• Title/Summary/Keyword: Fx-LMS Algorithm

Search Result 31, Processing Time 0.026 seconds

Characteristics of Real-time Implementation using the Advanced System Controller in ANC Systems (개선된 시스템 제어기를 사용한 능동소음제어의 실시간 구현 특성)

  • Moon, Hak-ryong;Shon, Jin-geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.267-272
    • /
    • 2015
  • Active noise control (ANC) is a method of cancelling a noise signal in an acoustic cavity by generating an appropriate anti-noise signal via canceling loudspeakers. The continuous progress of ANC involves the development of improved adaptive signal processing algorithms, transducers, and DSP hardware. In this paper, the convergence behavior and the stability of the FxLMS algorithm in ANC systems with real-time implementation is proposed. Specially, The advanced DSP H/W with dual core(DSP+ARM) and API(application programming interface) S/W programming was developed to improve the real-time implementation performance under the FxLMS algorithms of input noise such as road noise environment. The experimental results are found to be in good agreement with the theoretical predictions.

Analysis of Bi-directional Filtered-x Least Mean Square Algorithm (양방향 Filtered-x 최소 평균 제곱 알고리듬에 대한 해석)

  • Kwon, Oh Sang
    • Journal of Korea Society of Digital Industry and Information Management
    • /
    • v.10 no.4
    • /
    • pp.133-142
    • /
    • 2014
  • The least mean square(LMS) algorithm has been popular owing to its simplicity, stability, and availability to implement. But it inherently has a problem of slow convergence speed, and the presence of a transfer function in the secondary path following the adaptive controller and the error path has been shown to generally degrade the stability and the performance of the LMS algorithm in applications of acoustical noise control. In general, in order to solve these problems, the filtered-x LMS (FX-LMS) type algorithms can be used and the bi-directional Filtered-x LMS(BFXLMS) algorithm is very attractive among them, which increase the convergence speed and the performance of the controller with nearly equivalent computation complexity. In this paper, a mathematical analysis for the BFXLMS algorithm is presented. In terms of view points of time domain, frequency domain, and stochastic domain, the characteristics and stabilities of algorithm is accurately analyzed.

Characteristics of Expanded-CLMS Algorithm for Performance Improvement in ANC Systems for Road Noise Calming (도로소음 정온화를 위한 ANC시스템에서 성능개선을 위한 Expanded-CLMS 알고리즘의 특성)

  • Moon, Hak-ryong;Shon, Jin-geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.3
    • /
    • pp.169-174
    • /
    • 2015
  • Noise problem that occurs on the road is raising a lot of problems in the economic, social and environmental aspects. The active noise control (ANC) systems based on the filtered-X least mean square(FxLMS) algorithm have a problem with compensating the acoustic feedback of secondary route. However, newly proposed correlation-LMS(CLMS) and expanded CLMS algorithms have slightly much calculation and are minutely behind performance, these have a advantage not in measuring transfer function onerously so that we can easily adapt these in real time. The CLMS and expanded CLMS algorithm was developed to improve the real-time implementation performance under the variable input noise such as road noise environment. In this paper, we compared and analyzed their performance. From the results of the Matlab simulation for an ANC system, it is shown that expanded CLMS algorithms are more convergence speed and keep the desirable performance even in the input of road noise situation.

Secondary Path Estimation Algorithm Based on Residual Music Canceller for Noise Cancelling Headphone (노이즈 캔슬링 헤드폰에 적합한 잔여 음악 제거기 기반의 2차 경로 추정 알고리즘)

  • Ji, Youna;Lee, Keunsang;Park, Youngcheol
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.5
    • /
    • pp.377-384
    • /
    • 2015
  • An active noise control (ANC) algorithm for noise canceling headphone is proposed. In this study, the feedback ANC operated with the filtered-x least mean square algorithm (FxLMS) algorithm is used to attenuate the undesired noise. Also an adaptive residual music canceller (RMC) is proposed for enhancing the accuracy of the reference signal of the feedback ANC. Simulation results show that a high quality of music sound can be consistently achieved in a time-varying secondary path situation.

Active Airframe Vibration Control Simulations of Lift-offset Compound Helicopters in High-Speed Flights (고속 비행의 Lift-offset 복합형 헬리콥터 기체의 능동 진동 제어 시뮬레이션)

  • Hong, Sung-Boo;Kwon, Young-Min;Kim, Ji-Su;Lee, Yu-Been;Park, Byeong-Hyeon;Shin, Hyun-Cheol;Park, Jae-Sang
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.357-367
    • /
    • 2021
  • This paper studies the simulations of active airframe vibration controls for the Sikorsky X2 helicopter with a lift-offset coaxial rotor. The 4P hub vibratory loads of the X2TD rotor are obtained from the previous work using a rotorcraft comprehensive analysis code, CAMRAD II. The finite element analysis software, MSC.NASTRAN, is used to model the structural dynamics of the X2TD airframe and to analyze the 4P vibration responses of the airframe. A simulation study using Active Vibration Control System(AVCS) with Fx-LMS algorithm to reduce the airframe vibrations is conducted. The present AVCS is modeled using MATLAB Simulink. When AVCS is applied to the X2TD airframe at 250 knots, the 4P longitudinal and vertical vibration responses at the specified airframe positions, such as the pilot seat, co-pilot seat, engine deck, and prop gearbox, are reduced by 30.65 ~ 94.12 %.

Analysis of Applicability of Active Noise Control (ANC) technique for Reducing Inter-Floor Noise in Apartment Buildings (공동주택 층간소음 저감을 위한 능동소음제어(ANC) 기술 적용가능성 분석)

  • Nam, Jin-Won;Kim, Ho-Jin;Kim, Jun-Hwan;Wee, Hyuk;Kim, Joong-Kwan
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.26 no.5
    • /
    • pp.49-56
    • /
    • 2022
  • In this study, numerical simulations for reducing noise between floors in an apartment building was carried out using Active Noise Control (ANC) technology. In order to examine the feasibility of using ANC to reduce noise between floors, accelerometers and microphones for noise collection were installed in the inter-floor noise test facility to measure noise and vibration caused by the impact ball drop test. By using the measured data, Filtered-x Least Mean Square (Fx-LMS) algorithm-based ANC simulations were carried out. In the simulations, after deriving optimal simulation conditions including the adaptive control convergence coefficient, the noise reduction effect was analyzed through numerical simulations using the number of installed accelerometers and speakers as variables. Finally, it was confirmed that the noise between floors could be reduced using ANC technology under limited conditions.

Active control of pump noise of dishwashers using FxLMS algorithm (FxLMS 알고리듬 기법을 이용한 식기 세척기의 펌프 소음 능동 제어)

  • Tark, Un-su;Oh, Han-Eum;Hong, Chinsuk;Jeong, Weui-Bong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.40 no.1
    • /
    • pp.46-54
    • /
    • 2021
  • In this paper, active noise control was performed to reduce radiated noise in the low frequency band of dishwashers. First, through an analysis of the noise environment of the dishwasher, it was confirmed that the pump noise contributed the most to the radiated noise in the low frequency band, From the result of the noise environment analysis, the reference signal was selected to be the vibration signal of the pump body. The reference signal was obtained by using the accelerometer on the pump body, which can prevent acoustic feedback. The error signal sensor was selected as a microphone located at 1 m in front of the dishwasher and 0.5 m in height. And to design the controller, the error signal and the reference signal were measured at the operational rpms of the dishwasher at 2,500 rpm, 2,600 rpm and 2,800 rpm, and the secondary path transfer function was measured. The designed controller was mounted on Digital Signal Processor (DSP) equipment, and the control performance was verified experimentally. As a result of the measurement at the 3 operational rpms, the 7th multiple component of pump operating frequency decreased by 1.93 dB, 4.43 dB, 5.15 dB per rpm, and the 12th multiple component decreased by 6.67 dB, 2.34 dB, 4.28 dB per rpm. And overall Sound Pressure Level (SPL) decreased by 0.84 dB, 2.58 dB, 1.48 dB by rpm.

A Filtered-x Affine Projection Sign Algorithm with Improved Convergence Rate for Active Impulsive Noise Control (능동 충격성 소음 제어를 위한 향상된 수렴 속도를 가지는 Filtered-x 인접 투사 부호 알고리즘)

  • Lee, En Jong;Kim, Jeong Rae;Chung, Ik Joo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.34 no.2
    • /
    • pp.130-137
    • /
    • 2015
  • In this paper, we propose a new Modified Filtered-x Affine Projection Sign Algorithm(MFxAPSA) to improve the convergence speed of the conventional MFxAPSA which has been proposed for active control of impulsive noise. Under the impulsive noise environment, the adaptive algorithms based on the second order moment such as the Filtered-x Least Mean Square(FxLMS) show slow convergence speed or diverge because the noise source tends to have infinite variance. The MFxAPSA is the algorithm derived by applying the Affine Projection Sign Algorithm(APSA) to active noise control. The APSA has an advantage that it does not need the calculation for the inverse matrix, so it may be suitable for the active noise control that requires low computational burden. The proposed MFxAPSA also has APSA's advantage and furthermore, better performance than the conventional MFxAPSA. We carried out a performance comparison of the proposed MFxAPSA with the conventional MFxAPSA. It is shown that the proposed MFxAPSA has the faster convergence speed than the conventional MFxAPSA.

A Nonlinear Filtered-X LMS Algorithm for the Nonlinear Compensation of the Secondary Path in Active Noise Control (능동 소음 제어 시스템의 2차 경로 비선형 특성을 보상하기 위한 적응 비선형 Filtered-X Least Mean Square (FX-LMS) 알고리듬)

  • Jeong, I.S.;Kim, D.H.;Nam, S.W.
    • Proceedings of the KIEE Conference
    • /
    • 2004.11c
    • /
    • pp.565-567
    • /
    • 2004
  • In active noise control (ANC) systems, the convergence behavior of the conventional Filtered-X Least Mean Square (FXLMS) algorithm may be affected by nonlinear distortions in the secondary path (e.g., in the power amplifiers, loudspeakers, transducers, etc.), which may lead to degradation of the error-reduction performance of the ANC systems. In this paper, a stable FXLMS algorithm with fast convergence is proposed to compensate for undesirable nonlinear distortions in the secondary-path of ANC systems by employing the Volterra filtering approach. In particular, the proposed approach is based on the utilization of the conventional P-th order inverse approach to nonlinearity compensation in the secondary path of ANC systems. Finally, the simulation results showed that the proposed approach yields a better convergence behavior In the nonlinear ANC systems than the conventional FXLMS.

  • PDF

Performance Improvement of ANC System for Wireless Headset (무선헤드셋을 위한 능동 잡음 제거기의 성능 개선)

  • Park, Sung-Jin;Kim, Suk-Chan
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.36 no.6C
    • /
    • pp.343-348
    • /
    • 2011
  • This paper introduces a design for real time wireless headset using ANC (active noise control) system based on NFxLMS adaptive filter algorithm. The training time of the proposed system is significantly reduced by using the RMS delay spread of a channel as an error correction parameter, and convergence rate of the FxLMS filter has been improved with updating the coefficients of the NFxLMS filter, which we have got during the training process. Our system has shorter training time and better convergence rate at the same noise reduction level than the conventional system under real noisy environment.