• Title/Summary/Keyword: Fuel Cell, Hybrid Energy System

Search Result 130, Processing Time 0.026 seconds

The study of proton exchange membrane fuel cell and Li-poly battery hybrid system (로봇용 연료전지 이차전지 하이브리드 시스템 연구)

  • Kwon, O-Sung;Lee, Sang-Cheol;Lee, Sang-Woo;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.spc3
    • /
    • pp.282-288
    • /
    • 2012
  • Proton exchange membrane fuel cell (PEMFC) is the most promising energy source for the robot applications because it has unique advantages such as high energy density, no power drop during operating, and easy to make compact size. However, PEMFC has intrinsic disadvantages which are delay to start up and difficulty to correspond drastic load changes. These disadvantages can be compensated by hybrid operating with a Li-poly battery. This study is focus to build and understand the hybrid system for the robot system. In this study, we build the PEMFC hybrid system using EOS-320 PEMFC stack, Li-poly battery and G-Philos FDX1-250BU dc-dc converter. The hybrid system is accurately monitored by CAN and RS485. The system was studied under two conditions such as non-loaded and loaded operating conditions. The results show that the system has delay to start up without hybrid operating and it can be compensated with the hybrid operating.

Optimization of Residential Photovoltaic-Fuel Cell Hybrid System Using HOMER(R) (HOMER를 이용한 가정용 태양광-연료전지 하이브리드시스템의 운전 최적화)

  • Park, Se-Joon;Li, Ying;Choi, Young-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.1
    • /
    • pp.129-133
    • /
    • 2010
  • A hybrid system which is combined several complementary new and renewable power sources, such as photovoltaic, fuel-cell, and wind generator, etc., has been presented in various approaches. For instance, a photovoltaic cannot always generate stable output power with ever-changing weather condition, so it might be co-generated with a wind generator, diesel generator, and some other sources. In this paper, a residential PV-FC hybrid system is suggested as a distribution power source, and its operation is optimized by HOMER$^{(R)}$. As a result, it is the most economic that 5[kW] PV, 1[kW] FC, 4 batteries, 2[kW] electrolyzer, 0.5[kg] $H_2$ tank, 3[kW] converter are applied to the hybrid system.

IEA ECBCS Annex 54 Economic Assessment Study of a Fuel Cell Integrated Ground Source Heat Pump Microgeneration System (연료전지 지열히트펌프 마이크로제너레이션 IEA ECBCS Annex 54 경제성 평가 연구)

  • Na, Sun-Ik;Kang, Eun-Chul;Lee, Euy-Joon
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.26 no.5
    • /
    • pp.199-205
    • /
    • 2014
  • The integration of FC (Fuel Cell) and GSHP (Ground Source Heat Pump) hybrid system could produce a synergistic advantage in thermal and electric way. This study intends to analyse the economical aspect of a FC integrated GSHP hybrid system compared to the conventional system which is consisted with a boiler and a chiller. Based on the hourly simulation, the study indicated that GSHP system and FC+GSHP hybrid system could reduce the energy consumption on a building. The method of the economic assessment has been based on IEA ECBCS Annex 54 Subtask C SPB(Simple Payback) method. The SPB was calculated using the economic balanced year of the alternative system over the conventional (reference) system. The SPB of the alternative systems (GSHP and FC+GSHP) with 50% initial incentive was 4.06 and 26.73 year respectively while the SPB without initial incentive of systems was 10.71 and 57.76 year.

A Study for Correlativity of Hydrogen Production Using Artificial Luminous Intensity (인공조도를 이용한 수소발생량과의 상관성에 관한 연구)

  • Jung, You-Ra;Hong, Chang-Woo;Choi, Young-Sung;Lee, Kyung-Sup
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.218-221
    • /
    • 2010
  • This paper presents energy efficiency about an electrolyser which is related with the hybrid system of solar cell and fuel cell for using the system more fully. The water electrolyser is the exact reverse of a hydrogen fuel cell; it produces gaseous hydrogen and oxygen from water. Electrolyser technology may be implemented at a variety of scales wherever there is an electricity supply to provide hydrogen and/or oxygen for virtually any requirement. Also, this paper shows optimum operating point in the electrolyser for saving cost of the electrical energy with hybrid system.

Power System Development of Unmanned Aerial Vehicle using Proton Exchange Membrane Fuel Cell (고분자 전해질 연료전지를 이용한 무인비행체 동력시스템 설계)

  • Jee, Yeong-Kwang;Sohn, Young-Jun;Park, Gu-Gon;Kim, Chang-Soo;Choi, Yu-Song;Cho, Sung-Baek
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.23 no.3
    • /
    • pp.250-255
    • /
    • 2012
  • In this paper, the development and performance analysis of a fuel cell-powered unmanned aerial vehicle is described. A fuel cell system featuring 1 kW proton exchange membrane fuel cell combined with a highly pressurized fuel supply system is proposed. For the higher fuel consumption efficiency and simplification of overall system, dead-end type operation is chosen and each individual system such as purge system, fuel supply system, cooling system is developed. Considering that fluctuation of exterior load makes it hard to stabilize fuel cell performance, the power management system is designed using a fuel cell and lithium-ion battery hybrid system. After integration of individual system, the performance of unmanned aerial vehicle is analyzed using data from flight and laboratory test. In the result, overall system was properly operated but for more duration of flight, research on weight lighting and improvement of fuel efficiency is needed to be progressed.

Performance Prediction and Economic Assessment of Atmospheric Pressure MCFC/Gas Turbine Hybrid System with Indirect Turbine Firing (터빈 간접가열식 상압형 MCFC/가스터빈 복합시스템의 성능예측과 경제성 평가)

  • Choi, Joo Hwan;Kim, Tong Seop;Kwak, Bu Ho
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.38 no.1
    • /
    • pp.31-39
    • /
    • 2014
  • The performance of fuel cell/gas turbine hybrid systems is highly affected by system configuration. In this study, the performance of a hybrid system combining a molten carbonate fuel cell (MCFC) and an indirectly fired gas turbine was predicted. Firstly, general performance trends of the hybrid system depending on major design parameters were examined. Then, the most feasible design options with the least impact on the MCFC stack design conditions were drawn. The economic advantage of the hybrid system over the basic MCFC only system was evaluated.

A Simulation based Study on the Economical Operating Strategies for a Residential Fuel Cell System (시뮬레이션 기반 가정용 연료전지 시스템의 경제적 운전전략에 관한 연구)

  • Hwang, Su-Young;Kim, Min-Jin;Lee, Jin-Ho;Lee, Won-Yong
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.20 no.2
    • /
    • pp.104-115
    • /
    • 2009
  • In case of residential fuel cell system, it is significant to stably supply heat and power to a house with high efficiency and low cost for the successful commercialization. In this paper, the control strategy analysis has been performed to minimize the total cost including capital and operating cost of the residential fuel cell system. The proposed analysis methodology is based on the simulator including the efficiency models as well as the cost data for fuel cell components. The load control strategy is the key factor to decide the system efficiency and thus the cost analysis is performed when the fuel cell system is operated for several different load control logics. Additionally, annual efficiency of the system based on the seasonal load data is calculated since system efficiency is changeable according to the electric and heat demand change. As a result, the hybrid load control combined electricity oriented control and heat oriented control has the most economical operation.

Design of Hybrid System for Battery Charge·Discharge using Photovoltaic/Fuel cell (태양광/연료전지용 배터리 충·방전 하이브리드 시스템 설계)

  • Park, Bong-Hee;Jo, Yeong-Min;Choi, Ju-Yeop;Cho, Sang-Yoon;Choy, Ick;Lee, Dong-Ha
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.4
    • /
    • pp.123-129
    • /
    • 2014
  • Photovoltaic and fuel cell systems can be used as power source in mobile robots. At this time the photovoltaic system generally generate power in daytime. The starting time of fuel cell is slower than the lithium battery. To compensate for these disadvantages, a battery charge-discharge system is used. Especially the bi-directional converter is used mainly in the charge-discharge method. The controller in a buck converter controls the input voltage of the converter to meet the maximum power point tracking(MPPT) performance. First of all, the simulations of hybrid system for battery charge-discharge system in each step simulated using solar and fuel cell modeling as input source in PSIM. Experiment of the buck and bi-directional converter system is conducted through using photovoltaic/fuel cel simulator(pCube) instead of solar and fuel cell. This hybrid system for battery charge discharge using photovoltaic/fuel cell generates emergency power for the communication system in mobile robot.

Power control strategies of a DC-coupled hybrid power system for a building microgrid

  • Cho, Jea-Hoon;Hong, Won-Pyo
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.3
    • /
    • pp.50-64
    • /
    • 2011
  • In this paper, a DC-coupled photovoltaic (PV), fuel cell (FC) and ultracapacitor hybrid power system is studied for building microgrid. In this proposed system, the PV system provides electric energy to the electrolyzer to produce hydrogen for future use and transfer to the load side, if possible. Whenever the PV system cannot completely meet load demands, the FC system provides power to meet the remaining load. The main weak point of the FC system is slow dynamics, because the power slope is limited to prevent fuel starvation problems, improve performance and increase lifetime. A power management and control algorithm is proposed for the hybrid power system by taking into account the characteristics of each power source. The main works of this paper are hybridization of alternate energy sources with FC systems using long and short storage strategies to build an autonomous system with pragmatic design, and a dynamic model proposed for a PV/FC/UC bank hybrid power generation system. A simulation model for the hybrid power system has been developed using Matlab/Simulink, SimPowerSystems and Matlab/Stateflow. The system performance under the different scenarios has been verified by carrying out simulation studies using a practical load demand profile, hybrid power management and control, and real weather data.

The study of proton exchange membrane fuel cell and Li-poly battery hybrid system (로봇용 연료전지 이차전지 하이브리드 시스템 개발)

  • Kwon, O-Sung;Lee, Sang-Cheol;Lee, Sang-Woo;Lee, Dong-Ha
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2012.03a
    • /
    • pp.229-233
    • /
    • 2012
  • Proton exchange membrane fuel cell (PEMFC) is the most promising energy source for the robot applications because it has unique advantages such as high energy density, no power drop during operating, and easy to make compact size. However, PEMFC has intrinsic disadvantages which are delay to start up and difficulty to correspond drastic load changes. These disadvantages can be compensated by hybrid operating with a Li-poly battery. This study is focus to build and understand the hybrid system for the robot system. In this study, we build the PEMFC hybrid system using EOS-320 PEMFC stack, Li-poly battery and G-Philos FDX1-250BU dc-dc converter. The hybrid system is accurately monitored by CAN and RS485. The system was studied under two conditions such as non-loaded and loaded operating conditions. The results show that the system has delay to start up without hybrid operating and it can be compensated with the hybrid operating.

  • PDF