• Title/Summary/Keyword: Fuel-saving

Search Result 281, Processing Time 0.023 seconds

A Basic Study for the Application of the Shafting System for the Contra-Rotating Propeller (상반회전 프로펠러 축계 실용화를 위한 기초 연구)

  • Shin, Sang-Hoon;Lee, Seung-Min;Rim, Chae Whan
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.7
    • /
    • pp.391-398
    • /
    • 2020
  • If the lost energy produced by a propeller can be partially recovered, the propulsive efficiency can be increased, and the fuel consumption reduced. The devices installed for this purpose are called Energy Saving Devices, of which the Contra-Rotating Propeller system is one of the most effective devices. The first problem to be solved to install the Contra-Rotating Propeller system on a large ship is that the mean pressure generated in the journal bearing needs to meet the design criteria of the classifications. In Korea, however, the practical use is being delayed because it cannot overcome this step. The next step is to lower local pressure to increase the reliability. In this study, to solve the mean pressure problem as the first step of practical use, a product carrier with a short stern shape was selected to reduce the weight of the shafting system, and a suitable shafting-system design plan was proposed. Shaft analysis confirmed that the mean pressure of 0.8 MPa (8 bar), which is a design criterion of the classifications for a journal bearing lining material (white metal), was satisfied. In addition, the necessity of reducing the local pressure was also confirmed.

An Algorithm for Heavy Duty Truck Priority on Left-turn to Reduce Greenhouse Gas Emissions (온실가스 감축을 위한 대형 화물차 좌회전 우선신호 알고리즘 개발)

  • Yang, Se Jung;Kim, Suhyeon;Kim, Hyo Seung;Lee, Chungwon
    • Journal of Korean Society of Transportation
    • /
    • v.31 no.5
    • /
    • pp.60-70
    • /
    • 2013
  • This study aims to develop a truck priority on left-turn algorithm that can reduce greenhouse gas emissions by reducing heavy duty truck's stops at signalized intersection. The signal priority is granted for a left-turn phase, because heavy duty trucks can deteriorate left-turn traffic flow due to the low acceleration or deceleration rate and large turn radius. Truck priority allows to provide the stable speed control for heavy duty truck, and reduces emissions at the signal intersection. Also, two signal recovery strategies are compared for various traffic conditions. This study analyzes the effectiveness of truck priority such as greenhouse gas emissions and fuel consumption reduction, and total travel time saving using the PARAMICS and Comprehensive Modal Emissions Model (CMEM). The results show that signal priority for heavy duty trucks has an effect on reducing greenhouse gas emissions and fuel consumptions at non-peak hour. Also, it shows decreasing total travel time due to reducing truck stops.

THERMAL-FLUID ANALYSIS FOR COOLING PERFORMANCE IMPROVEMENT OF 3.3KV(105A) COMPACT RACK TYPE MEDIUM VOLTAGE INVERTER SYSTEM (3.3kV(105A) COMPACT RACK TYPE 고압 인버터 시스템의 방열 성능 향상을 위한 열유동 해석)

  • Kim, S.Y.;Kim, S.D.;Ryoo, S.R.;You, N.K.;Kim, T.B.;Hong, C.O.;Ko, H.S.
    • Journal of computational fluids engineering
    • /
    • v.19 no.3
    • /
    • pp.24-28
    • /
    • 2014
  • With ever rising concerns about saving of fossil fuel resource, there have been an increasing demand for use of energy more efficiently. The electric motor driven inverters can be a great help to improve energy efficiency. They are also used to control the motor speed to the actual need. Therefore the use of them can lead to reduce energy consumption. In particular, the medium voltage(MV) drive systems used for pumps, fans, steel rolling mills and tractions have widespread applications in the industry. They cover power ratings from 0.4MW to 40MW at the MV level of 2.3kV to 13.8kV. The majority of the installed MV drive systems however, are in the 1MW to 4MW range with voltage rating from 3.3kV to 6.6kV. But they are required to reduce size and weight like other power electronic equipments. In this paper, we studied on the 3.3kV(105A) compact rack type inverter system for improving the cooling efficiency. At first, we confirmed the tendency of temperature with computational simulation using ANSYS ICEPAK and actual experimental tests. And then we researched thermal performance improvement designs in order to reduce temperature of the transformer for the safe operation. It can reduce temperature of transformer that using pipe type flow guide in the system. As a result, we found out more efficient solution by thermal-fluid analysis.

Analysis of Truck Management Strategies Impacts on Highway (고속도로 상에서의 트럭교통 관리전략에 대한 영향 분석)

  • Yang, Choong-Heon;Son, Young-Tae
    • International Journal of Highway Engineering
    • /
    • v.11 no.2
    • /
    • pp.175-184
    • /
    • 2009
  • The study analyzes likely impacts of left truck lane restriction strategies on urban freeways based on a traffic simulation model. This study contains two main parts. The first part is performed to develop feasible alternatives as well as provide insights into conditions under left truck lane restrictions would be effective based on the analysis of two representative hypothetical highways. Different levels of O-D demands and truck percentage is at least restrictions would work when maximum rate of flow is more than 1,300vphpl or truck percentage is at least over loft of the total traffic. The second part of our study concerns a case study on a region with perhaps the highest truck volumes in the U.S. - a northbound section of Interstate 710 corridor in Los Angeles County, Southern California. The results show that restricting the two leftmost lanes under congested traffic with heavy ruck use, provides the most positive impacts in terms of improving the flow of traffic and saving fuel. In addition, our study demonstrates that in general, the number of lanes restricted is a crucial factor in the success of this strategy.

  • PDF

A Study of GHG-AP Integrated Inventories and Alternative Energy Use Scenario of Energy Consumption in the University (대학 내 에너지 소비에 따른 온실가스-대기오염 통합 인벤토리 및 대체 에너지 사용 시나리오 분석)

  • Jung, Jae-Hyung;Kwon, O-Yul
    • Journal of Environmental Science International
    • /
    • v.23 no.9
    • /
    • pp.1643-1654
    • /
    • 2014
  • The university is one of the main energy consumption facilities and thereby releases a large amount of greenhouse gas (GHG). Accordingly, efforts for reducing energy consumption and GHG have been established in many local as well as international universities. However, it has been limited to energy consumption and GHG, and has not included air pollution (AP). Therefore, we estimated GHG and AP integrated emissions from the energy consumed by Seoul National University of Science and Technology during the years between 2010 and 2012. In addition, the effect of alternative energy use scenario was analysed. We estimated GHG using IPCC guideline and Guidelines for Local Government Greenhouse Inventories, and AP using APEMEP/EEA Emission Inventory Guidebook 2013 and Air Pollutants Calculation Manual. The estimated annual average GHG emission was $11,420tonCO_{2eq}$, of which 27% was direct emissions from fuel combustion sectors, including stationary and mobile source, and the remaining 73% was indirect emissions from purchased electricity and purchased water supply. The estimated annual average AP emission was 7,757 kgAP, of which the total amount was from direct emissions only. The annual GHG emissions from city gas and purchased electricity usage per unit area ($m^2$) of the university buildings were estimated as $15.4kgCO_{2eq}/m^2$ and $42.4tonCO_{2eq}/m^2$ and those per person enrolled in the university were $210kgCO_{2eq}$/capita and $577kgCO_{2eq}$/capita. Alternative energy use scenarios revealed that the use of all alternative energy sources including solar energy, electric car and rain water reuse applicable to the university could reduce as much as 9.4% of the annual GHG and 34% of AP integrated emissions, saving approximately 400 million won per year, corresponding to 14% of the university energy budget.

Analysis of Charging Phenomenon of 2-Cavity Die Casting for Automobile's Valve Housing (자동차 VALVE HOUSING용 2-CAVITY 다이캐스팅의 충전 현상 분석)

  • Lee, Jong-Hyung;Yoon, Jong-Cheul;Yoo, Duck-Sang;Lee, Chang-Heon;Ha, Hong-Bae
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.9 no.1
    • /
    • pp.61-66
    • /
    • 2006
  • In perspective of saving natural resource and energy, today's automobiles are in process of regenerating by smaller and lighter. In order to achieve the sufficiency on the consumption of the fuel, new mechanism and new assembly are required. Therefore the expectations on the new materials are very high. Especially, AI materials are widely used to reduce the weight. AI that is used in automobiles is mostly casting material, and according to the innovation of technique is in rapid development. AI Die casting is an important field as today's trend of lightweight on automobiles. One of the parts in steering system, Valve Housing plays a role of reduce the operating effort of drivers. Unfortunately, the Valve Housing which is widely reliable to the most automobiles are not developed at this moment in our automobile industry. Therefore, they are produced by casting method which cost three times or even more expensive in production. If Valve Housing, which is a part of steering system is produced by Gravity Casting, the space that manufacturing equipment will be increased, and more time and workers would be brought into service. For such reason, Die Casting would replace Gravity Casting in order to minimize cost of time, manpower, and working space.

  • PDF

Power supply performance photovoltaic (PV) system for 3-ton class fishing vessel (3톤급 연안어선용 태양광 발전장치의 전원공급 성능)

  • Jeong, Seong-Jae;Lee, Dong-Gil;Park, Seong-Wook;Kim, Hee-Jin
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.50 no.4
    • /
    • pp.487-494
    • /
    • 2014
  • This study describes the result on PV system for evaluating the performance of small fishing boats. Photovoltaic system with 200 watts power generation facilities on the 3-ton fishing boat was carried. Load test was performed on the condition that the work lamps lit during night operations. As a result the performance can be used for more than two hours at 60 watt work lamps. The load test was performed on the condition that fishing vessels are on the cruising condition at sea. The solar power systems have been investigated as a power generation efficiency of about 36.55%. Additional tests show that the power generation efficiency is difficult to expect a maximum of 50% or more. Fuel consumption of fishing boats by installing a solar power system is reduced. Also the PV system is useful for the verification of their availability for fishing vessels as well as the satisfaction of the fishermen. The results for the durability of the photovoltaic device is acceptable, including a solar panel, controller and the performance exhibited no breakage in the harsh marine environment or failure so far. The installed PV system was confirmed that the durability with at least 2 years.

Analyzing Efficiency in the Seoul's Urban Bus Industry Using Data Envelopment Analysis (자료포락분석기법(DEA)을 이용한 서울 시내버스운송업의 효율성 분석)

  • 오미영;김성수;김민정
    • Journal of Korean Society of Transportation
    • /
    • v.20 no.2
    • /
    • pp.59-68
    • /
    • 2002
  • Using 1996 annual observations for 69 bus firms in Seoul, this paper measures firm-level efficiency with data envelopment analysis(DEA) and identifies firm characteristics indicative of differential efficiency in these firms with Tobit regression analysis. The paper then conceptualizes that these firms produce two kinds of output(city/seat bus kilometers or city/seat bus Passengers) using four inputs (labor vehicle, fuel and maintenance). The findings show that, on an average, these firms have only a little input saving potential of 0.9 percent, while not a little output increasing potential of 12.9 percent. On the other hand, it is discovered that these firms operate more efficiently with a lower ratio of maintenance employees to total employees. Furthermore, it appears that both the ratio of seat buses to total buses and average speeds positively affect efficiency in this industry.

Synthesis of Pt@TiO2 Nano-composite via Photochemical Reduction Method (광화학 환원방법을 이용한 Pt@TiO2 나노 복합체 합성)

  • Kim, Ji Young;Byun, Jong Min;Kim, Jin Woo;Kim, Young Do
    • Journal of Powder Materials
    • /
    • v.21 no.2
    • /
    • pp.119-123
    • /
    • 2014
  • Pt has been widely used as catalyst for fuel cell and exhausted gas clean systems due to its high catalytic activity. Recently, there have been researches on fabricating composite materials of Pt as a method of reducing the amount of Pt due to its high price. One of the approaches for saving Pt used as catalyst is a core shell structure consisting of Pt layer on the core of the non-noble metal. In this study, the synthesis of Pt shell was conducted on the surface of $TiO_2$ particle, a non-noble material, by applying ultraviolet (UV) irradiation. Anatase $TiO_2$ particles with the average size of 20~30 nm were immersed in the ethanol dissolved with Pt precursor of $H_2PtCl_6{\cdot}6H_2O$ and exposed to UV irradiation with the wavelength of 365 nm. It was confirmed that Pt nano-particles were formed on the surface of $TiO_2$ particles by photochemical reduction of Pt ion from the solution. The morphology of the synthesized Pt@$TiO_2$ nano-composite was examined by TEM (Transmission Electron Microscopy).

Analysis of Heat Exchanging Performance of Heat Recovering Device Attached to Exhaust Gas Duct (열회수장치에 의한 열회수성능 분석)

  • 서원명;윤용철;강종국
    • Journal of Bio-Environment Control
    • /
    • v.9 no.4
    • /
    • pp.212-222
    • /
    • 2000
  • This study was performed to investigate the performance of heat recovery device attached to exhaust gas flue connected to combustion chamber of greenhouse heating system. The experimental heat recovery system is mainly consisted of LPG combustion chamber and two heat recovery units; unit-A is attached directly to the exhaust gas flue, and unit-B is connected with unit-A. Heat recovery performance was evaluated by estimating total energy amounts by using enthalpy difference between two measurement points together with mass flow rate of gas and/or air passing through each heat recovery unit depending on 5 different flow rates controlled by voltage meter. The results of this experimental study, such as heat exchange behavior of supply air tubes and exhaust air passages crossing the tubes, pressure drop between inlet and outlet, heat recovery performance of exchange unit, etc., will be used as fundamental data for designing optimum heat recovery device to be used for fuel saving purpose by reducing heat loss amounts mostly wasted outside of greenhouse through flue.

  • PDF