• Title/Summary/Keyword: Fuel side

Search Result 348, Processing Time 0.023 seconds

Characteristics of NOx emission in lobed burner (로브형 버너에서의 NOx 배출특성)

  • Cho, H.C.;Cho, K.W.;Lee, Y.K.
    • 한국연소학회:학술대회논문집
    • /
    • 2000.12a
    • /
    • pp.140-147
    • /
    • 2000
  • Using lobed burner, flame visualization and measurements of NOx and CO concentration in the combustor exit were carried out to evaluate the relation between the lobed structure in a burner and pollutant emission characteristics. The flame stability is enhanced by the lobed burner compared to conventional circular one. The correlation on fuel discharge velocity for flame blowout should be included on a variable related to the wall effect of the burner, because the flame blowout is observed at the burner having large perimeter. The burner having lobed structure in fuel discharge side compared to conventional burner reduces by 5% NOx emission due to lower flame intensity through flame elongation. Meanwhile the burner having lobed structure in air discharge side and both fuel and air discharge side increase the NOx emission.

  • PDF

Develolpment of Heat Exchanger for the Humidifier of 3MW MCFC (3MW급 MCFC용 가습기 개발)

  • Kim, Seonhwa;Oh, Yongmin;Kim, Jaesig;Lee, Jeajun
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.88.1-88.1
    • /
    • 2010
  • In recent days, the study for the renewable energy is required to supplement traditional energy source. One of the renewable energy of Fuel Cell is classified according to the electrolytes. It is the MCFC (Molten Carbonate Fuel Cell) for this study. One of the equipments of the heat exchangers is important component for efficiency and cost. In MCFC system, several heat exchangers are used according to the application. It is named for the humidifier because it is to preheat the fuel and water so that a reactor will convert some of the incoming fuel to hydrogen. Then, hot side fluid service is used the exhausted gas from the fuel cell and cold side fluid service is the fuel and water. The operation temperature range is about 25~500 Celsius Degree. This heat exchanger has the problems of heat transfer considering to multiphase fluid and phase changing. So it is necessary to analyze the heat transfer characteristics and to propose the reasonable design methodology for the humidifier. In this study, the thermal characteristic for the humidifier is estimated by using commercial tool of heat exchanger design and rating. And this study provides the testing methodology and presents the results for test facility of fabrication and for testing.

  • PDF

The Performance Analysis of Polymer Electrolyte Membrane Fuel Cells for Mobile Devices using CFD (CFD를 이용한 모바일기기용 고분자전해질 연료전지 성능해석)

  • Kim B.H.;Choi J.P.;Kang D.C.;Jeon B.H.
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2006.05a
    • /
    • pp.553-554
    • /
    • 2006
  • This paper presents the effects of different operating parameters on the performance of a proton exchange membrane (PEM) fuel cell by a three-dimensional computational fluid dynamics (CFD) model. The effects of different operating parameters on the performance of PEM fuel cell studied using pure hydrogen on the anode side and air on the cathode side. The various parameters are temperatures, pressures, humidification of the gas steams and various combinations of these parameters. In addition, geometrical and material parameters such as the gas diffusion layer (GDL) thickness and porosity as well as the ratio between the channel width and the land area were investigated.

  • PDF

An Experimental Analysis of the Effects of Water Vapor Partial Pressure in Inlet Air, Spark Advance and Fuel Type on the Flame Propagation in a Spark Ingnition Engine (흡기중의 수증기분압과 점화시기 및 연료 변화에 따른 스파크 점화기관의 화염 전파 특성 분석)

  • 이택헌;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.6 no.5
    • /
    • pp.191-198
    • /
    • 1998
  • In this study, the effects of water vapor in inlet air, spark advance and fuel type in the spark ignition engine were investigated through the experiments of combustion and flame arriving pattern analysis using ionization probe. The results of flame propagation experiment using ionization probe show that the flame which ignited from spark plug located at the center of the combustion chamber propagated faster in exhaust side than in intake side due to the mixture flow motion inducted into combustion chamber from intake tumble port at all conditions. And as the partial vapor pressure increased, the flame propagation became slower in all direction. Especially effects were greater for intake side than the exhaust side.

  • PDF

Performance Prediction of Side Channel Type Fuel Pump (사이드채널형 연료펌프의 성능예측)

  • Choi, Young-Seok;Lee, Kyoung-Yong;Kang, Shin-Hyoung
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.2 s.19
    • /
    • pp.29-33
    • /
    • 2003
  • The periphery pump (or regenerative pump) has been generally applied in the automotive fuel pump due to their low specific speed (high heads and small flow rate) with stable performance curves. In this study, the performance prediction of side channel type periphery pumps has been developed. The prediction of the circulatory flow rate is based on the consideration of the centrifugal force field in the side-channel and in the impeller vane grooves. For the determination of performance curve (head-flow rate), momentum exchange theory is used. The effects of various geometric parameters and loss coefficients used in the performance prediction method on the head and efficiency are discussed, and the results were compared with experimental data.

Performance Prediction of Side Channel Type Fuel Pump (사이드채널형 연료펌프의 성능예측)

  • Choi Y. S.;Lee K. Y.;Kang S. H.
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.581-584
    • /
    • 2002
  • The periphery pump(or regenerative pump) has been generally applied in the automotive fuel pump due to their low specific speed(high heads and small flow rate) with stable performance curves. In this study, the performance prediction of side channel type periphery pumps has been developed. The prediction of the circulatory flow rate is based on the consideration of the centrifugal force field in the side-channel and in the impeller vane grooves. For the determination of performance curve(head-flow rate), momentum exchange theory is used. The effects of various geometric parameters and loss coefficients used in the performance prediction method on the head and efficiency are discussed and the results were compared with experimental data.

  • PDF

Effects of Fuel-Side dilution and Pressure on Structure and Extinction Scalar Dissipation Rate of Syngas Nonpremixed Flames (질소희석과 압력이 석탄가스 비예혼합 화염구조와 소염 스칼라 소산율에 미치는 영향 해석)

  • Park, Sangwoon;Shin, Youngjun;Kim, Yongmo
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.61-62
    • /
    • 2012
  • The present study has numerically investigated the effects of fuel-side dilution and pressure on flame structure and extinction scalar dissipation rate of turbulent syngas nonpremixedd flames. Numerical results indicate that for highly diluted case, peak temperature is decreased and stoichiometric mixture fraction is increased. By decreasing the pressure and the nitrgen dilution levelcreased, the extinction scalar dissipation rate is increased.

  • PDF

Study on Safety Evaluation Process for Hydrogen Storage System of Hydrogen Bus (수소버스 수소저장용기의 측면충돌 안전성 평가방법 연구)

  • Kyungjin, Kim;Jaeho, Shin;Kyeonghee, Han;Hyeon Min, Han;Jeong Min, In;Siwoo, Kim
    • Journal of Auto-vehicle Safety Association
    • /
    • v.14 no.4
    • /
    • pp.113-119
    • /
    • 2022
  • The structural safety of hydrogen buses is being evaluated for the successful introduction of hydrogen buses. The crash test methodology, for example, side impact test procedure is being discussed for hydrogen bus structure safety with a compressed hydrogen storage system located under the bus floor. Thus this study describes a new experiment method for side impact test with compressed hydrogen storage system independently based on finite element analysis instead of side impact test using full hydrogen bus. A side crash procedure of conceptual compressed hydrogen storage structure was investigated and impact simulations were performed. The finite element models of hydrogen bus, simplified structures, fuel tank system and side impact moving barrier were set up and simulation results reported model performance and result comparison of three different simplified models. Computational results and research discussion proposed the fundamental test framework for safety assessment of the compressed hydrogen storage system.

A Study on Operation Characteristics of Planar-type SOFC System Integrated with Fuel Processor (연료개질기를 연계한 고체 산화물 연료전지 시스템의 운전 특성에 관한 연구)

  • Ji Hyun-Jin;Lim Sung-Kwang;Yoo Yung-Sung;Bae Joong-Myeon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.30 no.8 s.251
    • /
    • pp.731-740
    • /
    • 2006
  • The solid oxide fuel cell (SOFC) is expected to be a candidate for distributed power sources in the next generation, due to its high efficiency and high-temperature waste heat utilization. In this study, the 5-cell SOFC stack was operated with pure hydrogen or reformed gas at anode side and air at cathode side. When stack was operated with diesel and methane ATR reformer, the influence of the $H_2O/C,\;O_2/C$ and GHSV on performance of stacks have been investigated. The result shows that the cell voltage was decreased with the increase of $H_2O/C$ and $O_2/C$ due to the partial pressure of fuel and water, and cell voltage was more sensitive to $O_2/C$ than $H_2O/C$. Next, the dynamic model of SOFC system included with ATR reformer was established and compared with experimental data. Based on dynamic model, the operation strategy to optimize SOFC-Reformer system was suggested and simulated.

Vacuum Die Casting Mold Design of Fuel Cell Bipolar Plate using Die Filling Simulation and Experimental Verification (금형 충전 해석을 이용한 연료전지 분리판 진공 다이캐스팅 금형 설계 방안 및 실험 검증)

  • Jin, Chul-Kyu;Jang, Chang-Hyun;Kang, Chung-Gil
    • Journal of Korea Foundry Society
    • /
    • v.32 no.2
    • /
    • pp.65-74
    • /
    • 2012
  • In this paper, we present the results of our studies on optimal die design towards development of a vacuum die casting process to fabricate fuel cell bipolar plate with micro-channel array. Cavity and overflow shape is designed by computational filling analysis of MAGMA soft. Optimal die design consists of seven overflows at the end of cavity and three overflows at each side wall of cavity. The molten metal that passed the gate and reached the side wall flowed into the side overflow, no turbulent flow occurred, and the filling behavior and velocity distribution were uniform. In addition, partially solidified molten metal passing through the channel was perfectly eliminated by overflow without back-flow. When vacuum pressure, injection speed of low and high region was 300 mbar, 0.3 m/s and 2.5 m/s respectively with Silafont 36 die casting alloy, sound sample without casting defects was obtained. The experimental results are nearly consistent with simulation results.