• Title/Summary/Keyword: Future Distribution System

Search Result 815, Processing Time 0.024 seconds

Bitcoin and Cryptocurrency: Challenges, Opportunities and Future Works

  • FAUZI, Muhammad Ashraf;PAIMAN, Norazha;OTHMAN, Zarina
    • The Journal of Asian Finance, Economics and Business
    • /
    • v.7 no.8
    • /
    • pp.695-704
    • /
    • 2020
  • Bitcoin and other prominent cryptocurrencies have gained much attention since the last several years. Globally known as digital coin and virtual currency, this cryptocurrency is gained and traded within the blockchain system. The blockchain technology adopted in using the cryptocurrency has raised the eyebrows within the banking sector, government, stakeholders and individual investors. The rise of the cryptocurrency within this decade since the inception of Bitcoin in 2009 has taken the market by storm. Cryptocurrency is anticipated as the future currency that might replace the current paper currency worldwide. Even though the interest has caught the attention of users, many are not aware of its opportunities, drawbacks and challenges for the future. Researches on cryptocurrencies are still lacking and still at its infancy stage. In providing substantial guide and view to the academic field and users, this paper will discuss the opportunities in the cryptocurrency such as the security of its technology, low transaction cost and high investment return. The originality of this paper is on the discussion within law and regulation, high energy consumption, possibility of crash and bubble, and attacks on network. The future undertakings of cryptocurrency and its application will be systematically reviewed in this paper.

AN OPTIMIZATION OF ONEBODY TYPE IMPLANT SYSTEM CONSIDERING VARIOUS DESIGN PARAMETERS (다양한 설계변수를 고려한 수직하중을 받는 일체형 임플랜트의 최적설계)

  • Choi Jae-Min;Chun Heoung-Jae;Lee Soo-Hong;Han Chong-Hyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.2
    • /
    • pp.185-196
    • /
    • 2006
  • Statement of problem: The researches on the influence of design variables on the stress distribution in cortical and trabecular bones and on optimal design for implant system were limited. Purpose: The purpose of this study is to identify the sensitivities of design parameters and to suggest the optimal parameters for designing the onebody type implant system. Material and methods: Stresses arising in the implant system were obtained by finite element analysis using a three dimensional model. An onebody type implant system[Oneplant (Warrantec. Co. Ltd., Korea)] was considered in this study. Vortical load(150 N) was applied on the top of the abutment along the axial direction. The initial design variables set for sensitivity analysis were radius of fixture, numbers of micro thread, numbers of power thread, height of micro thread, future length, tapered angle of future, inclined angle of thread, width of micro thread and width of power thread. The statistical technique of Design of Experiments(DOE) was applied tn the simulation model to deduce effective design parameters on stress distributions in bones. The deduced design parameters were incorporated into a fully automated design tool which is coupled with the finite element analysis and numerical optimization to determine the optimal design parameters. Results: 1. The result of sensitivity analysis showed six design variables - radius of future, tapered angle of fixture, inclined angle of thread, numbers of power thread, numbers of micro thread and height of micro thread - were more influential than the others. 2. The optimal values of design variables can be deduced by coupling finite element analysis (FEA) and design optimization tool(DOT).

Optimal Voltage Management Based on the Flexible, Reliable, Intelligent and Energy-conservative Distribution System (FRIENDS) (차세대 전기에너지공급시스템(FRIENDS)에 의한 최적 전압관리방안에 관한 연구)

  • 노대석
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.4 no.4
    • /
    • pp.409-417
    • /
    • 2003
  • In recent years, better quality in power electric services is being required with the development of information industries and the improvement of living standards. Also, the small scaled dispersed storage and generation (DSG) systems are being interconnected with the distribution systems and customers by the influence of the recent issues such as deregulation and global environmental problems in power system. Under these circumstances, it is very important to maintain the customer voltages within allowable limits for the distribution system which is located at the most sensitive part in the power system. To overcome these problems, this paper shows the basic concepts of FRIENDS which is considered as one of the power delivery system in the near future and also presents an evaluation method on the impacts of customer voltages by operation models of FRIENDS. The FRIENDS can change the system configuration in a flexible manner by using the static switches and offer the different power qualities in power services through the power quality control centers which play the most important role in FRIENDS. Numerical examples are shown in order to indicate the efficiency of the proposed method.

  • PDF

A Study on the development and application of graphic function for ADS (ADS 그래픽 기능 개발 적용 연구)

  • Park, S.W.;Yang, W.S.;Kim, K.H.;Oh, W.R.;Seo, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1992.07a
    • /
    • pp.165-168
    • /
    • 1992
  • The ADS system is applied and used in KEPCO. But it is short of graphic functions and on-line display of power system. In this study, we develpoed ADS MMI system which expands graphic functions of ADS, and enhanced efficiency of ADS system. And we showed system extension in the future and suggested a foundation of total distribution automation system.

  • PDF

AC transport current loss analysis for anti-parallel current flow in face-to-face stacks of superconducting tapes

  • Yoo, Jaeun;Han, Young-Hee;Kim, Hey-Rim;Park, Byung-Jun;Yang, Seong-Eun;Kim, Heesun;Yu, Seung-Duck;Park, Kijun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.16 no.2
    • /
    • pp.42-46
    • /
    • 2014
  • In this study we investigated ac transport current losses in the face to face stack for the anti-parallel current flow, and compared the electromagnetic properties with those of the single SC tape as well as those of the same stack for the parallel current path. The gap between the SC tapes in the stack varied in order to verify the electromagnetic influence of the neighbors when current flows in opposite direction, and the model was implemented in the finite element method program by the commercial software, COMSOL Multiphysics 4.2a. Conclusively speaking, the loss was remarkably decreased for the anti-parallel current case, which is attributed the magnetic flux compensation between the SC layers due to the opposite direction of the current flows. As the gap between SC tapes was increased, the loss mitigation became less effective. Besides, the current density distribution is very flat cross the sample width for the narrower gap case, which is believed to be benefit for the power electric system. These results are all in good agreement with those predicted theoretically for an infinite bifilar stack.

Tap Water Quality in Seoul Metropolitan Area (수도권상수도의 수질-문제점과 대책)

  • 김동치
    • Journal of environmental and Sanitary engineering
    • /
    • v.5 no.2
    • /
    • pp.15-21
    • /
    • 1990
  • Current analyses of tap water in Seoul metropolitan area prove the water is still safe, despite the Pollution of raw water source. However, it also significantly suggests that a feasibility study of apply, additional advanced technology to existing water treatment processes is needed in order to cope with future pollution. Also, the monitoring of water quality within private, multi-household buildings is important as the monitoring of public water distribution system.

  • PDF

A Study on Loop operation of 154kV Substation Distribution line for Stable power supply (안정적 전력공급을 위한 154kV 변전소 배전선로간 연계운영에 관한 연구)

  • Kim, Kwang-Ho;Son, Myoung-Gwon;Jeong, Jong-Chan
    • Journal of Industrial Technology
    • /
    • v.29 no.B
    • /
    • pp.221-228
    • /
    • 2009
  • For a stable supply of electric power, periodical inspection of the electric facilities and repair of the distribution lines are required. In case of any unexpected accidents, looped operation among distribution lines may be necessary in order to supply electricity through the sound lines, separating the faulted lines. As a result of this study, it was found that normal looped operation became impossible when phase difference of the looped distribution lines is more than 3 degrees compared with the voltage supply of the distribution lines. Therefore, for a stable supply of electric power to Chuncheon, it is judged to be desirable that looped operation of the distribution lines coming from the same substation M. Tr Bank shall be performed in principle and in case of looped operation with the substation of different system, looped operation among the lines shall be performed after voltage regulation of the substation M. Tr Bank, maintaining similar voltages and load supply volume in order to avoid phase difference through checking the operation conditions of each substation M. Tr Banks. And when looped operation among the distribution lines is scheduled, voltage regulation schedule has been established so far by calculating maximum supply volume through the transformer of the substation and the maximum load volume through the distribution lines but in the future, looped operation of the distribution lines shall be carried out by removing voltage difference with regulating tap or load of the surrounding transformers, with giving prior notice to the substation operators.

  • PDF

Risk analysis of the old pipe networks for priority determination of renovation (노후 상수관망 개량 우선순위 결정을 위한 구역별 위험도 분석)

  • Lee, Jae Hyeon;Lee, Sang Mok;Park, Byung Soo;Kwon, Hyuk Jae
    • Journal of Korea Water Resources Association
    • /
    • v.55 no.spc1
    • /
    • pp.1167-1175
    • /
    • 2022
  • In this study, management index method has been developed to estimate the level of deterioration, applied to Cheongju city, and compared with the previous estimation methods of deterioration level of water distribution system. From the results, distribution systems of Yullyang, Naedeok1 and Yongam2 are found to be seriously deteriorated. And it was also found that probability of pipe breakage was estimated as 3.21%, 4.64% which is highest level at the steel pipe of 200 mm and 300 mm diameter. It was found that risk degree was estimated as 0.2609, 0.2644 by using management index method in Naedeok1 which is the most dangerous distribution system in the city. It was also found that results of risk analysis by management index method have been similar with the results of safety analysis by reliability method and indirect estimation method of deterioration level. Therefore, newly developed management index method can be applied and may be useful to the estimation of deterioration level for the future maintenance and management of water distribution system.

Projection of Forest Vegetation Change by Applying Future Climate Change Scenario MIROC3.2 A1B (미래 기후변화 시나리오 MIROC3.2 A1B에 따른 우리나라 산림식생분포의 변화 전망)

  • Shin, Hyung-Jin;Park, Geun-Ae;Park, Min-Ji;Kim, Seong-Joon
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.15 no.1
    • /
    • pp.64-75
    • /
    • 2012
  • To predict the future distribution of forest vegetation, the present forest stand distributions of South Korea were represented by multinomial logit model with the following environmental variables: summer average precipitation, the coldest month average temperature, elevation, degree of base saturation, and soil organic matter. The future forest community was predicted by applying the MIROC3.2 hires A1B scenario. The future climate data were downscaled by statistically method. The coldest month average temperature increased $4.4^{\circ}C$, $6.0^{\circ}C$, and $9.4^{\circ}C$, and 3 months average precipitation changed -1.2%, 5.7%, and 5.3% for 2020s, 2050s, and 2080s respectively. For the projected summer precipitation and the coldest temperature, the future deciduous and mixed forests in the study area increased 56.9% and 8.3% and the coniferous forest decreased 11.2% in 2080s based on present.

A Study on the Visualization of HNS Hazard Levels to Prevent Accidents at Sea in Real-Time

  • Jeong, Min-Gi;Lee, Moonjin;Lee, Eun-Bang
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.23 no.3
    • /
    • pp.242-249
    • /
    • 2017
  • In order to develop an HNS safety management system to assess and visualize hazard levels via an automated method, we have conceptualized and configured a sample system. It is designed to quantify the risk of a vessel carrying HNS with a matrix method along navigational route and indicate hazards distribution with a contour map. The basic system which provides a visualized degree of hazards in real time has been introduced for the safe navigation of HNS ships. This is useful not only for decision making and circumstantial judgment but may also be utilized for HNS safety management with a risk base. Moreover, this system could be extended to address the navigational safety of marine traffic as well as of autonomous vessels in the near future if the sensors used are connected with IoT technology.