• Title/Summary/Keyword: Full-PACS

Search Result 25, Processing Time 0.029 seconds

Implementation of MINI-PACS using the DICOM Converter on the Web (DICOM Converter를 이용한 웹상에서의 MINI-PACS 구현)

  • Ji, Youn-Sang
    • Journal of radiological science and technology
    • /
    • v.23 no.1
    • /
    • pp.103-111
    • /
    • 2000
  • In recent years, medical procedures have become more complex, while financial pressures for shortened hospital stays and increased efficiency in patient care have increased. As a result, several shortcomings of present film-based systems for managing medical images have become apparent. Maintaining film space is labor intensive and consumes valuable space. Because only single copies of radiological examinations exist, they are prone to being lost or misplaced, thereby consuming additional valuable time and expense. In this paper, MINI-PACS for image archiving, transmission, and viewing offers a solution to these problems. Proposed MINI-PACS consists of mainly four parts such as Web Module, Client-Server Module, Internal Module, Acquisition Module. In addition, MINI-PACS system includes DICOM Converter that Non-DICOM file format converts standard file format. In Client-Server Module case, Proposed system is combined both SCU(Service Class User: Client) part and SCP(Service Class Provider: Server)part therefore this system provides the high resolution image processing techniques based on windows platform. Because general PACS system is too expensive for Medium and Small hospitals to install and operate the full-PACS. Also, we constructed Web Module for database connection through the WWW.

  • PDF

Design of Departmental PACS for DICOM Data Management (DICOM 데이터관리를 위한 Departmental PACS 설계)

  • Kim, Sung-Hyun;Jeon, Jae-Hwan;Kim, Gwan-Hyung;Kang, Sung-In;Oh, Am-Suk
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2010.07a
    • /
    • pp.187-189
    • /
    • 2010
  • 본 논문에서는 현재 의료부분에 많은 혜택을 주는 PACS라는 시스템을 중소병원에 맞게 설계하였다. PACS는 초기 도입 비용과 불확실한 투자효과에 의해서 많은 개인, 중소병원들이 도입하기 어려워하는 시스템 중 하나였다. 그러한 문제점으로 현재 대형병원에서만 사용 중인 PACS를 중소 병원급 PACS 시스템으로 연구하는데 있다. 본 논문에서는 기존의 병원 정보 시스템을 수용하면서도 Full PACS의 네트워크 관리모듈의 비중과 시스템 연동을 위한 WorkList Server 기능을 제한하고 특정기기에 대한 생산성 향상을 목적으로 전체가 아닌 단위별로 운영되는 중소병원용 Departmental PACS에 대해 기술하였다.

  • PDF

Design and Implementation of Web-Based MINI-PACS using the DICOM (DICOM을 이용한 웹 기반 MINI-PACS 설계 및 구현)

  • 지연상;이성주
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.4 no.5
    • /
    • pp.1095-1104
    • /
    • 2000
  • In recent years, medical procedures have become more complex, while financial pressures for shortened hospital stays and increased efficiency in patient care have increased. As a result, several shortcomings of present film-based systems for managing medical images have become apparent. Maintaining film space is labor intensive and consumes valuable space. Because only single copies of radiological examinations exist, they are prone to being lost or misplaced, thereby consuming additional valuable time and expense. In this paper, mini-PACS for image archiving, transmission, and viewing offers a solution to these problems. Proposed mini-PACS consists of mainly four parts such as web module, client-server module, internal module, acquisition module. In addition, mini-PACS system includes DICOM converter that non-DICOM file format converts standard file format. In client-server module case, proposed system is combined both SCU (service class user: client) part and SCP(service class provider: sewer)part therefore this system provides the high resolution image processing techniques based on windows platform. Because general PACS system is too expensive for medium and small hospitals to install and operate the full-PACS. Also, we constructed web module for database connection through the WWW.

  • PDF

Implementation ANY-PACS Using Web Module and DICOM Converter on the windows platform (윈도우 플랫폼 상에서 Web Module 과 Converter를 이용한 Any-PACS 구현)

  • Yoon, Min-Jong;Lee, Joon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.05a
    • /
    • pp.93-98
    • /
    • 1999
  • In recent years, medical procedures have become more complex, while financial pressures for shortened hospital stays and increased efficiency in patient care have increased. As a result, several shortcomings of present film-based systems for managing medical images have become apparent. Maintaining film space is labor intensive and consumes valuable space. Because only single copies of radiological examinations exist, they are prone to being lost or misplaced, thereby consuming additional valuable time and expense. In this paper, Any-PACS for image archiving, transmission, and viewing offers a solution to these problems. Proposed Any-PACS consists of mainly four parts such as Web Module, Client-Server Module, Internal Module, Acquisition Module. In addition, Any-PACS system includes DICOM Converter that Non-DICOM file format converts standard file format. In Client-Server Module case, Proposed system is combined both SCU(Service Class Use: Client) part and SCP(Service Class provider: Server)part therefore this system provides the high resolution image processing techniques based on windows platform. Because general PACS system is too expensive for Medium and Small hospitals to install and operate the full-PACS. Also, we constructed Web Module for database connection through the WWW.

  • PDF

A Study on Reduction Effect of Processing Wastewater by Introduction of PACS (PACS 도입에 의한 현상시스템 폐수 감소효과에 관한 연구)

  • Ko, Shin-Kwan;Han, Dong-Kyoon;Kim, Wook-Dong;Kang, Bung-Sam;Yang, Han-Jun
    • Journal of radiological science and technology
    • /
    • v.30 no.2
    • /
    • pp.167-175
    • /
    • 2007
  • There are some positive effects by the introduction of PACS(Picture Archiving Communication System). This study is to analyze the mutual relation between before and after of the introduction of PACS in terms of the environment effect. It is supposed to cause the reduction of developing and fixing wastewater according to the increase in the rate of a non-film. This study will also show the amount of wastewater. Target places were the department of image medicine(diagnostic radiation) of the general hospitals in Seoul and Gyeonggi-Do, which are equiped with full PACS. The authors examined questionnaires on the number of projection, the number of indirect projection, the amount of the film used, the number of radiation image CD loan, the amount of the developing and fixing solution used, the change of the amount of fixing wastewater. According to the analysis, we analyzed the change of the amount of developing and fixing solution per a film and the change of the amount of developing and fixing wastewater which is supposed to be reduced proportionally by the introduction of PACS. We got conclusion as below after analyzing 8 hospitals except the largest and the least amount of examination, film used, developing and fixing solution and the amount of developing and fixing wastewater in order to decrease the deviation from 10 general hospitals located in Seoul and Gyeonggi-Do. We compared data one year before adopting PACS Versus 3 years after adopting PACS. 1. The frequences of examination increased to 7,357.7 cases per month but the amount of film used decreased to 90%, from 42,774.4 to 4,181.88 after adopting the PACS. 2. 3 years after adopting PACS, monthly average amount of developing solution used decreased to 92% and the monthly average amount of fixing solution decreased to 86%. 3. Monthly average amount of developing solution used per film increased to 1.49 times and fixing solution increased as much as three times. 4. Monthly average wastewater for developing decreased to 88% and wastewater for fixing decreased up to 87%. 5. Monthly average wastewater for developing per film increased to 3.77 times and wastewater for fixing increased to 3.85 times. Although the amount of film used and the amount of developing and fixing wastewater affected by the reduction of the developing and fixing solution became less on the whole by introduction of PACS, they did not decrease proportionally. Moreover the amount of the developing and fixing solution used and the amount of developing and fixing wastewater per a film increased. That means the expectation for an environmental improvement differs from the actual condition.

  • PDF

Application of MicroPACS Using the Open Source (Open Source를 이용한 MicroPACS의 구성과 활용)

  • You, Yeon-Wook;Kim, Yong-Keun;Kim, Yeong-Seok;Won, Woo-Jae;Kim, Tae-Sung;Kim, Seok-Ki
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.51-56
    • /
    • 2009
  • Purpose: Recently, most hospitals are introducing the PACS system and use of the system continues to expand. But small-scaled PACS called MicroPACS has already been in use through open source programs. The aim of this study is to prove utility of operating a MicroPACS, as a substitute back-up device for conventional storage media like CDs and DVDs, in addition to the full-PACS already in use. This study contains the way of setting up a MicroPACS with open source programs and assessment of its storage capability, stability, compatibility and performance of operations such as "retrieve", "query". Materials and Methods: 1. To start with, we searched open source software to correspond with the following standards to establish MicroPACS, (1) It must be available in Windows Operating System. (2) It must be free ware. (3) It must be compatible with PET/CT scanner. (4) It must be easy to use. (5) It must not be limited of storage capacity. (6) It must have DICOM supporting. 2. (1) To evaluate availability of data storage, we compared the time spent to back up data in the open source software with the optical discs (CDs and DVD-RAMs), and we also compared the time needed to retrieve data with the system and with optical discs respectively. (2) To estimate work efficiency, we measured the time spent to find data in CDs, DVD-RAMs and MicroPACS. 7 technologists participated in this study. 3. In order to evaluate stability of the software, we examined whether there is a data loss during the system is maintained for a year. Comparison object; How many errors occurred in randomly selected data of 500 CDs. Result: 1. We chose the Conquest DICOM Server among 11 open source software used MySQL as a database management system. 2. (1) Comparison of back up and retrieval time (min) showed the result of the following: DVD-RAM (5.13,2.26)/Conquest DICOM Server (1.49,1.19) by GE DSTE (p<0.001), CD (6.12,3.61)/Conquest (0.82,2.23) by GE DLS (p<0.001), CD (5.88,3.25)/Conquest (1.05,2.06) by SIEMENS. (2) The wasted time (sec) to find some data is as follows: CD ($156{\pm}46$), DVD-RAM ($115{\pm}21$) and Conquest DICOM Server ($13{\pm}6$). 3. There was no data loss (0%) for a year and it was stored 12741 PET/CT studies in 1.81 TB memory. In case of CDs, On the other hand, 14 errors among 500 CDs (2.8%) is generated. Conclusions: We found that MicroPACS could be set up with the open source software and its performance was excellent. The system built with open source proved more efficient and more robust than back-up process using CDs or DVD-RAMs. We believe that the operation of the MicroPACS would be effective data storage device as long as its operators develop and systematize it.

  • PDF

The Research on Compression Image Quality of Full Field Digital Mammography on PACS Environment (PACS환경에서 Full Field Digital Mammography 영상의 압축 화질평가에 관한 연구)

  • Jeong, Jaeho;Kim, Eunsoo
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.4
    • /
    • pp.147-153
    • /
    • 2014
  • We tried to assessment about characteristics of image through quantitative evaluation method and qualitative evaluation method in Full Field Digital Mammography. It satisfied an approval standard of ten score regardless of compression ratio measuring detection score after compressing and appling an algorithm of JPEG2000 orJPEG compression targeting ACR accreditation phantom. Also, it was apparent that when we selected and compressed the image of real fine lesion and measured a change of diagnosis ability magnifing over 50 percent after compressing over 20:1 ratio, it had a strong influence on diagnosis ability. We realized that the difference between the original image according to compression ratio measuring a quantitative evaluation which is PSNR,RMSE,MAE and SSIM was relatively allowable.

A Performance Evaluation of Diagnostic Display System by AAPM TG18 (AAPM TG18에 의한 진단용 CRT 디스플레이 시스템의 성능 평가)

  • Kim, H.J.;Jung, H.J.;Min, D.K.;Hong, J.O.;Kim, Y.N.
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.6 no.1
    • /
    • pp.9-18
    • /
    • 2003
  • 디지털 영상 검출기와 디스플레이 기술의 발달과 의료영상전달시스템(PACS)의 출현은 전통적 필름방식에 비하여 디지털 방식으로 방사선과 영상을 획득하고 전송, 저장하는 매우 효과적인 수단을 제공하고 있다. 2002년 8월, 연세의료원 세브란스병원은 진단 영상 판독 목적으로 18 대의 CRT(Braco View, Belgium)와 32대의 평판 LCD(Totoku Electric Co., Ltd., Japan) 디스플레이 장치를 GE full-PACS(GE 메디칼시스템코리아 : GEMSK)와 연계하여 설치 완료하였다. 본 연구에서, 기하학적 왜곡, 반사, 휘도 반응, 휘도 균일도, 분해능, 노이즈,베일링 글레어, 칼라 균일도 항목들을 AAPM TG18 보고서 9.0에 따라서 시각적 그리고 부분적으로는 정량적인 방법으로 인수검사를 실시하여 보고한다. 사용된 장비는 색도계로도 사용되는 간편한 휘도계, TG18 테스트 패던, AAPM Tg18 AT plug-in software(Barco View Ltd., Kortrijk, Belgium)이었다. 칼라 균일도를 제외한 모든 테스트 결과는 AAPM TG18에서 권고하는 기준에 일치하였으며 진단 영상 판독에 사용하기에 전적으로 수락할 수 있는 성능이었다. 결론으로, 사용된 인수검사는 단지 인수 검사 표준을 제공하는 것 뿐만 아니라 품질검사(QC)의 지침, 판독 환경의 최적화 그리고 교체 시기나 업그레이드 시기를 결정하여주는 중요한 역할을 할 수 있을 것이다.

  • PDF

Applicability of the Krško nuclear power plant core Monte Carlo model for the determination of the neutron source term

  • Goricanec, Tanja;Stancar, Ziga;Kotnik, Domen;Snoj, Luka;Kromar, Marjan
    • Nuclear Engineering and Technology
    • /
    • v.53 no.11
    • /
    • pp.3528-3542
    • /
    • 2021
  • A detailed geometrical model of a Krško reactor core was developed using a Monte Carlo neutron transport code MCNP. The main goal of developing an MCNP core model is for it to be used in future research focused on ex-core calculations. A script called McCord was developed to generate MCNP input for an arbitrary fuel cycle configuration from the diffusion based core design package CORD-2, taking advantage of already available material and temperature data obtained in the nuclear core design process. The core model was used to calculate 3D power density profile inside the core. The applicability of the calculated power density distributions was tested by comparison to the CORD-2 calculations, which is regularly used for the nuclear core design calculation verification of the Krško core. For the hot zero power and hot full power states differences between MCNP and CORD-2 in the radial power density profile were <3%. When studying axial power density profiles the differences in axial offset were less than 2.3% for hot full power condition. To further confirm the applicability of the developed model, the measurements with in-core neutron detectors were compared to the calculations, where differences of 5% were observed.