• Title/Summary/Keyword: Full edentulous

Search Result 84, Processing Time 0.02 seconds

Full mouth rehabilitation in patient with loss of vertical dimension and deep bite due to worn dentition (전반적인 치아의 마모로 인한 수직고경 감소와 과피개교합을 갖는 환자의 전악 수복 증례)

  • Nam, Ki-Hun;Park, Pil-Kou;Kim, Hee-Kyung;Kang, Jeong-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.54 no.1
    • /
    • pp.65-71
    • /
    • 2016
  • Gradual occlusal attrition is a normal process of aging. However, severe attrition causes pathogenic pulp, occlusal disharmony, functional disorder and esthetic problems. Alteration of vertical dimension should be considered for space regaining for tooth restoration, esthetic improvement or correction of occlusal relationship. Vertical dimension should be determined within the range of minimal invasive process satisfying patient's esthetic requirements and operator's functional goal. And patient's adaptation to newly determined vertical dimension should be assessed simultaneously. Deep overbite is not a simple problem of overbite, instead it is an usually complicated problem with anterior-posterior occlusal relationship. Considering these facts, appropriate restoration of edentulous part as well as improvement of anterior-posterior relationship should be performed to solve this fundamental problems. In this study, a 67 year-old male patient with many worn teeth and loss of posterior teeth was treated with removable partial denture at edentulous mandibular area to increase vertical dimension and fixed prostheses at dentulous maxillary and mandibular area. With these treatments, we attained a satisfactory result in functional and esthetic aspects as a report case.

Full-mouth rehabilitation using digital method to transfer provisional restoration to final fixed implant restoration (디지털 방법을 활용하여 임시수복물을 최종 고정성 임플란트 수복물로 이행한 완전 구강 회복 증례)

  • Cho, Eunhan;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock;Noh, Kwantae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.4
    • /
    • pp.362-373
    • /
    • 2022
  • For a full-mouth fixed prosthetic treatment of the edentulous patient, it is essential to confirm the proper tooth position and thorough evaluation of the remaining alveolar bone and soft tissue before surgery. CAD-CAM dentistry and guided implant surgery have such advantages of providing simultaneous planning of surgery and prosthetic treatment to ensure pre-knowledge of the treatment. In this clinical case, using the digital technology, digital temporary denture fabrication, esthetic evaluation before fixed prostheses treatment, and guided surgery planning was possible. After the surgery, previously obtained data was used for fabricating fixed temporary prostheses. Definitive zirconia prostheses transferred from the provisional prostheses were fabricated and functionally and esthetically satisfying results were obtained.

Full mouth rehabilitation in partially edentulous patient with an unstable mandibular position (불안정한 하악위를 가진 부분 무치악 환자에서 전악 수복 증례)

  • Donghwi Yook;Younghoo Lee;Seoung-Jin Hong;Ahran Pae;Kwantae Noh;Hyeong-Seob Kim;Kung-Rock Kwon;Janghyun Paek
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.61 no.4
    • /
    • pp.308-315
    • /
    • 2023
  • In the case of a patients who have lost the centric stop and have a staggered occlusion of the residual teeth, various movements occur when the denture is loaded. Implant placement is necessary to reinforce the retention, support, and stabilization elements to reduce denture movement. However, in this case, considering the patient's age, aversion to surgery, and bone loss, implants were not placed and restoration was performed with a removable partial denture. In this case, it is important to set the correct mandibular position for restoration because the patient has a habit of chewing with the remaining teeth. In this case, a stable mandibular position was established using a gothic arch tracing, and good results were obtained by restoring with partial dentures, so this is reported.

RELIABILITY OF SPIRAL TOMOGRAPHY FOR IMPLANT SITE MEASUREMENT OF THE MANDIBLE (하악골 매식 부위 계측을 위한 나선형 단층촬영술의 신뢰도)

  • Kim Kee-Deog;Park Chang-Seo
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.27 no.2
    • /
    • pp.27-47
    • /
    • 1997
  • The purpose of this study was to evaluate the accuracy and usefulness of spiral tomography through the comparison and analysis of SCANORA cross-sectional tomographs and DentaScan computed tomographic images of dry mandibles taken by a SCANORA spiral tomographic machine and a computed tomographic machine. Thirty-one dry mandibles with full or partial edentulous areas were used. To evaluate the possible effect of location in the edentulous area, it was divided into 4 regions of Me (region of mental foramen), MI (the midportion between Me and M2), M2 (the midportion between mental foramen and mandibular foramen) and S (the midportion of the mandibular symphysis). A ZPC column (sized 4 mm x 5 mm) was seated on the edentulous regions of Me, MI, M2 and S using the acrylic stent. Then SCANORA spiral tomography and computed tomography were taken on the edentulous regions which contained the ZPC column. The ZPC columns and cross-sectional images of the mandible were measured in the radiographs by three observers and the differences between the two imaging modalities were analysed. The results were as follows: 1. In comparing the actual measurements of the ZPC column and measurements in the radiographs, the mean error of the DentaScan computed tomography was 0.07 mm in vertical direction and -0.06 mm in horiwntal direction, while the mean error of the SCANORA spiral tomography was 0.06 mm in vertical direction and -0.12 mm in horizontal direction. There was a significant difference between the two radiographic techniques in the horizontal measurement of the ZPC column of the symphysis region (p<0.05). But there was no significant difference in the measurements of other regions (p>0.05). 2. In measurements of the distance from the alveolar crest to the inferior border of the mandible (H), and of the distance from the alveolar crest to the superior border of the mandibular canal (Y), there was no significant difference between the two radiographic techniques (p>0.05). 3. In measurements of the distance from the lingual border of the mandible to the buccal border of the mandible (W), and of the distance from the lingual border of the mandible to the lingual border of the mandibular canal (X), there was a significant difference between the two radiographic techniques in measurements of the midportion between the mental foramen and the mandibular foramen (M2) (p<0.05). But there were no significant differences in measurements of the other regions of symphysis (S), mental foramen (Me), the first one-fourth portion between the mental foramen and the mandibular foramen (M1) (p>0.05). 4. Considering the mean range of measurements between observers, the measurements of SCANORA spiral tomography showed higher value than those of DentaScan computed tomography, except in measurements of symphysis (S). 5. On the detectability of the mandibular canal, there was no significant difference between the two radiographic techniques (p>0.05). In conclusion, SCANORA spiral tomography demonstrated a higher interobserver variance than that of DentaScan computed tomography for implant site measurements in the posterior edentulous area of the mandible. These differences were mainly the result of difficulty in the detection of the border of the mandible in SCANORA spiral tomography. But considering the cost and the radiation exposure, SCANORA spiral tomography can be said to be a relatively good radiographic technique for implant site measurement.

  • PDF

A case of full mouth rehabilitation in patient with loss of vertical dimension and deep bite due to tooth wear (치아 마모로 인한 수직고경감소와 과개교합을 가진 환자에서 전악 수복 증례)

  • Seo, Seong-Yong;Lee, Na-Young;Kang, Jeong-Kyung
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.56 no.1
    • /
    • pp.31-39
    • /
    • 2018
  • The collapse of the posterior occlusion destroys the normal occlusal plane and causes excessive wear reducing the vertical dimension. Reduced vertical dimension of occlusion causes not only aesthetic and functional problems but also overloading on the temporomandibular joints and abnormalities of muscle nerve system. In order to improve the collapsed occlusal relationship, it is necessary to consider the change of the vertical dimension. It is necessary to make a precise diagnosis and analysis before the treatment and to evaluate the adaption of patient to the new vertical dimension of occlusion. A patient with excessive overbite often has occlusal problems of tooth wear and tooth eruption. Considering these considerations, overall prosthodontic restoration is required to solve the problem. A patient of 68 year old man in this case who suffered major tooth wear and maxillary posterior teeth loss was treated with elevation of vertical dimension of occlusion by maxillary removable dental prosthesis and mandibular fixed prosthesis.

Full mouth rehabilitation of the patient with crossed occlusion using removable partial denture restoration: A case report (엇갈린 교합 환자에서의 가철성 보철을 이용한 전악구강회복 증례)

  • Choi, Yu-Ra;Kang, Jeong-Kyung;Kim, Na-Hong;Chang, Hee-Won
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.55 no.1
    • /
    • pp.38-45
    • /
    • 2017
  • In removable partial denture with crossed occlusion, it is difficult to meet the satisfaction of patient due to variable movement of denture and unfavorable stability under loading. In a case with few unilaterally teeth remaining, additional treatments such as implantation or residual root are required to assure bilaterally stable support. However, due to the medical condition of the patient with hypertension, angina and old age etc., removable partial denture was planned as treatment in this case. Proper diagnosis, accurate analysis and full understanding of the adaptation for neuromuscular system are necessary to recover the vertical dimension of patient from a decreased vertical dimension due to crossed occlusion.

Reliability and validity of Korean version of the OHIP for edentulous subjects: A pilot study (무치악 환자들을 위한 한국어 버전의 구강건강영향지수 신뢰도와 타당성 평가를 위한 모의연구)

  • Shin, Jae Seob;Bae, So Young;Park, Jin Hong;Shim, Ji Suk;Lee, Jeong Yol
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.59 no.3
    • /
    • pp.305-313
    • /
    • 2021
  • Purpose. The purpose of this pilot study is to evaluate the reliability and validity of the Korean version of the oral health impact profile (OHIP-EDENT K) for edentulous patients. Materials and methods. The study was conducted on 12 patients who fabricated overdenture in the Department of Prosthodontics, Korea University, Guro Hospital. All subjects completed the Korean version of Oral Health Impact Profile (OHIP K) questionnaire. Shorten version of the OHIP called OHIP-14 K and OHIP-EDENT K were derived from the datasets. Cronbach's alpha was used to measure internal consistency of the summary scores for OHIP-EDENT K. The Spearman's correlation coefficient between the summary scores for OHIP-EDENT K and OHIP K was calculated to evaluate concurrent validity. Results. The reliability of the summary scores for OHIP-EDENT K was acceptable (α=.736). The Spearman's correlation coefficient of the summary scores for OHIP-EDENT K and OHIP K was 0.966, which was statistically significant (P<.001). OHIP-EDENT K exhibited less susceptibility to floor effects than OHIP-14 K and appeared to measure change as effectively as OHIP K. In order to prove the reliability, responsiveness and validity of OHIP-EDENT K, further studies with more samples are needed. Conclusion. The OHIP-EDENT K, a questionnaire on oral health-related QOL comprising 19 items, has measurement properties comparable with the full 49-item version. This modified shortened version can be an alternative questionnaire to full version of OHIP K and OHIP-14 K in edentulous patients.

Finite element analysis on stress distribution of maxillary implant-retained overdentures depending on the Bar attachment design and palatal coverage

  • Kim, Min-Jeong;Hong, Sung-Ok
    • The Journal of Advanced Prosthodontics
    • /
    • v.8 no.2
    • /
    • pp.85-93
    • /
    • 2016
  • PURPOSE. The purpose of this study was to determine the effect of anchorage systems and palatal coverage of denture base on load transfer in maxillary implant-retained overdenture. MATERIALS AND METHODS. Maxillary implant-retained overdentures with 4 implants placed in the anterior region of edentulous maxilla were converted into a 3-D numerical model, and stress distribution patterns in implant supporting bone in the case of unilateral vertical loading on maxillary right first molar were compared with each other depending on various types of anchorage system and palatal coverage extent of denture base using three-dimensional finite element analysis. RESULTS. In all experimental models, the highest stress was concentrated on the most distal implant and implant supporting bone on loaded side. The stress at the most distal implant-supporting bone was concentrated on the cortical bone. In all anchorage system without palatal coverage of denture base, higher stresses were concentrated on the most distal implant and implant supporting bone on loaded side. CONCLUSION. It could be suggested that when making maxillary implant retained overdenture, using Hader bar instead of milled bar and full palatal coverage rather than partial palatal coverage are more beneficial in distributing the stress that is applied on implant supporting bone.

A VITRO STUDY OF RETAINED SCREW STABILITY BY VARIOUS CONNECTION DESIGNS BETWEEN FIXTURE AND ABUTMENT IN IMPLANT DENTISTRY (임플란트 고정체와 지대주 연결 형태의 차이에 따른 유지 나사 안정성에 대한 연구)

  • Yang Jae-Sik;Vang Mong-Sook;Jo Gyu-Jong
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.42 no.1
    • /
    • pp.83-93
    • /
    • 2004
  • Statement of problem : Since the concept of osseointegrated dental implant by $Br{\aa}nemark$ et al was first applied to mandibular full edentulous patients. Recently it is considerated the first treatment option on missing teeth. A common problem associated with dental implant restorations is loosening of screws that retain the prosthesis to the abutment and the abutment to the implant fixture. Purpose : This study is to examine the influence on screw loosening of implant-abutment designs. Material and methods : External hex, cone screw, beveled hex, cam cylinder, cylinder hex by means of evaluating the loosening torques, with respect to a range of tightening torques after repeated loading. Result : 1. Cone screw, beveled hex groups are the highest initial tightening rate and cylinder hex, external hex groups are the lowest initial tightening rate (p < 0.05). 2. Cone screw groups are the highest after repeated loading tightening rate and cylinder hex groups are lowest after repeated loading tightening rate(p < 0.05). 3. Cone screw groups have the highest initial stability and anal stability. 4. All groups are decreased tightening rate after repeated loading.

Clinical application of bone graft materials in dental implant (임상가를 위한 특집 3 - 기능별 뼈이식재의 임프란트 적용방법)

  • Ahn, Kang-Min
    • The Journal of the Korean dental association
    • /
    • v.48 no.4
    • /
    • pp.275-279
    • /
    • 2010
  • Dental implant restoration in partial or full edentulous state has become the standard treatment in recent years. Bone graft with guided bone regeneration technique has been regarded as one of the most reliable methods to restore the bone defect area due to periodontal disease or dental trauma. Bone graft materials and membrane are the essential component of guided bone regeneration; however, a variety of bone graft materials confuse us in implant dentistry. Autogenous bone is the recognized standards in implant dentistry owing to its osteogenesis potential. Despite of its disadvantages, grafting autogenous bone is the most reliable methods. Even though the development of new bone grafts materials, autogenous bone is useful in exposed implant thread and total lack of buccal or lingual bone. Allogenic, xenogenic and synthetic bone have the osteoconductive and osteoinductive potential. These materials could be used successfully in self-contained cavity such as sinus cavity and three-wall defects. In this article, application of bone graft material is suggested according to the function of bone graft materials.