• Title/Summary/Keyword: Fuel behavior

Search Result 1,159, Processing Time 0.025 seconds

Thermal-Hydraulic Analysis of Pipeline Transport System for Marine Geological Storage of Carbon Dioxide (이산화탄소 해양지중저장 처리를 위한 파이프라인 수송시스템의 열-유동 해석)

  • Huh, Cheol;Kang, Seong-Gil;Hong, Sup;Choi, Jong-Su;Baek, Jong-Hwa
    • Journal of Ocean Engineering and Technology
    • /
    • v.22 no.6
    • /
    • pp.88-94
    • /
    • 2008
  • The concentration of atmospheric carbon dioxide (CO2), which is one of the major greenhouse gases, continues to rise with the increase in fossil fuel consumption. In order to mitigate global warming the amount of CO2 discharge to the atmosphere must be reduced. Carbon dioxide capture and storage (CCS) technology is now regarded as one of the most promising options. To complete the carbon cycle in a CCS system, a huge amount of captured CO2 from major point sources such as power plantsshould be transported for storage into the marine or ground geological structures. Since 2005, we have developed technologies for marine geological storage of CO2,including possible storage site surveys and basic design of CO2 transport and storage process. In this paper, the design parameters which will be useful to construct on-shore and off-shore CO2 transport systems are deduced and analyzed. To carry out this parametric study, we suggested variations in thedesign parameters such as flow rate, diameter, temperature and pressure, based on a hypothetical scenario. We also studied the fluid flow behavior and thermal characteristics in a pipeline transport system.

Experimental and Numerical Analysis of DME Spray Characteristics in Common-rail Fuel System (커먼레일 연료시스템에서의 DME 분무 특성에 대한 실험과 해석적 연구)

  • Jeong, Soo-Jin;Park, Jung-Kwon;Lee, Sang-In;Lim, Ock-Taeck
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1151-1159
    • /
    • 2012
  • Spray visualization and computer simulation of a DME injector have been conducted to investigate the enlarged injection hole diameter effect. To increase the reliability of the computational result, simulation results have been compared with the visualization test results, and the behaviors of a DME spray under various high-pressure and -temperature conditions have been computed. This study shows a discrepancy of 3.57% between the experimental and the computational results of penetration length for an injection pressure of 35 MPa and ambient pressure of 5 MPa. When simulating the engine conditions, the maximum penetration length of a fully developed DME spray is 42 mm when the temperature to pressure ratio is 300 K/MPa. The DME spray behavior is dominantly affected by the ambient pressure under the condition that the ratio is less than 300 K/MPa, and by the ambient temperature under the condition that the ratio is more than 300 K/MPa.

A Study on Flame Structure and NO Emission in FIR- and FGR-applied Methane-air Counterflow Diffusion Flames (FIR과 FGR 기법이 적용된 메탄-공기 대향류 확산화염에서 화염구조와 NO 배출 연구)

  • Park, Jeong;Kwon, Oh Boong;Kim, Sewon;Lee, Changyeop;Keel, Sang-In;Yun, Jin-Han;Lim, In Gweon
    • Journal of the Korean Society of Combustion
    • /
    • v.21 no.1
    • /
    • pp.38-45
    • /
    • 2016
  • Flame characteristics and NO emission behavior in $CH_4$/air-air premixed counterflow flames with applying FIR and FGR with $CO_2$ and $H_2O$ were investigated numerically by varying the ratios of FIR and FGR as well as global strain rate. Chemical effects of added $CO_2$ and $H_2O$ via FIR and FGR were analyzed through comparing flame characteristics and NO behaviors from real species($CO_2$ and $H_2O$) with those from their artificial species($XCO_2$ and $XH_2O$) which have the same thermochemical, radiative, and transport properties to those for the real species. The results showed that flame temperature and NO emission with FIR varied much more sensitively than that with FGR. Those varied little irrespective of adding $CO_2$, $H_2O$, and their artificial species to the fuel stream via FIR. However, Those were varied complicatedly by chemical effects of added $CO_2$ and $H_2O$ via FGR. Detailed analyses for them were made and discussed.

Effect of AC Electric Field on Decreasing Liftoff Height in Laminar Lifted Jet Flames (층류 부상 화염의 화염부상 높이 감소 구간에서 교류 전기장이 인가된 화염에 관한 영향)

  • Seo, B.H.;Van, K.H.;Kim, G.T.;Park, J.;Keel, S.I.;Kim, S.W.;Chung, S.H.
    • Journal of the Korean Society of Combustion
    • /
    • v.22 no.3
    • /
    • pp.17-22
    • /
    • 2017
  • An experimental study has been conducted to elucidate the effect of AC electric field on behaviors of laminar lifted flame in nitrogen-diluted methane coflow-jets. Our concerns are focued on the regime to show a decrease in liftoff height, $H_L$ with increasing nozzle exit velocity, $U_O$ (hereafter, $decreasing-H_L$). The $H_L$ with $U_O$ near flame extinction were measured by varying the applied AC voltage, $V_{AC}$ and frequency, $f_{AC}$ in a single electrode configuration. The behavior of $H_L$ with a functional dependency of $V_{AC}$ and $f_{AC}$ was categorized into two regime : (I) $H_L$ decreased for nozzle diameter, D = 1.0 mm, and (II) $H_L$ increased in the increase of $f_{AC}$ for a fixed $V_{AC}$ in a D = 4.0, 8.4 mm. The lifted flames in $decreasing-H_L$ region was unstable in high voltage regimes while the $H_L$ showed a decreasing tendency with $U_O$ except them. Such behaviors in $H_L$ were also characterized by functional dependencies of related physical parameters such as $V_{AC}$, $f_{AC}$, $U_O$, fuel mole fraction ($X_{F.O}$) and D.

An Analytical Evaluation on the flue Gas and Combustion Efficiency of Emulsion Fuel (에멀죤 연료의 연소 배출가스특성 및 연소 효율에 관한 분석평가)

  • Park, Hyun-Mee;Eo, Yun-Woo;Baig, Seung-Woo;Park, Il Yong;Paeng, Ki Jung;Kim, Young-Man;Lee, Kang-Bong
    • Analytical Science and Technology
    • /
    • v.15 no.5
    • /
    • pp.427-432
    • /
    • 2002
  • The combustion behavior of heavy oil and its emulsion with water was evaluated. The concentration of $SO_x$ in the combustion gas of emulsion oil was reduced to 57% with respect to that of the combustion gas from neat heavy oil. Also, the concentration of $NO_x$ in the combustion gas of emulsion oil was reduced to 67% with respect to that of the combustion gas of neat heavy oil. These reductions of $SO_x$ in the combustion gas of emulsion oil seems to be due to the reaction with salts included in surfactant of emulsion oil. Also, the combustion efficiency of emulsion oil is evaluated to be about 6% higher than that of neat heavy oil.

Dry Friction Characteristics of Bulk Amorphous Thermal Spray Coating and Amorphous Metallic Matrix Composites (벌크 비정질 용사코팅과 비정질 기지 복합재료의 건조 마찰특성)

  • Jang, Beomtaek;Yi, Seonghoon
    • Tribology and Lubricants
    • /
    • v.30 no.2
    • /
    • pp.108-115
    • /
    • 2014
  • The friction behaviors of bulk amorphous thermal spray coating (BAC) and second phase-reinforced composite coatings using a high velocity oxy-fuel spraying process were investigated using a ball-on-disk test rig that slides against a ceramic ball in an atmospheric environment. The surface temperatures were measured using an infrared thermometer installed 50 mm from the contact surface. The crystallinities of the coating layers were determined using X-ray diffraction. The morphologies of the coating layers and worn surfaces were observed using a scanning electron microscope and energy-dispersive spectroscopy. The results show that the friction behavior of the monolithic amorphous coating was sensitive to the testing conditions. Under lower than normal loads, a low and stable friction coefficient of about 0.1 was observed, whereas under a higher relative load, a high and unstable friction coefficient of greater than 0.3 was obtained with an instant temperature increase. For the composite coatings, a sudden increase in friction coefficient did not occur, i.e., the transition region did not exist and during the friction test, a gradual increase occurred only after a significant delay. The BAC morphology observations indicate that viscous plastic flow was generated with low loads, but severe surface damage (i.e., tearing) occurred at high loads. For composite coatings, a relatively smooth surface was observed on the worn surface for all applied loads.

Wear Properties of Nuclear Graphite IG-110 at Elevated Temperature (원자력용 흑연 IG-110 에 대한 고온 마모 특성 평가)

  • Wei, Dunkun;Kim, Jaehoon;Kim, Yeonwook
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.38 no.5
    • /
    • pp.469-474
    • /
    • 2014
  • The high temperature gas-cooled reactor (HTR-10) is designed to produce electricity and hydrogen. Graphite is used as reflector, support structures, and a moderator in reactor core; it has good resistance to neutron and is a suitable material at high temperatures. Friction is generated in the graphite structures for the core reflector, support structures, and moderator because of vibration from the HTR-10 fuel cycle flow. In this study, the wear characteristics of the isotropic graphite IG-110 used in HTR-10 were evaluated. The reciprocating wear test was carried out for graphite against graphite. The effects of changes in the contact load and sliding speeds at room temperature and $400^{\circ}C$ on the coefficient of friction and specific wear rate were evaluated. The wear behavior of graphite IG-110 was evaluated based on the wear surfaces.

PFC Ultrasonic Decontamination Efficiency on the Various Types of Metal Specimens (금속 시편 형태에 따른 PEC 초음파 제염 성능)

  • Won Hui-Jun;Kim Gye-Nam;Jung Chung-Hun;Park Jin-Ho;Oh Won-Zin
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.3 no.4
    • /
    • pp.293-300
    • /
    • 2005
  • Ultrasonic decontamination of the type 304 stainless steel specimen loosely contaminated with $Eu_2O_3$ powders was investigated. Decontamination factors (DFs) by the three kinds of ultrasonic media such as water, pure PFC (Pefluorocarbon, $C_7F_{16}$) and a mixed solution of $99.9\;vol\%\;PFC\;and\;0.1\;vol\%$ anionic surfactant were determined. The determined DF values were 20, 50 and 200, respectively. This significant difference in the decontamination factors for the different decontamination solution was well explained by the surface tension of the media as well as the interaction between the positively charged surface of $Eu_2O_3$ powders and the anionic surfactant. Ultrasonic decontamination behavior of the loosely contaminated metal specimens such as plate, pipe, welding specimen and crevice specimen in the mixed solution of PFC and anionic surfactant was also investigated. The contaminants were completely removed for the tested specimens except for the longest specimen. For 6-cm long pipe specimen, however, $98.5\%$ of the contaminants were removed.

  • PDF

Prediction of the Dynamic Adsorption Behaviors of the Uranium and Cobalt Ions in a Fixed Bed by Surface Modified Activated Carbon (표면개질 활성탄을 이용한 고정층에서 우라늄 및 코발트 이온의 동적 흡착거동 모사)

  • Geun-IL Park;Jung-Won Lee;Kee-Chan Song;In-Tae Kim;Kwang-Wook Kim;Myung-Seung Yang
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.81-92
    • /
    • 2003
  • In order to predict the dynamic behaviors of uranium and cobalt in a fixed bed at various influent pH values of liquid waste, the adsorption system is regarded as a multi-component adsorption between each ionic species in the solution. Langmuir isotherm parameters of each species were extracted by incorporating equilibrium data with the solution chemistry of the uranium and cobalt using IAST. Prediction results were in good agreement with the experimental data, except for a high concentration and pH. Although there was some limitations in predicting the cobalt adsorption, this method may be useful in analyzing a complex adsorption system where various kinds of ionic species exist in a solution.

  • PDF

Comparative Evaluation of Various Standard Methods in Leaching Test of Radioactive Waste Form (방사성고화체로부터의 $^{60}$ Co, $^{137}$ Cs 침출에 대한 표준시험법의 상호비교)

  • Kim, Ki-Hong;Ryu, Young-Gerl;Chung, Kyung-Ki;Hong, Kwon-Pyo;Lee, Nak-Hee;Jeong, Yi-Yeong;Koh, Duck-Joon;Kim, Heon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.1 no.1
    • /
    • pp.93-103
    • /
    • 2003
  • IAEA, FT-04-020, and ANS 16.1, standard leaching test methods, were evaluated comparatively with their test results. Leaching index of $^{60}$ Co and $^{137}$ Cs by ANS 16.1 method for waste forms of paraffin and cement were above 6.0. Their leaching behavior were depending on the type of matrix and leachant. Leachability of $^{60}$ Co for cement waste form was higher in simulated seawater than do-mineralized water, and was higher in de-mineralized water for paraffin waste form. leachability of $^{60}$ Co was contrary to $^{137}$ Cs. Cumulative fraction leached of $^{60}$ Co was higher in order or IAEA > ANS > FT in a cement waste form.

  • PDF