• Title/Summary/Keyword: Functional Insole

Search Result 31, Processing Time 0.024 seconds

Effects of Functional Insole Application Using the Hallux Point on Dynamic Balance (할룩스 포인트를 이용한 기능성 인솔 착용 시 동적균형에 미치는 영향)

  • Su-Kyoung Lee;Im-Rak Choi
    • PNF and Movement
    • /
    • v.22 no.2
    • /
    • pp.267-274
    • /
    • 2024
  • Purpose: The purpose of this study was to determine the effects of functional insole application using a hallux point on dynamic balance. Methods: Twenty-nine participated in this study. The experiment investigated changes in dynamic balance with the use of a functional insole that emphasized the hallux point. After explaining the experiment to the subjects, the Y-balance test was conducted to measure dynamic balance before the insole was applied. The test was then repeated after the functional insole with the hallux point was. Paired t-tests were used to analyze the statistical differences before and after the application of the functional insole with the hallux point. Results: The functional insole that emphasizes the hallux point significantly increased the distance in the anterior (p<0.05), posteromedial (p<0.05), posterolateral (p<0.05) directions as well as the composite score measured by the Y-balance test compared to before the insole application. Conclusion: The use of a functional insole that emphasizes the hallux point can help the foot pronate during dynamic balance, thereby improving balance through the control of the sole.

Effects of Foot Strengthening Exercises and Functional Insole on Range of Motion and Foot Plantar Pressure in Elderly Women

  • Shin, Jin Hyung;Lee, Joong Sook;Han, Ki Hoon;Bae, Kang Ho
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.1
    • /
    • pp.45-54
    • /
    • 2018
  • Objective: The purpose of this study was to investigate the effect of foot strengthening exercise program and functional insoles on joint angle and plantar pressure in elderly women. Thirteen elderly women who were enrolled in a university senior citizens academy of a metropolitan city in 2017 were divided into two groups: exercise group with functional insole (n=7) and exercise group without functional insole (n=6). Method: Three-dimensional motion analysis and Pedar-X were performed to compute the joint angle and the foot plantar pressure, respectively. Two-way repeated measure ANOVA was conducted to compare dependent variables within and between groups. The significance level was set at ${\alpha}=.05$. Results: The range of motion (ROM) of the ankle, knee, and hip joints in the exercise group with functional insole increased significantly more than the exercise group without functional insole. In both the experimental group and the comparison group, the maximum foot plantar pressure and the mean foot plantar pressure were decreased, but the comparison group without functional insole showed more decrease. Since the experimental group demonstrated greater pressure than the comparison group in the contact area (forefoot, midfoot), it was distributed over a greater area. Conclusion: The results of this study suggest that participation in foot strengthening exercises and using a functional insole has more positive effects than foot strengthening exercises alone on the joint angle and plantar pressure in elderly women. Increased foot plantar pressure led to an increased contact area (forefoot, midfoot) for distribution of the foot plantar pressure, but the effect of reducing the maximum and average plantar pressures was incomplete. However, wearing functional insoles along with exercise, could help in improving the stability of the joints, by increasing the range of motion, and could help the elderly in movement of the muscles more effectively, leading to an improvement in gait function.

Effect of Hallux Point Insole on Foot Contact Area and Pressure (할룩스 포인트 인솔이 발의 접촉면적 및 압력에 미치는 영향)

  • Lee, Su-Kyong;Ahn, Su-Hong;Kim, Yong-Woon;Yang, Ki-Eun
    • PNF and Movement
    • /
    • v.19 no.2
    • /
    • pp.233-242
    • /
    • 2021
  • Purpose: The purpose of this study was to determine the changes in foot contact area and pressure when walking with a functional insole that emphasizes the Hallux point as compared to a general insole. Methods: In this study, an experiment was conducted to investigate changes in plantar pressure and contact area for a functional insole that emphasized the Hallux point as compared to a general insole. A lower extremity robot was used for walking reproduction. First, the gait sequence according to the two insoles was determined through a randomized controlled trial comparison. According to the sequence procedure, the insole was attached to the shoe and then worn on the right side of the lower extremity robot for gait reproduction at a normal gait speed of 20 steps per minute. After programming the robot to walk, the experiment was carried out. The result value was determined by averaging the pressure and area data of the fore and rear foot measures after walking at 20 steps per minute. Results: The functional insole that emphasized the hallux point significantly increased the forefoot and rearfoot contact area (p < 0.05) and significantly decreased the forefoot and rearfoot contact pressure (p < 0.05) compared to the general insole. Conclusion: A functional insole that emphasizes the hallux point does not collapse the medial longitudinal arch during gait, increasing foot stability and reducing fatigue. Thus, this functional insole needs to be widely used clinically.

The Analysis of Muscle Activities on the Lower Limb during Wearing Functional Insole (다기능성 인솔 착용 시 하지의 근활성도 분석)

  • Park, Jae-Young
    • Korean Journal of Applied Biomechanics
    • /
    • v.20 no.3
    • /
    • pp.327-336
    • /
    • 2010
  • The purpose of this study was to analyze muscle activities on functional insole with diet effect. Originally, ten healthy female subjects with an average age of 23.2 year(S.D=1.1), weight of 49.7 kg(S.D=4.9), height of 163.2 cm(S.D=3.5) and a shoe size of 237.5 cm(S.D=4.9) were participated in this experiment. Ten healthy females walked on a treadmill(speed=about 4.2 km/h) wearing two different insole types. Muscle activities data was collected using the EMG operating system. The surface EMG signal for tibialis anterior(TA), gastrocnemius(GA), vatus lateralis(VL) and biceps femoris(BF) were acquired at the RMS(10 Hz, 350 Hz) using Noraxon Telemyo DTS system(Noraxon inc, USA). This study processed the data using the Windows SPSS ver.17.0 to get an independent t-test, with the setting, p<.05. Analysis of muscle activity were measured and calculated during walking. The results are as follow: Functional insole wearing were increased muscle activities significantly from Tibialis anterior(TA) during total gait cycle. Normal distribution was demonstrated in total step of stances period. One foot standing position showed decreased muscle activity. Two foot standing position was demonstrated with gastrocnemius and biceps femoris. As a result of the analysis, Functional insole will inerease the diet effect in the use of four muscle groups.

Comparison of the Contact Area, Maximum Pressure, Maximum Average Pressure and Maximum Force between Functional Insoles and General Insoles (기능성 인솔과 일반 인솔의 발에 대한 접촉 면적, 최대 압력, 최대 평균압력 및 최대 힘 비교)

  • Lee, Su-Kyoung
    • PNF and Movement
    • /
    • v.20 no.3
    • /
    • pp.431-441
    • /
    • 2022
  • Purpose: The purpose of this study was to compare the changes in the contact area, maximum pressure, maximum mean pressure, and maximum force of functional insoles and general insoles when walking. Methods: Foot pressure was measured by the ignition of functional insoles and general insoles on Company N shoes. The foot pressure was measured using a precision pressure distribution meter (Pedar - X mobile system, Novel, Germany). Each insole sensor contained 99 independent cells and was inserted between the foot and the shoe. A wireless Bluetooth-type program was used to measure the pressure detected by the measuring insoles. In order to eliminate adaptation and fatigue caused by wearing the guide during the experiment, sufficient rest was taken between each experiment, and the wearing order was randomly selected. Results: Functional insole significantly increased the forefoot and midfoot (medial, lateral) (p<0.05), while total foot, forefoot, and rearfoot peak pressure significantly decreased (p < 0.05) compared to the general insole. Conclusion: In the functional insole, a high contact area was measured inside, even in the middle of the foot, leading to a proper change in foot pressure. It was confirmed that the contact area was reduced and dispersion occurred well. In addition, it was found that the maximum pressure in the front and back of the entire foot was reduced, so the weight pressure dispersion in the functional insole was evenly distributed, and the maximum average pressure change was similar.

Analysis of the Plantar Pressure on the Flat and Slope Walking by Insole Type

  • Kim, Bu Gan;Lee, Joong Sook;Yang, Jeong Ok;Lee, Bom Jin
    • Korean Journal of Applied Biomechanics
    • /
    • v.28 no.3
    • /
    • pp.165-173
    • /
    • 2018
  • Objective: The purpose of this study is to provide biomechanical basis data for the analysis of the maximum vertical ground reaction force, the maximum plantar pressure, the average plantar pressure, and the contact area according to the type of the insole through the insole insertion type foot pressure gauge. Method: In the treadmill, the slope was set at 10%, the first type A was worn at a walking speed of 3.5 km / h, and then walking was carried out using B, C, and D types. Data from 20 boots with consistent walking were extracted and plantar pressure data were collected and analyzed. Results: Functional insole was more effective than conventional insole for maximum vertical ground reaction force, maximum plantar pressure, average plantar pressure, and contact area at 10% of treadmill ramps. Conclusion: In this study, D-type insole supports the cushion in the middle part and supports the heel cup with hardness in the hind part, so that it is the most effective insole by lowering the plantar pressure and dispersing it more widely.

The Biomechanical Comparison of Running Shoes According to the Difference of Insole (인솔 차이에 따른 런닝화의 운동역학적 비교)

  • Jin, Young-Wan;Shin, Sung-Hwon
    • Korean Journal of Applied Biomechanics
    • /
    • v.17 no.2
    • /
    • pp.51-59
    • /
    • 2007
  • These studies show that I applied to functional insole (a specific A company) for minimizing shocks and sprain people's ankle arising from running. How to an effect on human body which studied a kinematics and kinetics from 10 college students during experiments. This study imposes several conditions by barefoot, normal running shoes and put functional insole shoes ran under average $2.0{\pm}0.24\;m$/sec by motion analysis and ground reaction force that used to specific A company. First of all, motion analysis was caused by achilles tendon angle, angle of the lower leg, angle of the knee, initial sole angle and barefoot angle. The result of comparative analysis can be summarized as below. Motion analysis showed that statically approximates other results from achilles tendon angle (p<.01), initial ankle angle(p<.05), initial sole angle(p<.001) and barefoot angle(p<.001). Ground reaction force also showed that statically approximates other results from impact peak timing (p<.001), Maximum loading rate(p<.001), Maximum loading rate timing (p<.001) and impulse of first 20 percent (p<.001). Above experiment values known that there was statically difference between Motion analysis and Ground reaction force under absorbing of the functional insole shoes which was not have an effect on our body for kinetics and kinematics.

The Effect of Protective Socks Combined with Functional Insole on Plantar Foot Pressure in Healthy Adults: A Pilot Study (정상인 대상으로 기능성 인솔과 결합한 보호형 양말이 발바닥 압력에 미치는 영향: 예비 실험 연구)

  • Jung, Do-Young
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.13 no.1
    • /
    • pp.147-154
    • /
    • 2018
  • PURPOSE: This study examined the ability of experimental socks combined with a functional insole to reduce plantar foot pressure in healthy subjects. METHODS: The study enrolled 15 subjects. An in-shoe measurement device was used to measure the peak plantar pressure while walking. The peak forefoot, midfoot, and hindfoot plantar pressure data were collected under two conditions: the subjects were wearing their own socks and while they were wearing the experimental socks. The paired t-test was used to determine the differences in peak plantar pressure between the two conditions at all three positions. RESULTS: Wearing the experimental socks resulted in a significantly higher peak plantar pressure in the medial forefoot and midfoot areas than wearing one's own socks (p<.05), and also in significantly lower peak plantar pressure in the medial and lateral hindfoot (p<.05). However, there were no significant differences of peak plantar pressure between experimental and own socks in middle and lateral forefoot (p>.05). CONCLUSION: The experimental socks combined with a functional insole decreased plantar pressure in the hindfoot and supported the medial longitudinal arch. However, it is necessary to change the design and material of the forefoot area in the functional insole to prevent foot ulcer at that location in people with diabetes mellitus.

The Development of the Insole for Gait Load Decreasing by Biomechanics Analysis (생체역학적 분석을 통한 보행 부하 감소용 인솔 개발)

  • Lee, Chang-Min;Oh, Yeon-Ju
    • Journal of the Ergonomics Society of Korea
    • /
    • v.24 no.4
    • /
    • pp.23-30
    • /
    • 2005
  • The mailman's shoes should be designed in due consideration of occupational features they spend most of times to walk. For that reason, the shoes required functions to reduce the foot fatigue and to protect body by dispersing the body weight to the whole foot. In this research, for the functional improvement of the insole, insoles are investigated and analyzed by biomechanics experimentation. Under the base of these experimental results, we develop insoles that can reduce the body load and muscular-skeletal disorder. The pressures are concentrated on the metatarsus and heel by the result of analyzing pressure distributions of the using shoes. Accordingly, we offer the prototype functional insole that is ranked from high pressure to low pressure on the base of a shock absorb function. This prototype functional insole is examined for statistical significance by pressure distribution areas. The experimental results show that pressure areas are dispersed to whole foot, for this reason, pressures of the metatarsus and heel are reduced. Results of this research can not only improve the function of insoles which is suitable for occupational features, but also be a base on constructing data bases for biomechanics gait insoles.

Biomechanical Comparison Analysis of Popular Insole and Functional Insole of Running Shoes (런닝화의 일반인솔과 기능성인솔의 운동역학적 비교 분석)

  • Shin, Sung-Hwon;Jin, Young-Wan
    • Korean Journal of Applied Biomechanics
    • /
    • v.16 no.3
    • /
    • pp.9-18
    • /
    • 2006
  • These studies show that I applied to functional insole (a specific S company) for minimizing shocks and sprain people's ankle arising from running. How to an effect on human body which studied a kinematics and kinetics from 10 college students during experiments. This study imposes several conditions by barefoot, normal running shoes and put functional insole shoes ran under average $2.0{\pm}0.24$ meter per second by motion analysis, ground reaction force and electromyography that used to specific A company. First of all, Motion analysis was caused by Achilles tendon angle, Angle of the lower leg, Angle of the knee, Initial sole angle and Barefoot angle. Second, Contact time, Vertical impact force peak timing, Vertical active force and Active force timing, and Maximum loading rate under impulse of first 20 percent and Value of total impulse caused Ground reaction force. Third. The tendon fo Quadriceps femoris, Biceps femoris, Tibialis anterior and gastronemius medials caused. electromyography. 1. Ground reaction force also showed that statically approximates other results from impact peak timing (p.001), Maximum loading rate(p<.001), Maximum loading rate timing (p<.001) and impulse of first 20 percent (p<.001). 2 Electromyography showed that averagely was distinguished from other factors, and did not show about that. Above experiment values known that there was statically difference between Motion analysis and Ground reaction force under absorbing of the functional insole shoes which was not have an effect on our body for kinetics and kinematics.