• 제목/요약/키워드: Fusion device

검색결과 294건 처리시간 0.026초

무접점스위치(SSR) 발열 방지 장치 개발에 대한 연구 (A Study on Developmemt of Heat-Emission Prevention Device for SSR)

  • 이만수;김준용;김진배
    • 대한안전경영과학회지
    • /
    • 제21권4호
    • /
    • pp.25-30
    • /
    • 2019
  • Electric of using in daily life is always exposed to risk of electrical fire and electric shock. Only degree of risk is different, there is no risk free electrical product. Generally, the higher voltage, the risk of electric shock is high. The much electric current, the risk of electrical fire is high. But, we can't help using electric because of risk and we effort to reduce the risk of electrical fire and electric shock. This study deal with the fire prevention generated on heating equipment using SSR for current.

UV 개질된 PMMA 미세유체 장치의 열가소성 폴리머 용융 접합 (Thermoplastic Fusion Bonding of UV Modified PMMA Microfluidic Devices)

  • 박태현
    • 한국정밀공학회지
    • /
    • 제31권5호
    • /
    • pp.441-449
    • /
    • 2014
  • Thermoplastic fusion bonding is widely used to seal polymer microfluidic devices and optimal bonding protocol is required to obtain a successful bonding, strong bonding force without channel deformation. Besides, UV modification of the PMMA (poly-methyl methacrylate) is commonly used for chemical or biological application before the bonding process. However, study of thermal bonding for the UV modified PMMA was not reported yet. Unlike pristine PMMA, the optimal bonding parameters of the UV modified PMMA were $103^{\circ}C$, 71 kPa, and 35 minutes. A very low aspect ratio micro channel (AR=1:100, $20{\mu}m$ depth and $2000{\mu}m$ width) was successfully bonded (over 95%, n>100). Moreover, thermal bonding of multi stack PMMA chips was successfully demonstrated in this study. The results may applicable to fabricate a complex 3 dimensional microchannel networks.

세포 전기 융합 감지 장치에 관한 연구 (Development of System For Cell Fusion Detection)

  • 권기진;김민수;박세광
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 C
    • /
    • pp.1336-1338
    • /
    • 1994
  • Cell fusion device is an artificial equipment which fuses electrically two types of cells fed from the respective micropump to the fusion chamber by electric pulses. In this case, the detective sensor of flowing cell, along with passage, is required to control the time of pulses applied to cell and the injection of cells which are fed from inlet to micropump. There are two methods of detection of flowing cell; optical, impedance method. The difference of output for optical sensor is about 426mV for 805nm wavelength. about 37mV for 665nm wavelength. In impedance method, sensor output is 132.33mV at middle point and 117.10mV at edge point in the channel. Experimental results show that the optimal frequency range of sensor output is Iron 50Hz to 400Hz.

  • PDF

전자석 구조물용 적층 유리섬유강화 복합재료의 기계적 특성 (Mechanical Properties of the Laminated Glass Fiber-Reinforced Plastic Composites for Electromagnet Structure System)

  • 박한주;김학근;송준희
    • 대한금속재료학회지
    • /
    • 제49권8호
    • /
    • pp.589-595
    • /
    • 2011
  • Laminated glass fiber-reinforced plastic (GFRP) composites were applied to an insulating structure of a magnet system for a nuclear fusion device. Decreased inter-laminar strength by a strong repulsive force between coils which is induced a problem of structural integrity in laminated GFRPs. Therefore, it is important to investigate the inter-laminar characteristics of laminated GFRP composites in order to assure more reliable design and better structural integrity. Three types of the laminated GFRP composites using a high voltage insulating materials were fabricated according to each molding process. To evaluate the grade of the fabricated composites, mechanical tests, such as hardness, tensile and compressive tests,were carried out. The autoclave molding composites satisfied almost of the mechanical properties reguested at the G10 class standard, but the vacuum impregnation (VPI) and Prepreg composites did not.

OVERVIEW OF KSTAR INTEGRATED CONTROL SYSTEM

  • Park, Mi-Kyung;Kim, Kuk-Hee;Lee, Tae-Gu;Kim, Myung-Kyu;Hong, Jae-Sic;Baek, Sul-Hee;Lee, Sang-Il;Park, Jin-Seop;Chu, Yong;Kim, Young-Ok;Hahn, Sang-Hee;Oh, Yeong-Kook;Bak, Joo-Shik
    • Nuclear Engineering and Technology
    • /
    • 제40권6호
    • /
    • pp.451-458
    • /
    • 2008
  • After more than 10 years construction, KSTAR (Korea Superconducting Tokamak Advanced Research) had finally completed its assembly in June 2007, and then achieved the goal of first-plasma in July 2008 through the four month's commissioning. KSTAR was constructed with fully superconducting magnets with material of $Nb_3Sn$ and NbTi, and their operation temperatures are maintained below 4.5K by the help of Helium Refrigerator System. During the first-plasma operation, plasmas of maximum current of 133kA and maximum pulse width of 865ms were obtained. The KSTAR Integrated Control System (KICS) has successfully fulfilled its missions of surveillance, device operation, machine protection interlock, and data acquisition and management. These and more were all KSTAR commissioning requirements. For reliable and safe operation of KSTAR, 17 local control systems were developed. Those systems must be integrated into the logically single control system, and operate regardless of their platforms and location installed. In order to meet these requirements, KICS was developed as a network-based distributed system and adopted a new framework, named as EPICS (Experimental Physics and Industrial Control System). Also, KICS has some features in KSTAR operation. It performs not only 24 hour continuous plant operation, but the shot-based real-time feedback control by exchanging the initiatives of operation between a central controller and a plasma control system in accordance with the operation sequence. For the diagnosis and analysis of plasma, 11 types of diagnostic system were implemented in KSTAR, and the acquired data from them were archived using MDSpius (Model Driven System), which is widely used in data management of fusion control systems. This paper will cover the design and implementation of the KSTAR integrated control system and the data management and visualization systems. Commissioning results will be introduced in brief.

Development of machine learning model for automatic ELM-burst detection without hyperparameter adjustment in KSTAR tokamak

  • Jiheon Song;Semin Joung;Young-Chul Ghim;Sang-hee Hahn;Juhyeok Jang;Jungpyo Lee
    • Nuclear Engineering and Technology
    • /
    • 제55권1호
    • /
    • pp.100-108
    • /
    • 2023
  • In this study, a neural network model inspired by a one-dimensional convolution U-net is developed to automatically accelerate edge localized mode (ELM) detection from big diagnostic data of fusion devices and increase the detection accuracy regardless of the hyperparameter setting. This model recognizes the input signal patterns and overcomes the problems of existing detection algorithms, such as the prominence algorithm and those of differential methods with high sensitivity for the threshold and signal intensity. To train the model, 10 sets of discharge radiation data from the KSTAR are used and sliced into 11091 inputs of length 12 ms, of which 20% are used for validation. According to the receiver operating characteristic curves, our model shows a positive prediction rate and a true prediction rate of approximately 90% each, which is comparable to the best detection performance afforded by other algorithms using their optimized hyperparameters. The accurate and automatic ELM-burst detection methodology used in our model can be beneficial for determining plasma properties, such as the ELM frequency from big data measured in multiple experiments using machines from the KSTAR device and ITER. Additionally, it is applicable to feature detection in the time-series data of other engineering fields.

SCBF 장치에서 이온전류에 대한 포텐셜 우물 구조의 영향 (Effect of Potential Well Structure on Ion Current in SCBF Device)

  • 주흥진;박정호;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제20권5호
    • /
    • pp.471-477
    • /
    • 2007
  • SCBF(Spherically Convergent Beam Fusion) device has been studied as a neutron source. Neutron production rate is a most important factor for the application of SCBF device and is proportional to the square of the ion current[1]. It is regarded generally that some correlations between the potential well structure and the ion current exist. In this paper, the ion current and potential distribution were calculated in a variety of grid cathode geometries using FEM-FCT method. Single potential well structure was certified inside the grid cathode. The deeper the potential well became, the higher the ion current due to the high electric field near the grid cathode became.

SCBF 장치에서 그리드 음극 구조의 영향에 대한 입자 시뮬레이션 (Particle Simulation on the Effect of Grid Cathode Geometry in SCBF Device)

  • 주흥진;박정호;고광철
    • 한국전기전자재료학회논문지
    • /
    • 제20권8호
    • /
    • pp.742-747
    • /
    • 2007
  • In 2-dimensional SCBF (Spherically Convergent Beam Fusion) device, the effect on neutron production rate of the grid cathode geometry was simulated. The motion of Particles was tracked using Monte Carlo Method including the atomic and molecular collision processes and potential distribution was calculated by Finite Element Method, Main processes of the discharge were the ionization of $D_2$ by fast $D_2^+\;ion$. As the number of cathode rings was small and the size of grid cathode decreased, the ion current increased and neutron production rate will also increase. The star mode discharge which is a very important characteristic in SCBF device, was confirmed by the ionization position.

산업용 모바일 융합단말 플랫폼 구조 설계 (Architecture Design of Smart Mobile Platform for Industry)

  • 박종원
    • 한국정보통신학회:학술대회논문집
    • /
    • 한국해양정보통신학회 2011년도 추계학술대회
    • /
    • pp.765-768
    • /
    • 2011
  • 현재 스마트 모바일 기기들이 출시되어 융합성, 이동성, 편의성이 사용자들로부터 큰 호응을 받고 있다. 한편, 산업계에서도 처리하여야 할 정보가 점차 많아짐에 따라 복잡한 정보를 처리할 수 있는 모바일 기기가 요구되고 있다. 이에 본 논문에서는 이러한 요구사항들을 반영한 산업용 스마트 모바일 패드의 구조를 설계하고, 그 응용분야들에 대해 고찰해 본다.

  • PDF

A Prospective, Multi-Center, Double-Blind, Randomized Study to Evaluate the Efficacy and Safety of the Synthetic Bone Graft Material DBM Gel with rhBMP-2 versus DBM Gel Used during the TLIF Procedure in Patients with Lumbar Disc Disease

  • Hyun, Seung-Jae;Yoon, Seung Hwan;Kim, Joo Han;Oh, Jae Keun;Lee, Chang-Hyun;Shin, Jun Jae;Kang, Jiin;Ha, Yoon
    • Journal of Korean Neurosurgical Society
    • /
    • 제64권4호
    • /
    • pp.562-574
    • /
    • 2021
  • Objective : This study is to evaluate the efficacy and safety of demineralized bone matrix (DBM) gel versus DBM gel with recombinant human bone morphogenetic protein-2 (rhBMP-2) used in transforaminal lumbar interbody fusion (TLIF). Methods : This study was designed as a prospective, multi-center, double-blind method, randomized study. All randomized subjects underwent TLIF with DBM gel with rhBMP-2 group (40 patients) as an experimental group or DBM gel group (36 patients) as a control group. Post-operative observations were performed at 12, 24, and 48 weeks. The spinal fusion rate on computed tomography scans and X-rays films, Visual analog scale pain scores, Oswestry disability index and SF-36 quality of life (QOL) scores were used for the efficacy evaluation. The incidence rate of adverse device effects (ADEs) and serious adverse device effects (SADEs) were used for safety evaluation. Results : The spinal fusion rate at 12 weeks for the DBM gel with rhBMP-2 group was higher with 73.68% compared to 58.82% for the DBM gel group. The 24 and 48 weeks were 72.22% and 82.86% for the DBM gel with rhBMP-2 group and 78.79% and 78.13%, respectively, for the DBM gel group. However, there were no significant differences between two groups in the spinal fusion rate at 12, 24, and 48 weeks post-treatment (p=0.1817, p=0.5272, p=0.6247). There was no significant difference between the two groups in the incidence rate of ADEs (p=0.3836). For ADEs in the experimental group, 'Pyrexia' (5.00%) was the most common ADE, followed by 'Hypesthesia', 'Paresthesia', 'Transient peripheral paralysis', 'Spondylitis' and 'Insomnia' (2.50%, respectively). ADEs reported in control group included 'Pyrexia', 'Chest discomfort', 'Pain', 'Osteoarthritis', 'Nephropathy toxic', 'Neurogenic bladder', 'Liver function analyses' and 'Urticaria' (2.86%, respectively). There was no significant difference between the two groups in the incidence rate of SADEs (p=0.6594). For SADE in the experimental group, ''Pyrexia' and 'Spondylitis' were 2.50%. SADE reported in the control group included 'Chest discomfort', 'Osteoarthritis' and 'Neurogenic bladder'. All SADEs described above were resolved after medical treatment. Conclusion : This study demonstrated that the spinal fusion rates of DBM gel group and DBM gel with rhBMP-2 group were not significantly different. But, this study provides knowledge regarding the earlier postoperative effect of rhBMP-2 containing DBM gel and also supports the idea that the longer term follow-up results are essential to confirm the safety and effectiveness.