• 제목/요약/키워드: G-sensitivity

검색결과 1,367건 처리시간 0.027초

진동형 MEMS 자이로스코프 G-민감도 오차에 관한 연구 (A Study on the G-Sensitivity Error of MEMS Vibratory Gyroscopes)

  • 박병수
    • 전기학회논문지
    • /
    • 제63권8호
    • /
    • pp.1075-1079
    • /
    • 2014
  • In this paper, we describe the analysis and the compensation method of the g-sensitivity error for MEMS vibratory gyroscopes. Usually, the g-sensitivity error has been ignored in the commercial MEMS gyroscope, but it deserves our attention to apply for the missile application as a tactical grade performance. Thus, it is necessary to compensate for the g-sensitivity error to reach a tactical grade performance. Generally, the g-sensitivity error seems intuitively to be a gyroscope bias error proportional to the linear acceleration. However, we assert that the g-sensitivity error mainly causes not a bias error but a scale-factor error. And we verify that the g-sensitivity scale-factor error occurs due to the non-linearity of parallel plate electrodes. Therefore, we propose the compensation method to remove the g-sensitivity scale-factor error. The experimental result showed that a proposed compensation method improved successfully the performance of the MEMS vibratory gyroscope.

관성센서 오차 모델을 이용한 진동형 MEMS 자이로스코프 G-민감도 환산계수 오차 추출 기법 (The Extraction Method for the G-Sensitivity Scale-Factor Error of a MEMS Vibratory Gyroscope Using the Inertial Sensor Model)

  • 박병수;한경준;이상우;유명종
    • 한국항공우주학회지
    • /
    • 제47권6호
    • /
    • pp.438-445
    • /
    • 2019
  • 본 논문에서는 MEMS 자이로스코프에서 발생하는 G-민감도 오차를 관성센서 오차 모델에 정의하고, 이를 분석하여 오차 성분을 추출하는 기법을 제안한다. 일반적으로 MEMS기반 자이로스코프는 스프링과 관성질량체를 갖는 진동형 방식으로 개발된다. 따라서 구조적으로 고기동 환경에서 인가되는 가속도에 비례하는 G-민감도 오차 특성을 갖게 된다. 이러한 G-민감도 오차는 외부에서 높은 가속도가 인가되지 않는 민수분야에서는 무시할 정도로 작다. 하지만 전술급 성능의 MEMS 관성측정기가 고가속 환경에서 외란과 가속도에 의해 G-민감도 오차가 발생하게 되면 항체의 유도조종을 위한 항법장치 성능에 큰 영향을 미치게 되므로 오차 분석과 보상은 필수적이다. 따라서 본 논문에서는 MEMS 자이로스코프에 발생하는 G-민감도 오차를 분석하고 정의하여 관성센서 오차모델에 적용한다. 새로 정의된 관성센서 오차모델을 분석하여, 오차 성분을 고가속도 시험환경이 아닌 FMS 시험만으로 정확히 추출하는 방법을 제안한다. 그리고 제안한 방법으로 얻은 오차를 보상하여 고가속도 시험을 수행하고 그 결과를 분석하여 성능과 신뢰성을 검증한다.

CuTBT(Copper-tetra-tert-buthylphthalocyanine) LB막의 Chemiresistor Device 특성에 관한 연구 (A Study on the Chemiresistor Device characteristics of the CuTBP(Copper-tetra -tert-buthylphthalocyanine) LB films)

  • 이창희;구자룡;김태완;김정수
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1996년도 춘계학술대회 논문집
    • /
    • pp.6.2-8
    • /
    • 1996
  • The NO$_2$ GAS-detection characteristic of CuTBT (Copper-tetra-tert-butylphtha1ocyanine) LB films were investigated through a study of current-voltage (I-V) characteristics with a variation of number N of interdigital electrodes (N=1∼25). A concentration of 200ppm NO$_2$ gas was used. It was found that a conductance G increases monotonically as the number of interdigital electrode increases, and a sensitivity $\Delta$G ($\Delta$G=G$\_$gas//G$\_$air/) is at least higher than 50 and stable. As far as a sensitivity is concerned, the sensitivity when N=26 is greater than that when N=1 by 70 or so. It indicates that the number of interdigital electrodes affects the currents, sensitivity and stability.

Sensitivity Enhancement of Surface Plasmon Resonance Biosensor with Colloidal Gold

  • Kibong Choi;Hee
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • 제3권1호
    • /
    • pp.19-23
    • /
    • 1998
  • We enhanced the sensitivity of surface plasmon resonance biosensor by the conversion of the real-time direct binding immunoassay into the sandwich immunoassay, in which colloidal gold particles coated with anti-mouse IgG was used. By the immobilization of anti-mouse IgG onto the carboxymethyl dextran surface of thin gold film, the direct binding of analyte(mouse IgG) onto the sensor chip, and the injection of colloidal gold particles coated with anti-mouse IgG, about 100 times of sensitivity enhancement was obtained. This result suggests that nanoparticles, which has a high refractive index, homogeneous ultrafine structure and capability of size control, would be applicable for the detection of very small quantity of biomaterial.

  • PDF

Comparing the effect of a desensitizing material and a self-etch adhesive on dentin sensitivity after periodontal surgery: a randomized clinical trial

  • Hajizadeh, Hila;Nemati-Karimooy, Atefeh;Majidinia, Sara;Moeintaghavi, Amir;Ghavamnasiri, Marjaneh
    • Restorative Dentistry and Endodontics
    • /
    • 제42권3호
    • /
    • pp.168-175
    • /
    • 2017
  • Objectives: This double-blind randomized placebo-controlled clinical trial evaluated the ability of a desensitizing agent and a self-etch adhesive on cervical dentin sensitivity (CDS) after periodontal surgery. Materials and Methods: Ninety hypersensitive teeth of 13 subjects were included in the study. After periodontal surgery, the teeth of each posterior sextant treated with one of the following materials: G1: Clearfil $S^3$ Bond (Kuraray Dental), G2: Gluma Desensitizer (Heraeus Kulzer), and G3: placebo (water). The sensitivity was assessed using evaporative stimuli before treatment (baseline, T0), 1 day after treatment (T1), after 1 week (T2), and 1 month (T3) according to visual analog scale (VAS). Results: Following the treatment, all the 3 groups showed significant reduction of CDS in T1 compared to T0. Reduction of CDS between T1 and T2 was observed only in G1 but there was no significant difference between T2 and T3 in this group. Although we observed a significant difference in T3 compared to T1 and T2 in G2 and G3, comparison of treatment groups in each assessment time showed a significant difference only in T3. According to paired comparison, this was due to the difference between G2 and G3. Conclusions: Dentin sensitivity following periodontal surgery will decrease spontaneously over time, but treating the sensitive teeth with Gluma Desensitizer and Clearfil $S^3$ Bond can have some benefits.

The Sensitivity Comparison of Immunodiagnostic Assays for Diagnosing Dengue Fever

  • Zahoor, Muhammad;Bahadar, Haji;Uddin, Salah;Naz, Sumaira
    • 대한임상검사과학회지
    • /
    • 제48권4호
    • /
    • pp.275-279
    • /
    • 2016
  • Dengue fever is a vector borne disease caused by a dengue virus. It is an RNA virus of the family flaviviridae, with different serotypes. Herein, we report our attempt to carry out a sensitivity comparison of immunodiagnostic assays for dengue fever in dengue positive patients. Blood samples from 189 volunteers were collected. To determine the sensitivity of the NS1 test, two different types of tests-immunochromatographic tri-line test and rapid dengue test (RDT)-as well as IgM and IgG capture ELISA were performed. The result of RDT has shown that 59.7% of volunteers were IgM positive and 50.2% were IgG positive. Conversely, the results from capture ELISA shows 79.8% and 59.7% for IgM and IgG, respectively. The sensitivity of the capture ELISA test for IgM and IgG was higher than that of immunochromatographic tri-line rapid test, but the specificity was lower. Therefore, to confirm dengue fever, we recommend performing more detailed, investigative tests since a single test may not be sufficient.

Novel graphene-based optical MEMS accelerometer dependent on intensity modulation

  • Ahmadian, Mehdi;Jafari, Kian;Sharifi, Mohammad Javad
    • ETRI Journal
    • /
    • 제40권6호
    • /
    • pp.794-801
    • /
    • 2018
  • This paper proposes a novel graphene-based optical microelectromechanical systems MEMS accelerometer that is dependent on the intensity modulation and optical properties of graphene. The designed sensing system includes a multilayer graphene finger, a laser diode (LD) light source, a photodiode, and integrated optical waveguides. The proposed accelerometer provides several advantages, such as negligible cross-axis sensitivity, appropriate linearity behavior in the operation range, a relatively broad measurement range, and a significantly wider bandwidth when compared with other important contributions in the literature. Furthermore, the functional characteristics of the proposed device are designed analytically, and are then confirmed using numerical methods. Based on the simulation results, the functional characteristics are as follows: a mechanical sensitivity of 1,019 nm/g, an optical sensitivity of 145.7 %/g, a resonance frequency of 15,553 Hz, a bandwidth of 7 kHz, and a measurement range of ${\pm}10g$. Owing to the obtained functional characteristics, the proposed device is suitable for several applications in which high sensitivity and wide bandwidth are required simultaneously.

Effect of troglitazone on radiation sensitivity in cervix cancer cells

  • An, Zhengzhe;Liu, Xianguang;Song, Hye-Jin;Choi, Chi-Hwan;Kim, Won-Dong;Yu, Jae-Ran;Park, Woo-Yoon
    • Radiation Oncology Journal
    • /
    • 제30권2호
    • /
    • pp.78-87
    • /
    • 2012
  • Purpose: Troglitazone (TRO) is a peroxisome proliferator-activated receptor ${\gamma}$ ($PPAR{\gamma}$) agonist. TRO has antiproliferative activity on many kinds of cancer cells via G1 arrest. TRO also increases $Cu^{2+}/Zn^{2+}$-superoxide dismutase (CuZnSOD) and catalase. Cell cycle, and SOD and catalase may affect on radiation sensitivity. We investigated the effect of TRO on radiation sensitivity in cancer cells in vitro. Materials and Methods: Three human cervix cancer cell lines (HeLa, Me180, and SiHa) were used. The protein expressions of SOD and catalase, and catalase activities were measured at 2-10 ${\mu}M$ of TRO for 24 hours. Cell cycle was evaluated with flow cytometry. Reactive oxygen species (ROS) was measured using 2',7'-dichlorofluorescin diacetate. Cell survival by radiation was measured with clonogenic assay. Results: By 5 ${\mu}M$ TRO for 24 hours, the mRNA, protein expression and activity of catalase were increased in all three cell lines. G0-G1 phase cells were increased in HeLa and Me180 by 5 ${\mu}M$ TRO for 24 hours, but those were not increased in SiHa. By pretreatment with 5 ${\mu}M$ TRO radiation sensitivity was increased in HeLa and Me180, but it was decreased in SiHa. In Me180, with 2 ${\mu}M$ TRO which increased catalase but not increased G0-G1 cells, radiosensitization was not observed. ROS produced by radiation was decreased with TRO. Conclusion: TRO increases radiation sensitivity through G0-G1 arrest or decreases radiation sensitivity through catalase-mediated ROS scavenging according to TRO dose or cell types. The change of radiation sensitivity by combined with TRO is not dependent on the PPAR ${\gamma}$ expression level.

Performance Evaluation of the Automated Fluorescent Immunoassay System Rotavirus Assay in Clinical Samples

  • Kim, Jae-Seok;Lee, Su-Kyung;Ko, Dae-Hyun;Hyun, Jungwon;Kim, Hyun Soo
    • Annals of Laboratory Medicine
    • /
    • 제39권1호
    • /
    • pp.50-57
    • /
    • 2019
  • Background: The Automated Fluorescent Immunoassay System (AFIAS) rotavirus assay (Boditech Med Inc., Chuncheon, Korea) is a new rapid antigen test for rotavirus detection. We evaluated the performance of this assay for detecting rotaviruses and their specific genotypes in clinical stool samples. Methods: AFIAS rotavirus assay was performed in 103 rotavirus-positive and 103 rotavirus-negative stool samples (confirmed by both PCR and ELISA), and its results were compared with those of PCR, ELISA, and immunochromatographic assay (ICA). We evaluated diagnostic sensitivity/specificity, the detectability of rotavirus subtypes, lower limit of detection (LLOD), reproducibility, cross-reactivity, and interference of AFIAS rotavirus assay. Results: Based on PCR and ELISA results, diagnostic sensitivity and specificity of the AFIAS rotavirus assay were both 99.0%. LLOD results showed that the AFIAS assay had sensitivity similar to or greater than ICA and ELISA. High reproducibility was confirmed, and no cross-reactivity or interference was detected. This assay could detect genotypes G1P[8], G2P[4], G3P[8], G4P[6], G4P[8], G8P[4], G8P[8], G9P[4], and G9P[8]. Conclusions: The AFIAS rotavirus assay showed high reproducibility, sensitivity, and specificity as well as excellent agreement with ELISA, PCR, and ICA. It detected the most common as well as unusual genotypes of rotavirus prevalent in Korea. It could be a useful onsite assay for rapid, convenient, and cost-effective detection of rotavirus infection.

Antibiotic sensitivity and resistance of bacteria from odontogenic maxillofacial abscesses

  • Kang, Sang-Hoon;Kim, Moon-Key
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • 제45권6호
    • /
    • pp.324-331
    • /
    • 2019
  • Objectives: This study investigated the types and antibiotic sensitivity of bacteria in odontogenic abscesses. Materials and Methods: Pus specimens from 1,772 patients were collected from affected areas during incision and drainage, and bacterial cultures and antibiotic sensitivity tests were performed. The number of antibiotic-resistant bacteria was analyzed relative to the total number of bacteria that were tested for antibiotic susceptibility. Results: Bacterial cultures from 1,772 patients showed a total of 2,489 bacterial species, 2,101 gram-positive and 388 gram-negative. For penicillin G susceptibility tests, 2 out of 31 Staphylococcus aureus strains tested showed sensitivity and 29 showed resistance. For ampicillin susceptibility tests, all 11 S. aureus strains tested showed resistance. In ampicillin susceptibility tests, 46 out of 50 Klebsiella pneumoniae subsp. pneumoniae strains tested showed resistance. Conclusion: When treating odontogenic maxillofacial abscesses, it is appropriate to use antibiotics other than penicillin G and ampicillin as the first-line treatment.