• Title/Summary/Keyword: Full-wave

Search Result 712, Processing Time 0.027 seconds

Full-Wave Calculation of the Complex Input Impedance of Microstrip Line Used for Magnetostatic Surface Wave Transducers (정자표면파 트랜스듀서용 마이크로스트립 선로의 복소 입력 임피던스 Full-Wave 계산)

  • 이재현
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.15 no.4
    • /
    • pp.345-352
    • /
    • 2004
  • The radiation impedance of a magnetostatic surface wave excited in a microstrip line haying ferrite film and its dependence on the width of the microstrip line and the height of the ferrite film are calculated by the full-wave moment analysis. The radiation resistance calculated by the full-wave analysis closely agrees with the measured radiation resistance, while that by the magnetostatic approximation greatly differs from the measured result in the higher-frequency region.

A Study on the Comparision of Performance between Three-phase Full-wave and Single-phase Full-wave X-ray Generators (삼상(三相)12펄스 전파정류장치(全波整流裝置)와 단상(單相) 전파정류장치(全波整流裝置)의 성능(性能) 비교(比較))

  • Kim, Young-Ill;Kim, Chang-Kyun;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.3 no.1
    • /
    • pp.81-86
    • /
    • 1980
  • To compare three-phase 12-pulse full-wave X-ray generators with single-phase full-wave X-ray generators on their performance of outputs, authors studied the generating X-ray by means of exposure dose and radiographic density. The results were as follows; 1. The exposure doses of three-phase full-wave X-ray generators showed a 30%-60% increase as compared against of single-phase full-wave generators. 2. The transmitted doses of three-phase full-wave generators were more increased than single-phase full-wave X-ray generators. 3. To obtain the same density, 60kVp in three-phase full-wave generators were equivalent to $60{\sim}65kVp$ in single-phase full-wave generators, and 100kVp in those generators were equivalent to $100{\sim}125kVp$ in these generators.

  • PDF

Electroluminescence Characteristics of OLED by Full-Wave Rectification Alternating Current Driving Method (전파 정류 교류 구동 방식에 의한 OLED의 전계발광 특성)

  • Seo, Jung-Hyun;Ju, Sung-Hoo
    • Korean Journal of Materials Research
    • /
    • v.32 no.7
    • /
    • pp.320-325
    • /
    • 2022
  • Single OLED and tandem OLED was manufactured to analyze the electroluminescence characteristics of DC driving, AC driving, and full-wave rectification driving. The threshold voltage of OLED was the highest in DC driving, and the lowest in full-wave rectification driving due to an improvement of current injection characteristics. The luminance at a driving voltage lower than 10.5 V (8,534 cd/m2) of single OLED and 20 V (7,377 cd/m2) of a tandem OLED showed that the full-wave rectification drive is higher than that of DC drive. The luminous efficiency of OLED is higher in full-wave rectification driving than in DC driving at low voltage, but decrease at high voltage. The full-wave rectification power source may obtain higher current density, higher luminance, and higher current efficiency than the AC power source. In addition, it was confirmed that the characteristics of AC driving and full-wave rectification driving can be predicted from DC driving characteristics by comparing the measured values and calculated values of AC driving and full-wave rectification driving emission characteristics. From the above results, it can be seen that OLED lighting with improved electroluminescence characteristics compared to DC driving is possible using full-wave rectification driving and tandem OLED.

Numerical Experiments for Detecting Voids and Defects Inside Concrete (수치모형실험을 통한 콘크리트 구조물의 결함탐지에 관한 연구)

  • Kim, Yong-In;Byun, Joong-Moo;Sohn, Kwon-Ik;Suh, Baek-Soo
    • Journal of Industrial Technology
    • /
    • v.24 no.B
    • /
    • pp.163-170
    • /
    • 2004
  • In this study, First, the results of travel-time inversion (first arrival inversion using the travel-time of the first arrival) were compared with those of full-wave inversion for numerical data. Numerical experiments to find key parameters other than initial velocity model showed that the frequency of source has a great effect on the result of full-wave inversion. Finally, this research presented the corrected full-wave inversion applying the correction term to the final result of full-wave inversion. The corrected full-wave inversion depicted cavities inside concretes even when the inversion started with 20% error in an initial velocity model for cavities. However, full-wave inversion did not reveal cavities.

  • PDF

Comparison of Edge Wave Normal Modes (Edge Wave 고유파형의 비교)

  • Seo, Seung Nam
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.25 no.5
    • /
    • pp.285-290
    • /
    • 2013
  • Both full linear and shallow water edge waves are compared to get a better understanding of edge wave behavior. By using method of separation of variables, we are able to get solution of full linear edge wave presented by Ursell (1952) without derivation. The shallow water edge waves show dispersive features despite being derived from shallow water equations. When bottom slope is mild enough, shallow water edge wave tends to linear edge wave and has some advantages of manipulation. Solution of edge wave generated by a moving landslide of Gaussian shape is constructed by an expansion of shallow water normal modes. Numerical results are presented and discussed on their main features.

A Study on the Test of Efficiency of the Diagnostic X-ray Equipment according to Their Rectifications (진단용 X선장치의 성능 실태 조사연구)

  • Seon, Jong-Ryul
    • Journal of radiological science and technology
    • /
    • v.20 no.2
    • /
    • pp.44-48
    • /
    • 1997
  • For the efficient management of the diagnostic x-ray equipment, a nation-wide inspection of hospitals was performed by an inspection institute in Taejon in the first half of 1997. Among those hospitals inspected, 28 equipments(machines) which were over 500 mA were randomly selected according to their characteristics : 7 condenser type x-ray equipments, 7 three control phase of full wave rectification of type remote control x-ray equipments, 7 single phase of full wave rectification type for general radiography equipments, and 7 single phase of full wave rectification type of R/F equipments. We obtained the following results by conducting the experiment based on the efficiency of the equipments mentioned above. 1) When the equipments are analyzed, 2 out of 7 single phase of full wave rectification type of general radiography equipments(28.6%), 3 out of 7 single phase of full wave rectification type of R/F equipments(42.9%), 5 out of 7 three phase of full wave rectification type remote of control x-ray equipments(71.4%), and 4 out of 7 condenser type of x-ray equipments(57.1%) showed suitability. It proves the superiority of the three phase of full wave rectification type of remote control x-ray equipments. 2) From the overall analysis, only about 50% of the equipments(suitability of 14 out of 28) maintain the efficient management. Therefore, maintenance management of equipments is more necessary. If the efficiency of the x-ray equipment is uniformly maintained and managed to prevent the breakdown(trouble) beforehand especially through the continuous inspection of tube voltage, tube current, exposure time, and collimator, the financial loss and exposure dose to the patient, as well as the workers engaged in radiation, can be reduced for better medical service.

  • PDF

Exposure Does of X-ray Generator on Full Wave Rectification Method (전파정류 방식의 X선 발생장치에서 조사선량)

  • Kim, Tae-Gon;Kim, Young-Pyo;Cheon, Min-Woo;Lee, Ho-Shik;Park, Yong-Pil
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2010.06a
    • /
    • pp.138-138
    • /
    • 2010
  • X-ray systems for medical treatment use noninvasive procedures. I fabricated a high tension generator of a full-wave rectification type using a LC resonant inviter. It is said that a full-wave rectifying X-ray equipment such as the fabricated system can shorten initiating period and be precision control because of stable output, compared with the X-ray equipment of a half wave rectifying type used in the usual clinical medicine. In order to evaluate the capability of the fabricated high tension generator, I performed exposure dose characteristics experiments.

  • PDF

Design and Fabrication of RF-DC Converters for 5.8 GHz Microwave Wireless Power Transmission (5.8 GHz 마이크로파 무선전력전송을 위한 RF-DC 변환기의 설계 및 구현)

  • Lee, Seong Hun;Son, Myung Sik
    • Journal of the Semiconductor & Display Technology
    • /
    • v.14 no.4
    • /
    • pp.84-87
    • /
    • 2015
  • We have designed and fabricated two different RF-DC Converters called doubler for 5.8GHz Microwave Wireless Power Transmission. The doubler as RF-DC Converter makes the rectified voltage be doubled. We measured and compared voltages of the doublers with those of the previous full-wave rectifying RF-DC Converter. The doublers show rectified double voltages. However, the full-wave rectifying converter has a high efficiency due to the suppression of reflecting harmonics. The other fabricated doublers causes so many harmonics that they can't convert the low-power RF to the full DC. In this paper, we show that the different doublers doesn't double the rectifying voltages compared with those of the full-wave rectifying converter and give a reason about that.

A Full-Wave Model Analysis on Noise Reduction and Impedance of Power-Bus Cavity with Differential Signaling

  • Kahng, Sung-Tek
    • Journal of electromagnetic engineering and science
    • /
    • v.6 no.4
    • /
    • pp.197-202
    • /
    • 2006
  • This paper presents a study on the differential signaling for the rectangular power-bus structure. The full-wave modal analysis method analyzes how the differential-signaling can lower the power-bus resonance noise levels. The methodology is validated by the use of the FDTD method and reference measurements.