• Title/Summary/Keyword: GAITRite system

Search Result 62, Processing Time 0.028 seconds

Analysis of Spatio-Temporal Parameters of Gait in Elderly by Various Walking Pathways Width (보행경로 너비에 따른 노인의 시 · 공간적 보행 분석)

  • Son, Ho-Hee;Kim, Eun-Jung
    • The Journal of the Korea Contents Association
    • /
    • v.13 no.10
    • /
    • pp.444-451
    • /
    • 2013
  • The purpose of this study was to investigate the changes in temporospatial variables in healthy elderly and healthy adults during usual walking, narrow base walking and centerline-guided walking. Twenty healthy elderly and nineteen healthy adults were participated in this study. In each conditions, the subjects were walked on a 6m walkway at comfortable self-selected speeds under three conditions : (1) usual walking, (2) walking within a 50% of the distance between the subject's ASIS (3) walking along a centerline. GAITRite system was used for kinematic analysis to assess the temporospatial variables. There were no significant changes in healthy adults(p>.05), but walking speed, cadence, H-H base support, functional ambulation performance were significantly decreased progressively as pathway narrowed in elderly adults(p<.05). The results show that elderly people had more difficulty with walking on narrow pathway for fear of falling. This study provides data for use in basic research into safe walking and preventing falling for elderly.

Case Report of Multiple Cerebral Infarction in Middle Cerebral Artery with Gait Disturbance Treated by Korean Medicine (중대뇌동맥 영역에 발생한 다발성 뇌경색 환자의 보행장애에 대한 한의 복합 치료: 증례보고 1례)

  • Chae, In-cheol;Choi, In-woo;Yang, Ji-hae;Kang, Jie-yoon;Ryu, Ju-young;Jung, Eun-sun;Kim, Yoon-sik;Seol, In-chan;Yoo, Ho-ryong
    • The Journal of Internal Korean Medicine
    • /
    • v.42 no.2
    • /
    • pp.75-85
    • /
    • 2021
  • Objectives: This study reported about a patient with a right middle cerebral artery infarction whose gait disturbance was improved by Korean medicine treatment. Methods: The patient was treated with a Korean herbal medicine (Gami-yukmijihwang-tang) along with acupuncture, electroacupuncture, moxibustion, cupping, and physical therapy. The treatment effect was evaluated with the manual muscle test (MMT) and the Korean version of the modified Barthel index (K-MBI). The gait of the patient was evaluated by a 10-m walk test (10MWT), the timed up and go (TUG) test, the functional ambulation profile (FAP) score, and the functional ambulatory category (FAC) score. Spatiotemporal parameters were evaluated using a walkway system (GAITRite®, CIR Systems, Inc., USA). Results: After 83 days of traditional Korean medicine treatment, the K-MBI and FAC scores improved from 50 to 70 and from 1 to 4, respectively. The 10MWT and TUG tests also improved from 24.86 to 16.66 sec and from 22.35 to 17.62 sec, respectively. GAITRite® measurements reflected gait improvements: the FAP score improved from 55 to 86 sec; the step time improved from 0.72 to 0.669 sec; the step length improved from 31.076 cm to 41.284 cm; the gait velocity improved from 42.8 cm/sec to 64.1 cm/sec; the cadence improved from 93.6 steps/min to 90.8 steps/min. No adverse effects resulting from treatment or evaluation occurred during the admission period. Conclusions: This study suggests that traditional Korean medicine treatment may reduce symptoms and improve the quality of life in patients with cerebral infarction.

Change in Gait Parameters by Arm Sling Types in Healthy Adults (팔걸이 형태에 따른 정상인의 보행변수 변화)

  • Lee, Ok-Kyoung;An, Duk-Hyun
    • The Journal of the Korea Contents Association
    • /
    • v.10 no.5
    • /
    • pp.267-276
    • /
    • 2010
  • The purpose of this study was to investigate the variations in gait parameters according to arm slings used in healthy adults. Twenty healthy adults (9 males, 11 females) participated in this study and walked at self-selected speeds on a GAITRite-instrumented carpet. They were randomly assigned conditions: without an arm sling, a care sling, a Harris hemi arm sling, a CVA sling, and a Rolyan humeral cuff sling. The following gait parameters were analyzed: the temporo-spatial parameters of gait velocity, swing phase, single support, cadence. In the comparison of parameters in each trial, step length was statistically significantly changed(p=.002). The right step length was significantly decreased in the Harris hemi arm sling and increased in the Rolyan humeral cuff sling when compared with no sling. This study found that several different types arm slings varied gait pattern in healthy adults.

Influence of Smart Phone Use on Gait Pattern in Healthy Adults (스마트폰 사용이 건강한 성인의 보행패턴에 미치는 영향)

  • Moon, Jong-Hoon;Kim, Sung-Hyun;Na, Chang-Ho;Hong, Deok-Gi;Heo, Sung-Jin
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.13 no.1
    • /
    • pp.199-206
    • /
    • 2018
  • This study was to investigate the Influence of smart phone use on gait in healthy adults. Twenty healthy adults were recruited in this study. All subjects performed twice for each normal gait and smart phone gait. The normal gait walked at their chosen speed, and the smart phone gait walked while watching the video. GAITRite system was used to identify the temporal and spatial variables related to the gait pattern during walking. Statistical analysis was analyzed by paired t-test. In comparison of temporal variables, smart phone gait was significantly lower in gait speed and cadence than in normal gait(p<.05), and was significantly longer in single support time and double support time(p<.05). In comparison of spatial variables, smart phone gait was significantly shorter in step length and stride length than in normal gait(p<.05) and significantly longer in step width(p<.05). The results of this study demonstrated that smartphone use can negatively affect the correct gait patterns during walking.

A Comparison of Gait Patterns in Young Asian and Caucasian Women (젊은 아시아인과 코카시아 여성의 보행 패턴 비교)

  • Kwon, Soonjung
    • Physical Therapy Korea
    • /
    • v.5 no.4
    • /
    • pp.30-40
    • /
    • 1998
  • 이 연구의 목적은 젊은 아시아인과 코카시아 여성의 보행패턴 중 보폭시간(step time) 과 보폭 (step length)을 비교하고 두 집단의 골반넓이와 보폭과 상관관계가 있는지 알아보는 것이다. 연구대상자는 15명의 아시아인과 15명의 코카시아 여성이었으며 나이는 23세에서 35세 범위에 있었다. 보행분석을 위해서는 GAITRite System을 사용하였으며 분석방법으로는 인종(아시아인대 코카시아인)과 신체부위(좌측, 우측)를 요인으로 하여 반복측정에 의한 분산분석을 하였다. 아시아인 여성보다 코카시아인 여성의 보폭, 다리길이, 골반 넓이가 통계학적으로 유의하게 높았고 왼쪽 다리의 걸음과 오른쪽 다리의 걸음에 있어서는 통계학적으로 유의한 차이가 없었다. 그리고 보폭시간, 속도, 걸음수(cadence)에 있어서도 두 여성 인종간에 통계학적으로 유의한 차이가 없었다. 이러한 결과는 보행변수 중에서 걸음수나 속도와 같은 시간변수에 았어서는 아시아인 여성과 코카시아인 여성간에 차이가 없음을 의미한다.

  • PDF

Immediate Effect of Kinesiology Taping on Gait Function in Stroke Patients with Foot Drop

  • Kim, Jinuk
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.11 no.2
    • /
    • pp.2060-2064
    • /
    • 2020
  • Background: Recently, the kinesiology taping (KT) method was reported to be effective in improving walking ability in foot drop patients after stroke, but the clinical basis is still unclear. Objectives: The KT method was compared with ankle-foot orthotics (AFO) to investigate gait ability in foot drop patients after stroke. Design: Crossover study design. Methods: In this study, 11 stroke patients with foot drop participated. Walking ability of all subjects for both conditions (KT and AFO) was measured using the GAITRite system. The order of application of the two conditions was determined randomly by drawing lots. Wilcoxon signed-rank test was used to compare walking ability between the two conditions. The level of statistical significance was set at P<.05. Results: There were no significant differences between the KT and AFO methods in terms of velocity, cadence, step length, and stride length (P>.05, all). Conclusion: This study recommends KT as an alternative to the AFO, since KT provides evidence of preventing of foot drops and improving gait ability in stroke patient.

Effect of kinesio taping on gait function in elderly individuals with knee osteoarthritis: A pilot study

  • Park, Jaeyoung;Paik, Youngrim;Oh, Donghwan
    • Journal of International Academy of Physical Therapy Research
    • /
    • v.10 no.3
    • /
    • pp.1830-1833
    • /
    • 2019
  • Background: Knee osteoarthritis (OA) causes not only pain during walking but also walking disorders. Therefore, intervention for older patients with OA is important. Objective: To study investigated the effects of kinesio taping (KT) on pain and walking ability in elderly persons with knee OA. Design: One group, pre-post design Methods: This study enrolled 12 community-dwelling elderly people with knee OA. KT was applied on the surrounding structures, including the patellar and bilateral lateral ligaments. Assessment was made using the visual analog scale and GAITRite system to measure pain and walking ability during KT and non-KT conditions. Results: In this study, compared to the non-KT condition, the KT condition showed a significant improvement in walking ability and pain reduction during walking (velocity, cadence, step length, and stride length) (p < 0.05). Conclusion: This study demonstrated that knee KT has a positive effect on pain reduction and walking ability of the elderly with OA.

The Study of Gait Parameter and Plantar Foot Pressure during Walking in Adults with Down Syndrome (다운증후군 성인의 보행 특성과 족저압에 관한 연구)

  • Koo, Hyun-Mo
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.7 no.1
    • /
    • pp.21-28
    • /
    • 2012
  • Purpose : The purpose of this study was to examine the gait parameter and plantar foot pressure of adults with Down syndrome(DS) during walking in order to provide data for developing evidence-based deficit or common rehabilitation strategies. Method : 15 participants with DS(12 men, 3 women; age $26.06{\pm}4.47$) and 15 healthy subjects(12 men, 3 women; age $25.33{\pm}3.43$) were matched age. They walked at self selected speeds on a GAITRite system and RS-scan system, and had the following measurements done: cadence, stride length, step width, foot angle, percent stance, percent double support, and plantar foot pressure in 10 areas of the foot. Results : In comparison of gait parameter(cadence, stride length, step width, foot angle, percent stance, and percent double support) between adults with DS and healthy subjects, there was significant differences(p<.05). Regarding plantar foot pressure during gait with or without DS, there were statisically significant differences in the area of Toes 1-5, Metatasal 1-4, Midfoot, and Heel(Medial and lateral)(p<.05). Conclusion : Our data show that DS walk with a less physiolosical gait pattern and plantar foot pressure than healthy subjects. Based on our results, DS patients need targeted rehabilitation and exercise strategies.

The Effect of Modified Reverse-Six Taping on the Balance and Gait Performance in Pes Planus - Pilot study (수정된 리버스 식스 테이핑 적용이 편평족의 균형과 보행에 미치는 영향 - 사전연구)

  • Yang, Seong-hwa;Shin, Young-il;Lee, Jun-young
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.22 no.1
    • /
    • pp.35-41
    • /
    • 2016
  • Background: The purpose of this study was to investigate the effect of modified reverse-six taping on the balance and gait performance in Pes Planus. Methods: A total of twelve subjects (4 males, 8 females) in Pes Planus participated in this study. Navicular drop test was used to evaluate Pes Planus. Balance performance(anterior-posterior; A-P, medial-lateral; M-L), overall) was evaluated using the Biodex balance system in two difference condition(no-taping, with reverse-six taping). Gait performance (cadence, velocity) was evaluated using GAITRite System in two difference condition (no-taping, with reverse-six taping). Results: There were significant improvements of A-P and overall in the balance performance after using reverse-six taping (p<.05). there was no significant improvements of M-L balance performance. and, there were no statistical difference of cadence and velocity in the gait performance after using reverse-six taping. Conclusions: This study found that modified reverse-six taping in Pes Planus was improve the balance performance. but dose not affect the gait performance.

  • PDF

Clinical Feasibility of Wearable Robot Orthosis on Gait and Balance Ability for Stroke Rehabilitation: A Case Study

  • Shin, Young-Il;Yang, Seong-Hwa;Kim, Jin-Young
    • The Journal of Korean Physical Therapy
    • /
    • v.27 no.2
    • /
    • pp.124-127
    • /
    • 2015
  • Purpose: The emphasis on gait rehabilitation after stroke depends on training support through the lower limbs, balance of body mass over the changing base of support. However, muscle weakness, lack of control of lower limb, and poor balance can interfere with training after stroke. For this case study report, a wearable robot orthosis was applied to stroke patients in order to verify its actual applicability on balance and gait ability in the clinical field. Methods: Two stroke patients participated in the training using the wearable robot orthosis. Wearable robot orthosis provides patient-initiated active assistance contraction during training. Training includes weight shift training, standing up and sitting down, ground walking, and stair up and down Training was applied a total of 20 times, five times a week for 4 weeks, for 30 minutes a day. Gait ability was determined by Stance phase symmetry profile, Swing phase symmetry profile, and velocity using the GAITRite system. Balance ability was measured using the Biodex balance system. Results: Subjects 1, 2 showed improved gait and balance ability with mean individual improvement of 72.4% for velocity, 19.4% for stance phase symmetry profile, 9.6% for swing phase symmetry profile, and 13.6% for balance ability. Conclusion: Training utilizing a wearable robot orthosis can be useful for improvement of the gait and balance ability of stroke patients.