• Title/Summary/Keyword: Fuel Utilization

검색결과 433건 처리시간 0.025초

Generation Efficiency Characteristics of Small Wind Power for Green Energy Utilization (그린에너지 활용을 위한 소형풍력발전기의 효율 특성)

  • Lee, You-Seok;Kim, Jae-Yong
    • Applied Chemistry for Engineering
    • /
    • 제26권4호
    • /
    • pp.489-494
    • /
    • 2015
  • As the world-wide supply of fossil fuel sources decreases, the need for efficient energy conservation in addition to developing green energy technologies becomes critical. Wind energy is now regarded as one of the most rapidly expanding energy sources in the world. However, due to the high cost for the foundation of large turbines and the high wind speed (over 12 m/s) required, it is very difficult to establish inland wind power plants. In order to solve issues mentioned above, experiments were performed using the small wind power system operated in a low wind speed. In this research, inland wind condition was first analyzed, and 300 W and 1 kW small wind power generators were then installed on a roof and efficiencies of generating electricities were compared.

Comparative Part Load Performance Analysis of Gas Turbine Power Generation Systems Considering Exhaust Heat Utilization (배열 이용도를 고려한 가스터빈 발전시스템의 부분부하 성능 비교분석)

  • Kim, T. S.
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2002년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.290-297
    • /
    • 2002
  • This paper presents analysis results for the effect of power control strategies on the part load performance of gas turbine based power generation systems utilizing exhaust heat of the gas turbine such as cumbined cycle power plants and regenerative gas turbines. For the combined cycle, part load efficiency variations were compared among different single shaft gas turbines representing various technology levels. Power control strategies considered were fuel only control and IGV control. It has been observed that gas turbines with higher design performances exhibit superior part load performances. Improvement of part load efficiency by adopting air flow modulation was analyzed and it is concluded that since the average combined cycle performance is affected by the range of IGV control as well as its temperature control principle, a control strategy appropriate for the load characteristics of the individual plant should be adopted. For the regenerative gas turbine, it is likewise concluded that maintaining exhaust temperature as high as possible by air flow rate modulation is required to increase part load efficiency.

  • PDF

A Study on the Burning Velocity Correlation of LFG Mixed Fuel Using Numerical Analysis (수치계산을 이용한 LFG 혼합연료의 연소속도 상관식에 관한 연구)

  • Lee, Chang-Eon;O, Chang-Bo;Jeong, Ik-San
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • 제24권11호
    • /
    • pp.1513-1522
    • /
    • 2000
  • In this study, the burning velocities of LFG and LFG mixed fuels have been numerically determined. C3 reaction mechanism involving 92 species and 621 reactions was adopted in the calculation. The computed burning velocities using C3 mechanism show good agreements with experimental data. Based on numerical results, the maximum burning velocities of LFG and LFG mixed fuels were correlated as a function of CH$_4$ and LFG component percentage at stoichiometric conditions. In addition, the correlations of burning velocities of LFG and LFG mixed fuels were obtained over a wide range of the equivalence ratio. The numerical results are well agreed with the burning velocity correlations. The burning velocity correlations for LFG and LFG mixed fuels suggested in this study can be applied to the practical utilization of LFG.

Biogas-Microturbine Distributed Generation Developement at Gong-Ju Public Livestock Wastewater Treatment Facility (공주 축산폐수공공처리장에서의 바이오가스-마이크로터빈 분산발전시스템 개발)

  • Park, Jung-Keuk;Hur, Kwang-Beom;Lee, Ki-Chul;Kang, Ho;Rhim, Sang-Gyu
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2008년도 춘계학술대회 논문집
    • /
    • pp.229-234
    • /
    • 2008
  • Korea Electric Power Corporation (KEPCO) has started the nation's first biogas-microturbine project in the city of Gongju as an effort to encourage the utilization of wasted biogas containing useful energy source in the form of $CH_4$. The goal of the project is to set up the biogas microturbine co-generation system for utilizing biogas as an energy source and improving the economics of the wastewater treatment plant. Wastewater treatment processes were investigated in depth to find improvement possibility. Changes in internal recirculation ratio and pre-treatment degree are needed to optimize plant operation and biogas production. Biogas pre-treatment system satisfies Capstone's fuel condition requirement with the test result of 99.9% and 90.2% of hydrogen sulphide and ammonia is removal performance. Installation of microturbine and manufacture of heat exchanger to warm anaerobic digester has been done successfully. Expected economic profit produced by the system is coming from energy saving including electricity 115,871kWh/year and heat contained in exhaust gas 579GJ/year.

  • PDF

Soft-Switching PWM Boost Chopper-Fed DC-DC Power Converter with Load Side Auxiliary Passive Resonant Snubber

  • Nakamura, Mantaro;Ogura, Koki;Nakaoka, Mutsuo
    • Journal of Power Electronics
    • /
    • 제4권3호
    • /
    • pp.161-168
    • /
    • 2004
  • This paper presents a new circuit topology of high-frequency soft switching commutation boost type PWM chopper-fed DC-DC power converter with a loadside auxiliary passive resonant snubber. In the proposed boost type chopper-fed DC-DC power converter circuit operating under a principle of ZCS turn-on and ZVS turn-off commutation, the capacitor and inductor in the auxiliary passive resonant circuit works as the lossless resonant snubber. In addition to this, the voltage and current peak stresses of the power semiconductor devices as well as their di/dt or dv/dt dynamic stress can be effectively reduced by the single passive resonant snubber treated here. Moreover, it is proved that chopper-fed DC-DC power converter circuit topology with an auxiliary passive resonant snubber could solve some problems on the conventional boost type hard switching PWM chopper-fed DC-DC power converter. The simulation results of this converter are illustrated and discussed as compared with the experimental ones. The feasible effectiveness of this soft witching DC-DC power converter with a single passive resonant snubber is verified by the 5kW, 20kHz experimental breadboard set up to be built and tested for new energy utilization such as solar photovoltaic generators and fuel sell generators.

Compost Production using Vegetable Waste and Spent Oak Mushroom Substrate (SMS) (채소 부산물과 표고 수확후 배지를 활용한 퇴비 제조방법)

  • Kim, Eui-Yeong;Kook, Seung-Woo;Yuk, Hwa Jung;Yoon, Min Ho;Kim, Sung-Chul
    • Journal of Mushroom
    • /
    • 제14권4호
    • /
    • pp.237-243
    • /
    • 2016
  • Spent mushroom substrate (SMS) has generally been used for the manufacture of animal feed and production of bio fuel. Limited research has been conducted in the utilization of SMS as a co-material for composting. Therefore, the main purpose of this study was to evaluate the feasibility of composting vegetable waste mixed with various ratios of SMS (30, 40, and 50%). The results showed that the C/N ratio decreased when both sawdust (from 22.0~28.8 to 17.7~20.4) and SMS (from 18.5~19.5 to 12.7~16.8) were applied for composing, owing to increased contents of nitrogen. A maturity test conducted using mechanical (Solvita) and germination tests revealed that both sawdust (92.0~101.9%) and SMS (87.8~89.2%) satisfied a criteria of maturity standard (70%). A correlation analysis between compost maturity and its chemical properties revealed that the C/N ratio and pH were the most dominant parameters for compost maturity. Overall, SMS could be utilized as a compost material and especially, vegetable waste mixed with SMS could provide sufficient nutrients for crop growth.

Power Factor Improvement of Distribution System with EV Chargers based on SMC Method for SVC

  • Farkoush, Saeid Gholami;Kim, Chang-Hwan;Jung, Ho-Chul;Lee, Sanghyuk;Theera-Umpon, Nipon;Rhee, Sang-Bong
    • Journal of Electrical Engineering and Technology
    • /
    • 제12권4호
    • /
    • pp.1340-1347
    • /
    • 2017
  • Utilization of Electric Vehicles (EVs) have been growing popularity in recent years due to increment in fuel price and lack of natural resources. Random unexpected charging by home EV charger in distribution is predicted in the future. The power quality problems such as fluctuation of power factor in a residential distribution network was explored with random EV chargers. This paper proposes a high-performance nonlinear sliding mode controller (SMC) for an EV charging system to compensate voltage distortions and to enhance the power factor against the unbalanced EV chargers. For the verification of the proposed scheme, MATLAB-Simulink simulations are performed on 22.9-kV grid. The results show that the proposed scheme can improve the power factor of a smart grid due to the EV chargers on the grid.

A Study on Thermodynamic Efficiency for HTSE Hydrogen and Synthesis Gas Production System using Nuclear Plant (원자력 이용 고체산화물 고온전기분해 수소 및 합성가스 생산시스템의 열역학적 효율 분석 연구)

  • Yoon, Duk-Joo;Koh, Jae-Hwa
    • Transactions of the Korean hydrogen and new energy society
    • /
    • 제20권5호
    • /
    • pp.416-423
    • /
    • 2009
  • High-temperature steam electrolysis (HTSE) using solid oxide cell is a challenging method for highly efficient large-scale hydrogen production as a reversible process of solid oxide fuel cell (SOFC). The overall efficiency of the HTSE hydrogen and synthesis gas production system was analyzed thermo-electrochemically. A thermo-electrochemical model for the hydrogen and synthesis gas production system with solid oxide electrolysis cell (SOEC) and very high temperature gas-cooled reactor (VHTR) was established. Sensitivity analyses with regard to the system were performed to investigate the quantitative effects of key parameters on the overall efficiency of the production system. The overall efficiency with SOEC and VHTR was expected to reach a maximum of 58% for the hydrogen production system and to 62% for synthesis gas production system by improving electrical efficiency, steam utilization rate, waste heat recovery rate, electrolysis efficiency, and thermal efficiency. Therefore, overall efficiency of the synthesis production system has higher efficiency than that of the hydrogen production system.

Comparative Part Load Performance Analysis of Gas Turbine Power Generation Systems Considering Exhaust Heat Utilization (배열 이용도를 고려한 가스터빈 발전시스템의 부분부하 성능 비교분석)

  • Kim, T.S.
    • The KSFM Journal of Fluid Machinery
    • /
    • 제6권3호
    • /
    • pp.28-35
    • /
    • 2003
  • This paper presents analysis results for the effect of power control strategies on the part load performance of gas turbine based power generation systems utilizing exhaust heat of the gas turbine such as combined cycle power plants and regenerative gas turbines. For the combined cycle, part load efficiency variations were compared among different single shaft gas turbines representing various technology levels. Power control strategies considered were fuel only control and IGV control. It has been observed that gas turbines with higher design performances exhibit superior part load performances. Improvement of part load efficiency of the combined cycle by adopting air flow modulation was analyzed and it was concluded that since the average combined cycle performance is affected by the range of IGV control as well as its temperature control principle, a control strategy appropriate for the load characteristics of the individual plant should be adopted. For the regenerative gas turbine, it is likewise concluded that maintaining exhaust temperature as high as possible by air flow rate modulation is required to increase part load efficiency.

Development of Wireless Remote Monitoring System for Small Wind Turbine System (소형 풍력발전시스템을 위한 무선 원격 모니터링 시스템 개발)

  • Moon, Dae-Sun;Kim, Sung-Ho
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • 제22권4호
    • /
    • pp.460-467
    • /
    • 2012
  • Recently, concern over climate change and global politics associated with traditional fossil fuel energy sources has driven significant increase in wind energy utilization over the past decade. Especially, small wind turbine systems below 10kW are actively developed by several companies from all over the world. Generally, for the small wind turbine systems to be installed for commercial purposes, the performance of the system should be certified. For this, wireless remote monitoring system should be developed for efficient monitoring. In this work, a new type of wireless remote monitoring system based on Zigbee communication is proposed. Furthermore, practical experimentations are carried out to verify the feasibility of the proposed scheme.