• Title/Summary/Keyword: Fuel Cell Dynamics

Search Result 131, Processing Time 0.019 seconds

Study on system dynamic behaviors for 4kW-class fuel cell hybrid vehicle (4kW급 연료전지 하이브리드 자동차 개발을 위한 시스템 동특성 연구)

  • Lee, Dong-Ryul;Park, Kwang-Jin;Bae, Joong-Myeon;Jeong, Jae-Haw;Ji, Hyun-Jin
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.11a
    • /
    • pp.93-96
    • /
    • 2006
  • PEMFC(proton exchange membrane fuel cell) is most applicable to automobile in various types of fuel cell. However, to improve system dynamics and logn term Performance fuel cell is supported by auxiliary power unit forming hybrid system. The operating strategy of hybrid system influences on efficiency and stability. In this paper the proper strategies are compared each other considering power distribution and stable system operation. The chosen strategy is simulated by MATLAB simulink to forecast realization of fuel cell hybrid vehicle

  • PDF

Modeling of BLDC Motor Driving System for Platform Screen Door Control applied Fuel Cell Power Generation System (연료전지 발전시스템을 이용한 승강장 스크린 도어 제어용 BLDC 전동기 구동 모델링)

  • Yoon, Yong-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.6
    • /
    • pp.968-974
    • /
    • 2017
  • In this paper, modeling of brushless DC motor (BLDC) driving system for platform screen door control applied fuel cell power generation system has been proposed. At first the system configuration and operational principle of the developed fuel cell simulator has been investigated and the design of BLDC motor driving system is studied and the overall performance and dynamics of the proposed system could be effectively examined by simulation. PSIM simulation program is implemented to verify the performance and compatibility of the fuel cell power generation system and BLDC motor control system modeling.

CFD-based Flow Simulation Study of Fuel Cell Protective Gas (CFD를 활용한 연료전지 모듈 보호가스 유동 연구)

  • Kwon, Kiwook;Lim, Jongkoo;Park, Jongcheol;Shin, Hyun Khil
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.86.1-86.1
    • /
    • 2011
  • To improve the safety, the fuel cell operate inside a pressurized enclosure which contains inert gas so called protective gas. The protective gas not only prevents the mixture of hydrogen and oxygen, but also removes the water in the vessel with the condenser. This study presents the details of the flow optimization in order to reduce the humidity in the fuel cell housing. The protective gas flow in the fuel cell container is studied by Computational Fluid Dynamics(CFD) simulations. This study focuses on optimizing the geometry of an protective gas circulation system in fuel cell module to reduce the humidity in the vessel. CFD analysis was carried out for an existing model to understand the flow behavior through the fuel cell system. Based on existing model CFD results, geometrical changes like inlet placement, optimization of outlet size, modification of fuel cell module system are carried out, to improve the flow characteristics. The CFD analysis of the optimized model is again carried out and the results show good improvement in protective gas flow behavior.

  • PDF

Optimal Design of Bipolar-Plates for a PEM Fuel Cell (고분자 전해질 연료전지용 분리판 최적 설계)

  • Han, In-Su;Jeong, Jee-Hoon;Lim, Jong-Koo;Lim, Chan;Jung, Kwang-Sup
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2006.06a
    • /
    • pp.99-102
    • /
    • 2006
  • Optimal flow-field design of bipolar-plates for a commercial class PEM(polymer electrolyte membrane) fuel cell stack was carried out on the basis of three-dimensional computational fluid dynamics(CFD) simulation. A three-dimensional CFD model originally developed by Shimpalee et al., has been utilized for performing large-scale simulation of a single fuel cell consisting of bipolar-plates gas diffusion layers, and a membrane-electrode-assembly(MEA). The CFD model is able to predict the current density, pressure drops, gas velocities, vapor and liquid water contents, temperature distributions, etc. inside a single fuel cell. Depending on simulation results from the CFD modeling of a PEM fuel cell, several flow-fields of bipolar-plates were designed and verified. The final design of the bipolar-plate has been chosen from the simulations and experimental tests and showed the best performance as expected from the simulation results under a normal operating condition. Thus, the CFD simulation approach to design the optimal flow-field of the bipolar-plates was successful. The final design was adopted as the best flow-field to build a commercial scale PEM fuel cell stack, the performance of which shows about 42% higher than that of the older bipolar-plate design.

  • PDF

A Study on Oxygen Diffusion Characteristics According to Changes in Flow Field Shape of Polymer Electrolyte Membrane Fuel Cell Metallic Bipolar Plate for Building (건물용 고분자 전해질 연료전지 금속분리판 유동장 형상 변화에 따른 산소 확산 특성에 대한 연구)

  • PARK, DONGHWAN;SOHN, YOUNG-JUN;CHOI, YOON-YOUNG;KIM, MINJIN;HONG, JONGSUP
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.32 no.4
    • /
    • pp.245-255
    • /
    • 2021
  • Various studies about metallic bipolar plates have been conducted to improve fuel cell performance through flow field design optimization. These research works have been mainly focused on fuel cells for vehicle, but not fuel cells for building. In order to reduce the price and volume of fuel cell stacks for building, it is necessary to apply a metallic flow field, In this study, for a metallic flow field applied to a fuel cell for building, the effect of a change in the flow field shape on the performance of a polymer electrolyte membrane fuel cell was confirmed using a model and experiments with a down-sizing single cell. As a result, the flow field using a metal foam outperforms the channel type flow field because it has higher internal differential pressure and higher reactants velocity in gas diffusion layer, resulting in higher water removal and higher oxygen concentration in the catalyst layer than the channel type flow field. This study is expected to contribute to providing basic data for selecting the optimal flow field for the full stack of polymer electrolyte membrane fuel cells for buildings.

The Modeling of Power System with PEM fuel cell (연료전지 전력 시스템의 모델링)

  • Han, K.H.;Lee, H.J.;Lee, N.Y.;Jang, H.Y.;Lee, B.Y.;Baek, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 2008.04c
    • /
    • pp.239-241
    • /
    • 2008
  • A powered system with fuel cell is regarded as a high current and low voltage source. Effects of the loads on the electrical power source are important to optimize the integrated power system. The design parameters of the system should be chosen by taking into account the characteristics of the fuel cell, so the costs of the power system at given operating conditions can be reduced. Furthermore, the dynamics characteristic of the system is crucial to acquire performance in applications, particularly interactions between loads and the fuel cell system. Currently, no integrated simulation has been approached to analyze interrelated effects. Therefore, the dynamic models of power conversion system with a PEM fuel cell that includes the PEM fuel cell stack, DC/DC converter and associated controls is developed. Electric lads for the system are derived by using a power theory that separates a load current into active, reactive, distortion or a mixed current component. Dependency of the DC capacitor on the loads are analyzed.

  • PDF

Numerical and Experimental Analysis of Pressure Drop in a Bipolar Plate channel of a Proton Exchange Membrane Fuel Cell (연료전지 분리판 압력손실 감소를 위한 수치해석 및 실험적 연구)

  • Kim, Hee-Su;Kang, Kyung-Tae;Choi, Yun-Ki;Lee, Su-Dong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.15 no.2
    • /
    • pp.159-165
    • /
    • 2004
  • Fuel cell makes electricity through chemical reaction. Bipolar-plate distribute hydrogen, oxidation using channel geometry condensation of water vapor inside channels of bipolar-plates lowers efficiency of fuel cell. Usually high pressured gas supply is used to solve the water condensation problem with serpentine type channel geometry. In this study, a new channel geometry shows feasible to minimize lowering efficiency due to water condensation through numerical and experimental analysis.

Topology of High Efficiency Power Conversion with Fuel Cell Generation System (고효율 전력변환장치를 사용한 연료전지 시스템의 토폴로지)

  • Mun, S.P.;Suh, K.Y.;Lee, H.W.;Kwon, S.K.;Nakaoko, M.;Shin, H.B.
    • Proceedings of the KIEE Conference
    • /
    • 2005.10c
    • /
    • pp.329-333
    • /
    • 2005
  • In this study paper, a 3[kW] Fuel Cell Generation (FCG)system with Fuel Cell(FC)simulator has been proposed. The developed FC simulator generates the actual voltage and current output characteristics of the Proton Exchange Membrane Fuel Cell (PEMFC), so that the overall performance and the dynamics of the proposed system could be effectively examined and tested. In this paper, at first, the system configuration and operational principle of the developed FC simulator has been investigated and the design process of the FCG system is explained in detail. In addition, the validity of the proposed system has been verified by the informative simulation and experimental results.

  • PDF

Comparison between CFD analysis and experiments according to various PEMFC flow-field designs (유로 형상 변화에 따른 CFD 해석 결과와 PEM 연료전지 성능 비교)

  • Lee, Kang-In;Park, Min-Soo;Lee, Se-Won;Chu, Chong-Nam
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2008.05a
    • /
    • pp.572-575
    • /
    • 2008
  • Flow-field design has much influence over the performance of proton exchange membrane fuel cell (PEMFC) because it affects the pressure magnitude and distribution of the reactant gases. To obtain the pressure magnitude and distribution of reactant gases in four kinds of flow-field designs without additional measurement equipment, computational fluid dynamics (CFD) analysis was performed. After the CFD analysis, the performance values of PEMFC according to the flow-field configurations were measured via a single cell test. As expected, the pressure differences due to different flow-field configurations were related to the PEMFC performance because the actual performance results showed the same tendency as the results of the CFD analysis. A large pressure drop resulted in high PEMFC performance. So, the single serpentine configuration gave the highest performance. On the other hand, the parallel flow-field configuration gave the lowest performance because the pressure difference between inlet and outlet was the lowest.

  • PDF

Dynamic Modeling of Cooling System Thermal Management for Automotive PEMFC Application (자동차용 연료전지 냉각계통 열관리 동적 모사)

  • Han, Jae Young;Lee, Kang Hun;Yu, Sang Seok
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.36 no.12
    • /
    • pp.1185-1192
    • /
    • 2012
  • The typical operating temperature of an automotive fuel cell is lower than that of an internal combustion engine, which necessitates a refined strategy for thermal management. In particular, the performance of the cooling module has to be higher for a fuel cell system because the temperature difference between the fuel cell and the surrounding is lower than in the case of the internal combustion engine. Even though the cooling system of an automotive fuel cell determines the operating temperature and temperature distribution of the fuel cell, it has attracted little research attention. This study presents the mathematical model of a cooling system for an automotive fuel cell system using Matlab/$Simulink^{(R)}$. In particular, a radiator model is developed for design optimization from the development stage to the operating stage for an automotive fuel cell. The cooling system model comprises a fan, pump, and radiator. The pump and fan model have an empirical relation, and the dynamics of the pump and fan are only explained by motor dynamics. The basic design study was conducted, and the geometric setup of the radiator was investigated. When the control logic was applied, the pump senses the coolant inlet temperature and the fan senses the coolant out temperature. Additionally, the cooling module is integrated with the fuel cell system model so that the performance of the cooling module can be investigated under realistic operating conditions.