• Title/Summary/Keyword: Fume

Search Result 794, Processing Time 0.023 seconds

Levels and Related Factors of Airborne Fungi in Microbial and Chemistry Laboratories in Universities (일부 대학교 미생물실험실 및 화학실험실에서의 진균 분포 및 관련인자)

  • Hwang, Sung-Ho;Jo, Hyun-Woo;Park, Dong-Uk;Yoon, Chung-Sik;Ryu, Kyong-Nam;Ha, Kwon-Chul
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.41-46
    • /
    • 2010
  • The purpose of this study is to assess the level of fungi concentration in the university laboratories in Seoul, Korea, and to investigate factors contributing to these concentrations. The samples were taken from three spots in each laboratory; the top of sink, the center of laboratory, and the front of ventilation system, i.e fume hood at the chemical laboratory and clean bench/biosafety cabinet at the microbial laboratory. Air samples were collected using the single-stage Anderson sampler (Quick Take 30) at a flow rate of 28.3 l/min for 5 min on nutrient media in Petri-dishes located on the impactor. Fifty-two air samples were collected from 19 different laboratories (13 microbiology laboratories, 6 chemistry laboratories) in the university, and concentrations of airborne fungi showed no significant difference (p>0.05) between microbiology and chemistry laboratory, and also no significant difference at three locations (sink, center, front of ventilation system) in microbiology and chemistry laboratories. Average concentrations of fungi in 19 laboratories ranged from 7 to 459 cfu/$m^3$, with an overall Geometric Mean of 52 cfu/$m^3$. Airborne fungi concentrations of 6 samples (12 %) exceeded 150 cfu/$m^3$, the guideline of WHO. The ratios of Indoor/Outdoor for airborne fungi ranged from 0.2 to 4.8 (mean = 1.6). Related factors were measured such as relative humidity, temperature, and laboratory area. Temperature and laboratory area showed no significant relations to concentrations of airborne fungi except for relative humidity in the laboratory Concentrations of fungi were significant different (p<0.01) between rainy or cloudy and sunny. However, there was no significant difference between general ventilation and nongeneral ventilation.

Characterization of Rheology on the Multi-Ingredients Paste Systems Mixed with Mineral Admixtures (광물혼화재가 혼합된 다성분 페이스트 시스템의 레올로지 특성 평가)

  • Park Tae-Hyo;Noh Myung-Hyun;Park Choon-Keun
    • Journal of the Korea Concrete Institute
    • /
    • v.16 no.2 s.80
    • /
    • pp.241-248
    • /
    • 2004
  • The rheological properties of cement paste system mixed with mineral admixtures (MAs) used to increase the strength and improve durability and fluidity of concrete were investigated. And cement paste systems were designed as one-, two- and three-ingredients blended paste systems. The rheological properties of paste systems were assessed by Rotovisco RT 20 rheometer (Hakke inc.) having a cylindrical serrated spindle. The rheological properties of one-ingredient paste systems were improved with increasing the dosage of superplasticizer. For two-ingredients paste systems, as increasing the replacement ratio of blast furnace slag (BFS) and fly ash (FA), the yield stress and plastic viscosity were decreased compared with non-replacement. In the ordinary portland cement (OPC)-silica fume (SF) paste systems, in accordance with an increase in the replacement ratio of SF, the yield stress and plastic viscosity were increased steeply. For three-ingredients paste systems, both OPC-BFS-SF and OPC-FA-SF paste systems, the rheological properties were improved compared with the only replacement of SF. In the case of both two-and three-ingredients paste systems, the rheological properties using BFS were improved more than FA.

An Experimental Study for Improving the Durability of Concrete Bridge Decks (교량 바닥판 콘크리트의 내구성 증진을 위한 실험적 연구)

  • Suh, Jin-Won;Rhee, Ji-Young;Ku, Bon-Sung;Shin, Do-Chul
    • Journal of the Korea Concrete Institute
    • /
    • v.19 no.4
    • /
    • pp.393-399
    • /
    • 2007
  • Concrete bridge decks are directly exposed to the severe environmental conditions such as rain water and deicing chemicals resulting in the freeze-thaw action and the rebar corrosion during their service lift. These deteriorations of bridge decks shorten the service lift and consequently they are the major concerns of the maintenance. The high performance concrete (HPC) deck is proposed as the alternative to minimize the deterioration problems. To develop more durable concrete deck, the performance characteristic tests of HPC mixtures were carried out. In this study, 4 different concrete mixtures were used varying the mineral admixtures as the cement replacement; ordinary portland cement (OPC), 20% fly ash (FA),20% fly ash with 4% silica fume (FS), and 40% ground granulated blast-furnace slag (BS). The design compressive strengths of HPC specimens were 27 MPa and 35 MPa, respectively. The results showed that the compressive strength of concrete did not much affect the durability of concrete. HPC with fly ash and silica lune (FS) were turned out to have the good durability and crack resistance.

Resistance to Corrosion of Reinforcing Steel and Critical Chloride Content of High Volume Fly Ash Concrete (하이볼륨 플라이애시 콘크리트의 철근부식 저항성 및 임계 염화물량)

  • Lee, Hyun-Jin;Bae, Su-Ho;Jung, Sang-Hwa
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.5 no.4
    • /
    • pp.375-381
    • /
    • 2017
  • Recently, due to the increasing of interest about the eco-friendly concrete, it is being increased to use concretes containing by-products of industry such as fly ash, ground granulated blast furnace slag, silica fume, and etc. Especially, these are well known for improving the resistance to reinforcement corrosion in concrete and decreasing chloride ion penetration. The purpose of this experimental research is to evaluate the resistance to corrosion of reinforcement and critical chloride content of high volume fly ash concrete(HVFAC) which is replaced with fly ash for approximately 50% cement content. For this purpose, corrosion monitoring of reinforcement by half cell potential method was carried out for the cylindrical test specimens that the upper of reinforcement in concrete was exposed to detect the time of corrosion initiation for reinforcement. It was observed from the test result that the the time of corrosion initiation for reinforcement of HVFAC by the accelerated corrosion tests increased 1.2~1.3 times than plain concrete and the critical chloride contents of plain concrete and HVFAC were found to range $0.80{\sim}1.20kg/m^3$, $0.89{\sim}1.60kg/m^3$, respectively.

Indoor Air Quality of Laboratories in K- University and the Management Strategy (K대학교 실험실의 실내공기질 실태 및 관리방안)

  • Lee, Dong-Hyun;Jeong, Hyo-Sik
    • The Journal of the Korea Contents Association
    • /
    • v.12 no.5
    • /
    • pp.323-330
    • /
    • 2012
  • The purpose of this study was to examine the occurrence level of harmful chemical substance and the riskiness caused by it at university laboratory, which had been faintly interested in safe health management. It measured and analyzed indoor pollutants by academic department targeting K university where is located in Seoul Metropolis for 6 days starting from May 26, 2010. As a result, the appearance of being furnished with MSDS, the appearance of installing the exposure-reduction facilities, and the present status of supplying protective equipment in order to grasp the present status of managing harmful chemical substance at university laboratory were relatively good in management at the Dept. of Chemistry, the Dept. of Physics, and the Dept. of Medical Science, which are basic science laboratories. The activity for managing harmful chemical substance in the Dept. of Dental Medicine and the Dept. of Fine Arts was surveyed to be insufficient. Also, the concentration of formaldehyde and TVOCs(total volatile organic compounds) inside laboratory was detected noticeably highly in the Dept. of Fine Arts compared to other laboratories. The concentration of formaldehyde in a group, which was collectivized by similar academic department, was indicated to be higher in other academic departments including the Dept. of Fine Arts and the Dept. of Life Science, thereby having shown significant difference. The concentration of formaldehyde and TVOCs showed significant difference at the laboratory without installation compared to the laboratory with installation of fume hood. Seeing the above results, it could be known that a whole drop in recognition on influence of chemical upon health leads to being able to increase occurrence level of hazardous factor due to being insufficient in activity of protecting exposure to chemical substance.

Effect of soil fumigation treatment on the growth and the chemical composition of Korea ginseng, Panax ginseng C.A. Meyer (토양훈증제 처리가 2년생 인삼의 생육과 화학적 조성에 미치는 영향)

  • Ahn Y.J.;Kim Y.T.;Kim M.S.;Choi S.Y.
    • Korean journal of applied entomology
    • /
    • v.20 no.1 s.46
    • /
    • pp.31-36
    • /
    • 1981
  • These experiments were conducted to investigate some effects of the soil fumigants Dow-fume MC-2, Cylone, TeloneC-17, and D-D on the growth response of the Korea ginseng(two-year old), Panax ginseng C.A. Meyer, and the chemical composition of the plants. Fumigant treatment increased growth of roots, stems, and leaves. The increase of root growth rates ranging from 2.8 to $58.7\%$ in fresh weight and 8.1 to $63.8\%$ in dry weight were observed in the 2-year old ginseng plants grown in the old ginseng soil treated with the different soil fumigants. The chemical analysis of inorganic elements such as N, P, K, Ca, Mg, Na, Fe, Mn, and Zn was made for the roots, stems and leaves of the 2-year old plants. The increases or decreases of content of the elements were observed, and their contents of each of the elements were changed with the kind of fumigants, part of the plants, and soil depth of the fumigant treatments, but their changing tendencies were not steady.

  • PDF

An Evaluation on Airborne Particulate and It's Components in the Welding Workplace for the Ship Construction Industry (조선업 용접작업장의 공기중 입자상물질 및 구성성분에 관한 연구)

  • Kang, Yong-Seon;Shin, Joong-Kyu;Lee, Song-Kwon;Yoon, Chung-Sik;Lim, Moo-Hyuk;Park, Man-Chul;Sim, Sang-Hyo
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.245-253
    • /
    • 2007
  • This research was performed to evaluate the airborne personal concentration of hazardouse materials during the process of ship construction and surveyed from May 23 to June 30, 2007 in Kyungnam West Distirct, Korea. The subject was 94 ship construction workers exposed to welding fume and respirable particulate. The airborne concentrations of those were compared to Permissible Exposure Limit(PEL) from the Ministry of Labor in Korea. The airborne concentration of 23 samples(48.9%) of welding fumes was less than $5mg/m^3$, that of 16 (34.0%) was between 5 and $10mg/m^3$, and that of 8 (17.0%) was greater than $10mg/m^3$. The airborne concentration of 27 (57.4%) of respirable particulate masses was less than $5mg/m^3$ and the othere are greater than $5mg/m^3$. The welding fumes were identified containing the heavy metasl such as Fe, Mn, Zn, Mg, Ca, and Cu. The respirable particulates has similiar tendency with welding fumes in the component of heavy metals. But the concentration of Ca, Cu, Cr, and Ni turned out to be higher in welding fumes. Twenty (42.6%) of the 47 samples of welding fumes were exceeded PEL. In the heavy metals in welding fumes, ten (21.3%) of the 47 samples of Mn were exceeded PEL. Based on the results, the higher airborne hazardous materials were still exposed to wokers in ship construction process. It is suggested that the appropriate engineering control be applied to minimize the exposed cocnetration in ship building processes.

Effect of Mn and Fe Compound on the Absorption in the Body and Genital Organs, Activity with F344 Rats (F344 rats를 이용 망간 및 철 화합물의 체내 흡수와 생식기 및 운동성에 미치는 영향)

  • Kim, Hyeon-Yeong;Lee, Sung-Bae;Han, Jeong-Hee;Choi, Sung-Bong;Kang, Min-Gu;Lee, Chae-Kwan
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.3
    • /
    • pp.224-234
    • /
    • 2007
  • This study aimed to examine the harmful effects of Mn and Fe, which may be generated as dust or fume in the industrial sites, on the body and genital organs by their inhalation. It is intended to find the characteristics and differences of the hazardousness by inhaling a single and the mixed materials of Mn and Fe. Male F344 rats were divided into the control group and 3 exposed groups on the basis of the test material compound (Mn $1.5mg/m^3$, Mn 1.5 and Fe $3.0mg/m^3$, Fe $3.0mg/m^3$). The 4 groups were divided into 4 subgroups again on the basis of the exposure period (4 and 13 weeks) and the recovery period (4 and 13 weeks). The exposure condition was 6 hours a day, 5 days a week for the whole body. Clinical tests including changes in weight and feed rate, blood biochemical test, motility change, changes in the number and the amount of spermatozoon (sperm count), daily sperm production (DSP), deformity test of spermatozoon and changes in the accumulation of Mn and Fe in blood and internal organs were performed. Motility was reduced by Mn exposure. Especially, the effect of Mn was exposure period responsible. By mixing with Fe, no significant change in motility Mn and Fe accumulation in organs was observed. Sperm count and daily sperm production (DSP) were decreased by Mn. Additional effect like the reduction of sperm count and DSP, and delayed restoration of sperm count and DSP during the recovery period were observed in the mixed exposure group. These results indicate that Mn and Fe may affect the motility reduced and has male reproductive toxicity. Mixed exposure of Mn and Fe lead to synergic effects on the male reproductive toxicity.

The Fundamental Study on Properties of Concrete Using the Garnet with Industrial Wastes (산업부산물인 가네트를 이용한 콘크리트의 성질개선에 관한 기초적 연구)

  • Lim, Byoung-Ho;Park, Jung-Min;Kim, Tae-Gon;Kim, Wha-Jung
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.1
    • /
    • pp.183-190
    • /
    • 1999
  • This paper investigated the possibility of appling to concrete through fundamental experiment for garnet, which was industrial wastes generated in kyung pook region, in aspects of development of new materials and recycling of industrial wastes due to shortage of natural resources. Consequently, garnet powder showed the possibility of admixture as showed in the chemical composition because the content of silica and alumina in relation to pozzolanic activity was about 50%. The time of setting was more or less diminished as the increasing of replacement ratio of garnet. In flow test, flow values tended to increase to some degree as the increasing of replacement ratio of garnet. Therefore, application of garnet was expected to improve the workability of concrete. The compressive strength of mortar replaced by garnet was respectively increased as compared with plain mortar and the maximum strength was showed in replaced by 10%, however a little different to the change of W/B ratio. Also, the possibility of admixture to reduce the amount of cement and to improve the property of concrete was showed as the strength of mortar replaced by garnet was comparable to that by existing admixture(silica fume, fly-ash).

Subhective Symptoms and Work-related Health Risk Factors in Korean Dental Laboratory Technicians (우리 나라 치과 기공사의 신체 자각 증상과 직업 관련 건강 위험 요인)

  • Kim, Woong-Chul;Lee, Se-Hoon
    • Journal of Technologic Dentistry
    • /
    • v.22 no.1
    • /
    • pp.89-112
    • /
    • 2000
  • Although dental laboratory technicians are prone to be exposed to various work-related health hazardous materials such as dusts, chemicals, etc., the prevalence and nature of work-related health problems of them have not been a matter of great concern in the field of occupational health service in Korea. The purpose of the present investigation was to describe a collected profile of subjective health symptoms and their attributable factors in Korean dental laboratory technicians. A questionnaire listing five groups of health symptoms and five health symptom-related factors was mailed to randomly selected 1,900 dental laboratory technicians. Among them, 1,344 dental laboratory technicians filled out the questionnaires and returnde them. Five groups of health symptoms included musculoskeletal symptom, dermal symptoms, respiratory symptoms, eys symptoms, and ear symptoms. Five health symptom-related factors were occupational environment-related health risk factors, work history, health related habits and status, use of personal protective equipment and general characteristics. Detailed parameters of health risk factors were work posture, vibration, and chemical or physical hazards such as dust, fume, vapor, solvent, light, and noise for occupational environment-related factors; work place, area, number of employees, work hours, career, work part, and work load for work history; Broca's index, hours of sleep, eating, smoking, alcohol, exercise, health examination, and self assessed health status for health habits and status; face masks, goggles, and so on for use of personal protective equipment, and; age, sex, marital status, and education for general characteristics. Before the start of main survey, a pilot survey was carried out for validity and reliability tests of the questionnaire. All the data obtained were coded and analyzed with PC/SAS 6.12 program. The prevalence of health symptoms was the highest in musculoskelton (87.3%), and followde by eyes (78.9%), respiratory organs (64.3%), ears (57.8%), and skin (52.2%) in descending order. Statistically significant risk factors by multiple logistic regression analyses were sex, health examination, self assessed health status, and hand/finger posture in musculoskeletal symptoms; sex, self assessed health status, career, acid gas, and hand contact with resin mixture in deraml symptoms; Broka's smoking, exercise, self assessed health status, and face mask in respiratory symptoms; sex, hours of sleep, self assessed health status, work hours, work load, plaster dust, inadequate lighting, and goggle in eys symptoms, and eating, smoking, self assessed health status, and work load in ear symptoms. With the above considerations in mind, prevalence of subjective symptoms among Korean dental laboratory technicians was relatively high, and they were attributable to most of the occupational environment-related factors, work history, use of personal protective equipment, health habits and status, and general characteristics. Particularly, it is suggested that health promotion programs for promoting self- assessed health status and smoking cessation, preventive measures for protection of the female technicians’health, and reducing work load be necessary, since those factors were associated with more than one subjective symptom.

  • PDF