• Title/Summary/Keyword: Frozen-thawing

Search Result 412, Processing Time 0.031 seconds

A Study on the effect of bread quality by thawing temperature of frozen dough (냉동생지의 해동온도가 품질에 미치는 영향에 관한 연구)

  • Lee, Jeong-Hoon;Kim, Hyun-Whae
    • Culinary science and hospitality research
    • /
    • v.7 no.1
    • /
    • pp.91-105
    • /
    • 2001
  • Chou-cream bread and Red bean paste bread were made by sponge & dough method with the sweet dough formula. The bread quality was studied by the measurements of the temperature variation, the fermentation level of frozen dough in the special condition(dough conditioner of 5$^{\circ}C$, 10$^{\circ}C$, 15$^{\circ}C$, 20$^{\circ}C$ and 30$^{\circ}C$), the product volume and thesensory evaluation with frozen dough thawed, fermented and baked. When thawing temperature was low, the core temperature of frozen dough increased slowly and the time for thawing and fermentationwas long. In thawing and fermentation, the core temperature of Red bean paste dough increased faster than that of Chou-cream dough. When the thawing conditions of dough conditioner(retarder) were 20$^{\circ}C$ and 30$^{\circ}C$, the level of total time decrease for thawing and fermentation was 55 and 86 min in Chou-cream dough and 62 and 90 min in Red bean paste dough respectively in comparison to dough conditioner of 5$^{\circ}C$. In volume of baked products, they showed no significant difference for three weeks of storage, but slight difference for four weeks of storage. The result was that Chou-cream bread was larger than Red bean paste bread in the decrease of volume. In sensory evaluation, the bread quality became low according to the time. When stored for four weeks in the freezer, significant differences were found in Chou-cream vread, but slight difference appeared in Red bean paste bread. The research identified that Red bean paste dough was more effective in manufacturing time than that of Chou-cream dough, when thawing temperature was high, and if frozen dough was thawed in the retarder of lower than 20$^{\circ}C$, the bread quality in terms of volume and sensory evaluation had no significant difference in comparison to the none-freezing Red bean paste bread.

  • PDF

Rheological Properties of Calrose Rice and Effect of Thawing Methods on Quality Characteristics of Frozen Turmeric Rice (칼로스 쌀의 유변학적 특성과 이로 제조된 냉동 강황밥의 해동방법에 따른 품질특성 변화)

  • Kim, So Yeon;Choi, Yu Ra;Kim, Kyeong Seop;Lee, Sang Jun;Chang, Yoon Hyuk
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.6
    • /
    • pp.771-777
    • /
    • 2017
  • This study investigated the rheological properties of Calrose rice flour dispersions as well as the effects of different thawing methods (steamer, smart oven, and microwave oven) on quality characteristics of frozen turmeric rice. Apparent viscosity, consistency index, and yield stress significantly increased at higher rice flour concentrations. Magnitudes of storage modulus and loss modulus significantly increased with elevation of rice flour concentration. Frozen turmeric rice thawed using a steamer had the highest moisture content and largest size (length, width, and thickness) among all thawing methods. The L values of turmeric rice after thawing using a steamer was significantly higher than those of other thawing methods. The a value of turmeric rice after thawing using a steamer was significantly lower than those of other thawing methods. Textural properties (hardness, adhesiveness, springiness, cohesiveness, brittleness, and chewiness) of frozen turmeric rice after thawing using a steamer were significantly lower than those of other thawing methods. Therefore, it can be concluded that frozen turmeric rice after thawing using a steamer might be desirable for improvement of texture.

Assessment of Utilization and Storage Management Practice of Frozen and Refrigerated Foods in School Foodservice -Focus on Meats, Seafoods and Processed Foods- (학교급식에서의 냉장.냉동 축.수산물 및 가공품 이용현황 및 관리실태 조사)

  • Jeong, Hui-Seon;Yun, Ji-Yeong;Bae, Hyeon-Ju
    • Journal of the Korean Dietetic Association
    • /
    • v.13 no.4
    • /
    • pp.345-356
    • /
    • 2007
  • The purpose of this study was to investigate utilization and storage management practice of the frozen and refrigerated foods in school foodservice. 222 dietitians employed in school foodservice were surveyed. In school foodservice, the refrigerated stock farm products and seafoods (78.3%) were more used rather than frozen products (47.5%). According to school foodservice characteristics, the refrigerated meats including dairy products were more frequently used in elementary and middle schools than high school foodservice. On the other hand, the foodservice in high school used more frozen seafoods and processed foods than elementary school did. The data also showed a tendency for the contracted foodservice using more frozen meats and seafoods rather than refrigerated products when comparing with the self-operated foodservice. In terms of receiving conditions, storage methods and storage time, the result indicated that frozen or refrigerated products were often delivered at inappropriate temperature. Especially some products which were needed to be shipped and stored at refrigerated temperature such as mollusks, were delivered and kept at room temperature. The most frequently used thawing method were running water (56.9%), however, the frozen products were often sitted at room temperature for the purpose of thawing. According to the results, several inappropriate handling processes for frozen and refrigerated products were found in school foodservice. In order to improve handling process for frozen and refrigerated products, recognition of food handlers' weakness about storage and distribution, development of radical standards for receiving conditions, storage and thawing methods should be debated.

  • PDF

A Study on the Changes of Pork Quality by Freezing and Thawing Methods (돈육의 냉해동 조건에 따른 품질 변화에 관한 연구)

  • Kang, Byung-Sun;Kim, Dong-Ho;Lee, Oh-Seuk
    • Culinary science and hospitality research
    • /
    • v.14 no.2
    • /
    • pp.286-292
    • /
    • 2008
  • The purpose of this study was to examine the effects of freezing and thawing methods on the quality of pork meat. The freezing methods for pork meat were the cryogenic freezing with liquid nitrogen gas, fast freezing at $-70^{\circ}C$ and normal freezing at $-20^{\circ}C$. The thawing methods were tested on low temperature thawing at refrigerative temperature($4^{\circ}C$), room temperature($20^{\circ}C$), high temperature($60^{\circ}C$) and using microwave. The quality of pork meat frozen by cryogenic methods was better than those of fast and normal freezing methods. The cooking hardness of pork meat frozen by cryogenic method showed the highest value as 1,898 g. In case of fast freezing, the hardness of pork meat was 1,472 g and that of normal frozen pork meat was 1,541 g. The high cooking hardness value of cryogenic frozen pork meat showed that the cryogenic freezing method made less freeze damage like textural softness. The drip-loss of pork meat thawed at refrigerative temperature($4^{\circ}C$), room temperature($20^{\circ}C$), high temperature($60^{\circ}C$) were shown lower than that of microwave thawing. The cooking hardness of pork meat that was thawed by microwave showed the lowest value among the thawing methods. The cryogenic freezing was the most useful freezing method for preserving quality, decreasing the freeze damage of pork meat. And thawing at refrigerative temperature was the most effective method to prevent quality loss and weight loss by drip-loss.

  • PDF

A Numerical Modeling of Thawing Rate for Frozen Pork using High Pressure Assisted Thawing Technique

  • Ryu, Hyun-Sik;Park, Sung-Hee;Min, Sang-Gi
    • Proceedings of the Korean Society for Food Science of Animal Resources Conference
    • /
    • 2004.10a
    • /
    • pp.310-315
    • /
    • 2004
  • The objective of this study was to provide the optimum thawing condition under different level of high pressure(50, 100, 150 and 200 MPa) using high pressure assisted technique which can improve the quality of frozen and thawed pork. The calculated thawing rate from the results depending on the high pressure showed the strong trend of increased thawing rate under pressurized condition(P<0.05). And then, the numerical modeling was executed to predict the thawing rate influenced by the pressure level using exponential regression, LnY=0.70623 + 0.00433 ${\cdot}$ P ($R^2=0.9985$), and it was fairly fit for the functional relation between the thawing rate(Y) and pressure(P) with comparatively high coefficient, $R^2$ of determination.

  • PDF

Study of Radio Frequency Thawing for Cylindrical Pork Sirloin

  • Kim, Jinse;Park, Jong Woo;Park, Seokho;Choi, Dong Soo;Choi, Seung Ryul;Kim, Yong Hoon;Lee, Soo Jang;Park, Chun Wan;Han, Gui Jeung;Cho, Byoung-Kwan
    • Journal of Biosystems Engineering
    • /
    • v.41 no.2
    • /
    • pp.108-115
    • /
    • 2016
  • Purpose: Radio frequency (RF) heating is a promising thawing method, but it frequently causes undesirable problems such as non-uniform heating. This can occur because of the food shape, component distribution, and initial temperature differences between food parts. In this study, RF heating was applied to the thawing of cylindrically shaped pork sirloin by changing the shape of electrodes and the surrounding temperature. Methods: Curved electrodes were utilized to increase the thawing uniformity of cylindrically shaped frozen meat. Pork sirloin in the shape of a half-circle column was frozen in a deep freezer at $-70^{\circ}C$ and then thawed by RF heating with flat and curved electrodes. In order to prevent fast defrosting of the food surface by heat transfer from air to the food, the temperature of the thawing chamber was varied by -5, -10, and $-20^{\circ}C$. The temperature values of the frozen pork sirloin during RF thawing were measured using fiber-optic thermo sensors. Results: After multiple applications of curved electrodes resembling the food shape, and a cooled chamber at $-20^{\circ}C$ the half-cylindrically shaped meat was thawed without surface burning, and the temperature values of each point were similarly increased. However, with the parallel electrode, the frozen meat was partially burned by RF heating and the temperature values of center were overheated. The uniform heating rate and heat transfer prevention from air to the food were crucial factors for RF thawing. In this study, these crucial factors were accomplished by using a curved electrode and lowering the chamber temperature. Conclusions: The curved shape of the electrode and the equipotential surface calculated from the modeling of the parallel capacitor showed the effect of uniform heating of cylindrically shaped frozen food. Moreover, the low chamber temperature was effective on the prevention of the surface burning during RF thawing.

Seminal plasma modulates post-thaw longevity and motility of frozen sperm in dromedary camel

  • Fahimeh Seyedasgari;Behnam Asadi;Ellen Kim
    • Animal Bioscience
    • /
    • v.36 no.12
    • /
    • pp.1821-1830
    • /
    • 2023
  • Objective: This study investigated the effect of adding seminal plasma to frozen-thawed semen on the quality of sperm and pregnancy following insemination in dromedary camels. Methods: In experiment 1, the frozen-thawed semen from 9 collections (3 bulls) was further diluted with either the base extender or homologous seminal plasma (HSP). In the second experiment, a pooled sample of frozen-thawed semen was diluted with either seminal plasma from another three bulls. Live percentage, total and progressive motility, functional and acrosome integrity, and sperm kinematics were evaluated at 15, 60, and 120 minutes post-thawing and compared to the non-treated control. In experiment 3, frozen semen was used to inseminate camels in the following experimental groups: 1-Single insemination with double dose undiluted frozen semen (n = 9); 2-Re-insemination in 6 hours with undiluted semen (n = 13); 3-Single insemination with HSP treated sperm (n = 14). Results: Frozen-thawed sperm diluted in HSP or the non-homologous seminal plasma from Bull C indicated an improvement in all parameters after 1 hour post-thawing incubation (p<0.05). The proportion of total and progressively motile sperm did not drop significantly at 60 minutes post-thawing when diluted with the seminal plasma of Bull C (p>0.05). Double insemination with nontreated sperm and single insemination with HSP-treated sperm resulted in similar pregnancy rates (15.3% vs 21.4%, p>0.05). None of the camels conceived with double-dose single insemination of nontreated sperm. Conclusion: Seminal plasma improves sperm longevity and motility after thawing in dromedary camel with a significant between-bull variation in effect. Low post-thaw sperm longevity might be the cause behind the low pregnancy rates in frozen semen insemination of dromedary camels.

Effects of Freezing-Thawing Conditions on Physicochemicnl and Histological Properties of Plaice, Paralichthys olivaceus Muscle (동결-해동 조건이 넙치육의 물리$\cdot$화학적 및 조직학적 변화에 미치는 영향)

  • CHO Young-Je;CHO Min-Sung;LEE Nam-Gul;CHOI Young-Jun;KIM Tae-Jin
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.31 no.4
    • /
    • pp.463-470
    • /
    • 1998
  • To improve muscle quality and prolong freshness of sashimi, the effects of freezing-thawing condition on physicochemical and rheological properties of plaice muscle were investigated. Muscle tested were frozen with quick freezing (liquid nitrogen gas) or slow freezing ($-15^{\circ}C$ air). Transition time of zone of ice crystal formation was within 10 minute for quick freezing and 110 minute for slow freezing. Time required for thawing to $0^{\circ}C$ in muscle temperature by various thawing methods was shortest with $25^{\circ}C$ tap water, followed by $15^{\circ}C$ tap water, $10^{\circ}C$ tap water, $25^{\circ}C$ air, $5^{\circ}C$ tap water and $0^{\circ}C$ cold water. Breaking strength of muscle was higher in quickly frozen sample than in slowly frozen sample. According to sashimi term, changes in breaking strength of muscle did not show any difference in quickly frozen sample, while showed significant difference in slowly frozen sample. The remaining content of ATP was not effected by freezing speed, and ATP content was apt to higher in quickly thawed sample than in slowly thawed sample. IMP was the majority of ATP and it's related compounds of sample after freezing and thawing. Collagen matrix was weakened markedly in slowly frozen sample than in quickly frozen sample.

  • PDF

Study on the Freezing Conditions for the Frozen-Dough Preparation of Bread (냉동생지 제조를 위한 냉동조건 탐색)

  • Hahn Young-Sook
    • Journal of the East Asian Society of Dietary Life
    • /
    • v.14 no.5
    • /
    • pp.443-448
    • /
    • 2004
  • In order to investigate the optimal factors for frozen dough production, the freezing and thawing condition such as temperature and time, storage period and the effect of ingredient addition were determined. A pre-fermentation of dough at 30℃ for 120 minutes was appeared to be the best for the production of frozen dough. The dough was frozen at -18℃ and then stored for 7 days. The quality of frozen dough was found to be optimal when thawed at 30℃ for 80 minutes. As ingredient of frozen dough, an addition of 3% of yeast and 4% of butter was good as well as the addition of skim milk and sugar in terms of fermentation capacity after thawing.

  • PDF

Effects of Various Thawing Methods on the Quality Characteristics of Frozen Beef

  • Kim, Young Boong;Jeong, Ji Yun;Ku, Su Kyung;Kim, Eun Mi;Park, Kee Jae;Jang, Aera
    • Food Science of Animal Resources
    • /
    • v.33 no.6
    • /
    • pp.723-729
    • /
    • 2013
  • In this study, the quality characteristics due to the influence of various thawing methods on electro-magnetic and air blast frozen beef were examined. The loin and round of second grade Hanwoo were sliced into 5-7 cm thickness and packed with aerobic packaging. The packaged beef samples, which were frozen by air blast freezing at $-45^{\circ}C$ and electro-magnetic freezing at $-55^{\circ}C$, were thawed by 4 thawing methods with refrigeration ($4{\pm}1^{\circ}C$), room temperature (RT, $25^{\circ}C$), cold water ($15^{\circ}C$), and microwave (2450 MHz). These samples were thawed to the point, which were core temperature reached $0^{\circ}C$. Analyses were carried out to determine drip and cooking loss, water holding capacity (WHC), moisture contents and sensory evaluation. Frozen beef thawed by microwave indicated a lower drip loss (0.66-2.01%) than the other thawing methods (0.80-2.50%). Cooking loss after electro-magnetic freezing indicated 52.0% by microwave thawing for round compared with 41.8% by refrigeration, 50.1% by RT, and 50.8% by cold water. WHC thawing by microwave with electro-magnetic freezing didn't showed any difference depending on the thawing methods, while moisture contents was higher thawing by microwave with electro-magnetic freezing than refrigeration (71.9%), RT (75.0%), and cold water (74.9%) for round. The texture of sensory evaluation for round thawed by microwave result was the highest than refrigeration (4.7 point), RT (6.4 point) and cold water (6.6 point), while sensory evaluation was no significant difference. Therefore, it was shown that microwave thawing is an appropriate way to reduce the deterioration of meat quality due to freezing.