• Title/Summary/Keyword: Full-scan

Search Result 193, Processing Time 0.026 seconds

Structural and Electronic Properties of Cu-doped ZnO Thin Films by RF Sputtering Method

  • Lee, Ik-Jae;Seong, Nak-Eon;Yu, Cheong-Jong;Lee, Han-Gu;Sin, Hyeon-Jun;Yun, Yeong-Deok
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2011.02a
    • /
    • pp.103-103
    • /
    • 2011
  • The epitaxial Cu-doped ZnO and pure ZnO thin films were grown on Al2O3 (0001) substrates by RF sputtering method. The structures and crystallographic orientations were investigated using X-ray diffraction (XRD) and X-ray absorption spectroscopy. From the XRD pattern, it is observed that peak positions shift towards higher $2{\theta}$ value with Cu doping. The ${\omega}$-scan measurements at the (0002) diffraction peak for these samples reveal that the full-widths at half-maxima (FWHMs) are about $0.017-0.019^{\circ}$, which indicate a good c-axis orientation of the Zn1-xCuxO films. From phi-scan, all of the Zn1-xCuxO films were epitaxially grown. EXAFS measurements also demonstrated that Cu incorporated into a Zn-atom position substitutionally. All the results confirmed that copper ion were well incorporated into the ZnO lattices by substituting Zn sites without changing the wurtzite structure and no secondary phase existed in Cu-doped ZnO thin films.

  • PDF

The Analysis of the Correlation between the Sustain-Electrode Gap of an AC-PDP and Address Discharge Characteristics (AC-PDP의 유지방전 전극사이의 간격과 어드레스 방전 특성과의 상관성 분석)

  • Lee, Young-Jun;Choi, Su-Sam;Park, Se-Kwang;Kim, Yong-Duk
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.5
    • /
    • pp.239-244
    • /
    • 2006
  • To drive the high-image quality plasma displays of XGA and/or full-HD, we must effectively improve the driving waveform, which get the reset period for the stabilized control of wall charges, the address period to select discharge or non-discharge, and sustain period for luminance in 1 TV-frame, and also the display quality. To accomplish them, the development of the technology for the fast address discharge is required. In this paper, the correlation between the sustain-electrode gap and address discharge characteristics for the high-speed addressing was analyzed using the measurements of dynamic voltage margins. Results showed that the narrower the gap between the sustain electrodes, the narrower the with of the scan pulse became and a dynamic margin of data voltage of 29.2 V was obtained at scan pulse width of $1.0{\mu}s\;and\;V_{ramp}$ of 240 V for driving 4-inch test penal, which the gap between sustain electrodes was $65{\mu}m$.

Effect of different arch widths on the accuracy of three intraoral scanners

  • Kaewbuasa, Narin;Ongthiemsak, Chakree
    • The Journal of Advanced Prosthodontics
    • /
    • v.13 no.4
    • /
    • pp.205-215
    • /
    • 2021
  • PURPOSE. The purpose of this study was to compare the accuracy of three intraoral scanner (IOS) systems with three different dental arch widths. MATERIALS AND METHODS. Three dental models with different intermolar widths (small, medium, and large) were attached to metal bars of different lengths (30, 40, and 50 mm). The bars were measured with a coordinate measuring machine and used as references. Three IOSs were compared: TRIOS 3 (TRI), True Definition (TD), and Dental Wings (DW). The relative length and angular deviation of both ends of the metal bars from the scan data set (n = 15) were calculated and analyzed. RESULTS. Comparing among scanners in terms of trueness, the relative length deviation of DW in the small (1.28%) and medium (1.08%) arches were significantly higher than TRI (0.46% and 0.48%) and TD (0.33% and 0.18%). The angular deviation of DW in the small (1.75°) and medium (1.83°) arches were also significantly greater than TRI (0.63° and 0.40°) and TD (0.55° and 0.89°). Comparing within scanner, the large arch of DW showed better accuracy than other arch sizes (P < .05). On the other hand, the larger arch of TD presented a greater tendency of angular deviation in terms of trueness. No significant differences were found in terms of trueness between the arch widths of TRI group. CONCLUSION. The different widths of the dental arches can affect the accuracy of some intraoral scanners in full arch scan.

Bladder filling variations during concurrent chemotherapy and pelvic radiotherapy in rectal cancer patients: early experience of bladder volume assessment using ultrasound scanner

  • Chang, Jee Suk;Yoon, Hong In;Cha, Hye Jung;Chung, Yoonsun;Cho, Yeona;Keum, Ki Chang;Koom, Woong Sub
    • Radiation Oncology Journal
    • /
    • v.31 no.1
    • /
    • pp.41-47
    • /
    • 2013
  • Purpose: To describe the early experience of analyzing variations and time trends in bladder volume of the rectal cancer patients who received bladder ultrasound scan. Materials and Methods: We identified 20 consecutive rectal cancer patients who received whole pelvic radiotherapy (RT) and bladder ultrasound scan between February and April 2012. Before simulation and during the entire course of treatment, patients were scanned with portable automated ultrasonic bladder scanner, 5 times consecutively, and the median value was reported. Then a radiation oncologist contoured the bladder inner wall shown on simulation computed tomography (CT) and calculated its volume. Results: Before simulation, the median bladder volume measured using simulation CT and bladder ultrasound scan was 427 mL (range, 74 to 1,172 mL) and 417 mL (range, 147 to 1,245 mL), respectively. There was strong linear correlation (R = 0.93, p < 0.001) between the two results. During the course of treatment, there were wide variations in the bladder volume and every time, measurements were below the baseline with statistical significance (12/16). At 6 weeks after RT, the median volume was reduced by 59.3% to 175 mL. Compared to the baseline, bladder volume was reduced by 38% or 161 mL on average every week for 6 weeks. Conclusion: To our knowledge, this study is the first to prove that there are bladder volume variations and a reduction in bladder volume in rectal cancer patients. Moreover, our results will serve as the basis for implementation of bladder training to patients receiving RT with full bladder.

An Iterative Image Reconstruction Method for the Region-of-Interest CT Assisted from Exterior Projection Data (Exterior 투영데이터를 이용한 Region-of-Interest CT의 반복적 영상재구성 방법)

  • Jin, Seung Oh;Kwon, Oh-Kyong
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.5
    • /
    • pp.132-141
    • /
    • 2014
  • In an ordinary CT scan, a large number of projections with full field-of-view (FFOV) are necessary to reconstruct high resolution images. However, excessive x-ray dosage is a great concern in FFOV scan. Region-of-interest (ROI) CT or sparse-view CT is considered to be a solution to reduce x-ray dosage in CT scanning, but it suffers from bright-band artifacts or streak artifacts giving contrast anomaly in the reconstructed image. In this study, we propose an image reconstruction method to eliminate the bright-band artifacts and the streak artifacts simultaneously. In addition to the ROI scan for the interior projection data with relatively high sampling rate in the view direction, we get sparse-view exterior projection data with much lower sampling rate. Then, we reconstruct images by solving a constrained total variation (TV) minimization problem for the interior projection data, which is assisted by the exterior projection data in the compressed sensing (CS) framework. For the interior image reconstruction assisted by the exterior projection data, we implemented the proposed method which enforces dual data fidelity terms and a TV term. The proposed method has effectively suppressed the bright-band artifacts around the ROI boundary and the streak artifacts in the ROI image. We expect the proposed method can be used for low-dose CT scans based on limited x-ray exposure to a small ROI in the human body.

Performance of an Active Channel Scanning Scheme for Fast Handover in Mobile Wireless LAN Systems (이동무선 LAN 시스템의 고속핸드오버를 위해 능동적인 유효채널탐색방식의 성능분석)

  • Yoon, Hong;Lim, Jae-Myung;Yoon, Chong-Ho;Kim, Se-Han
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.11 s.353
    • /
    • pp.44-53
    • /
    • 2006
  • In this paper, we propose a new Active Channel Scanning scheme by scanning active channels employed by neighbor APs' with the handover counts and non overlap channel information for fast handover. Under the proposed scheme, the mobile which has finished handover to connect a new APsends the neighbor AP's channel information learned by itself during handover to the new AP. And then, the new AP relays the neighbor channel information to the old AP. It decides a priority by handover counts and non overlap channel information for building a Neighbor Channel Table(NCT), and also sends the table information to its associated mobile nodes, periodically. As a result each mobile can scan only active neighbor APs' channels when performs handover based on the referring to NCT information. Using NS-2 Simulator, we applied to supposed ACS that the result of simulation decides to sort by handover counts and non overlap channel information. we evaluate our proposed ACS scheme based on NCT along with the full scanning scheme and the selective scanning scheme. From simulation results, we show that the proposed scheme is advantageous over the other two schemes in terms of the number of scanning channels and the scanning latency.

Behavioral responses to cow and calf separation: separation at 1 and 100 days after birth

  • Sarah E. Mac;Sabrina Lomax;Cameron E. F. Clark
    • Animal Bioscience
    • /
    • v.36 no.5
    • /
    • pp.810-817
    • /
    • 2023
  • Objective: The aim was to compare the behavioral response to full separation of cows and calves maintained together for 100 days or 24 h. Methods: Twelve Holstein-Friesian cow-calf pairs were enrolled into either treatment or industry groups (n = 6 cow-calf pairs/group). The treatment cows and calves were maintained on pasture together for 106±8.6 d and temporarily separated twice a day for milking. The Industry cows and their calves, were separated within 24 h postpartum. Triaxial accelerometer neck-mounted sensors were fitted to cows 3 weeks before separation to measure hourly rumination and activity. Before separation, cow and calf behavior was observed by scan sampling for 15 min. During the separation process, frequency of vocalizations and turn arounds were recorded. At separation, cows were moved to an observation pen where behavior was recorded for 3 d. A CCTV camera was used to record video footage of cows within the observation pens and behavior was documented from the videos in 15 min intervals across the 3 d. Results: Before separation, industry calves were more likely to be near their mother than Treatment calves. During the separation process, vocalization and turn around behavior was similar between groups. After full separation, treatment cows vocalized three times more than industry cows. However, the frequency of time spent close to barrier, standing, lying, walking, and eating were similar between industry and treatment cows. Treatment cows had greater rumination duration, and were more active, than industry cows. Conclusion: These findings suggest a similar behavioral response to full calf separation and greater occurrence of vocalizations, from cows maintained in a long-term, pasture-based, cow-calf rearing system when ompared to cows separated within 24 h. However, further work is required to assess the impact of full separation on calf behavior.

The Effects of Discrepancy in Reconstruction Algorithm between Patient Data and Normal Database in AutoQuant Evaluation: Focusing on Half-Time Scan Algorithm in Myocardial SPECT (심근 관류 스펙트에서 Half-Time Scan과 새로운 재구성법이 적용된 정상군 데이터를 기반으로 한 정량적 분석 결과의 차이 비교)

  • Lee, Hyung-Jin;Do, Yong-Ho;Cho, Seong-Wook;Kim, Jin-Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.122-126
    • /
    • 2014
  • Purpose: The new reconstruction algorithms (NRA) provided by vendor aim to shorten the acquisition scan time. Whereas depending on the installed version AutoQuant program used for myocardial SPECT quantitative analysis did not contain the normal data that NRA is applied. Thus, the purpose of this paper is to compare the results according to AutoQuant versions in myocardial SPECT applied NRA and half-time scan (HT). Materials and Methods: Rest Tl and stress MIBI data of total 80 (40 men, 40 women) patients were gathered. Data were applied HT acquisition and ASTONISH (Philips) software which is NRA. Modified autoquant of SNUH and old version of AutoQuant (full-time scan) provided by company were compared. Comparison groups were classified as coronary artery disease (CAD), 24 hrs delay and almost normal patients who have a simple pain patient. Perfusion distribution aspect, summed stress score (SSS), summed rest score (SRS), extent and total perfusion deficit (TPD) of each 25 patient who have above diseases were compared and evaluated. Results: The case of CAD, when using re-edited AutoQuant (HT) SSS and SRS showed about 30% reduction (P<0.0001), Extent showed about 38% reduction and TPD showed about 30% reduction in the tendency (P<0.0001). In the score of the perfusion, especially on the part of infero-medium, infero-apical, lateral-medium and lateral-apical regions were the biggest change. The case of the 24 hrs delay patient SRS (P=0.042), Extent (P=0.018) and TPD (P=0.0024) showed about 13-18% reduction. And the case of simple pain patient, comparison of 4 results showed about 5-7% reduction. Conclusion: This study was started based on expectation that results could be affected by normal patient data. Normal patient data is possible to change by race and gender. It was proved that combination of new reconstruction algorithm for reducing scan time and analysis program according to scan protocol with NRA could also be affected to results. Clinical usefulness of gated myocardial SPECT is possibly increased if each hospital properly collects normal patient data for their scan acquisition protocol.

  • PDF

Application of various digital technique on full mouth rehabilitation: A case report (디지털 기술을 활용한 전악 고정성 보철 수복 증례)

  • Bae, Min-Soo;Song, Kwang-Yeob;Ahn, Seung-Geun;Park, Ju-Mi;Lee, Jung-Jin;Seo, Jae-Min
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.1
    • /
    • pp.43-54
    • /
    • 2021
  • Based on rapid improvement in digital fields, many advanced digital technologies are utilized in prosthodontic treatment. Especially, intraoral scanners and 3D printing technology are commonly used, and facial scanning technology is recently being attempted to be part of these digital routines. This case report aims to introduce a digital procedure using the intraoral scanner, facial scanner, and 3D printing technology to create definitive restorations, which are esthetic and harmonious with patient's face. From thoroughly evaluated full-mouth provisional restoration which was manufactured and fitted conventionally, definitive prostheses were fabricated using various digital technique. Stable occlusion with functionally and aesthetically satisfying results were achieved.

EMI Prediction of Slew-Rate Controlled I/O Buffers by Full-Wave and Circuit Co-Simulation

  • Kim, Namkyoung;Hwang, Jisoo;Kim, SoYoung
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.14 no.4
    • /
    • pp.471-477
    • /
    • 2014
  • In this paper, a modeling and co-simulation methodology is proposed to predict the radiated electromagnetic interference (EMI) from on-chip switching I/O buffers. The output waveforms of I/O buffers are simulated including the on-chip I/O buffer circuit and the RC extracted on-chip interconnect netlist, package, and printed circuit board (PCB). In order to accurately estimate the EMI, a full-wave 3D simulation is performed including the measurement environment. The simulation results are compared with near-field electromagnetic scan results and far-field measurements from an anechoic chamber, and the sources of emission peaks were analyzed. For accurate far-field EMI simulation, PCB power trace models considering IC switching current paths and external power cable models must be considered for accurate EMI prediction. With the proposed EMI simulation model and flow, the electromagnetic compatibility can be tested even before the IC is fabricated.