• Title/Summary/Keyword: Functional Failure

Search Result 481, Processing Time 0.026 seconds

A Study on a Safety Life Cycle of IEC 61508 for Functional Safety (기능안전을 위한 IEC 61508의 안전수명주기에 관한 연구)

  • Kim, Sung Kyu;Kim, Yong Soo
    • Journal of Applied Reliability
    • /
    • v.14 no.1
    • /
    • pp.81-91
    • /
    • 2014
  • The IEC 61508 standard was established to specify the functional safety of E/E/PE safety-related systems. Safety life cycle to provide the framework and direction for the application of IEC 61508 is included in this standard. In this paper, we describe overviews, objects, scopes, requirements and activities of each phase in safety life cycle. In addition, we introduce safety integrity level(SIL) which is used for verifying the safety integrity requirements of E/E/PE system and perform a case study to estimate hardware SIL by FMEDA. The SIL is evaluated by two criteria. One of them is the architectural constraints which restrict the maximum SIL by combination of SFF and HFT. The other is the probability of failure which is classified into PFD and PFH based on frequency of demand and calculated by safe or dangerous failure rates.

Application Study on FMEA(Failure Mode and Effect Analysis) for Waterjet-lifter of Deep-Sea Manganese Nodule Miner (심해저 망간단괴 집광시스템의 물제트부양장치에 대한 FMEA 적용 연구)

  • Choi, Jong-Su;Hong, Sup;Lee, Tae-Hee;Kim, Hyung-Woo;Yeu, Tae-Kyeong
    • Journal of Ocean Engineering and Technology
    • /
    • v.23 no.6
    • /
    • pp.32-38
    • /
    • 2009
  • An FMEA for the waterjet-lifter of a DSNM is performed to prevent the occurrence of device failure. A waterjet-lifter raises and transports manganese nodules from the deep-sea floor up to a somewhat elevated place, from which a pin-scraper transports the lifted nodules to the inner space of the DSNM. A concept design for a device using the axiomatic design methodology is shown as the mapping between the functional domain and physical domain. The FMEA for a DSNM is introduced briefly and the rating criteria of severity, occurrence, and detection for the DSNM are defined. The FMEA of the functional requirements of a DSNM device is accomplished. Three kinds of failure modes, as well as their effects and causes, are predicted. Current design control methods for detecting potential failures, such as physical or computational experiments, design confirmation, and mathematical calculation, are described and the recommended actions for several significant causes are suggested.

Case Study of Patient with Pleural Effusion Due to Congestive Heart Failure (울혈성 심부전으로 인한 흉막삼출에 대한 한방치험 1례)

  • Park, Jong Joo;Ko, Seung Woo;Kong, Kyung Kwan;Go, Ho Yeon;Moon, Ju Ho
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.4
    • /
    • pp.460-464
    • /
    • 2013
  • The purpose of this case was to report the effect of Korean medical treatment for patient with pleural effusion due to congestive heart failure. The patient was treated with herbal medicine(Cheongsingeonbi-tang) and acupuncture. The effect of treatment was evaluated by chest X-ray, New York Heart Association(NYHA) functional classification, and Hugh-Jones classification. After 3 weeks of treatment, the amount of pleural effusion was decreased and NYHA class, Hugh-Jones grade were improved. NYHA functional classification improved class III to II and Hugh-Jones classification changed grade IV to II. This result suggests that herbal medicine(Cheongsingeonbi-tang) and acupuncture treatment might have an effect on patient with pleural effusion due to congestive heart failure.

An Experimental Study on the Wear and Vibrational Characteristics Resulted from Rotordynamics System Failure(I) (회전기계 파손에 따른 마멸 및 진동 특성(I))

  • Kang, Ki-Hong;Yoon, Eui-Sung;Chang, Rae-Hyuk;Kong, Ho-Sung;Kim, Seong-Jong;Lee, Yong-Bok;Kim, Chang-Ho
    • Proceedings of the Korean Society of Tribologists and Lubrication Engineers Conference
    • /
    • 2001.11a
    • /
    • pp.43-52
    • /
    • 2001
  • Condition monitoring plays a vital role since it sustains the reliable operation of industrial plant and machinery in the pursuit of economic whole life operation. In order to achieve this goal, it is needed to monitor various parameters of mechanical system such as vibration, wear, temperature, and etc., and finally to diagnosis the root causes of any possible abnormal machine condition. In this work, we constructed a rotor system where various types of functional machine failures occurred frequently in industry were induced. Characteristics of the machine failure were monitored simultaneously by the on-line measurement of vibration, wear and temperature. Result showed that these parameters responded differently to the induced functional machine failure. The availability of each parameter on effective condition monitoring was discussed in this work.

  • PDF

A Study on Cable Functional Failure Temperature by Exposed Fire in Nuclear Power Plants (원전 노출 화재시 케이블 기능상실 온도에 관한 연구)

  • Kim, Doo-Hyun;Lim, Hyuk-Soon
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.5
    • /
    • pp.41-45
    • /
    • 2011
  • The fire event occurred in fire proof zone often causes serious electrical problems such as shorts, ground faults, or open circuits in nuclear power plants. These would be directed to the loss of safe shutdown capabilities performed by safety related systems and equipments The fire event can treat the basic design principle that safety systems should keep their functions with redundancy and independency. In case of a cable fire, operators can not perform their mission properly and can misjudge the situation because of spurious operation, wrong indication or instrument. These would deteriorate the plant capabilities of safety shutdown and make disastrous conditions. In this paper, the cables of the representative nuclear power plant in korea is selected and the cable functional failure temperature by exposed fire using Cable Response to Live Fire(CAROLFIRE) is studied. It is expected that the results are very useful to know the cable failure temperature by exposed fire. We confirmed the safety and integrity of the cable by exposed fire and those results will use the based data of cable exposed fire characteristics.

An Estimative Model of Spot Weld Failure-1. Failure Criteria (점 용접점 파단의 정량적 모델-1. 파단조건식)

  • Lee, T.S.;Lee, H.Y.;Shin, S.J.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.6
    • /
    • pp.40-52
    • /
    • 1998
  • A good grasp of the failure mechanisms of resistance spot weld, widely used in joining the auto-panels, in essential to the structural/crashworthy analyses and integrity assessment of the whole auto-body. In this study, We provide an estimative model describing the failure behavior of resistance spotf weld, and apply the model to the finite element analysis of crashworthiness. First, in "Part 1-Failure Criteria", to be used for the finite element analysis of spot-welded structural panels of an auto-body, (i) a methodology for quantifying the spot weld failure and the accompanying failure criteria are presented, and (ii) the coefficients of the failure equation are determined by a munimum number of appropriate experimental tests. To achieve these, we derive the functional form of the failure envelop by limit analysis, and correlate it with the form in PAM-$CRASH^{TM}$ code, and also investigate the effect of the failure coefficients on the failure envelop form. An estimative model obtained in this Part1, as spot weld failure criteria is applied to the Macroscopic finite element analysis of autobody structural panels using PAM-$CRASH^{TM}$ code in Part 2.

  • PDF

Reliability Analysis of Multi-State UH-60 Helicopter Hydraulic Pump System with a Multi-Functional Standby Component (다기능 대기부품을 갖는 다중상태 UH-60 헬기 유압펌프시스템의 신뢰도 분석)

  • Kim, Dong-hyeon;Lee, Suk-hoon;Lim, Jae-Hak
    • Journal of Applied Reliability
    • /
    • v.15 no.4
    • /
    • pp.233-240
    • /
    • 2015
  • We analyse reliability of multi-state UH-60 helicopter hydraulic pump system with a multi-functional standby component using Markov analysis method. The system consists of seven components: 2 main pumps, 1 standby pump, 2 primary servos, and 2 tail rotor servos. The standby pump can take over when one more than components fail. Therefore the standby pump is multi-functional standby component. The system has four states: good, deteriorated, dangerous, and failed. The components have 2 states: working and failed. We assume the system is unrepairable when the components fail. We estimate failure distributions and rates using collected failure time data in field. And we classify multi-state of the system according to emergency procedure of UH-60A student handout. We obtain the reliabilities of multi-state system using Visual Basic program because the differential equations is extremely complicated and tedious to solve.

A Study on FMEDA Process for SIL Certification : A Case Study of a Flame Scanner (SIL 인증을 위한 FMEDA 프로세스 연구 : 화염검출기 사례를 중심으로)

  • Kim, Sung Kyu;Kim, Yong Soo
    • IE interfaces
    • /
    • v.25 no.4
    • /
    • pp.422-430
    • /
    • 2012
  • In this article, we introduced the estimation method by 'Safety Integrity Level'(SIL) for the criterion of safety assurance and performed a case study on a flame scanner. SIL requires probabilistic evaluation of each set of equipment used to reduce risk in a safety related system. FMEDA(Failure Modes, Effects and Diagnostic Analysis) method is widely used to evaluate the safety levels and provides information on the failure rates and failure mode distributions necessary to calculate a diagnostic coverage factor for a part or a component. Basically, two parameters resulting from FMEDA are used for SIL classification of the device : SFF(Safe Failure Fraction) and PFD(Probability of Failure on Demand). In this case study, it is concluded that the flame scanner is designed to fulfill the condition of SIL 3 in the aspect of SFF and PFD.

Reliability analysis of multi-state parallel system with a multi-functional standby component (다기능 대기부품을 갖는 다중상태 병렬시스템의 신뢰도 분석)

  • Kim, Dong-Hyeon;Lee, Suk-Hoon;Lim, Jae-Hak
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.20 no.4
    • /
    • pp.75-87
    • /
    • 2015
  • A redundant structure typically consists of primary component and standby component taking over the function of the primary component when the primary component fails. In this research, we consider a redundant structure in which a standby component can take over the function of more than one primary component when primary components fail. And we assume that the system has multi-state according to the states of components while all components have two states. This system is called as the multi-state redundant system with a multi-functional standby component. This type of redundant structure is frequently adapted by the system such as an aircraft in which the weight is an important design factor. In this paper, we propose new reliability model for this multi-state redundant system with a multi-functional standby component in order for evaluating the reliability of the system. Under the assumption that all components have constant failure rate, we evaluate the reliability of the system by applying Markov analysis method. And we investigate the effect of the multi-functional standby component by comparing reliabilities of the parallel system with multi-functional standby component and a simple parallel system and a parallel system with redundant structure.

Right ventricular failure in congenital heart disease

  • Cho, Young Kuk;Ma, Jae Sook
    • Clinical and Experimental Pediatrics
    • /
    • v.56 no.3
    • /
    • pp.101-106
    • /
    • 2013
  • Despite developments in surgical techniques and other interventions, right ventricular (RV) failure remains an important clinical problem in several congenital heart diseases (CHD). RV function is one of the most important predictors of mortality and morbidity in patients with CHD. RV failure is a progressive disorder that begins with myocardial injury or stress, neurohormonal activation, cytokine activation, altered gene expression, and ventricular remodeling. Pressure-overload RV failure caused by RV outflow tract obstruction after total correction of tetralogy of Fallot, pulmonary stenosis, atrial switch operation for transposition of the great arteries, congenitally corrected transposition of the great arteries, and systemic RV failure after the Fontan operation. Volume-overload RV failure may be caused by atrial septal defect, pulmonary regurgitation, or tricuspid regurgitation. Although the measurement of RV function is difficult because of many reasons, the right ventricle can be evaluated using both imaging and functional modalities. In clinical practice, echocardiography is the primary mode for the evaluation of RV structure and function. Cardiac magnetic resonance imaging is increasingly used for evaluating RV structure and function. A comprehensive evaluation of RV function may lead to early and optimal management of RV failure in patients with CHD.