• Title/Summary/Keyword: Full bridge convert

Search Result 9, Processing Time 0.026 seconds

The Driving Circuit Design for ZVS Full-Bridge Converter with 1st Order Delay Circuit (1차 지연회로를 사용한 ZVS Full-Bridge 컨버터 구동회로 설계)

  • Cho, Nae-Soo;Choi, Youn-Ho;Yoon, Kyung-Sup;Koo, Bon-Ho;Kwon, Woo-Hyen
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.3
    • /
    • pp.569-574
    • /
    • 2010
  • The full bridge converter have been used for high power system that is needed to switch the big current. So, EMI and stability problem is occurred. The Soft switching method is the solution to solve the above problem, But implementation of soft switching(ZVS: Zero Voltage Switching) is so complicate and expensive because of the DSP MCU and shift circuit. In this paper, we introduce the technical method for driving circuit of ZVS full bridge converter with 1st order delay circuit and logic elements. The realization of this method is so simple and cheap. The effectiveness of the proposed circuit is verified by experimental results.

A Study on Reducing Conduction Losses for High Speed Welding of Thin Plates (박판 고속 용접전원의 도전손실 저감에 관한 연구)

  • Bae, Jong-Moon;Kim, Joon-Hong
    • Proceedings of the KIEE Conference
    • /
    • 2002.06a
    • /
    • pp.166-171
    • /
    • 2002
  • We are in transitional period of welding technique, which has changed from the stage of quantity and quality to the stage of future technique, imported and introduced from many advanced countries. Therefore, many researches and studies for development on high speeding and making welding machines with high effectiveness has been doing vigorously. In this dissertation, I have studied on a pulsed MAG welding machine, with which welding of thin plates may perform high speeding and effecting. First, I produced a phase shifted full bridge DC-DC convert, which is the type of reduced conduction loss and the power supply for welding machine. And then, I found out an output waveform control algorithm about one pulsed one droplet and short waveform control for thin plates with high speed by deriving the circuit model utilizing the circuit averaged method for full bridge converter.

  • PDF

A Design of Power Converter for Fuel Cell Controlled by Micro-Processor (마이크로프로세서에 의해 제어되는 연료전지용 전력변환 회로 설계)

  • Won, Chung-Yuen;Jang, Su-Jin;Lee, Won-Chul;Lee, Tae-Won;Kim, Soo-Seok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.5
    • /
    • pp.61-68
    • /
    • 2004
  • Recently, a fuel cell is remarkable for new generation system. The fuel cell is characterized by low voltage and high current. Therefor, for connecting to general load, it needs both a step up converter and an inverter. The proposed system consists of an isolated DC-DC converter to boost the fuel cell voltage to 380[Vdc] and a PWM inverter with LC filter to convert the dc voltage to single phase 220[Vac]. Also, bi-directional DC-DC converter for fuel cell generation system is composed to improve load response characteristic. In this paper, full bridge converter and the single phase inverter are designed and installed for fuel cell. Simulation and experiment verify that fuel cell generation system could be applied for the distributed generation.

Characteristic of fuel Cell DC-AC Inverter Using New Active Clamping Method (새로운 능동 클램핑방식을 이용한 연료전지용 DC-AC 인버터의 특성)

  • Kim, C.Y.;Cho, M.C.;Mun, S.P.;Kim, Y.J.;Nakaoka, Mutsuo;Kim, H.S.
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.337-340
    • /
    • 2007
  • In the dissertation, a power conversion system for fuel cell is composed of a PWM inverter with LC filter in order to convert fuel cell voltage to a single phase 220[V], In addition, new insulated DC-DC converters are proposed in order that fuel cell voltage is boosted to 380[V]. In this paper, it requires smaller components than existing converters, which makes easy control. The proposed DC-DC converter controls output power by the adjustment of phase-shift width using switch S5 and S6 in the secondary switch, which provides 93-97[%] efficiency in the wide range of output voltage. Fuel cell simulator is implemented to show similar output characteristics to actual fuel cell. Appropriate dead time td enables soft switching to the range where the peak value of excitation current in a high frequency transformer is in accordance with current in the primary circuit. Moreover, appropriate setting to serial inductance La reduces communication loss arisen at light-load generator and serge voltage arisen at a secondary switch and serial diode. Finally, TMS320C31 board and EPLD using PWM switching technique to act a single phase full-bridge inverter which is planed to make alternating current suitable for household.

  • PDF

Developement of Electrical Load Testing System Implemented with Power Regenerative Function (회생전력 기능을 갖는 전기부하시험장치 개발)

  • Do, Wang-Lok;Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.2
    • /
    • pp.179-184
    • /
    • 2016
  • The electrical load testing system developed from this study was designed to control rated-capacity-testing or variable-load-testing in an active and precise manner and save electric energy during testing, and also to convert the saved electric energy through the electrical load testing system to grid line. As for the device under testing, it was designed to be applied to not only transformer, rectifier, voltage regulator, inverter which require grid voltage source but, also applied to electric power, aerogenerator, photovoltaic, hybrid generator, battery, etc. which do not require grid voltage source. The system was designed to return the power consumed during the testing to the grid line by connecting the synchronizing pwm inverter circuit to the grid voltage source, and was also made to enable the being-tested system from disuse of approximately 93.4% energy when compared to the conventional load testing system which has used the passive resistor.

Weigh-in-Motion load effects and statistical approaches for development of live load factors

  • Yanik, Arcan;Higgins, Christopher
    • Structural Engineering and Mechanics
    • /
    • v.76 no.1
    • /
    • pp.1-15
    • /
    • 2020
  • The aim of this paper is to simply present live load factor calculation methodology formulation with the addition of a simple new future load projection procedure to previously proposed two methods. For this purpose, Oregon Weigh-in-Motion (WIM) data were used to calculate live load factors by using WIM data. These factors were calculated with two different approaches and by presenting new simple modifications in these methods. A very simple future load projection method is presented in this paper. Using four different WIM sites with different average daily truck traffic (ADTT) volume, and all year data, live load factors were obtained. The live load factors, were proposed as a function of ADTT. ADTT values of these sites correspond to three different levels which are approximately ADTT= 5,000, ADTT = 1,500 and ADTT ≤ 500 cases. WIM data for a full year were used from each site in the calibration procedure. Load effects were projected into the future for the different span lengths considering five-year evaluation period and seventy-five-years design life. The live load factor for ADTT=5,000, AASHTO HS20 loading case and five-year evaluation period was obtained as 1.8. In the second approach, the methodology established in the Manual for Bridge Evaluation (MBE) was used to calibrate the live load factors. It was obtained that the calculated live load factors were smaller than those in the MBE specifications, and smaller than those used in the initial calibration which did not convert to the gross vehicle weight (GVW) into truck type 3S2 defined by AASHTO equivalents.

CNN based data anomaly detection using multi-channel imagery for structural health monitoring

  • Shajihan, Shaik Althaf V.;Wang, Shuo;Zhai, Guanghao;Spencer, Billie F. Jr.
    • Smart Structures and Systems
    • /
    • v.29 no.1
    • /
    • pp.181-193
    • /
    • 2022
  • Data-driven structural health monitoring (SHM) of civil infrastructure can be used to continuously assess the state of a structure, allowing preemptive safety measures to be carried out. Long-term monitoring of large-scale civil infrastructure often involves data-collection using a network of numerous sensors of various types. Malfunctioning sensors in the network are common, which can disrupt the condition assessment and even lead to false-negative indications of damage. The overwhelming size of the data collected renders manual approaches to ensure data quality intractable. The task of detecting and classifying an anomaly in the raw data is non-trivial. We propose an approach to automate this task, improving upon the previously developed technique of image-based pre-processing on one-dimensional (1D) data by enriching the features of the neural network input data with multiple channels. In particular, feature engineering is employed to convert the measured time histories into a 3-channel image comprised of (i) the time history, (ii) the spectrogram, and (iii) the probability density function representation of the signal. To demonstrate this approach, a CNN model is designed and trained on a dataset consisting of acceleration records of sensors installed on a long-span bridge, with the goal of fault detection and classification. The effect of imbalance in anomaly patterns observed is studied to better account for unseen test cases. The proposed framework achieves high overall accuracy and recall even when tested on an unseen dataset that is much larger than the samples used for training, offering a viable solution for implementation on full-scale structures where limited labeled-training data is available.

A Study on Power Conversion System for Fuel Cell Controlled by Micro-Processor (마이크로프로세서에 의해 제어되는 연료전지용 전력변환장치에 관한 연구)

  • Kim, Ju-Yong;Jung, Sang-Hwa;Mun, Sang-Pil;Ryu, Jae-Yup;Suh, Ki-Young
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.5
    • /
    • pp.10-24
    • /
    • 2007
  • In the dissertation, a power conversion system for fuel cell is composed of a PWM inverter with LC filter in order to convert fuel cell voltage to a single phase 220[V]. In addition, new insulated DC-DC converters are proposed in order that fuel cell voltage is boosted to 380[V]. In this paper, it requires smaller components than existing converters, which makes easy control. The proposed DC-DC converter controls output power by the adjustment of phase-shift width using switch $S_5\;and\;S_6$ in the secondary switch which provides 93-97[%] efficiency in the wide range of output voltage. Fuel cell simulator is implemented to show similar output characteristics to actual fuel cell. Appropriate dead time td enables soft switching to the range where the peak value of excitation current in a high frequency transformer is in accordance with current in the primary circuit. Moreover, appropriate setting to serial inductance La reduces communication loss arisen at light-load generator and serge voltage arisen at a secondary switch and serial diode. Finally, TMS320C31 board and EPLD using PWM switching technique to act a single phase full-bridge inverter which is planed to make alternating current suitable for household

A Study on the Main Issue and Its Solution Explored through Mediation Cases - Focused on the Cases of Busan National Labor Relations Commission - (조정사건을 통해 살펴본 주요 쟁점사항과 해결방안에 대한 연구 - 부산지방노동위원회의 사례를 중심으로 -)

  • Song, Kyung-Soo;Kim, Yong-Ho
    • Management & Information Systems Review
    • /
    • v.30 no.4
    • /
    • pp.253-292
    • /
    • 2011
  • This study is significant of groping for the autonomous perspective of a medication system for the establishment of harmonious regional labor-management relationship and investigating a plan to minimize previously labor disputes through both analyzing mediation cases and finding out any core issue from the labor-management relationship, with matters experienced in the mediation field when I had served as a mediator. Specially, this study has also objectives to prevent previously any labor dispute through analyzing and minimizing the issue of the labor dispute by case and to establish harmonious labor-management relationship thereby. Further since it is necessary to understand the organization and roles of the regional labor relations commission in order to understand the concrete matters in respect of the labor dispute mediation, this study shall be to explore in detail the matters relating hereto and to acquire general knowledge of mediation through case analysis. Additionally, there is little studies exploring alternative research for the establishment of reasonable labor-management relationship with core issues referred a mediation to the labor relations commission through both the position heightening of the labor relations commission and the analysis of core issues until now. Thus, this study may provide a theoretical base for raising a technique to enhance negotiation skill through acquiring the previous training or full knowledge on the approaching manner to be taken by the labor and management in the collective bargaining or wage bargaining on the basis of items analyzed by core issue. The heightening perspectives to be acquired through the analysis of 50 or more mediation cases are as follows. First, it deems to be important what position each mediation party takes. Second, the information acquired by an investigator in the preliminary investigation before holding the mediation is very importantly utilized in the mediation. Third, the gumption of mediators in charge of the mediation is very helpful for the resolution of a case. Fourth, it shall be preceding to understand dispute issues. After reviewing fully the investigation report of an investigator, if separate review is required, it is tried to hold a separate meeting and then reduce the number of issues asserted by the labor & management and, if the number of such issues is reduced, the mediation may approach to be concluded. Fifth, it shall be kept in mind that any matter other than the scope of the law be based on not the judgement of mediator but the legal interpretation. Sixth, it is necessary for both labor and management parties to take a positive approach so as to make the healthy labor & management relationship anchored. Seventh, notwithstanding the mediators are part-time and take a service attitude, it shall be encouraged to abstain from slandering or inveighing against the mediators because the mediation is taken against oneself. Eighth, it is necessary to convert the management's recognition about a labor union. Ninth, it is necessary to not raise any issue on the matters, such as time-off system and multiple labor union, etc., which are legally enforced. Tenth, it is confirmed that the regional labor relations commission plays a bridge role of narrowing down the issue difference between the labor and management.

  • PDF