• Title/Summary/Keyword: Full-scale measurement

Search Result 204, Processing Time 0.037 seconds

Structural health rating (SHR)-oriented 3D multi-scale finite element modeling and analysis of Stonecutters Bridge

  • Li, X.F.;Ni, Y.Q.;Wong, K.Y.;Chan, K.W.Y.
    • Smart Structures and Systems
    • /
    • v.15 no.1
    • /
    • pp.99-117
    • /
    • 2015
  • The Stonecutters Bridge (SCB) in Hong Kong is the third-longest cable-stayed bridge in the world with a main span stretching 1,018 m between two 298 m high single-leg tapering composite towers. A Wind and Structural Health Monitoring System (WASHMS) is being implemented on SCB by the Highways Department of The Hong Kong SAR Government, and the SCB-WASHMS is composed of more than 1,300 sensors in 15 types. In order to establish a linkage between structural health monitoring and maintenance management, a Structural Health Rating System (SHRS) with relevant rating tools and indices is devised. On the basis of a 3D space frame finite element model (FEM) of SCB and model updating, this paper presents the development of an SHR-oriented 3D multi-scale FEM for the purpose of load-resistance analysis and damage evaluation in structural element level, including modeling, refinement and validation of the multi-scale FEM. The refined 3D structural segments at deck and towers are established in critical segment positions corresponding to maximum cable forces. The components in the critical segment region are modeled as a full 3D FEM and fitted into the 3D space frame FEM. The boundary conditions between beam and shell elements are performed conforming to equivalent stiffness, effective mass and compatibility of deformation. The 3D multi-scale FEM is verified by the in-situ measured dynamic characteristics and static response. A good agreement between the FEM and measurement results indicates that the 3D multi-scale FEM is precise and efficient for WASHMS and SHRS of SCB. In addition, stress distribution and concentration of the critical segments in the 3D multi-scale FEM under temperature loads, static wind loads and equivalent seismic loads are investigated. Stress concentration elements under equivalent seismic loads exist in the anchor zone in steel/concrete beam and the anchor plate edge in steel anchor box of the towers.

Full-scale Mock-up Measurement of a Double Glazed Window System Equipped with Sunlight Controls (광기능성 창호시스템의 동절기 채광특성에 관한 목업연구)

  • Kim, Gon
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.35-42
    • /
    • 2008
  • Besides genuine skin and clothes, it is called that building is third skin for us. That means the skin of buildings is the most important factor for our man-made environment. The issues in designing the building envelope include the insulation, infiltration, ventilation and bridging in windows. Getting light into the space safely and providing views to outdoor, additionally, are key things with the building envelope design. A deep-rooted preference for full view is still alive with large area of glass. Balcony expansion is legalized in apartment houses, which causes lots of environmental problems. Without balcony space, the adjacent space to unshaded window is exposed to the direct sun. A window can have many layers and the inner space can be utilized with an automatic blind system. Recently, the refurbished version of a double-glazed window system has been developed for the purpose of minimizing energy loss occurred around windows. For the better daylight control with equipped blind system, a set of adjustment technique of blind slats was tested in a mock-up building and recommended the detail operation. Not surprisingly, the optimized blind system can be oriented to enhance the uniformity in light distribution and direct glare from the sky as well..

Examining the Effect of L/W Ratio on the Hydro-dynamic Behavior in DAF System Using CFD & ADV Technique (전산유체역학과 ADV기술을 이용한 장폭비의 DAF조내 수리흐름에 미치는 영향 연구)

  • Park, No-Suk;Kwon, Soon-Bum;Lee, Sun-Ju;Bae, Chul-Ho;Kim, Jeong-Hyun;Ahn, Hyo-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.4
    • /
    • pp.421-428
    • /
    • 2005
  • Dissolved air flotation (OAF) is a solid-liquid separation system that uses fine bubbles rising from bottom to remove particles in water. In this study, we investigated the effect of L/W (L; Length, W; Width) on the hydro-dynamic behavior in DAF system using CFD (Computational Fluid Dynamics) and ADV (Acoustic Doppler Velocimetry) technique. The factual full-scale DAF system, L/W ratio of 1:1, was selected and various L/W ratio (2:1, 3:1, 4:1 and 5:1) conditions were simulated with CFD. For modelling, 2-phase (gas-liquid) flow equations for the conservation of mass, momentum and turbulence quantities were solved using an Eulerian-Eulerian approach based on the assumption that very small particle is applied in the DAF system. Also, for verification of CFD simulation results, we measured the factual velocity at some points in the full-scale DAF system with ADV technique. Both the simulation and the measurement results were in good accordance with each other. As the results of this study, we concluded that L/W ratio and outlet geometry play important role for flow pattern and fine bubble distribution in the flotation zone. In the ratio of 1:1, the dead zone is less than those in other cases. On the other hands, in the ration of 3:1, the fine bubbles were more evenly distributed.

The Comparative Experiment of Geogrid Reinforcement Types with Construction Stage on Segmental Retaining Walls (블록식 보강토 옹벽에서의 시공단계별 보강재 타입에 따른 거동비교)

  • Lee, Sung-Hyouk;Lee, Jin-Wook;Choi, Chan-Yong
    • Journal of the Korean Geosynthetics Society
    • /
    • v.11 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • In this study, the earth pressure, displacement and strain were compared with reinforcement types at segmental retaining wall through full scale model test. The test results found that the measurement of earth pressure and displacement at wall for the fully reinforced retaining wall are different from those for the partly reinforced retaining wall. The analyses of these results would suggest that the used of geoogrid allowed the vertical earth pressure and displacement at wall to be reduced. The horizontal earth pressure in upper and lower part of wall can change with reinforcement type and earth deformation and were larger than the active and the rest pressure. Also, the lateral earth pressure and displacement of wall have a very high a correlation. It was found that the strain contour distribution of reinforcements was occurred a large strain at cental part of wall in segmental retaining wall system.

Implementation of Successive Approximate Register typed A/D Converter for a Monitored Battery Voltage Conversion (모니터링된 배터리 전압 변환을 위한 SAR typed A/D 컨버터의 제작)

  • Kim, Seong-Kweon;Lee, Kyung-Ryang;Yeo, Sung-Dae;Hong, Justin S.Y.;Park, Yong-Eun
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.6 no.2
    • /
    • pp.256-261
    • /
    • 2011
  • In this paper, a design and an implementation of an Analog to Digital (A/D) converter are introduced for the conversion of monitored battery cell voltage in the cell voltage monitoring(CVM) system in battery management system(BMS), which is one of the key devices of ECO hybrid cars. The A/D converter in CVM system required a middle conversion speed and a high resolution, therefore, a successive approximate register(SAR) typed A/D converter with 10 bits resolution has been designed and implemented using Magna 0.6um 40V process. The measurement result which kept ${\pm}1$ LSB accuracy in the full scale range(FSR) of 5V, showed the usefulness of the SAR typed A/D converter in realizing a CVM system.

Evaluation of the Effect of Sedimentation Basin Structure on Hydrodynamic Behavior Using CFD (II): The Effect of Trough (CFD를 이용한 침전지 구조가 수리거동에 미치는 영향 평가(II): 트라프의 영향 중심으로)

  • Park, No-Suk;Lim, Jae-Lim;Lee, Sun-Ju;Kwon, Soon-Bum;Min, Jin-Hui
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.6
    • /
    • pp.758-766
    • /
    • 2005
  • This study was conducted to evaluate the effect of the transverse troughs on hydrodynamic behavior within the a certain full-scale sedimentation basin (flow rate/one basin; $10,000m^3/d$) using CFD simulation and ADV technique. In order to verify the CFD simulation, we measured the factual velocity at 36 points in the full-scale sedimentation basin, whose outlet structure is inadequate, with ADV technique. Both the CFD simulation and the ADV measurement results were in good accordance with each other. From the CFD simulation results of the existing basin, it was investigated that extreme upward flow occurs in the near of two transverse troughs. It was suspected that since the transverse troughs converted the open channel flow into the local closed pipe flow, the increased pressure in this local closed pipe flow region made the extreme upward flow. For solving this problems, it was suggested to modify transverse-typed launder into finger-typed launder and to install a longitudinal baffle in the center in this study. The CFD simulation results of all suggested amendments told us that the extreme upward flow, had occurred especially in the beneath of transverse troughs, was much less in the case of finger typed launder basin than that in the existing basin. Also, it was predicted that installing a longitudinal baffle made the fully developed flow which is more effective for sedimentation.

3D Modelling Shape Embodiment and Efficiency Analysis of Reservoir that using RTK-GPS and E/S (RTK-GPS와 E/S를 이용한 저수지의 3D 모델링 형상 구현과 효율성 분석)

  • Lee, Jae-One;Park, Un-Yong;Yang, Young-Bo;Kim, Yong-Suk
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.13 no.1 s.31
    • /
    • pp.11-17
    • /
    • 2005
  • A lot of small-scale reservoirs that is extravagant in whole country are controlled state or real condition that correct data about the practice contents is not equipped all up to now. In this study, YungNam districts that region Gyeong-Ju city reservoir is distributed much of when flow speedily choose 23 peace among 73 small scale reservoir and experimented. Acquired data every 5 seconds, and user E/S and user value TS for orthocenter to 1 second interval and executes present condition measurement using RTK-GPS. Could was wave and state that reservoir of 15 places (about 65%) gives protective care that do 3D modelling with acquired data, and now correct contents about reservoir state past through comparative analysis with data. Also, area of full water and wave that analyze effective storage and area of full water of 23 places reservoir could know that 20.63%, effective storage decreased as 3.34%. I wish to contribute about analysis about present reservoir state through this and method the adminstration direction.

  • PDF

fabrication of DMMP Thick Film Gas Sensor Based on SnO2 (산화주석을 기반으로 한 DMMP 후막가스센서 제작)

  • 최낙진;반태현;곽준혁;백원우;김재창;허증수;이덕동
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.16 no.12S
    • /
    • pp.1217-1223
    • /
    • 2003
  • Nerve gas sensor based on tin oxide was fabricated and its characteristics were examined. Target gas is dimethyl methyl phosphonate(C$_3$ $H_{9}$ $O_3$P, DMMP) that is simulant gas of nerve gas. Sensing materials were Sn $O_2$ added a-Al$_2$ $O_3$ with 0∼20wt.% and were physically mixed each material. They were deposited by screen printing method on alumina substrate. The sensor device was consisted of sensing electrode with interdigit(IDT) type in front and a heater in back side. Total size of device was 7${\times}$10${\times}$0.6㎣. Crystallite size & phase identification and morphology of fabricated Sn $O_2$ powders were analyzed by X-ray diffraction and by a scanning electron microscope, respectively. Fabricated sensor was measured as flow type and resistance change of sensing material was monitored as real time using LabVIEW program. The best sensitivity was 75% at adding 4wt.% $\alpha$-Al$_2$ $O_3$, operating temperature 30$0^{\circ}C$ to DMMP 0.5ppm. Response and recovery time were about 1 and 3min., respectively. Repetition measurement was very good with $\pm$3% in full scale.TEX>$\pm$3% in full scale.

Using neural networks to model and predict amplitude dependent damping in buildings

  • Li, Q.S.;Liu, D.K.;Fang, J.Q.;Jeary, A.P.;Wong, C.K.
    • Wind and Structures
    • /
    • v.2 no.1
    • /
    • pp.25-40
    • /
    • 1999
  • In this paper, artificial neural networks, a new kind of intelligent method, are employed to model and predict amplitude dependent damping in buildings based on our full-scale measurements of buildings. The modelling method and procedure using neural networks to model the damping are studied. Comparative analysis of different neural network models of damping, which includes multi-layer perception network (MLP), recurrent neural network, and general regression neural network (GRNN), is performed and discussed in detail. The performances of the models are evaluated and discussed by tests and predictions including self-test, "one-lag" prediction and "multi-lag" prediction of the damping values at high amplitude levels. The established models of damping are used to predict the damping in the following three ways : (1) the model is established by part of the data measured from one building and is used to predict the another part of damping values which are always difficult to obtain from field measurements : the values at the high amplitude level. (2) The model is established by the damping data measured from one building and is used to predict the variation curve of damping for another building. And (3) the model is established by the data measured from more than one buildings and is used to predict the variation curve of damping for another building. The prediction results are discussed.

3D Modelling Shape Embodiment and Efficiency Analysis of Reservoir (저수지의 3D 모델링 형상 구현과 효율성 분석)

  • Song, Youn-Kyung;Hong, Soon-Hyun;Hong, Jung-Soo
    • Journal of the Korean Geophysical Society
    • /
    • v.9 no.2
    • /
    • pp.113-120
    • /
    • 2006
  • A lot of small-scale reservoirs that is extravagant in whole country are controlled state or real conditionthat correct data about the practice contents is not equipped all up to now. In this study, YungNam districts that region Gyeong-Ju city reservoir is distributed much of when flow speedily choose 23 peace among 73 small scale reservoir and experimented. Acquired data every 5 seconds, and user E/S and user value TS for orthocenter to 1 second interval and executes present ondition measurement using RTK-GPS. Could was wave and state that reservoir of 15 places (about 65%) gives protective care that do 3D modelling with acquired data, and now correct contents about reservoir state past through comparative analysis with data. Also, area of full water and wave that analyze effective storage and area of full water of 23 places reservoir could know that 20.63%, effective storage decreased as 3.34%. I wish to contribute about analysis about present reservoir state through this and method the adminstration direction.

  • PDF