• Title/Summary/Keyword: Fuse and Relay

Search Result 14, Processing Time 0.022 seconds

Implementation of Vision System combining Character and Color Recognition (문자 및 색 인식을 혼용한 검사시스템의 구현)

  • Yang, Woo-Suk
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.16 no.1
    • /
    • pp.221-225
    • /
    • 2016
  • This paper is about vision system that exhibits automatic examination of the conditions of fuses and relay boxes using a camera. Proposed vision system is composed of three parts: image acquisition, vision algorithm, and user interface. The image acquisition part is composed of illumination and optics. The vision algorithmis the examining part, using the grabbed fuse box image. Lastly, user interface is divided into two parts, user interface for registering features of fuse box and user interface for examination operation.

The Study of FUSE Installing of PT in the trend of Digitalization and Convergence of Power Machinery. (디지탈화 및 복합화된 전력기기 변성기용 퓨즈 설치의 문제점)

  • Ok Yeon Ho;Lee Hyoung Mook;Hong Yeong Jae;Lee Eun Woong
    • Proceedings of the KIEE Conference
    • /
    • summer
    • /
    • pp.357-359
    • /
    • 2004
  • Fuse is the initial equipment of Protective Relay The installation standard of Fuse has been used for long time in Power Facilities. However according to the innovative development of Electric & Electronic element(=semiconductor) Technology, Protective Relay and other Power Equipments are being changed into Digitalization and Multi-Functional Convergence. In contrast with it, the installation standard of Fuse is just the same. There is a need to give careful consideration to it. This study will bear a Part of producing a safe and efficient Power by examining the current installation of primal 8f secondary 1'use in multi-functional PT of Power plant, giving a problem careful consideration and suggesting suitable countermeasures.

  • PDF

The Analysis of the LCL Set-up Parameters for Satellite Power Distribution (위성전원분배를 위한 LCL 동작 파라미터 설정분석)

  • Lim, Seong-Bin;Jeon, Hyun-Jin;Kim, Kyung-Soo;Kim, Tae-Youn
    • Aerospace Engineering and Technology
    • /
    • v.10 no.2
    • /
    • pp.56-64
    • /
    • 2011
  • In this paper, the characteristics of LCL set-up parameters for the satellite load distribution are analyzed under the electrical system environment, implemented the LCL circuits and evaluated the performance and its behaviour. Recently, it is implemented the load distribution circuit by latching current limiter(LCL) rather than conventional fuse and relay for the protection of the satellite power system from a fault load. The LCL circuit is composed of the electrical components, not mechanical parts with the fuse and relay. When detected the over current on a fault load, it is activated to maintain the trip-off level for set-up time and then cut-off the load power by the active control. It is more flexible and provided a chance to reuse of the load in case of temporarily event, but the fuse and relay can't be used again after activating due to the physical disconnection. However, for implementation of LCL circuit, it should be carefully considered the behavior of the LCL circuit under the worst electrical system environment and applied it to define the set-up parameters related with over-current inhibition.

Development of Computer Program for Relay Coordination (계전시스템의 보호협조를 위한 컴퓨터 프로그램 개발)

  • Kim, Nam-Ho
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.437-439
    • /
    • 1991
  • This paper deals with the development of computer programs that can be used for fuse and relay coordination in power station and also with the characteristics of these protective devices. The coordination of protective devices is determined by caculation from the lowest voltage level back to the power source. The minimum time difference between two different characteristics on the time- current curves is determined by the Golden Section searching routine.

  • PDF

Implementation of a DCS Terminal Remote Monitoring System using Wire and Wireless Communication (유무선 통신을 이용한 DCS 터미널 원격 감시 시스템 구현)

  • Baek, Yeong-Tae;Lee, Se-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.12 no.3
    • /
    • pp.267-275
    • /
    • 2007
  • In this paper, we designed and implemented DCS terminal remote monitoring middleware for real-time auditor and management terminal status signal with relay and fuse status at power management room. The middleware consist of four component as event analyzer, event manager, service manager and user interface. We expected economic effects extend relay life-time that pre-detected errors and prevented relay fault.

  • PDF

Design and Implementation of DCS Terminal Remote Monitoring Board using Wire and Wireless Communication (유무선 통신을 이용한 DCS 터미널 원격 감시 보드 설계 및 구현)

  • KPark, Hae-Dong;Kang, Jeon-Wook;Kim, Jae-Hwan;Lee, Se-Hoon
    • KSCI Review
    • /
    • v.14 no.2
    • /
    • pp.117-122
    • /
    • 2006
  • In this paper, we designed and implemented the DCS(Distributed Control System) terminal remote monitoring board for build total unified management system based wireless communication on automatic control system fields. Also, it tested and evaluated for check an usability and performance. The board monitored relay and fuse status at power management room real-time. Therefore, we expected economic effects extend relay life-time that pre-detected errors and prevented relay fault.

  • PDF

Automated Visual Inspection System of Junction Box using Color Inspection and Template Matching (색상 검사와 템플릿 매칭을 이용한 정션 박스 자동 시각 검사 시스템)

  • Park, Byung-Joon;Hahn, Kwang-Soo;Lee, Ho-Jun
    • Journal of Korea Multimedia Society
    • /
    • v.13 no.3
    • /
    • pp.392-399
    • /
    • 2010
  • The Automobile has developed and changed through the years from the invention and increased human-being's scope of activity. Junction Box, one of the part of automobile, is inspected by human eyes which caused mistakes and slow progress. To achieve the speed and accuracy the system was compensated by vision system which is inspecting automatically. This paper is automatic inspection of fuse and relay which is inserted in the junction box by checking the color and pattern of the cover. After checking the performance of the system by using the junction box, the result was 100 percent perception and open the possibility to inspect junction box fast and easy and accurate if it is applied to the industry.

COMS EPS PRELIMINARY DESIGN

  • Koo, Ja-Chun;Kim, Eui-Chan
    • Proceedings of the KSRS Conference
    • /
    • v.1
    • /
    • pp.220-223
    • /
    • 2006
  • The COMS(Communication, Ocean and Meteorological Satellite) EPS(Electrical Power Subsystem) is derived from an enhanced Eurostar 3000 EPS which is fully autonomous operation in normal conditions or in the event of a failure and provides a high level of reconfiguration capability and flexibility. This paper introduces the COMS EPS preliminary design result. The COMS EPS consists of a battery, a solar array wing, a PSR(Power Supply Regulator), a PRU(Pyrotechnic Unit), a SADM(Solar Array Drive Mechanism) and relay and fuse brackets. This can offer a bus power capability of 3 kW. The solar array is made of a deployable wing with two panels. One type of solar cells is selected as GaAs/Ge triple junction cells. Li-ion battery is base lined with ten series cell module of five cells in parallel. PSR associated with battery and solar array generates a power bus fully regulated 50 V. Power bus is centralised protection and distribution by relay and fuse brackets. PRU provides power for firing actuators devices. The solar array wing is routed by the SADM under control of the AOCS(Attitude Orbit Control Subsystem). The control and monitoring of the EPS especially of the battery, is performed by the PSR in combination with on-board software.

  • PDF

Implementation of a DCS Terminal Remote Monitoring Middleware using RF Communication (RF 통신을 이용한 DCS 터미널 원격 감시 미들웨어 구현)

  • Ha, Jong-Hyun;Choi, Seong-Kyou;Rho, Ju-Yong;Jung, Heon-Man;Lee, Se-Hoon
    • KSCI Review
    • /
    • v.14 no.2
    • /
    • pp.129-134
    • /
    • 2006
  • In this paper, we designed and implemented DCS terminal remote monitoring middleware for real-time auditor and management terminal status signal with relay and fuse status at power management room. The middleware consist of four component as event analyzer, event manager, service manager and user interface. We expected economic effects extend relay life-time that pre-detected errors and prevented relay fault.

  • PDF

The plan for fault coordination improvement of underground distribution line (지중 배전선로의 보호협조 개선방안)

  • Ha, Bok-Mam;Yoon, Tae-Sang;Ilm, Seong-Il;Kang, Mun-Ho;Jeong, Chang-Soo;Lee, Heung-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2001.05a
    • /
    • pp.132-135
    • /
    • 2001
  • To improve the fault coordination of underground distribution line we study the several contents such as the magnitude of fault current in distribution line tripping time of CB by acting of over current relay with instantaneous trip and time delay trip. We also examine the melting time of current limiting fuse inside power fuse Through the research as above. we suggest the modification scheme of fault coordination to reduce the interruption times of power failure.

  • PDF