• 제목/요약/키워드: Functional sensitivity

검색결과 363건 처리시간 0.04초

전기화학적 노이즈 저항 측정에서의 불확도 평가 (Uncertainty evaluation in electrochemical noise resistance measurement)

  • 김종집;강수연
    • Corrosion Science and Technology
    • /
    • 제12권5호
    • /
    • pp.220-226
    • /
    • 2013
  • The uncertainty in statistical noise resistance measurement was evaluated for a type 316 stainless steel in NaCl solutions at room temperature. Sensitivity coefficients were determined for measurands or variables such as NaCl concentration, pH, solution temperature, surface roughness, inert gas flow rate and bias potential amplitude. The coefficients were larger for the variables such as NaCl concentration, pH, inert gas flow rate and solution temperature, and they were the major factors increasing the combined standard uncertainty of noise resistance. However, the contribution to the uncertainty in noise resistance measurement from the above variables was remarkably low compared to that from repeated measurements of noise resistance, and thus, it is difficult to lower the uncertainty in noise resistance measurement significantly by lowering the uncertainties related with NaCl concentration, pH, inert gas flow rate and solution temperature. In addition, the uncertainty in noise resistance measurement was high amounting to 17.3 % of the mean, indicating that the reliability in measurement of noise resistance is low.

전도성 고분자가 첨가된 생체 모방형 분자 각인 고분자 테르펜 센서 (Biomimetic MIP Terpene Sensors Adding Conductive Polymers)

  • 정재훈;이성필
    • 센서학회지
    • /
    • 제21권5호
    • /
    • pp.345-351
    • /
    • 2012
  • Biomimetic terpene sensors which have high sensitivity and stability have been fabricated using moleculary imprinted polymer (MIP) technology. Since it is impossible to make a resistive type sensor due to the high resistance of MIP, we improved the sensor by adding conductive polymers. We investigated the sensitivity of resistive type sensors with nano particles depending on the amount of conductive polymers. The MIP membrane contained the methacrylic acid as functional monomer and ethylene glycol dimethacrylate as cross linker, which formed specific cavities originated by the target terpene molecules. The mixture of MIP and the conductive polymer was coated on the patterns of interdigit electrodes on the alumina substrate. The fabricated sensors showed their highest specific sensitivities exposed to 500 ppm target gases : limonene 0.055 at 40% of amount of conductive polymers and geraniol $5.84{\times}10^{-4}$ at 20% of amount of conductive polymers. In conclusion, we found that the terpene sensors are affected by the target molecules, functional monomers and the conductive polymers.

Design Criteria to Miniaturize the Single Use Functional Respiratory Air Flow Tube

  • Kim Kyung Ah;Lee Tae Soo;Cha Eun Jong
    • 대한의용생체공학회:의공학회지
    • /
    • 제26권3호
    • /
    • pp.163-169
    • /
    • 2005
  • Respiratory tubes with a length of 35mm and diameters of 10, 15, and 20mm were made for experimental purpose, and both the static$(P_s)\;and\;dynamic(P_D)$ pressures were simultaneously measured for steady flow rates ranging 1-12//sec. Least squares analysis resulted successful fitting of $P_s\;and\;P_D$ data with quadratic equations with correlation coefficients higher than 0.99(P<0.0001). The spirometric measurement standards of the American Thoracic Society(ATS) were applied to $P_s$ data, which demonstrated the smallest tube diameter of 15mm to satisfy the ATS standards. The maximum $P_D$ value of the velocity type transducer(the functional single use respiratory air flow tube) with the diameter of 15mm was estimated to be approximately $75cmH_2O$, implying more than 7 times larger sensitivity than the widely used pneumotachometers. These results showed that the velocity type respiratory air flow transducer is a unique device accomplishing miniaturization with the sensitivity increased, thus would be of great advantage to develop portable medical devices.

Sensitivity Alterable Biosensor Based on Gated Lateral BJT for CRP Detection

  • Yuan, Heng;Kang, Byoung-Ho;Lee, Jae-Sung;Jeong, Hyun-Min;Yeom, Se-Hyuk;Kim, Kyu-Jin;Kwon, Dae-Hyuk;Kang, Shin-Won
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • 제13권1호
    • /
    • pp.1-7
    • /
    • 2013
  • In this paper, a biosensor based on a gated lateral bipolar junction transistor (BJT) is proposed. The gated lateral BJT can function as both a metal-oxide-semiconductor field-effect transistor (MOSFET) and a BJT. By using the self-assembled monolayer (SAM) method, the C-reactive protein antibodies were immobilized on the floating gate of the device as the sensing membrane. Through the experiments, the characteristics of the biosensor were analyzed in this study. According to the results, it is indicated that the gated lateral BJT device can be successfully applied as a biosensor. Additionally, we found that the sensitivity of the gated lateral BJT can be varied by adjusting the emitter (source) bias.

Sensing Characteristics of Uncoated Double Cladding Long-period Fiber Grating Based on Mode Transition and Dual-peak Resonance

  • Zhou, Yuan;Gu, Zheng Tian;Ling, Qiang
    • Current Optics and Photonics
    • /
    • 제5권3호
    • /
    • pp.243-249
    • /
    • 2021
  • In this paper, the sensing characteristics of a double cladding fiber (DCF) long-period fiber grating (LPFG) to the surrounding refractive index (SRI) are studied. The outer cladding of the DCF plays the role of the overlay, thus, the mode transition (MT) phenomenon of DCF can be induced by etching the outer cladding radius instead of coating overlays. The response characteristics of the effective refractive index (ERI) of the cladding mode to the outer cladding radius are analyzed. It is found that in the MT range, the change rate of ERIs of cladding modes is relatively larger than that for other ranges. Further, based on the features of the mode transition region (MTR), the phase-matching curve of the 11th cladding mode is investigated, and the response of the DCF-LPFG to the SRI is characterized by the change of wavelength intervals between the dual peaks under different outer cladding radii. The numerical simulation results show that the SRI sensitivity is greatly improved, which is available to 3484.0 nm/RIU with the fitting degree 0.998 in the SRI range of 1.33-1.37. The proposed DCF-LPFG can provide new theoretical support for designing the DCF-LPFG refractive index sensor with excellent performances of sensitivity, linearity and structure.

자기제시와 브랜드 선호도의 관계에서 체면민감성과 사용상황의 조절효과 (Moderating Effects of Chemyon(Social Face) and Consumption Situation in the Relationship between Self-Presentation and Brand Preference)

  • 정보라;김미정;윤지현;이주화;한지수;이성수
    • 미래기술융합논문지
    • /
    • 1권1호
    • /
    • pp.15-24
    • /
    • 2022
  • 본 논문은 자기제시와 브랜드 선호도의 관계에서 체면민감성과 사용상황의 조절효과를 알아보고자 하였다. 충남지역에 소재한 대학교의 학생들을 대상으로 자료를 수집하였다. 분석결과는 다음과 같이 요약될 수 있다. 우선 공적 사용 상황에서든 사적 사용상황에서든 상징적 브랜드 선호도에 대한 자기제시의 효과는 유의하지 않았다. 반면, 두 가지 상황 모두에서 기능적 브랜드 선호도에 대한 자기제시의 영향은 유의한 것으로 나타났다. 둘째, 체면민감성의 주효과는 공적 상황에서 기능적 브랜드 선호도에 부적인 영향을 미칠 때만 유의할 뿐 다른 경우에는 유의하지 않았다. 셋째, 자기제시와 체면민감성의 상호작용효과를 보면, 공적 상황에서든 사적 상황에서든 체면에 대한 민감성이 상대적으로 낮은 사람들은 자기제시 수준과 무관하게 브랜드 선호도의 변화가 크게 나타나고 있지 않았다. 본 연구는 사용 상황이 공적이든 사적이든 체면민감성은 자기제시와 상호작용을 통하여 브랜드 선호도에 영향을 미침을 밝히고 있다는 점에서 의의를 찾을 수 있다.

Optical Flow for Motion Images with Large Displacement by Functional Expansion

  • Kim, Jin-Woo
    • 한국멀티미디어학회논문지
    • /
    • 제7권12호
    • /
    • pp.1680-1691
    • /
    • 2004
  • One of the representative methods of optical flow is a gradient method which estimates the movement of an object based on the differential of image brightness. However, the method is ineffective for large displacement of the object and many improved methods have been proposed to copy with such limitations. One of these improved techniques is the multigrid processing, which is used in many optical flow algorithms. As an alternative novel technique we have been proposing an orthogonal functional expansion method, where whole displacements are expanded from low frequency terms. This method is expected to be applicable to flow estimation with large displacement and deformation including expansion and contraction, which are difficult to cope with by conventional optical flow methods. In the orthogonal functional expansion method, the apparent displacement field is calculated iteratively by a projection method which utilizes derivatives of the invariant constraint equations of brightness constancy. One feature of this method is that differentiation of the input image is not necessary, thereby reducing sensitivity to noise. In this paper, we apply our method to several real images in which the objects undergo large displacement and/or deformation including expansion. We demonstrate the effectiveness of the orthogonal functional expansion method by comparing with conventional methods including our optimally scaled multigrid optical flow algorithm.

  • PDF

A Quinoline-thiooxorhodamine Conjugate for Fluorescent Hg2+ Recognition in Aqueous Media and Living Cells

  • Tang, Lijun;Wen, Xin;Dai, Xin;Wu, Di;Huang, Zhenlong
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권11호
    • /
    • pp.3326-3330
    • /
    • 2014
  • A quinoline-thiooxorhodamine conjugate fluorescent sensor (1) has been synthesized. Sensor 1 exhibits high selectivity and sensitivity to $Hg^{2+}$ in $H_2O$/DMSO (95/5, v/v, HEPES 20 mM, pH = 7.4) solution with fluorescence detection. Other tested metal ions do not induce any significant fluorescence intensity changes. Sensor 1 interacts with $Hg^{2+}$ through a 1:1 binding stoichiometry with a good anti-inference ability. In addition, fluorescent imaging of $Hg^{2+}$ in Hela cells is also successfully demonstrated.

A Simple Benzimidazole Based Fluorescent Sensor for Ratiometric Recognition of Zn2+ in Water

  • Zhong, Keli;Cai, Mingjun;Hou, Shuhua;Bian, Yanjiang;Tang, Lijun
    • Bulletin of the Korean Chemical Society
    • /
    • 제35권2호
    • /
    • pp.489-493
    • /
    • 2014
  • A phenylbenzimidazole derivatized sensor (L) that behaves as a ratiometric fluorescent receptor for $Zn^{2+}$ in water has been described. In HEPES buffer at pH 7.4, sensor L displays a weak fluorescence emission band at 367 nm. Upon addition of $Zn^{2+}$, the emission intensity at 367 nm is decreased, concomitantly, a new emission band centered at 426 nm is developed, thus facilitates a ratiometric $Zn^{2+}$ sensing behavior. Sensor L binds $Zn^{2+}$ through a 1:1 binding stoichiometry with high selectivity over other metal cations. Sensor L displays a linear response to $Zn^{2+}$ concentration from 0 to $6.0{\times}10^{-5}M$, sensor L also exhibits high sensitivity to $Zn^{2+}$ with a detection limit of $3.31{\times}10^{-7}M$.