• Title/Summary/Keyword: Fusion imaging

Search Result 234, Processing Time 0.03 seconds

Generation of Simulated Geospatial Images from Global Elevation Model and SPOT Ortho-Image

  • Park, Wan Yong;Eo, Yang Dam
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.32 no.3
    • /
    • pp.217-223
    • /
    • 2014
  • With precise sensor position, attitude element, and imaging resolution, a simulated geospatial image can be generated. In this study, a satellite image is simulated using SPOT ortho-image and global elevation data, and the geometric similarity between original and simulated images is analyzed. Using a SPOT panchromatic image and high-density elevation data from a 1/5K digital topographic map data an ortho-image with 10-meter resolution was produced. The simulated image was then generated by exterior orientation parameters and global elevation data (SRTM1, GDEM2). Experimental results showed that (1) the agreement of the image simulation between pixel location from the SRTM1/GDEM2 and high-resolution elevation data is above 99% within one pixel; (2) SRTM1 is closer than GDEM2 to high-resolution elevation data; (3) the location of error occurrence is caused by the elevation difference of topographical objects between high-density elevation data generated from the Digital Terrain Model (DTM) and Digital Surface Model (DSM)-based global elevation data. Error occurrences were typically found at river boundaries, in urban areas, and in forests. In conclusion, this study showed that global elevation data are of practical use in generating simulated images with 10-meter resolution.

Study for Non-Destructive Testing of Polyethylene Electrofusion Joints - Ultrasonic Imaging test (폴리에틸렌 배관의 전기융착부 비파괴검사기술에 관한 연구)

  • Kil Seong Hee;Kwon Jeong Rock
    • Journal of the Korean Institute of Gas
    • /
    • v.8 no.3 s.24
    • /
    • pp.31-36
    • /
    • 2004
  • Electrofusion(EF) joints have been widely used as they are easy to fuse and suitable for high-quality joints for polyethylene(PE) pipes. This paper studies the cause of defects and classifies 5 types of defects. The defect detection technique for electrofusion joints of polyethylene piping is utilized by the ultrasonic phased array technique to obtain ultrasonic images of electrofusion joints. Test sample joints have been designed and fabricated using artificial defects which were made using paper. Finally, we studied the condition of electrofusion in the field and analyzed the main causes of defects. And we classified the defect types as local lack of fusion, sand inclusion, voids or air inclusion, short stab, excess penetration or excess bead.

  • PDF

Clinical Outcomes of Percutaneous Endoscopic Laser Lumbar Discectomy (요추 추간판 탈출증에 대한 경피적 내시경 레이저 수핵 제거술 후 임상 결과)

  • Chang, Won Sok;Lee, Sang Ho
    • The Korean Journal of Pain
    • /
    • v.18 no.1
    • /
    • pp.34-38
    • /
    • 2005
  • Background: Over the years, disc surgery has progressively evolved in the direction of decreasing trauma and its invasiveness. Conventional open surgery has many complications, such as scarring, instability, bleeding and a relative high mortality rate. Minimally invasive spinal surgery is now an alternative to a traditional discectomy. Herein, we present an operative technique, and the early results, for a percutaneous endoscopic lumbar discectomy in herniated lumbar disc disease. Methods: 43 patients, including 27 men and 16 women, with ages ranging from 18 to 66 years, were enrolled in this study. All the patients showed a protruded or extruded soft disc herniation at the lumbar level on magnetic resonance imaging and computed tomography. A percutaneous endoscopic lumbar discectomy was applied to the patients, and clinical responses evaluated using MacNab's criteria. Results: 40 patients were regarded as showing successful responses (93.1%), and there were no severe complications, such as a hematoma, nerve injury, postoperative dysesthesia or death. One patient underwent fusion surgery for remnant back pain six month later. Conclusions: We conclude that, in properly selected patients, a percutaneous endoscopic lumbar discectomy is a safe, noninvasive and effective treatment modality for herniated lumbar intervertebral disc disease.

A retrospective study of incidental findings occurring in a consecutive case series of lateral cephalograms of 12- to 20-year-old patients referred for routine orthodontic treatment

  • MacDonald, David;Patel, Akash;Zou, Bingshuang;Yen, Edwin;Vora, Siddharth R.
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.295-302
    • /
    • 2022
  • Purpose: Lateral cephalograms of orthodontic patients may contain incidental findings that could potentially lead to harm. Materials and Methods: The lateral cephalograms of 1765 consecutive 12- to 20-year-old patients, being considered for routine orthodontic treatment, were retrospectively reviewed. These patients were considered normal, because no abnormalities were found either in their medical history or on their clinical examination. Results: The overall prevalence of incidental findings was 18.8%, of which 10.3% were ponticulus posticus and 4.2% were bridging of the sella turcica. Although occipital spurs and ponticulus posticus were more prevalent in males, the size of the sella turcicas did not differ between sexes. Of the 1156 patients completing treatment about 2 years later, only one lateral cephalogram displayed progression of the ponticulus posticus in that time. Conclusion: The prevalence of incidental findings on lateral cephalograms of otherwise normal orthodontic 12- to 20-year-old patients was almost a fifth, of which ponticulus posticus, vertebral fusion, and enlarged parietal foramina were clinically significant.

Bacterial Meningitis Complicated by Myelitis Following Anterior Cervical Spinal Surgery (전방 경추 수술 후 발생한 세균성 뇌수막염과 동반된 척수염)

  • Ham, Dong-Hun;Choi, Byeong-Yeol;Jung, Myung-Cheol
    • Journal of the Korean Orthopaedic Association
    • /
    • v.56 no.6
    • /
    • pp.519-524
    • /
    • 2021
  • Meningitis after spinal surgery occurs rarely but can be fatal. A 49-year-old male was diagnosed with compressive myelopathy due to cervical disc herniation at the C 5, 6 level and underwent anterior cervical discectomy and fusion (ACDF). He complained of severe neck pain and stiffness with fever postoperatively and one week after surgery, the patient presented with abrupt tetraplegia. The follow-up magnetic resonance imaging and cerebrospinal fluid analysis revealed bacterial meningitis complicated by myelitis. The patient was treated with antibiotics and steroid, but the outcome was poor. The authors report a case of meningitis combined with myelitis following anterior cervical spinal surgery.

Development of the Upper Wear Fixation Device for Chest AP X-ray Imaging on the Emergency Stretcher Bed (응급실 침대 위 흉부전후방향 엑스선 검사를 위한 상의고정장치 개발)

  • Lim, Woo-Taek;Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.205-211
    • /
    • 2022
  • This study aimed to provide basic data for 3D printing in the medical health field by developing upper wear fixation device (UWFD), an auxiliary device for shortening chest AP examination time on emergency room beds and non-contact with patients. The standard of hooks was modeled according to the bed frame using the Autodesk Fusion 360. It was printed with Form2 (Formlabs, Somerville, MA, USA), as SLA (stereo lithography apparatus) method, and was washed and hardened using Form Wash and Form Cure. The completed UWFD conducted an online survey on 4 items of stability, convenience, availability, preference and general characteristics. The total stability average was 3.93±0.80, the total convenience average was 3.93±0.68, the total availability average was 4.01±0.89, and the total preference average was 3.80±1.08. This study was significant in suggesting improvements in the general X-ray examination process in the emergency room by designing and making aids to easily fixing the patient's top to the frame of the emergency bed while meeting promptness and non-contact with the patient.

Revolutionizing Brain Tumor Segmentation in MRI with Dynamic Fusion of Handcrafted Features and Global Pathway-based Deep Learning

  • Faizan Ullah;Muhammad Nadeem;Mohammad Abrar
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.18 no.1
    • /
    • pp.105-125
    • /
    • 2024
  • Gliomas are the most common malignant brain tumor and cause the most deaths. Manual brain tumor segmentation is expensive, time-consuming, error-prone, and dependent on the radiologist's expertise and experience. Manual brain tumor segmentation outcomes by different radiologists for the same patient may differ. Thus, more robust, and dependable methods are needed. Medical imaging researchers produced numerous semi-automatic and fully automatic brain tumor segmentation algorithms using ML pipelines and accurate (handcrafted feature-based, etc.) or data-driven strategies. Current methods use CNN or handmade features such symmetry analysis, alignment-based features analysis, or textural qualities. CNN approaches provide unsupervised features, while manual features model domain knowledge. Cascaded algorithms may outperform feature-based or data-driven like CNN methods. A revolutionary cascaded strategy is presented that intelligently supplies CNN with past information from handmade feature-based ML algorithms. Each patient receives manual ground truth and four MRI modalities (T1, T1c, T2, and FLAIR). Handcrafted characteristics and deep learning are used to segment brain tumors in a Global Convolutional Neural Network (GCNN). The proposed GCNN architecture with two parallel CNNs, CSPathways CNN (CSPCNN) and MRI Pathways CNN (MRIPCNN), segmented BraTS brain tumors with high accuracy. The proposed model achieved a Dice score of 87% higher than the state of the art. This research could improve brain tumor segmentation, helping clinicians diagnose and treat patients.

Comparative Study on the Hydrogen Embrittlement Behavior of Additively Manufactured 316L Stainless Steel and CoCrFeNi Medium-Entropy Alloy (적층제조된 316L 스테인리스강 및 CoCrFeNi 중엔트로피 합금의 수소취화 거동 비교)

  • Jae Yeong Jung;Ji Yoon Jung;Dong-Hyun Lee
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.37 no.5
    • /
    • pp.237-246
    • /
    • 2024
  • In this study, hydrogen embrittlement was investigated for 316L stainless steel (SS316L) and CoCrFeNi medium-entropy alloy (MEA) fabricated by laser-powder bed fusion. The in-situ hydrogen charging tensile tests revealed that the reduction in ductility due to hydrogen was more significant in the CoCrFeNi MEA, compared to the SS316L. In the case of SS316L, hydrogen-assisted cracks (HACs) were observed mainly on the surface, whereas in CoCrFeNi, cracks were found not only at the edges but also in the central region. HACs analysis confirmed that transgranular (TG) cracks were predominant in SS316L, whereas only intergranular cracks were formed in the CoCrFeNi MEA. The difference in hydrogen embrittlement resistance between SS316L and CoCrFeNi was discussed in terms of the differences in deformation microstructure and hydrogen diffusivity, as investigated through electron channeling contrast imaging and nanoindentation.

Usefulness of "Volumetrix Suite" with SPECT/CT (SPECT/CT 영상에서 Volumetrix Suite의 유용성)

  • Cho, Seung-Wook;Shin, Byeong-Ho;Kim, Jong-Pil;Yoon, Seok-Hwan;Kim, Tae-Yeub;Seung, Yong-Joon;Moon, Il-Sang;Woo, Jae-Ryong;Lee, Ho-Young
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.166-171
    • /
    • 2010
  • Purpose: The SPECT/CT is able to acquire diagnostic information resolved the difficult problems that discriminate regions of focals by intergrating functional images and anatomical images. We introduce the usefulness of "Volumetrix Suite" which can describe 3D images by the convergence of the SPECT/CT images and reference CT images. Materials and Methods: We applied Volumetrix Suite program (Volumetrix IR, Volumetrix 3D) to patients, Bone, Venography, Parathyroid, WBC, taken diagnostic CT examination which have same regions of focal in Seoul Metropolitan Government Seoul National University Boramae Medical Center. After acquiring SPECT/CT images and reference CT images, we fused a couple of scans applying for this programs. The CT scan of Infinia Hawkeye 4 shows limitation of anatomical information. For this reason, we tried to transfer CT images that have lots of diagnostic informations as the form of Dicom file in PACS, and changed from 2D images to 3D images after image registering in Xeleris Workstaion of Hawkeye 4. Results & Conclusion: By using Volumetrix Suite program, we're able to acquire more accurate anatomical informations with 3D rendering which can distinguish both location and range of focals in Infinia Hawkeye 4. Thus, the result of utilizing this program indicate that nuclear medicine anatomical images can be improved by providing more diagnostic imformations produced by its program.

  • PDF

The Fabricating and Utilizing of the Transmission Scan Tool for I-131 Whole Body Scan (I-131 전신 스캔을 위한 Transmission Scan Tool 제작과 활용)

  • Shin, Chae-Ho;Pyo, Sung-Jai;Kim, Bong-Su;Cho, Yong-Gyi;Jo, Jin-Woo;Kim, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.40-46
    • /
    • 2009
  • Purpose: A whole body scan using a radioactive iodine (I-131) for the patients with differentiated thyroid cancer is generally an useful method to detect the remnant thyroid tissue, recurred lesion or metastasis lesion after a surgery. The high dose treatment using the radioactive iodine recently tends to increase, and a hospitalization wait for the treatment has been delayed for several months. In this hospital, the treatable patients per week were increased in number through expanding a water-purifier tank and the examination time also increased as the I-131 whole body scan patients increased. Improvement for this problem, this research reduce the existing examination time and classifying the lesion's exact position intended to by fabricating and utilizing the transmission scan tool and an excellent resolution for whole body imaging. Materials and Methods: After conducting the whole body scan for patients who visited the department from February to July 2008 and received the I-131 whole body scan using the ORBITER Gamma Camera. A rail was installed in the examination table for the transmission scan for show a contour of surface area and then the transmission image was obtained and fused to the whole body scan through fabricating the tool to put a flood phantom of diluted 2 mCi $^{99m}Tc$-pertechnetate. Results: Fused image of I-131 whole body scan and the transmission scan had the excellent resolution to discriminate an oral cavity or salivary gland region, neck region's lesion, and metastasis region's position through a simple marking, and could reduce the examination time of 8~28 minutes because without the additional local image. Conclusions: In I-131 whole body scan, the transmission scan can accurately show a contour of surface area through the attenuation of radioactivity, and is useful to indicate the remnant thyroid tissue or metastasis lesion's position by improving the resolution through the fusion image with alreadyexecuted I-131 whole body scan. Also, because the additional local image is not necessary, it can reduce the time required for the examination. It will extensively apply to other clinical examinations to be helpful for identifying an anatomical position because it shows the contour of surface area.

  • PDF