• Title/Summary/Keyword: Full Rate

Search Result 1,774, Processing Time 0.025 seconds

Characteristics of Growth and Photosynthesis of Peucedanum japonicum by Shading and Leaf Mold Treatment in Forest Farming (임간재배 시 차광과 부엽토 처리에 따른 갯기름나물의 생장 및 광합성 특성)

  • Song, Ki Seon;Jeon, Kwon Seok;Choi, Kyu Seong;Kim, Chang Hwan;Park, Yong Bae;Kim, Jong Jin
    • Journal of Korean Society of Forest Science
    • /
    • v.105 no.1
    • /
    • pp.78-85
    • /
    • 2016
  • This study was carried out to determine the effects of shading and leaf mold treatment on growth characteristics and photosynthesis responses of Peucedanum japonicum in forest farming. It is very valuable as a sort of health food, so that the demand for the vegetable has increased recently. The experiment can not only increase the yield but also contribute to the development of eco-friendly technology for high-quality P. japonicum. It was performed by shading treatments (full sunlight, 35%, 50% and 75% shading) and leaf mold treatments (control, pine tree and chestnut tree). Height, stem diameter, root collar diameter, number of stem and dry weight were the highest in chestnut-leaf mold under full sunlight. Leaf area, leaf length and leaf width were the highest in chestnut-leaf mold under 35% shading. Photosynthetic rate, conductance to $H_2O$, transpiration rate and water use efficiency were the highest in chestnut-leaf mold under full sunlight. Specially, photosynthetic rate was higher under chestnut-leaf mold in all shading treatment, and getting lower in the higher shading rate. As a result of surveying the whole experiment, it is concluded that P. japonicum grows nicely by maintaining 35% shading under chestnutleaf mold in forest farming. Thus, it is the most effective way to increase the yield for high-quality P. japonicum with eco-friendly technology.

The Effect of Greenhouse Climate Change by Temporary Shading at Summer on Photo Respiration, Leaf Temperature and Growth of Cucumber (여름철 수시차광에 의한 온실 환경변화가 오이의 광호흡, 엽온, Thermal breakdown 등 생육에 미치는 영향)

  • Kim, Dong Eok;Kwon, Jin Kyung;Hong, Soon Jung;Lee, Jong Won;Woo, Young Hoe
    • Journal of Bio-Environment Control
    • /
    • v.29 no.3
    • /
    • pp.306-312
    • /
    • 2020
  • This study was conducted to investigate cucumber plants response to greenhouse environments by solar shading in greenhouse in the summer. In order to estimate heat stress reduction of cucumber plants by solar shading in greenhouse, we measured and analyzed physiological conditions of cucumber plants, such as leaf temperature, leaf-air temperature, rubisco maximum carboxylation rate, maximum electron transport rate, thermal breakdown, light leaf respiration, etc. Shading levels were 90% mobile shading of full sunlight, 40% mobile shading of full sunlight and no shading(full sunlight). The 90% shading screen was operated when the external solar radiation is greater than 650 W·m-2. Air temperature, solar radiation, leaf temperature, leaf-air temperature and light leaf respiration in the 90% shading of full sunlight was lower than those of 40% shading and no shading. Rubisco maximum carboxylation rate, arrhenius function value and light leaf respiration of the 90% shading were significantly lower than those of 40% shading and no shading. The thermal breakdown, high temperature inhibition, of 90% shading was significantly higher than that of 40% shading and no shading. Therefore, these results suggest that 90% mobile shading made a less stressful growth environment for cucumber crops.

Clinical evaluation of full mouth disinfection therapy (Full mouth disinfection therapy의 단기간 임상 효과 연구)

  • Cho, Ik-Hyun;Jung, Ui-Won;Cha, Jeong-Heon;Kim, Joong-Su;Lee, Dae-Sil;Kim, Chang-Seong;Kim, Chong-Kwan;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.35 no.3
    • /
    • pp.597-608
    • /
    • 2005
  • The aim of this study is to determine whether full-mouth disinfection therapy(FMT) in our clinical setting would show better improvement of clinical parameters than partial mouth disinfection therapy(PMT) in chronic periodontitis and aggressive periodontitis patients. Among 12 patients, 6 were treated FMT and other 6 were treated PMT. Clinical parameters were calculated 3 months and 6 months after initial therapy. 1. There were no statistically significant differences between FMT and PMT in the reduction rate of bleeding on probing after 3 months, 6 months 2. Initial probing depth was 4-6mm, the mean probing depth after 3 months was 2.2mm vs 2.5mm(FMT vs PMT), after 6 months was 2.4mm vs 2.8mm. This was significantly lower in the FMT groups. 3. Initial probing depth was ${\geqq}$ 7mm, the reduction rate of mean probing depth during first 3 months was 4.8mm vs 4.1mm(FMT vs PMT), and 3 to 6 months was 0.5mm vs 0.3mm. This was significantly larger in the FMT groups. 4. Initial probing depth was 4-6mm, the mean clinical attachment level after 3 months was 2.3mm vs 2.7mm(FMT vs PMT), after 6 months was 2.7mm vs 3.0mm. This was significantly lower in the FMT groups. 5. Initial probing depth was ${\geqq}$ 7mm, the reduction rate of mean probing depth during first 3 months was 4.0mm vs 3.0mm(FMT vs PMT), and 3 to 6 months was 0mm vs -0.1mm. This was significantly larger in the FMT groups. Although the results provided us with succeccful clinical improvement in aggressive periodontitis, further research is needed to prove its additional benefit in the treatment of chronic periodontitis

Experimental Study on the Measurement of Fire Behavior and Heat Release Rate in Building Compartment Space - Focus on Full Scale Fire Test of the Bed Mattress - (건축물 구획공간에 따른 화재성상 및 열방출율 측정에 관한 실험적 연구 - 실물규모 침대 매트리스 화재시험 중심으로 -)

  • Seo, Bo-Youl;Jang, Woo-Bin;Park, Kye-Won;Hong, Won-Hwa
    • Fire Science and Engineering
    • /
    • v.32 no.6
    • /
    • pp.28-33
    • /
    • 2018
  • To measure the full scale fire test and heat release rate of bed mattresses according to the building compartment space, a fire test was performed using the Standard test method to determine the heat release rate of mattresses and mattress sets (KS F ISO 12949: 2011). Both test locations showed similar fire growth until approximately 3 minutes after burner ignition. After 3 minutes, the heat release rate in the test room was higher than the open calorimeter. For bed mattresses (SS), the maximum heat release rate in the open calorimeter was 735 kW and the maximum heat release rate in the test room was 992 kW. For bed mattresses (Q), the heat release rate in the test room increased more rapidly than the open calorimeter. The maximum heat release rate in the open calorimeter was 1,087 kW (346 s) and the maximum heat release rate in the test room was 2,127 kW (287 s). The difference between the maximum heat release rate and the measurement time according to the test location was confirmed.

A Minimum Data-Rate Guaranteed Resource Allocation With Low Signaling Overhead in Multi-Cell OFDMA Systems

  • Kwon, Ho-Joong;Lee, Won-Ick;Lee, Byeong-Gi
    • Journal of Communications and Networks
    • /
    • v.11 no.1
    • /
    • pp.26-35
    • /
    • 2009
  • In this paper, we investigate how to do resource allocation to guarantee a minimum user data rate at low signaling overhead in multi-cell orthogonal frequency division multiple access (OFDMA) wireless systems. We devise dynamic resource allocation (DRA) algorithms that can minimize the QoS violation ratio (i.e., the ratio of the number of users who fail to get the requested data rate to the total number of users in the overall network). We assume an OFDMA system that allows dynamic control of frequency reuse factor (FRF) of each sub-carrier. The proposed DRA algorithms determine the FRFs of the sub-carriers and allocate them to the users adaptively based on inter-cell interference and load distribution. In order to reduce the signaling overhead, we adopt a hierarchical resource allocation architecture which divides the resource allocation decision into the inter-cell coordinator (ICC) and the base station (BS) levels. We limit the information available at the ICC only to the load of each cell, that is, the total number of sub-carriers required for supporting the data rate requirement of all the users. We then present the DRA with limited coordination (DRA-LC) algorithm where the ICC performs load-adaptive inter-cell resource allocation with the limited information while the BS performs intra-cell resource allocation with full information about its own cell. For performance comparison, we design a centralized algorithm called DRA with full coordination (DRA-FC). Simulation results reveal that the DRA-LC algorithm can perform close to the DRA-FC algorithm at very low signaling overhead. In addition, it turns out to improve the QoS performance of the cell-boundary users, and achieve a better fairness among neighboring cells under non-uniform load distribution.

Data Mining Analysis of Educational and Research Achievements of Korean Universities Using Public Open Data Services (정보공시 자료를 이용한 교육/연구성과 영향요인 추출 및 대학의 군집 분석)

  • Shin, Sun Mi;Kim, Hyeon Cheol
    • The Journal of Korean Association of Computer Education
    • /
    • v.17 no.1
    • /
    • pp.117-130
    • /
    • 2014
  • The purpose of this study is to provide useful knowledge for improving indicators that represent competitiveness and educational competency of the university by deriving a new pattern or the meaningful results from the data of information disclosure of universities using statistical analysis and data mining techniques. To achieve this, a model of decision tree was made and various factors that affect education/research performance such as employment rate, the number of technology transfer and papers per full-time faculty were explored. In addition to this, the cluster analysis of universities was conducted using attributes related to evaluation of university. According to the analysis, common factors affecting higher education/research performance are following indicators ; incoming student recruitment rate, enrollment rate, and the number of students per full-time faculty. In the cluster analysis, when performed by the entire university, the size, location of the university respectively, clusters are mainly formed by well-known universities, art physical non-science and engineering religious leaders training universities, and others. The main influencing factors of this cluster are higher education/research performance indicators such as employment rate and the number of technology transfer.

  • PDF

Effect of Curing Conditions on the ASR of Lightweight Aggregate Concrete (양생조건이 경량골재 콘크리트의 ASR에 미치는 영향)

  • 성찬용;김성완;민정기
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.35 no.4
    • /
    • pp.38-46
    • /
    • 1993
  • This study is to analyze effect of exposure environment and mode of ASR on the engineering properties of synthetic lightweight aggregate concrete, such as dynamic modulus of elasticity and ultrasonic pulse velocity. The results of this study are summarized as foflows ; 1. The expansion rate of each exposure environment in 380$^{\circ}$C and NaCI 4% solution was shown higher than in 20$^{\circ}$C and normal water. The expansion rate of each exposure mode was largely shown in order of fjill immersion, wetting/drying, half immersion. 2. The dynamic modulus of elasticty and ultrasonic pulse velocity of each exposure environment in 38$^{\circ}$C and NaCl 4% solution was shown less than in 20$^{\circ}$C and normal water. The dynamic modulus of elasticity and ultrasonic pulse velocity of each exposure mode was shown smaller in order of full immersion, wetting/drying, half imersion.3. The relation between dynamic modulus of elasticity and ultrasonic pulse velocity was highly significant. The dynamic modulus of elasticity was increased with increase of ultrasonic pulse velocity. The decreasing rate of the dynamic modulus of elasticity was shown 2.1~3.4 times higher than the ultrasonic pulse velocity at each age, exposure environment and mode, respectively. 4. The expansion of each exposure environment and mode was increased with increase of curing age. The dynamic modulus of elasticity and ultrasonic pulse velocity of those concrete was increased with increase of curing age. At the curing age 28 days, the highest properties was showed at each type concrete, it was gradually decreased with increase of curing age. Specially, at the curing age 98 days of full immersion, the rate of expansion of type D was shown 3.95 times higher than the type A. But the dynamic modulus of elasticity and ultrasonic pulse velocity was decreased 17% and 8.3%.

  • PDF