• 제목/요약/키워드: GAC regeneration

검색결과 18건 처리시간 0.021초

고도 정수처리장에서의 과불화합물 거동 (Behavior of perfluorinated compounds in advanced water treatment plant)

  • 임채승;김형준;한개희;김호;황윤빈;김극태
    • 상하수도학회지
    • /
    • 제34권5호
    • /
    • pp.323-334
    • /
    • 2020
  • Adsorption by granule activated carbon(GAC) is recognized as an efficient method for the removal of perfluorinated compounds(PFCs) in water, while the poor regeneration and exchange cycles of granule active carbon make it difficult to sustain adsorption capacity for PFCs. In this study, the behavior of PFCs in the effluent of wastewater treatment plant (S), the raw water and the effluents of drinking water treatment plants (M1 and M2) located in Nakdong river waegwan watershed was monitored. Optimal regeneration and exchange cycles was also investigated in drinking water treatment plants and lab-scale adsorption tower for stable PFCs removal. The mean effluent concentration of PFCs was 0.044 0.04 PFHxS g/L, 0.000 0.00 PFOS g/L, 0.037 0.011 PFOA g/L, for S wastewater treatment plant, 0.023 0.073 PFHxS g/L, 0.000 0.00 PFOS g/L, 0.013 0.008 PFOA g/L for M1 drinking water treatment plant and 0.023 0.073 PFHxS g/L, 0.000 0.01 PFOS g/L, 0.011 0.009 PFOA g/L for M2 drinking water treatment plant. The adsorption breakthrough behaviors of PFCs in GAC of drinking water treatment plant and lab-scale adsorption tower indicated that reactivating carbon 3 times per year suggested to achieve and maintain good removal of PFASs. Considering the results of mass balance, the adsorption amount of PFCs was improved by using GAC with high-specific surface area (2,500㎡/g), so that the regeneration cycle might be increased from 4 months to 10 months even if powdered activated carbon(PAC) could be alternatives. This study provides useful insights into the removal of PFCs in drinking water treatment plant.

정전위전해에 의한 활성탄에 함유된 페놀 제거 (Removal of Phenol Loaded with Activated Carbon by Potentiostatic Method)

  • 김성우;박승조
    • 자원리싸이클링
    • /
    • 제10권4호
    • /
    • pp.18-23
    • /
    • 2001
  • 페놀을 함유한 폐 활성탄의 가열 재생시 대기 오염물인 페놀이 생성되어 환경을 오염시키므로 발생하는 페놀 제거에 대한 검토가 필요하다 본 연구에서 실험에 사용하여 페놀을 함유한 S.회사 활성탄(WS-GAC), C.회사 활성탄(WC-GAC), L.회사 활성탄(UL-GAC)의 전해산화는 정전위 전해방식으로 실험하였다. 시료에 함유된 페놀농도는 100 rng/g, 지지 전해질은 1.0% 염화나트륨 용액, Ti-Ir(10$\times$10$ extrm{cm}^2$)전극 간격은 2 cm,전류밀도는 $1.25 A/dm^2$인 조건에서 실험이 이루워졌을 경우 전해 산화 실험에서 얻은 결과 페놀의 잔류물은 검출되지 않았다. 그러므로 전해산화 반응에서 빈응시간, 전류밀도, 지지전해질의 농도, 전극간의 거리가 60 minutes, 1.25 $A/dm^2$, 1.0%, 2 cm 임을 알 수 있었다.

  • PDF

UV/GAC 흡착산화 공법을 이용한 원자력 발전소 2차 계통 냉각수로부터 발생하는 에탄올 아민 함유 폐수처리 (Treatment of Wastewater Containing Ethanolamine from Coolant of the Secondary System of Nuclear Power Plant by UV/GAC Adsorption Oxidation Method)

  • 최민준;김한수
    • 공업화학
    • /
    • 제28권3호
    • /
    • pp.318-325
    • /
    • 2017
  • 원자력발전소 2차 계통수에 사용되는 에탄올아민이 포함된 오염수는 복수탈염설비의 이온교환수지에서 포집된다. 이온교환수지의 재생과정에서 에탄올아민과 다량의 이온성 물질이 포함된 강산성 폐수가 발생된다. 본 연구는 이온교환수지에서 발생하는 폐수를 처리하기 위해서 자외선 산화방법을 적용하였다. 산화방법은 흡착제를 함께 사용한 자외선 산화와 흡착제를 적용하지 않고 자외선 산화만 적용할 수 있는 장치를 개발하여 자외선 산화방법에서 흡착제가 폐수처리 성능에 미치는 영향을 파악하였다. 연구 결과는 입상활성탄을 흡착제로 적용한 UV/GAC산화공정은 pH 12.8에서 COD 제거 효율은 71.3%로 나타났다. 동일한 pH 조건에서 흡착제를 적용하지 않은 UV 산화공정보다 COD 제거 효율이 21.8% 높게 나타났다. T-N의 제거는 pH 12.8일 때 88.6%로 흡착제를 적용하지 않은 UV산화공정보다 18.0% 높게 나타났다. 이와 같은 결과는 입상활성탄이 에탄올아민을 고정시켜서, UV 램프에 의한 산화공정의 효율을 높이는 것으로 여겨진다. 따라서 UV/GAC 흡착산화공정이 에탄올아민 함유 폐수의 처리에 더 효율적이다.

산화망간피복여재를 이용한 용존망간 제거 (Soluble Manganese Removal Using Manganese Oxide Coated Media (MOCM))

  • 김진근;정세채;고수현
    • 상하수도학회지
    • /
    • 제20권6호
    • /
    • pp.813-822
    • /
    • 2006
  • Soluble manganese removal was analyzed as a function of filter media, filter depth, presence or absence of chlorination, and surface manganese oxide concentration in water treatment processes. Sand, manganese oxide coated sand (MOCS), sand+MOCS, and granular activated carbon(GAC) were used as filter media. Manganese removal, surface manganese oxide concentration, turbidity removal, and regeneration of MOCS in various filter media were investigated. Results indicated that soluble manganese removal in MOCS was rapid and efficient, and most of the removal happened at the top of the filter. When filter influent (residual chlorine 1.0mg/L) with an average manganese concentration of 0.204mg/L was fed through a filter column, the sand+MOCS and MOCS columns can remove 98.9% and 99.2% of manganese respectively on an annual basis. On the other hand, manganese removal in sand and the GAC column was minimal during the initial stage of filtration, but after 8 months of filter run they removed 99% and 35% of manganese, respectively. Sand turned into MOCS after a certain period of filtration, while GAC did not. In MOCS, the manganese adsorption rate on the filter media was inversely proportional to the filter depth, while the density of media was proportional to the filter depth.

Adsorption and Thermal Regeneration of Toluene and Benzene on the Fixed Bed Packed with Activated Carbon and Activated Carbon Fiber

  • Kim, Jong-Hwa;Oh, Ok-Kyun;Haam, Seung-Joo;Lee, Chang-Ha;Kim, Woo-Sik
    • Carbon letters
    • /
    • 제2권1호
    • /
    • pp.44-54
    • /
    • 2001
  • The characteristics of adsorption and desorption of benzene and toluene were investigated at a fixed bed packed with the activated carbon and activated carbon fiber. Through breakthrough experiments under various feed concentration conditions, it was found that the slope of mass transfer zone and the tailing in the breakthrough curves were different from the feed conditions due to different heats of adsorption. In hot nitrogen desorption, the regeneration time and mass transfer zone of the toluene desorption curve were longer than those of the benzene desorption curve because of the difference in adsorption affinity. With an increase in the regeneration temperature, the height of roll-up and the sharpness of desorption curves increased but the regeneration times decreased. The adsorption capacities of the activated carbon and activated carbon fiber after three-time thermal regenerations decreased about 25% and 37% for benzene and 18% and 25% for toluene, respectively. To investigate the effect of the regeneration temperature on the energetic efficiency, the characteristic desorption temperatures of toluene and benzene were investigated by calculating purge gas consumption and temperature.

  • PDF

입자상 활성탄의 흡착과 재생에 의한 PCBs 오염제거 (Decontamination of PCBs by Hybrid Adsorption/Regeneration on Granular Activated Carbon)

  • 홍용표;최종하
    • 대한화학회지
    • /
    • 제46권2호
    • /
    • pp.117-124
    • /
    • 2002
  • 활성탄에 흡착되어 있는 유기질을 처리하기 위하여 역류산화반응이 개발되었고 그것에 대한 평가가 이루어 졌다. 역류산화반응이란 산소의 흐름과 반대로 이동하는 자발적인 불꽃을 이용하여 유기질을 파괴 및 제거함과 동시에 폐활성탄을 재생하는 방법이다. 본 연구를 통하여 얻어진 실험결과를 고찰해 보면, 활성탄의 질량손실과 불꽃의 온도가 산소의 흐름속도에 절대적으로 의존하였고, 재생탄의 비표면적이 거의 완전히 회복되었으며, 특히 활성탄에 흡착되어 있는 열에 안정한 PCBs를 거의 완전히 파괴 및 제거(99.99%이상)할 수 있었다.

메조공극 흡착제를 이용한 상수원수내 맛·냄새 유발물질 제거특성 평가 (Evaluation of Removal Characteristics of Taste and Odor Causing Compounds using Meso-Porous Absorbent)

  • 김종두;박철휘;윤여복;이대성;김효전;강석태
    • 대한환경공학회지
    • /
    • 제39권1호
    • /
    • pp.26-33
    • /
    • 2017
  • 본 연구의 목적은 메조공극 흡착제(Meso-Porous Adsorbent, MPA)에 대한 흡착특성을 평가하고, 상수원수 내 맛 냄새유발물질인 geosmin에 대한 흡착제거 특성을 회분식 실험을 통해 평가하는데 있다. 등온흡착에 대한 실험결과는 일반적으로 적용되고 있는 Langmuir식과 Freundlich식을 이용하여 분석하였으며, MPA는 Langmuir식과 Freundlich식 모두 잘 따르는 것으로 나타났다. 그리고 흡착속도 평가를 위해 1차 속도식과 2차 속도식을 각각 적용하였다. 본 흡착특성 평가결과 MPA를 이용할 경우 기존 입상활성탄에 비해 최대 흡착량이 7배 가량 낮은 것으로 나타났으나 1차 속도식 기준으로 흡착속도는 11배 이상 빠른 것으로 나타났다. 따라서 MPA를 정수장에 적용할 경우 짧은 EBCT 조건에서도 효과적으로 상수원수 내 geosmin을 제거할 수 있을 것으로 판단되며, 활성탄 공정에 비해 재생주기가 짧을 것으로 판단된다.

VPB를 이용한 효율적인 Gas 상태의 BTEX 제거에 관한 연구 (Effective Removal of Gaseous BTEX Using VPB During Treatment of Briny Produced Water)

  • 권순동
    • 한국물환경학회지
    • /
    • 제27권2호
    • /
    • pp.167-177
    • /
    • 2011
  • Oil이나 Gas생산시 발생하는 Produced water의 양은 미국 내에서만 연간 수십억 배럴에 육박한다. 이러한 Produced water의 재이용을 위한 첫 번째 과제는 유해 유기물질을 제거하는 것으로, 본 연구에서는 수중의 BTEX를 가스상태로 변화시킨 후 Vapor phase biofilter (VPB)로 분해, 제거 효능을 평가하였다. VPB 시스템은 짧은 기간의 시스템 shutdown에는 거의 영향을 받지 않는 것으로 나타났다. 그러나 주입 되는 농도가 Peak 형태를 가질때는 제거효능의 저하가 관찰 되었으며, 이중 Benzene이 가장 민감하게 반응하였다. 이를 위한 해결책으로 GAC로 충진된 Buffering Column이 사용되었으며, 이는 peak 형태의 유입농도 Profile을 완만한 형태로 buffering하는 역할을 하였다. 현장 적용을 통하여, 본 시스템이 Produced water내에 존재하는 용존 BTEX를 효과적으 로 제거할 수 있음을 확인하였다.