• Title/Summary/Keyword: Full Rate

Search Result 1,774, Processing Time 0.026 seconds

Enhanced TFRC for High Quality Video Streaming over High Bandwidth Delay Product Networks

  • Lee, Sunghee;Roh, Hyunsuk;Lee, Hyunwoo;Chung, Kwangsue
    • Journal of Communications and Networks
    • /
    • v.16 no.3
    • /
    • pp.344-354
    • /
    • 2014
  • Transmission control protocol friendly rate control (TFRC) is designed to mainly provide optimal service for unicast applications, such as multimedia streaming in the best-effort Internet environment. However, high bandwidth networks with large delays present an environment where TFRC may have a problem in utilizing the full bandwidth. TFRC inherits the slow-start mechanism of TCP Reno, but this is a time-consuming process that may require many round-trip-times (RTTs), until an appropriate sending rate is reached. Another disadvantage inherited from TCP Reno is the RTT-unfairness problem, which severely affects the performance of long-RTT flows. In this paper, we suggest enhanced TFRC for high quality video streaming over high bandwidth delay product networks. First, we propose a fast startup scheme that increases the data rate more aggressively than the slow-start, while mitigating the overshooting problem. Second, we propose a bandwidth estimation method to achieve more equitable bandwidth allocations among streaming flows that compete for the same narrow link with different RTTs. Finally, we improve the responsiveness of TFRC in the presence of severe congestion. Simulation results have shown that our proposal can achieve a fast startup and provide fairness with competing flows compared to the original TFRC.

Fate of abstracts presented at the Turkish Association of Oral and Maxillofacial Surgeons (TAOMS) meetings between 2007 and 2009

  • Yolcu, Umit;Kucuk, Ayse Ozcan
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.44 no.5
    • /
    • pp.237-241
    • /
    • 2018
  • Objectives: The aim of this study was to determine the rate of peer-reviewed publication of abstracts presented at the annual meetings of the Turkish Association of Oral and Maxillofacial Surgeons (TAOMS) and to identify the time to publication, subspecialty, and study design. Materials and Methods: All abstracts accepted for presentation at a TAOMS meeting between 2007 and 2009 were identified from a book of abstracts and were searched for publication using PubMed and Google Scholar. The following variables were evaluated: publication rate, type of presentation (oral or poster), time to publication, subspecialty, study design, and name of the journal in which the article was published. Results: A total of 478 abstracts were presented at the TAOMS meetings between 2007 and 2009. Of these, 140 abstracts (29.3%) were subsequently published in peer-reviewed journals, including 38.2% of oral presentations and 26.6% of poster presentations. The mean time from presentation to publication was 22 months. Regarding publication fields, research and emerging technologies presentations had the highest publication rate (100%). With regard to study type, animal study (70.0%) and basic research (55.0%) had the highest publication rates. Conclusion: Only 29.3% of abstracts presented at the TAOMS meeting were subsequently published as full-text articles. This rate was found to be similar to the previously reported publication rates in the field of oral and maxillofacial surgery.

Fatigue crack growth properties of ceramic coated 1Cr-1Mo-0.25V steel (세라믹 코팅된 1Cr-1Mo-0.25V강의 피로균열성장 특성)

  • Seo, Chang-Min;Kim, Gyeong-Ryeol
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.21 no.10
    • /
    • pp.1674-1682
    • /
    • 1997
  • Fatigue tests were performed to investigate the effect of ceramic coatings as in TiN and TiCN on fatigue crack growth properties of ceramic coated 1Cr-1Mo-0.25V steel with different coating thickness in laboratory air conditions. The experimental results are described with respect to a Paris equation, da/dN=C(.DELTA.K)$^{m}$ , where the crack growth rate of coated specimens provided as similar growth rate as that of the uncoated specimen regardless of coating thickness. Furthermore, it was observed that the type of coating layer had virtually no effect on crack growth rate in the full region of stress intensity factor range. And it was also appeared that the final crack length of TiCN coated specimens was short compared to that of TiN coated, and the substrate specimens, in which it was inferred due to lowering the toughness of coated material from high hardness of TiCN coating layer itself.

Modeling of silicon carbide etching in a $NF_3/CH_4$ plasma using neural network ($NF_3/CH_4$ 플라즈마를 이용한 실리콘 카바이드 식각공정의 신경망 모델링)

  • Kim, Byung-Whan;Lee, Suk-Yong;Lee, Byung-Teak;Kwon, Kwang-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.58-62
    • /
    • 2003
  • Silicon carbide (SiC) was etched in a $NF_3/CH_4$ inductively coupled plasma. The etch process was modeled by using a neural network called generalized regression neural network (GRNN). For modeling, the process was characterized by a $2^4$ full factorial experiment with one center point. To test model appropriateness, additional test data of 16 experiments were conducted. Particularly, the GRNN predictive capability was drastically improved by a genetic algorithm (GA). This was demonstrated by an improvement of more than 80% compared to a conventionally obtained model. Predicted model behaviors were highly consistent with actual measurements. From the optimized model, several plots were generated to examine etch rate variation under various plasma conditions. Unlike the typical behavior, the etch rate variation was quite different depending on the bias power Under lower bias powers, the source power effect was strongly dependent on induced dc bias. The etch rate was strongly correated to the do bias induced by the gas ratio. Particularly, the etch rate variation with the bias power at different gas ratio seemed to be limited by the etchant supply.

  • PDF

Microstructural Features of Al Alloy 7N01 Welded by $CO_2$ Laser - Microsturctural Features of Full Penetration Joints - ($CO_2$ 레이저 용접한 7N01 Al합금의 미세조직 특징(I) - 완전용입 용접부의 미세조직 -)

  • 윤재정;강정윤;김인배;김대업
    • Journal of Welding and Joining
    • /
    • v.19 no.4
    • /
    • pp.429-436
    • /
    • 2001
  • The effect of welding condition on the microstructures of the weld metal in A7N01 welded by $CO_2$ laser was investigated. The number of ripples was increased with decreasing power and increasing welding speed. In the bead without ripple lines, the subgrain microstructures distribution from the fusion line toward the center of the bead were in the order of cellular, dendritic and equiaxed dendrite. However, in the bead with ripple lines, cellular and dendritic were formed between the fusion boundary and the ripple line. Inaddition, those structures were also observed between the ripple line. Equiaxed dendrites were formed only at the center line region. Cellular and dendritics formed near the ripple line were larger than those formed near the fusion boundary. The cooling rates estimated by the dendrite arm spacing were in the range of 200 to 1150oC/s. Cooling rate was increased with decreasing the power and increasing the welding speed. Mg and Zn segregated at the boundaries of cellulars and dendritics, Mg was segregated more than Zn. The segregation of Mg and Zn decreased with increasing cooling rate. Hardness of the weld metal was lower than that of the base metal in all welding conditions and increased as the cooling rate increased.

  • PDF

Effects of Cyclic Loading Rate on response of Reinforced Concrete Structures (철근콘크리트 구조물에 대한 반복하중속도의 영향에 관한 연구)

  • Chung, Lan;Park, Hyun-Soo
    • Computational Structural Engineering
    • /
    • v.2 no.3
    • /
    • pp.77-84
    • /
    • 1989
  • Small-scale models of reinforced concrete beam-column joints and anchorage-bond specimens were subjected to large cyclic displacements at two rates. To assess damage, free vibration tests were conducted. The reliability of the modeling techniques was established by comparison of the results for the slower rate with those obtained from the full-scale tests on prototype. The higher rate of loading caused a greater damage than that at the slower rate. This was evidenced by the measurements of the stiffness obtained from the free-vibration test. The relatively greater extent of damage appears to result from the different bond behavior at different rates of loading.

  • PDF

Development of an Ejector System for Operating of Chemical Lasers (III) - Development and Performance Validation of a Full-Scale Ejector System for High Power Chemical Lasers - (화학레이저 구동용 이젝터 시스템 개발 (III) - 고출력 화학레이저용 실물 크기의 이젝터 시스템 개발 및 성능 검증 -)

  • Kim, Se-Hoon;Jin, Jung-kun;Kwon, Se-Jin
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.29 no.1 s.232
    • /
    • pp.9-15
    • /
    • 2005
  • From the geometric parameter study, an optimal ejector design procedure of pressure recovery system for chemical lasers was acquired. For given primary flow reservoir conditions, an up-scaled ejector was designed and manufactured. In the performance test, secondary mass flow rate of 100g/s air was entrained satisfying the design secondary pressure, $40{\sim}50torr$. Performance validation of a supersonic ejector system along with an investigation of effects of supersonic diffuser was conducted. Placement of the diffuser at the secondary inlet further reduced diffuser upstream pressure to 7torr. Lastly, the duplicate of apparatus (air 500g/s secondary mass flow rate each) was built and connected in parallel to assess proportionality behavior on a system to handle larger mass flow rate. Test and comparison of the parallel unit demonstrated the secondary mass flow rate was proportional to the number of individual units that were brought together maintaining the lasing pressure.

The Comparison of the Relationship between the Gunfire Shot and Its Resulting Heavy Metal Pollution Rate (소화기 사격장의 사격에 따른 중금속 오염도 비교(I))

  • Hong, Sung Tae;Hyun, Jae Hyuk
    • Journal of Soil and Groundwater Environment
    • /
    • v.19 no.6
    • /
    • pp.1-5
    • /
    • 2014
  • The following research was initiated in order to compare the relationship between the amount of gunfire shot and its resulting heavy metal pollution rate. The research was conducted at two firing ranges located inside a military unit stationed in the rear strategical area, where one full distance firing range is used by soldiers in active service, and the other is used by recruits and reserves. The heavy metal pollution rate was measured also on water sample collected from the target zone while raining. Based on values such as the real amount of gunshot fired, amount of heavy metal in the soil of the target zone, and the degree of heavy metal pollution for each firing range, the research showed that although pollution rate was higher when more gunshots were fired, there was no close correlation between the two. The water samples showed that this might result from the soils containing heavy metals eroded and transported by rain due to the target zone having no vegetation.

An Empirical Study on the Operation of Cogeneration Generators for Heat Trading in Industrial Complexes

  • Kim, Jaehyun;Kim, Taehyoung;Park, Youngsu;Ham, Kyung Sun
    • Journal of the Korea Society of Computer and Information
    • /
    • v.24 no.3
    • /
    • pp.29-39
    • /
    • 2019
  • In this study, we introduce a model that satisfies energy efficiency and economical efficiency by introducing and demonstrating cogeneration generators in industrial complexes using various actual data collected at the site. The proposed model is composed of three scenarios, ie, full - time operation, scenario operated according to demand, and a fusion type. In this study, the power generation profit and surplus thermal energy are measured according to the operation of the generator, and the thermal energy is traded according to the demand of the customer to calculate the profit and loss including the heat and evaluate the economic efficiency. As a result of the study, it is relatively profitable to reduce the generation of the generator under the condition that the electricity rate is low and the gas rate is high, while the basic charge is not increased. On the contrary, if the electricity rate is high and the gas rate is low, The more you start up, the more profit you can see. These results show that even a cogeneration power plant with a low economic efficiency due to a low "spark spread" has sufficient economic value if it can sell more than a certain amount of heat energy from a nearby customer and adjust the applied power through peak management.

Effect of cooling rate on the post-fire behavior of CFST column

  • Afaghi-Darabi, Alireza;Abdollahzadeh, Gholamreza
    • Computers and Concrete
    • /
    • v.23 no.4
    • /
    • pp.281-294
    • /
    • 2019
  • The post-fire behavior of structural elements and the cooling process has always been one of the main concerns of the structural engineers. The structures can be cooled at different rates, where they affect the structure's behavior. In the present study, a numerical model has been developed using the Abaqus program to investigate the effect of cooling rate on the post-fire behavior of the CFST column. To verify the model, results of an experimental study performed on CFST columns within a full heating and cooling cycle have been used. In this model, coMParison of the residual strength has been employed in order to examine the behavior of CFST column under different cooling rates. Furthermore, a parametric study was carried out on the strength of steel and concrete, the height of the specimens, the axial load ratio and the cross-sectional shape of the specimen through the proposed model. It was observed that the cooling rate affects the behavior of the column after the fire, and thus the higher the specimen's temperature is, the more effect it has on the behavior. It was also noticed that water cooling had slightly more residual strength than natural cooling. Furthermore, it was recognized from the parametric study, that by increasing the strength of steel and concrete and the load ratio, as well as modifying the cross-sectional shape from circular to square, residual strength of column at the cooling phase was less than that of the heating phase. In addition, with reducing column height, no change was witnessed in the column behavior after the cooling phase.