• 제목/요약/키워드: Functional Failure

검색결과 483건 처리시간 0.027초

On the Ensuring Safety and Reliability through the Application of ISO/PAS 21448 Analysis and STPA Methodology to Autonomous Vehicle

  • Kim, Min Joong;Choi, Kyoung Lak;Kim, Joo Uk;Kim, Tong Hyun;Kim, Young Min
    • International Journal of Internet, Broadcasting and Communication
    • /
    • 제13권3호
    • /
    • pp.169-177
    • /
    • 2021
  • Recently, the use of electric and electronic control systems is increasing in the automobile industry. This increase in the electric and electronic control system greatly increases the complexity of designing a vehicle, which leads to an increase in the malfunction of the system, and a safety problem due to the malfunction is becoming an issue. Based on IEC 61508 relating to the functional safety of electrical/electronic/programmable electronics, the ISO 26262 standard specific to the automotive sector was first established in 2011, and a revision was published in 2018. Malfunctions due to system failure are covered by ISO 26262, but ISO/PAS 21448 is proposed to deal with unintended malfunctions caused by changes in the surrounding environment. ISO 26262 sets out safety-related requirements for the entire life cycle. Functional safety analysis includes FTA (Fault Tree Analysis), FMEA (Failure Mode and Effect Analysis), and HAZOP (Hazard and Operability). These analysis have limitations in dealing with failures or errors caused by complex interrelationships because it is assumed that a failure or error affecting the risk occurs by a specific component. In order to overcome this limitation, it is necessary to apply the STPA (System Theoretic Process Analysis) technique.

한국형 고속열차 추진시스템의 신뢰성 평가 (Reliability Assessment of Traction System of Korean High Speed Train)

  • 서승일;박춘수;한영재;이태형;김기환
    • 한국철도학회논문집
    • /
    • 제8권5호
    • /
    • pp.434-438
    • /
    • 2005
  • In this paper, as the first step to assess and enhance the reliability of Korea High Speed Train, an electric traction system is selected and reliability analysis is carried out. The electric traction system is classified into subsystems and functional block diagrams and reliability block diagrams are drawn. Expressions for evaluating the reliability are derived and Mean Kilometer Between Service Failure is calculated using the trial track test results. The calculation results show reliability growth of the proposed system.

St. Jude Medical valve의 임상적 고찰 (Clinical Experiences of St. Jude Medical Cardiac Valve Replacement)

  • 김종원
    • Journal of Chest Surgery
    • /
    • 제25권5호
    • /
    • pp.518-525
    • /
    • 1992
  • 50 months experience with St-Jude Medical Cardiac Valve Prosthesis The St. Jude Medical valve has become our mechanical valvular prosthesis of choice because of favorable hemodynamic results that associated with marked clinical improvement and low incidence of thromboembolism. The data for this study was collected from April 1986 to May 1990, four years period. There were total of 110 patients[female 53, male 58] in this series with 22 isolated aortic valve, 66 isolated mitral valve, 20 double valve, 2 tricuspid valve replacement. The mean follow up time was 23 months. Postoperatively, 77% of cases were in New York Heart Association[NYHA] functional class I, and mild and moderate symptoms[NYHA II ] were present in 20% and there were very few patients remaining in higher functional classifications. In postoperative echocardiographic study showed marked improved cardiac function. The overall early mortality was 5.4% and was higher after double[13.3%] and mitral valve replacement[5.6%] and the late mortality was one case after mitral valve replacement due to endocarditis. The cause of death in early mortality was attributed to heart failure, acute renal failure, sepsis, etc.

  • PDF

Comparison of traditional and simplified methods for repairing CAD/CAM feldspathic ceramics

  • Carrabba, Michele;Vichi, Alessandro;Louca, Chris;Ferrari, Marco
    • The Journal of Advanced Prosthodontics
    • /
    • 제9권4호
    • /
    • pp.257-264
    • /
    • 2017
  • PURPOSE. To evaluate the adhesion to CAD/CAM feldspathic blocks by failure analysis and shear bond strength test (SBSt) of different restorative systems and different surface treatments, for purpose of moderate chipping repair. MATERIALS AND METHODS. A self-adhering flowable composite (Vertise Flow, Kerr) containing bi-functional phosphate monomers and a conventional flowable resin composite (Premise Flow, Kerr) applied with and without adhesive system (Optibond Solo Plus, Kerr) were combined with three different surface treatments (Hydrofluoric Acid Etching, Sandblasting, combination of both) for repairing feldspathic ceramics. Two commercial systems for ceramic repairing were tested as controls (Porcelain Repair Kit, Ultradent, and CoJet System, 3M). SBSt was performed and failure mode was evaluated using a digital microscope. A One-Way ANOVA (Tukey test for post hoc) was applied to the SBSt data and the Fisher's Exact Test was applied to the failure analysis data. RESULTS. The use of resin systems containing bi-functional phosphate monomers combined with hydrofluoric acid etching of the ceramic surface gave the highest values in terms of bond strength and of more favorable failure modalities. CONCLUSION. The simplified repairing method based on self-adhering flowable resin combined with the use of hydrofluoric acid etching showed high bond strength values and a favorable failure mode. Repairing of ceramic chipping with a self-adhering flowable resin associated with hydrofluoric acid etching showed high bond strength with a less time consuming and technique-sensitive procedure compared to standard procedure.

($XiVE^{(R)}$ 임프란트의 성공률에 관한 후향적 연구;임상성적에 관한 조기평가 (Retrospective Study of Success Rate of the $XiVE^{(R)}$ Implant;Early evaluation of clinical performance)

  • 박진우
    • Journal of Periodontal and Implant Science
    • /
    • 제35권1호
    • /
    • pp.65-76
    • /
    • 2005
  • This retrospective study evaluates the clinical performance of the recently introduced $XiVE^{(R)}$ implant(Dentsply-Friadent) with a new macro-design to improve primary stability. A total of 208 $XiVE^{(R)}$ implants (101 in the maxilla and 107 in the mandible) were placed in 71 patients. The average age of the patients was 49 years. Of the 208 implants, 190 (91.3%) were posterior implants and 82 (39.4%) were placed in compromised sites (grafted sites). Clinical and radiographic evaluation were made at second stage surgery for exposure and after functional loading. 192 implants in 64 patients were evaluated at exposure and 146 implants in 50 patients were loaded (average 170 days-loading) and evaluated after functional loading. Of 192 implants available for evaluation before loading, 3 implants failed (early failure) ; 1 before exposure, 1 at exposure and 1 during prosthetic procedure. 2 implants were in the maxilla and 1 was in the mandible. The success rate before loading was 98.4%. After functional loading, no implant failure was occurred in 146 implants evaluated during this period (100% interval success rate). This preliminary data with a new implant showed excellent success rate although the majority of implants evaluated in this study were placed in the posterior region of the jaw and compromised sites.

하이브리드 전투차량의 기능안전성 적용 연구 (Research on Application of Functional Safety for Developing Combat Hybrid Electric Vehicles)

  • 장교근;이윤복
    • 한국군사과학기술학회지
    • /
    • 제15권5호
    • /
    • pp.543-549
    • /
    • 2012
  • Hybrid electric propulsion systems are expected as future primary combat platforms because the systems can supply enough electric power, easily locate components inside vehicles, and maneuver without undesired noise. However, increasing electric/electronic/software usage causes abnormal failure patterns which have not been noticeable in conventional automotive. Recently, the functional safety standard for road vehicles were enacted and vehicle manufacturers request their components which satisfy standardized quality. This research analyzes functional safety standards(IEC 61508 and ISO 26262) and compares the standards for road vehicles with military standards of system safety. Strategies to apply functional safety in the combat hybrid electric vehicle are scrutinized.

공정안전향상을 위한 Safety Integrity Level의 적용 방향 (Towards the Application of Safety Integrity Level for Improving Process Safety)

  • 권혁면;박희철;천영우;박진형
    • 한국안전학회지
    • /
    • 제27권5호
    • /
    • pp.64-69
    • /
    • 2012
  • The concept of SIL is applied in the most of all standards relating to functional system safety. However there are problems for the people to apply SIL to their plants. as these standards don't include sufficient informations. In this regards, this paper will suggest the direction of SIL application and concept based on IEC 61508 and IEC 61511. A Safety Integrity Level(SIL) is the discrete level(one out of possible fours), corresponding to a range of the probability of an E/E/PE (Electric/Electrical/Programmable Electrical) safety-related system satisfactorily performing the specific safety functions under all the stated conditions within a stated period of time. SIL can be divided into the target SIL(or required SIL) and the result SIL. The target SIL is determined by the risk analysis at the analysis phase of safety lifecycle and the result SIL is calculated during SIL verification at the realization phase of safety lifecycle. The target SIL is determined by the risk analysis like LOPA(Layer Of Protection Analysis), Risk Graph, Risk Matrix and the result SIL is calculated by HFT(Hardware Fault Tolerance), SFF(Safe Failure Fraction) and PFDavg(average Probability of dangerous Failure on Demand). SIL is applied to various areas such as process safety, machinery(road vehicles, railway application, rotating equipment, etc), nuclear sector which functional safety is applied. The functional safety is the part of the overall safety relating to the EUC and the EUC control system that depends on the correct functioning of the E/E/PE safety-related systems and other risk reduction measures. SIL is applied only to the functional safety of SIS(Safety Instrumented System) in safety. EUC is the abbreviation of Equipment Under Control and is the equipment, machinery, apparatus or plant used for manufacturing, process, transportation, medical or other activities.

원자력발전소 케이블 노출 화재 시 기능상실온도 분석 (Cable Functional Failure Temperature Evaluation of Cable Exposed to the Fire of Nuclear Power Plant)

  • 임혁순;배연경;지문구
    • 한국화재소방학회논문지
    • /
    • 제26권1호
    • /
    • pp.10-15
    • /
    • 2012
  • 원전 방화지역에서 화재가 발생할 경우 안전정지 케이블은 단락, 접지, 단선 등 전기적 고장으로 케이블에 고장이 발생하여 그 결과로 안전정지계통의 설비와 기기는 안전정지 기능을 상실할 수 있다. 따라서 원자력 발전소 안전정지계통의 설비와 기능은 다중설계, 계열간 독립 및 분리 원칙에 따라 운영되고 있다. 케이블 화재의 경우 기기 오동작과 오지시 또는 잘못된 계측을 유발할 수 있으며 운전원의 상황 판단에 오류를 일으켜 안전정지 기능을 저해할 수 있다. 본 논문에서는 원자력발전소 케이블 화재 조사 및 원인 분석, 케이블 화재온도 및 기능상실 기준 및 국내 원자력발전소에서 사용중인 케이블을 선정하여 노출 화재 시 케이블 기능상실 온도를 분석하여 케이블 안전성을 확인하였다.

70세이상 환자에서의 개심술 (Open Heart Surgeries in Septuagenarians.)

  • 김형수;이원용;지현근;김응중;홍기우
    • Journal of Chest Surgery
    • /
    • 제32권11호
    • /
    • pp.1017-1022
    • /
    • 1999
  • Background: An increasing number of elderly are referred for open heart surgeries(OHS). These patients are assumed to have significantly increased morbidity and mortality because of compromised functional reserves in their vital organs. We reviewed the results of OHS patients who were 70 years old or older. Material and Method: Thirty six consecutive septuagenarians underwent OHS from 1995 to 1997. Operations were coronary artery bypass grafting(CABG) in 26 including 3 left main surgical angioplasty, valve replacement in 7, MVR+CABG in 2, and ASD closure+TAP in 1. Statistical tests were carried out to compare survivor group with nonsurvivor group in respect to risk factors including NYHA functional class, LVEF, emergent operation, IABP support, CPB/ACC time, ventilator time cardiac index, ICU stay and hospital stay for operative mortality. Result: Operative mortality rate and postoperative complication were 16%(6/36) and 50%(18/36). One-year and 3-year actuarial survival rates were 76%. Nine patients(25%) had major complications including third-degree A-V block(2), respiratory failure(1), stroke(3), renal failure requiring dialysis(3) and postoperative hemorrhage(2). The causes of death were pneumonia(1), bleeding(1), acute renal failure(1), low cardiac output(1), third-degree A-V block(1), and ventricular tachycardia(1). The univariate analysis of mortality shows that NYHA class IV, LVEF<40%, lesser values for C.I, and longer time for ventilatory support were associated with the risk factors(p value=0.03, 0.001, 0.007, and 0.014). The emergent operation, CPB/ACC time, IABP support, ICU stay and hospital stay were not significant. Conclusion: We conclude that cardiac operation can be performed in septuagenarians with acceptable outcomes when done in patients with normal to moderately depressed left ventricular function and adequate functional reserves in their vital organs.

  • PDF