LCOS depending on Cell Gap (VA Mode의 LCOS에서 Cell Gap의 변화에 따른 전기광학적 특성)

  • Kang, Jung-Won;Son, Hong-Bae
    • Journal of the Semiconductor & Display Technology
    • /
    • v.7 no.3
    • /
    • pp.41-43
    • /
    • 2008
  • The electro-optical characteristics of the Liquid Crystal on Silicon (hereinafter "LCOS") micro-display on vertically alignment (VA) mode were studied depending on various cell gaps. 5 different cell gaps, such as $1.4{\mu}m,\;1.8{\mu}m,\;2.1{\mu}m,\;2.4{\mu}m$ and $2.8{\mu}m$, were selected. The reflectance-voltage (R-V) characteristics, distributions of reflected light and reflectance were calculated with 3-dimmensional LC code. At the center of cell, the smallest $1.4{\mu}m$ cell gap showed the lowest reflectance and the largest $2.8{\mu}m$ cell gap showed the highest reflectance due to the surface anchoring effect. In case of $2.1{\mu}m$ cell gap, the sum of reflectance overall cell was the highest value. Considering the reflectance and RV curve characteristic, the optimized cell gap was $2.1{\mu}m$.

  • PDF

Decomposing the Gender Pay Gap among Doctorate Holders (박사학위 소지자의 성별 임금격차 분해에 관한 연구)

  • Park, Kihong
    • Journal of Labour Economics
    • /
    • v.41 no.3
    • /
    • pp.61-93
    • /
    • 2018
  • This paper examines the gender pay gap among doctorate holders in Korea to understand the determinants of this gap and control of its variation. A particular focus of this study is to seek to infer the extent to which this pay gap is the consequence of gender-based disparate treatment. The main results indicate that there is a sizeable gender pay gap even among workers with doctorate degrees, that is, very highly educated workers. Moreover, this gender pay gap cannot be largely explained by gender differences in characteristics, indicating the existence of discrimination against female doctorate holders in the Korean labor market.

  • PDF

Parametric study on earthquake induced pounding between adjacent buildings

  • Naserkhaki, Sadegh;Abdul Aziz, Farah N.A.;Pourmohammad, Hassan
    • Structural Engineering and Mechanics
    • /
    • v.43 no.4
    • /
    • pp.503-526
    • /
    • 2012
  • Pounding between closely located adjacent buildings is a serious issue of dense cities in the earthquake prone areas. Seismic responses of adjacent buildings subjected to earthquake induced pounding are numerically studied in this paper. The adjacent buildings are modeled as the lumped mass shear buildings subjected to earthquake acceleration and the pounding forces are modeled as the Kelvin contact force model. The Kelvin model is activated when the separation gap is closed and the buildings pound together. Characteristics of the Kelvin model are extensively explored and a new procedure is proposed to determine its stiffness. The developed model is solved numerically and a SDOF pounding case as well as a MDOF pounding case of multistory adjacent buildings are elaborated and discussed. Effects of different separation gaps, building heights and earthquake excitations on the seismic responses of adjacent buildings are obtained. Results show that the seismic responses of adjacent buildings are affected negatively by the pounding. More stories pound together and pounding is more intense if the separation gap is smaller. When the height of buildings differs significantly, the taller building is almost unaffected while the shorter building is affected detrimentally. Finally, the buildings should be analyzed case by case considering the potential earthquake excitation in the area.