• 제목/요약/키워드: Fuel cell power plant

검색결과 122건 처리시간 0.049초

고온 연료전지 발전단지의 내부계통 고장에 의한 운전환경에 대한 분석 (A Study on the Operation Condition by Electrical Fault in the High Temperature Fuel Cell Plant)

  • 정영환;채희석;김재철;조성민
    • 조명전기설비학회논문지
    • /
    • 제27권8호
    • /
    • pp.51-59
    • /
    • 2013
  • High temperature fuel cell system, such as molten carbonate fuel cells(MCFC) and solid oxide fuel cells(SOFC), are capable of operating at MW rated power output. The power output change of high temperature fuel cell imposes the thermal and mechanical stresses on the fuel cell stack. To minimize the thermal-mechanical stresses on the stack, increases in the power output of high temperature fuel cell typically must be made at a slow rate. So, the short time interruption of high temperature fuel cell causes considerable generated energy losses. Because of the characteristic of high temperature fuel cell, we analyzed the impact of electrical fault in the fuel cell plant on other fuel cell generators in the same plant site. A various grounding configuration and voltage sag are analyzed. Finally, we presented the solution to minimize the effect of fault on other fuel cell generators.

내부고장을 고려한 고온형 연료전지 대규모 발전단지의 병렬운전 변압기 적정 뱅크수에 관한 연구 (A Study on the Proper Number of Banks of Parallel Operation of Transformer in Large-scale Power Plants Using the High Temperature Fuel Cell Considering the Internal Failure)

  • 정영환;채희석;성인제;김재철
    • 조명전기설비학회논문지
    • /
    • 제28권3호
    • /
    • pp.26-31
    • /
    • 2014
  • High temperature fuel cell system, such as molten carbonate fuel cells(MCFC) and solid oxide fuel cells(SOFC), are capable of operating at MW rated power output. The power output change of high temperature fuel cell imposes the thermal and mechanical stresses on the fuel cell stack. To minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we should divide the power plant configuration to several banks. However, the improvement of reliability in fuel cell power plant system causes an increase of the investment cost, for example, replacement costs, labor costs, and so on. For this reason - the balance between investment and reliability improvement - many studies about the appropriate level of investment have been conducted. In this paper, we evaluate the cost for operation and installation, the benefit for electric energy and thermal energy sales, and the system reliability for several cases : these cases relate with the bank configuration.

연료전지 발전 시스템의 최적운전을 위한 지능제어 기법 (An Intelligent Control Method for Optimal Operation of a Fuel Cell Power System)

  • 황진권;최태일
    • 조명전기설비학회논문지
    • /
    • 제23권12호
    • /
    • pp.154-161
    • /
    • 2009
  • 연료전지 발전 시스템은 비선형성을 내포한 다수의 제어 루로들로 구성된 매우 복잡한 형태의 시스템이다. 연료전지 발전 시스템의 제어를 위하여 연료전지의 스텍 모델이 개발되고 있으며 연료전지 발전 시스템의 간략화된 프로세스 흐름도도 제시되고 있다. 본 연구에서는 이러한 모델을 사용하여 연료전지 발전 시스템을 지능적으로 제어할 수 있는 I-SRG(Intelligent Setpoint Reference Governor)를 개발한다. I-SRG는 시스템의 제약조건과 성능목표에 대한 최적의 운전 설정치를 산출하고 각 제어 루프의 앞먹임 제어입력을 생성한다. I-SRG는 PSO(Particle Swarm Optimization) 알고리즘을 최적화 기법에 사용하고 신경회로망으로 구현되어진다. MCFC 발전 시스템의 전력 프로파일에 대한 추종 제어의 모의실험을 수행하여 제안된 I-SRG의 유용성을 보인다.

원자력 발전소의 해수전해설비 폐수소를 활용한 PEM 연료전지 발전 시스템에 관한 연구 (A study on the power plant system combined with PEM fuel cell and the wasted hydrogen from the sea water electrolyzer of nuclear power plants)

  • 최종원;이주형;차석원;김민수
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 춘계학술대회 초록집
    • /
    • pp.124.2-124.2
    • /
    • 2010
  • Generally, a coolant of the nuclear power plant is manufactured by electrolyzing the sea water near the plant for making the sodium hypochlorite(NaOCl), which is used for sterilizing the bacteria and the shellfishes sticking to the drains or the pumps at the outlet of the cooling system due to $8-10^{\circ}C$ warmer temperature than the inlet sea water. During manufacturing the sodium hypochlorite, the hydrogen with the high purity is also produced at the anode side of the electrolyzer. This paper describes a novel power plant system combined with the polymer electrolyte membrane(PEM) fuel cell, the wasted hydrogen from the sea water electrolyzer and the wasted heat of the nuclear power plant. The present status over the exhausted hydrogen at twenty nuclear power plants in Korea was investigated in this study, from which an available power generation is estimated. Furthermore, the economic feasibility of the PEM fuel cell power plant is also evaluated by a current regulations over the power production and exchange using a renewable energy shown in Korea Power Exchange(KRX).

  • PDF

연료전지 발전을 위한 바이오가스정제 (Biogas Purifying for Fuel cell Power Plant)

  • 이종규;전재호
    • 상하수도학회지
    • /
    • 제21권4호
    • /
    • pp.439-444
    • /
    • 2007
  • Using the anaerobic digester gas as a fuel, fuel cells have the potential to provide significant environmental and economic benefits. A molten carbonate fuel cell power plant was installed in the municipal sewage works of Tancheon in Seoul. The fuel cell unit operates on anaerobic digester gas and provides power and heat for the sewage works. This is the first project of its kind in Korea. This article outlines the experiences of gas purification process with planning, installation and operation. The engineering and installation phase is described regarding to the special features of digester gas, for example impurities in gas composition. Such impurities would be harmful to fuel cells. Operational results from the field test with a gas purification process plant are presented in this paper.

Application of SFCL on Bus Tie for Parallel Operation of Power Main Transformers in a Fuel Cell Power Systems

  • Chai, Hui-Seok;Kang, Byoung-Wook;Kim, Jin-Seok;Kim, Jae-Chul
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권6호
    • /
    • pp.2256-2261
    • /
    • 2015
  • In the power plant using high temperature fuel cells such as Molten Carbonate Fuel Cell(MCFC), and Solid Oxide Fuel Cell(SOFC), the generated electric power per area of power generation facilities is much higher than any other renewable energy sources. - High temperature fuel cell systems are capable of operating at MW rated power output. - It also has a feature that is short for length of the line for connecting the interior of the generation facilities. In normal condition, these points are advantages for voltage drops or power losses. However, in abnormal condition such as fault occurrence in electrical system, the fault currents are increased, because of the small impedance of the short length of power cable. Commonly, to minimize the thermal-mechanical stresses on the stack and increase the systems reliability, we divided the power plant configuration to several banks for parallel operation. However, when a fault occurs in the parallel operation system of power main transformer, the fault currents might exceed the interruption capacity of protective devices. In fact, although the internal voltage level of the fuel cell power plant is the voltage level of distribution systems, we should install the circuit breakers for transmission systems due to fault current. To resolve these problems, the SFCL has been studied as one of the noticeable devices. Therefore, we analyzed the effect of application of the SFCL on bus tie in a fuel cell power plants system using PSCAD/EMTDC.

태양전지-연료전지 복합 전력시스템에 대한 환경평가에 관한 연구 (Environmental Evaluation for a Photovoltaic-Fuel Cell Hybrid Power System)

  • 노경수
    • 조명전기설비학회논문지
    • /
    • 제12권3호
    • /
    • pp.83-88
    • /
    • 1998
  • 본 논문은 태양전지 연료전지 복합 전력시스랩에 대한 환경평가를 다목적함수의해 선정 보조시스템의 하나언 이상점 기법올 통하여 다루고자 한다. 그에 대한 평가는 발전소 건설에 필요한 부지량과 건설에서 해체때까지의 이산화탄소 배출량의 관점에서 이루어지며 그 결과는 기존의 화석연료 발전시스템들과 비교되어진다. 연료전지 발전은 이미 변덕스러운 날씨하에서 극심한 태양전지의 출력량 변회를 보상하기 위한 적절한 발전기술엄이 증명 되었다. 가장 적은 부지량을 필요로 하는 연료전지 발전은 태양전지 발전시스템의 과도한 부지 펼요량올 경감시 킬 수 있으며 그 태양전지-연료전지 복합 전력시스템은 건셜에서 해체때까지의 이산화탄소 배출량 면에서도 가장 적은 영향올 미치는 것으로 나타난다.

  • PDF

Power Control and Ground Fault Simulations for a Distribution System with a Fuel Cell Power Plant

  • Hwang, Jin-Kwon;Choi, Tae-Il
    • 조명전기설비학회논문지
    • /
    • 제24권7호
    • /
    • pp.9-19
    • /
    • 2010
  • Fuel cell (FC) distributed generation (DG) is gradually becoming more attractive to mainstream electricity users as capacity improves and costs decrease. New technologies including inverters are becoming available to provide a uniform standard interconnection of DGs with an electric power system. Some of the operating conflicts and the effect of DG on power quality are addressed and investigated through simulations on a real distribution network with an FC power plant. The results of these simulations have proved load tracking capability following the real and reactive power change of the load and have shown the flow of overcurrent from an FC power plant during the ground fault of a distribution line.

식물-미생물전기화학 기반의 미활용 에너지 회수 기초 연구 (Basic Study for Harvesting Unused Energy based on Plant-Microbial Electrochemical Technology)

  • 유재철;신춘환
    • 한국환경과학회지
    • /
    • 제28권2호
    • /
    • pp.219-224
    • /
    • 2019
  • In this study, we evaluated the energy production from plant-microbial fuel cells using representative indoor plants, such as Scindapsus aureus and Clatha minor. The maximum power density of microbial fuel cell (MFC) using S. aureus ($3.36mW/m^2$) was about 2 times higher than that of the MFC using C. minor ($1.43mW/m^2$). It was confirmed that energy recovery is possible using plant-MFCs without fuel. However, further research is needed to improve the performance of plant-MFCs. Nevertheless, plant-MFCs have proved their potential as a novel energy source to overcome the limitations of the conventional renewable energy sources such as wind power and solar cells, and could be employed to a power source for the sensor in charge of the fourth industrial revolution.

연료전지발전용 부스터의 출력전압제어 연구 (Control of Booster Output Voltage in Fuel Cell Power Plant)

  • 한수빈;정봉만;신동열;최수현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1992년도 하계학술대회 논문집 B
    • /
    • pp.1038-1040
    • /
    • 1992
  • Booster is used widely as one of the step-up DC/DC power converter in power conversion process for fuel cell power plant which have the electrical characteristic of the high current density and low cell voltage. In view of control system, booster can be unstable when it is operated in broad operation range because the transfer function of booster has zero in right half plane of s-domain. So for reliable operation, controller must make the system stable in whole working range. In this paper, the two control method such as digital PID control and fuzzy control is studied for booster output voltage regulation in fuel cell plant. The design procedure of PID control and fuzzy control is described. And the experiment of designed controller action is performed in various operation points for controller performance test.

  • PDF