• Title/Summary/Keyword: G-sensitivity

Search Result 1,367, Processing Time 0.033 seconds

Relationship between the Body Fat Mass Measured by Bioelectrical Impedance Analysis(BIA) and Dual Energy X-ray Absorptiometry(DEXA), and by the Indices of Insulin Sensitivity (생체 임피던스 방법과 이중 방사선 흡수법으로 측정한 체지방량과 인슐린감수성 지표와의 연관성)

  • Lim, In Seok;Yun, Ki Wook
    • Clinical and Experimental Pediatrics
    • /
    • v.48 no.8
    • /
    • pp.857-864
    • /
    • 2005
  • Purpose : The objectives of this study was to evaluate the correlations between the indices of insulin sensitivity using fasting glucose and insulin level, and the body fat mass measured by bioelectrical impedance analysis(BIA) and dual energy X-ray absorptiometry(DEXA), and to determine the clinical usefulness of insulin sensitivity indices when obese children were followed up. Methods : In this study, 28 simple obese children and adolescents were included. Anthropometric data including body weight, height, obesity degree(OD), body mass index(BMI), and waist-to-hip ratio were collected and then body fat mass was measured by using BIA and DEXA. For metabolic data, 12 hour fasting serum glucose, insulin and lipid profiles were measured and indices for insulin sensitivity(G/I ratio, $log_{insulin}$, HOMA-IR, $log_{HOMA-IR}$, QUICKI) were calculated. Results : BMI had a higher correlation with insulin sensitivity indices than OD(G/I ratio, -0.463 vs -0.209; $log_{insulin}$, 0.417 vs 0.196; HOMA-IR, 0.301 vs 0.238; $log_{HOMA-IR}$, 0.403 vs 0.198; QUICKI, -0.451 vs -0.224). But OD had a higher correlation with body fat mass measured by BIA and DEXA than BMI(BIA, 0.612 vs 0.316; DEXA, 0.667 vs 0.512). The G/I ratio was correlated with body fat mass in BIA(r=-0.420, P<0.05) and DEXA(r=-0.512, P<0.01), percentage of body fat(percentage of fat) in BIA(r=-0.366, P<0.05) and DEXA(r=-0.449, P<0.01). HOMA-IR was only correlated with body fat mass in DEXA(r=0.341, P<0.05). Conclusion : This study revealed that G/I ratios had a statistically significant correlation with anthropometric obesity indices(OD and BMI) and also had a correlation with both body fat mass and percentage of fat. These results suggest that G/I ratios could be used as useful index when obese children and adolescence are followed up.

Serological Identification of Mastitic Streptococci by Lancefield Grouping and Antibiotic Sensitivity Test (Lancefield Grouping에 의한 유방염유래(乳房炎由來) Streptococcus의 동정(同定)과 항생물질(抗生物質)에 대한 감수성조사(感受性調査))

  • Seok, Ho Bong;Lee, Hyun Soo
    • Korean Journal of Veterinary Research
    • /
    • v.15 no.1
    • /
    • pp.69-73
    • /
    • 1975
  • A Total of 173 streptococci isolated from 536 dairy cattle in Gyeonggi Province identified by Lancefield serological reaction and other biological properties. Antibiotics sensitivity test was also examined and the results obtained were as follows: 1. A total of 173 isolates of 167 strains (96.5%) were reacted with group A,B,C,D,E and G antisera. 2. Of the 167 positive strains, 75 strains were identified to Streptooccus uberis, 56 to Streptococcus agalactiage and 26 to Streptococcus dysgactiae, respectively. Also, Sreptococcus pyogenes, group D and group G streptococci were rarely isolated. 3. In results of antibiotic sensitivity tests, the most isolates were sensitive to leucomycin and erythromycin but less sensitive to streptomycin. and kanamycin.

  • PDF

Fabrication of six-beam accelerometer with self-eliminated off-axis sensitivity by summing circuit (합산회로를 통하여 타축감도가 자체상쇄된 6빔 가속도센서의 제조)

  • 심준환;김동권;이종현
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.35D no.2
    • /
    • pp.33-39
    • /
    • 1998
  • A six-beam accelerometer with self-compensated off-axis sensitivity was fabricated onthe selectively diffused (111)-oriented n/n$^{+}$/n silicon substrates by a unique porous silicon micromachining technique, which has self-stip characteristics and highly seletive formation of porous silicon layer during anodic reaction. Also, the characteristics of the fabricated accelerometer were investigated. The sensitivity of the acceleormeter added up outputs of three bridges through a summing circuit was 0.68 mV/g and the nonlinearity was less than 2% of the full scale output. The measured first resonant frequency was 4.236 kHz. When the outputs of three bridges were compared to summing output of bridges obtained through summing circuit, the normal output for Z-axis acceleration exhibited the same value s summing outputs of three bridges without reduction of sensitivity and thus the sensitivity decrease due to additional beam was compensated. Although a maximum off-axis sensitivity in one bridge of the accelerometer showed 17% of normal sensitivity, the off axis sensitivity obtained from summing output of three bridges decreased to 1.0%. Therefore, the self-elimination of off-axis sensitivity can be simply realized by obtaining the output of the sensor through summing circuit.t.

  • PDF

The effect of parenting behaviors on the cyber delinquency in adolescents - The mediating effects of moral sensitivity - (부모양육행동이 청소년의 사이버일탈에 미치는 영향 - 도덕적 민감성의 매개효과 검증)

  • Lee, Hyun
    • Journal of Family Relations
    • /
    • v.22 no.2
    • /
    • pp.51-69
    • /
    • 2017
  • Objectives: The purpose of this study was to examine the associations and paths among parenting behaviors, cyber delinquency, and moral sensitivity in adolescents to reduce and prevent cyber delinquency. Method: The data was collected by a survey for 270 students from a middle school and a high school in G city. The valid 262 cases were analyzed by frequency, descriptive analysis with SPSS 18.0 and tested by structural equation model by using AMOS 18.0 program. Results: Results showed that 1) 'control' among the parenting behaviors has positive effects on the cyber delinquency in adolescents, 2) 'intimacy and rationality' among the parenting behaviors has positive impacts on the moral sensitivity, 3) it shows that moral sensitivity has negative effects on the cyber delinquency in adolescents, and 4) bootstrapping test for indirect effect of moral sensitivity was verified significantly. We founded the full mediation of moral sensitivity and the path of 'intimacy and rationality' to cyber delinquency through moral sensitivity. Conclusions: The results implied 1) provision of the parent education and program for parents and newlyweds to learn positive parenting behaviors and 2) application of moral education to develop moral sensitivity of adolescents in schools and communities.

Ginsenoside Rb1 ameliorates liver fat accumulation by upregulating perilipin expression in adipose tissue of db/db obese mice

  • Yu, Xizhong;Ye, Lifang;Zhang, Hao;Zhao, Juan;Wang, Guoqiang;Guo, Chao;Shang, Wenbin
    • Journal of Ginseng Research
    • /
    • v.39 no.3
    • /
    • pp.199-205
    • /
    • 2015
  • Background: Ginsenoside Rb1 (G-Rb1), the major active constituent of ginseng, improves insulin sensitivity and exerts antidiabetic effects. We tested whether the insulin-sensitizing and antidiabetic effects of G-Rb1 results from a reduction in ectopic fat accumulation, mediated by inhibition of lipolysis in adipocytes. Methods: Obese and diabetic db/db mice were treated with daily doses of 20 mg/kg G-Rb1 for 14 days. Hepatic fat accumulation was evaluated by measuring liver weight and triglyceride content. Levels of blood glucose and serum insulin were used to evaluate insulin sensitivity in db/db mice. Lipolysis in adipocytes was evaluated by measuring plasma-free fatty acids and glycerol release from 3T3-L1 adipocytes treated with G-Rb1. The expression of relevant genes was analyzed by western blotting, quantitative real-time polymerase chain reaction, and enzyme-linked immunosorbent assay kit. Results: G-Rb1 increased insulin sensitivity and alleviated hepatic fat accumulation in obese diabetic db/db mice, and these effects were accompanied by reduced liver weight and hepatic triglyceride content. Furthermore, G-Rb1 lowered the levels of free fatty acids in obese mice, which may contribute to a decline in hepatic lipid accumulation. Corresponding to these results, G-Rb1 significantly suppressed lipolysis in 3T3-L1 adipocytes and upregulated the perilipin expression in both 3T3-L1 adipocytes and mouse epididymal fat pads. Moreover, G-Rb1 increased the level of adiponectin and reduced that of tumor necrosis factor-${\alpha}$ in obese mice, and these effects were confirmed in 3T3-L1 adipocytes. Conclusion: G-Rb1 may improve insulin sensitivity in obese and diabetic db/db mice by reducing hepatic fat accumulation and suppressing adipocyte lipolysis; these effects may be mediated via the upregulation of perilipin expression in adipocytes.

Hemoglobin, Hematocrit and Serum Ferritin as Markers of Iron Status (빈혈판정 지표로서의 헤모글로빈, 헤마토크릿 및 혈청 페리틴)

  • 정해랑;문현경;송범호;김미경
    • Journal of Nutrition and Health
    • /
    • v.24 no.5
    • /
    • pp.450-457
    • /
    • 1991
  • The iron status of 57 female college students was evaluated by measurements of hemoglobinCHb). hematocritCHct) and serum ferritin(Ferritin). Mean values for Hb, Hct and Ferritin were $13.9\pm$ 0.96g/dl, $41.4\pm$ 2.85% and $20.7\pm$ l5.5ng/mL respectively. Ferritin as well as Hb. Hct were not statistically different from normal distribution. although ferritin were skewed to the right. The prevalence of anemia defined by Hb < 12g/dI. Hct ~36 % and Ferritin <12ng/ml were found to be 5.3, 10.3 and 36.8%, respectively. By using Hb as a screening tool at a cutoff point of 12g/dI. 2.8% of healthy subjects will be incorrectly classified as anemic and 90.5 % of anemic as healthy. Sensitivity and specificity were calculated at various cutoff points of Hb and Hct. The estimates of sensitivity and specificity allow Hb 14.0g/dl as cutoff point for good predictor of anemia.

  • PDF

Development of a Rapid Diagnostic Test Kit to Detect IgG/IgM Antibody against Zika Virus Using Monoclonal Antibodies to the Envelope and Non-structural Protein 1 of the Virus

  • Kim, Yeong Hoon;Lee, Jihoo;Kim, Young-Eun;Chong, Chom-Kyu;Pinchemel, Yanaihara;Reisdorfer, Francis;Coelho, Joyce Brito;Dias, Ronaldo Ferreira;Bae, Pan Kee;Gusmao, Zuinara Pereira Maia;Ahn, Hye-Jin;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.56 no.1
    • /
    • pp.61-70
    • /
    • 2018
  • We developed a Rapid Diagnostic Test (RDT) kit for detecting IgG/IgM antibodies against Zika virus (ZIKV) using monoclonal antibodies to the envelope (E) and non-structural protein 1 (NS1) of ZIKV. These proteins were produced using baculovirus expression vector with Sf9 cells. Monoclonal antibodies J2G7 to NS1 and J5E1 to E protein were selected and conjugated with colloidal gold to produce the Zika IgG/IgM RDT kit (Zika RDT). Comparisons with ELISA, plaque reduction neutralization test (PRNT), and PCR were done to investigate the analytical sensitivity of Zika RDT, which resulted in 100% identical results. Sensitivity and specificity of Zika RDT in a field test was determined using positive and negative samples from Brazil and Korea. The diagnostic accuracy of Zika RDT was fairly high; sensitivity and specificity for IgG was 99.0 and 99.3%, respectively, while for IgM it was 96.7 and 98.7%, respectively. Cross reaction with dengue virus was evaluated using anti-Dengue Mixed Titer Performance Panel (PVD201), in which the Zika RDT showed cross-reactions with DENV in 16.7% and 5.6% in IgG and IgM, respectively. Cross reactions were not observed with West Nile, yellow fever, and hepatitis C virus infected sera. Zika RDT kit is very simple to use, rapid to assay, and very sensitive, and highly specific. Therefore, it would serve as a choice of method for point-of-care diagnosis and large scale surveys of ZIKV infection under clinical or field conditions worldwide in endemic areas.

Diagnostic Value of Fecal Calprotectin as a Screening Biomarker for Gastrointestinal Malignancies

  • Khoshbaten, Manouchehr;Pishahang, Parinaz;Nouri, Mohammad;Lashkari, Alireza;Alizadeh, Mahasti;Rostami-Nejad, Mohammad
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.15 no.4
    • /
    • pp.1667-1670
    • /
    • 2014
  • Background: Calprotectin in feces seems to be a more sensitive marker for gastrointestinal (GI) cancers than fecal occult blood, but its specificity may be too low for screening average risk populations. This study aims at evaluating the diagnostic value of fecal calprotectin as a screening biomarker for GI malignancies. Materials and Methods: In a case-control study, 100 patients with GI malignancies (50 patients with colorectal cancer and 50 patients with gastric cancer) and 50 controls were recruited in Tabriz Imam Reza and Sina hospitals during a 24-month period. One to two weeks after the last endoscopy/colonoscopy, fecal specimens were collected by the patients and examined by ELISA method for quantitative measurement of calprotectin content. The results were compared between the three groups. Results: The mean fecal calprotectin level was $109.1{\pm}105.3$ (2.3-454.3, median:74), $241.1{\pm}205.2$ (3.4-610.0, median:19.3) and $45.9{\pm}55.1{\mu}g/g$ (1.3-257.1, median:19.3) in gastric cancer, colorectal cancer and control group, respectively, the differences being significant (p<0.001) and remaining after adjustment for age. The optimal cut-off point for fecal calprotectin was ${\geq}75.8{\mu}g/g$ for distinguishing colorectal cancer from normal cases (sensitivity and specificity of 80% and 84%, respectively). This value was ${\geq}41.9{\mu}g/g$ for distinguishing gastric cancer from normal cases (sensitivity and specificity of 62%). Conclusions: Our results revealed that fecal calprotectin might be a useful and non-invasive biomarker for distinguishing colorectal cancer from non-malignant GI conditions. However, due to low sensitivity and specificity, this biomarker may not help physicians distinguishing gastric cancer cases from healthy subjects.

Cantilever beam vibration sensor based on the axial property of fiber Bragg grating

  • Casas-Ramos, Miguel A.;Sandoval-Romero, G.E.
    • Smart Structures and Systems
    • /
    • v.19 no.6
    • /
    • pp.625-631
    • /
    • 2017
  • In the fields of civil engineering and seismology, it is essential to detect and tracking the vibrations, and the fiber Bragg gratings (FBGs) are typically used as sensors to measure vibrations. Where, one of the most popular and detailed approaches to use FBGs as vibration sensors involves the use of cantilever beam designs, which adds a mass to measure low and moderate frequencies (from 20 Hz up to 1 kHz) with high sensitivities (greater than 10 pm/g). The design consists of a bending strain in the cantilever that is simultaneously transferred to the FBG, resulting in a shift in the wavelength that is proportional to the strain experienced by the cantilever. In this work, we present the experimental results of a vibration sensor design using a cantilever beam to generate an axial uniform strain in the FBG in-line with the vertical axis, which modifies the cantilever's natural frequency that allows the sensor to have a wide frequency broadband without losing sensitivity. This sensor achieved a sensitivity of about 339 pm/g and a natural frequency of 227.3 Hz. The presented design compared with the traditional cantilever beam-based FBG vibration sensors, has the advantages of a simple design for detection on vibration-sensitive structures and its physical parameters can be easily modified in order to satisfy the requirements of the desired vibration measurements.