• Title/Summary/Keyword: Fuel Utilization

Search Result 438, Processing Time 0.029 seconds

Power Factor Improvement of Distribution System with EV Chargers based on SMC Method for SVC

  • Farkoush, Saeid Gholami;Kim, Chang-Hwan;Jung, Ho-Chul;Lee, Sanghyuk;Theera-Umpon, Nipon;Rhee, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • v.12 no.4
    • /
    • pp.1340-1347
    • /
    • 2017
  • Utilization of Electric Vehicles (EVs) have been growing popularity in recent years due to increment in fuel price and lack of natural resources. Random unexpected charging by home EV charger in distribution is predicted in the future. The power quality problems such as fluctuation of power factor in a residential distribution network was explored with random EV chargers. This paper proposes a high-performance nonlinear sliding mode controller (SMC) for an EV charging system to compensate voltage distortions and to enhance the power factor against the unbalanced EV chargers. For the verification of the proposed scheme, MATLAB-Simulink simulations are performed on 22.9-kV grid. The results show that the proposed scheme can improve the power factor of a smart grid due to the EV chargers on the grid.

A Study on Thermodynamic Efficiency for HTSE Hydrogen and Synthesis Gas Production System using Nuclear Plant (원자력 이용 고체산화물 고온전기분해 수소 및 합성가스 생산시스템의 열역학적 효율 분석 연구)

  • Yoon, Duk-Joo;Koh, Jae-Hwa
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.5
    • /
    • pp.416-423
    • /
    • 2009
  • High-temperature steam electrolysis (HTSE) using solid oxide cell is a challenging method for highly efficient large-scale hydrogen production as a reversible process of solid oxide fuel cell (SOFC). The overall efficiency of the HTSE hydrogen and synthesis gas production system was analyzed thermo-electrochemically. A thermo-electrochemical model for the hydrogen and synthesis gas production system with solid oxide electrolysis cell (SOEC) and very high temperature gas-cooled reactor (VHTR) was established. Sensitivity analyses with regard to the system were performed to investigate the quantitative effects of key parameters on the overall efficiency of the production system. The overall efficiency with SOEC and VHTR was expected to reach a maximum of 58% for the hydrogen production system and to 62% for synthesis gas production system by improving electrical efficiency, steam utilization rate, waste heat recovery rate, electrolysis efficiency, and thermal efficiency. Therefore, overall efficiency of the synthesis production system has higher efficiency than that of the hydrogen production system.

Comparative Part Load Performance Analysis of Gas Turbine Power Generation Systems Considering Exhaust Heat Utilization (배열 이용도를 고려한 가스터빈 발전시스템의 부분부하 성능 비교분석)

  • Kim, T.S.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.6 no.3 s.20
    • /
    • pp.28-35
    • /
    • 2003
  • This paper presents analysis results for the effect of power control strategies on the part load performance of gas turbine based power generation systems utilizing exhaust heat of the gas turbine such as combined cycle power plants and regenerative gas turbines. For the combined cycle, part load efficiency variations were compared among different single shaft gas turbines representing various technology levels. Power control strategies considered were fuel only control and IGV control. It has been observed that gas turbines with higher design performances exhibit superior part load performances. Improvement of part load efficiency of the combined cycle by adopting air flow modulation was analyzed and it was concluded that since the average combined cycle performance is affected by the range of IGV control as well as its temperature control principle, a control strategy appropriate for the load characteristics of the individual plant should be adopted. For the regenerative gas turbine, it is likewise concluded that maintaining exhaust temperature as high as possible by air flow rate modulation is required to increase part load efficiency.

Development of Wireless Remote Monitoring System for Small Wind Turbine System (소형 풍력발전시스템을 위한 무선 원격 모니터링 시스템 개발)

  • Moon, Dae-Sun;Kim, Sung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.22 no.4
    • /
    • pp.460-467
    • /
    • 2012
  • Recently, concern over climate change and global politics associated with traditional fossil fuel energy sources has driven significant increase in wind energy utilization over the past decade. Especially, small wind turbine systems below 10kW are actively developed by several companies from all over the world. Generally, for the small wind turbine systems to be installed for commercial purposes, the performance of the system should be certified. For this, wireless remote monitoring system should be developed for efficient monitoring. In this work, a new type of wireless remote monitoring system based on Zigbee communication is proposed. Furthermore, practical experimentations are carried out to verify the feasibility of the proposed scheme.

Application of Micro Cross-Flow Turbine to Water Supply System (마이크로 관류수차의 상수도 관로시스템 적용에 관한 연구)

  • Choi Young-Do;Kurokawa Junichi
    • The KSFM Journal of Fluid Machinery
    • /
    • v.9 no.3 s.36
    • /
    • pp.36-43
    • /
    • 2006
  • Recently, micro hydropower and it's useful utilization are taking a growing interest as a countermeasure of global worming by carbon dioxide and exhaustion of fossil fuel. The purpose of this study is to investigate the possibility of extracting micro hydropower wasted by a valve in water supply system using micro cross-flow hydraulic turbine. In order to fulfill the functions of controlling flow rate and pressure in substitute for the valve, air and water are supplied into an air suction hole which is installed on the side wall of micro cross-flow hydraulic turbine. The results show that in case of supplying a lot of air into the air suction hole, about 50% of flow rate and relatively high value of loss coefficient are controlled by the turbine. Moreover, including high possibility of applying the micro cross-flow turbine to water supply system, extended application of the turbine to the water discharge system of drainage and irrigation canal.

Recent Instantiation Case of Lead Acid Battery for Energy Storage Systems (에너지 저장 시스템용 납 축전지의 최근 실증 사례)

  • An, Sang-Yong;Jung, Ho-Young
    • Applied Chemistry for Engineering
    • /
    • v.24 no.4
    • /
    • pp.344-349
    • /
    • 2013
  • Energy storage system is an energy reservoir which can store the electrical energy produced by the power plant into the chemical energy at the time whenever it needs to use. Accordingly, the energy storage system can help to improve the energy utilization efficiency and the stabilization of the power supply system. In addition, it can cope with the issues of carbon dioxide reduction and depletion of fossil fuel. Lead-acid battery in the secondary battery fields is one of the most developed technologies. It is also economical, reliable storage device. Therefore, the instantiation case of energy storage system using lead-acid battery was investigated for the reference studies.

DSM Resources Evaluation and Customer Behavior Analysis (DSM 자원평가 및 소비자 행태 분석)

  • Ahn, Nam-Seong;Park, Min-Hyuk;Rhu, Jae-Gook
    • Korean System Dynamics Review
    • /
    • v.5 no.1
    • /
    • pp.49-71
    • /
    • 2004
  • Demand-side Management can be defined as'any utility activity aimed at modifying customers' use of energy to produce desired changes in the utility's load shape'. Customers benefit by being able to control energy costs and improve quality of life and become more productive. Utilities benefit from DSM's value as a resource that enhances asset utilization and reduces both fuel costs and environmental emissions. The scope of DSM includes load management through rate schedules and conservation by improving energy effciency and using electricity consumption effectively. This paper study the DSM resource evaluation and customer behavior analysis todesign the DSM Program plan in response to customer needs. We develop basic system dynamics model to analysis the customer behavior based on a survey research. The DSM Program participants in the Hi- efficiency Inverter, Electric motor and efficient lighting applicancies operating by Conservation program 2002 become the survey objects. DSM resource evaluation evaluate firstt the distribution potentialities of each machine and then forecast the degree of diffusion. We apply the system dynamic approach to simulate the dynamic DSM market situation at the domestic beginning. This model will give the energy Planner the opportunity to create different scenarios for DSM program planning. Also it will lead to increased understanding of the dynamic DSM market

  • PDF

A study on the utilization of exhausted heat from subway for energy source of heat pump (공기열원 히트펌프의 에너지원으로서 지하철 배열 이용에 관한 연구)

  • Kim J.R.;Jeong K.C.
    • Journal of the Korean Institute of Gas
    • /
    • v.4 no.4 s.12
    • /
    • pp.13-19
    • /
    • 2000
  • Researches on unused energy are being continued because of the limited fossil fuel and the destruction of environment. Therefore this study was performed as follows The collectable amount of exhausted heat for an air-conditioning was calculated by the subway thermal environment prediction program. And the electric power needed by conventional heat source equipments was compared with one by unused heat source equipments when the exhausted heat was used by heat pump in heating and hot water supplying.

  • PDF

Mesquite (Prosopis juliflora) Pods as a Feed Resource for Livestock - A Review -

  • Sawal, R.K.;Ratan, Ram;Yadav, S.B.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.5
    • /
    • pp.719-725
    • /
    • 2004
  • Mesquite or Vilayati babul (Prosopis juliflora) is a drought resistant, evergreen, spiny tree with drooping branches and a deep laterally spreading root system. It grows in semi-arid and arid tracts of tropical and sub-tropical regions of the world and is spreading because the leaves are unpalatable and animals do not digest its seed. The mesquite has become a major nuisance; cutting or pruning its branches to form a canopy would provide shade for travelers, aid harvesting of pods, as well as make available wood for fuel. An average plant starts fruiting by 3-4 years of age and yields annually 10-50 kg pods/ tree, which can be collected from May-June and September-October. Availability of pods worldwide is estimated to be about 2-4 million metric tonnes. Ripe pods are highly palatable; on dry matter basis they contain 12% crude protein, 15% free sugar, a moderate level of digestible crude protein (7% DCP) with a high level of energy (75% TDN). The pods contain low tannin levels below those toxic to animals. Seeds contain 31-37% protein; pods should be finely ground before feeding to facilitate utilization of the seeds. Mesquite pods could replace costlier feed ingredients such as grain and bran contributing 10-50% of the diet. Phosphorus supplements need to be added when mesquite pod, exceeds 20% of animals' diet.

A Study of Bubble Pump that is applied Solar Heating Water System (태양열 온수 시스템에 적용한 기포펌프의 동작특성에 관한 연구)

  • Park, G.T.;Song, L.;Shim, K.J.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.32-37
    • /
    • 2007
  • Regarding the need of energy in advance and the depletion of fossil fuel energy, all researches around the world now are trying to extract energy from many alternative sources especially the renewable one. Solar, ocean tidal, wind and geothermal energy are renewable energy fields which many researches are focused on. This paper explains about effort to replace electric pump used in solar water heating system by bubble pump. The utilization of bubble pump in this system is very efficient since it needs heat energy for its operation that can be obtained easily. In addition, it can also simplify the construction of the system. Bubble pump also functions as a controller to circulate water inside the system. Before the installation of bubble pump, the special quality and performance of bubble pump should be analyzed. The result got from the analysis could show the fluctuation of water flow rate occurred because it sensitively reacts to the heat quantity. Here the heat quantity is taken from the solar that, as we know, is not stable in a whole day. Problems often occurred are the flow rate in this system is very low moreover it could be stop if the pressure exceeds the limit.

  • PDF